Anda di halaman 1dari 7

Italiano (http://www.genmacgenerators.

com/it/genmac-nder-it/) English
(http://www.genmacgenerators.com/en/genmac-nder-en/) Franais
(http://www.genmacgenerators.com/fr/genmac-nder-fr/) Deutsch
(http://www.genmacgenerators.com/de/genmac-nder-de/) Espaol
(http://www.genmacgenerators.com/es/genmac-nder-es/)
(http://www.genmacgenerators.com/ru/genmac-nder-ru/)

IT EN
(http://www.genmacgenerators.com/it (http://www.genmacgenerators.com/e
FR DE
/genmac-finder-IT/? n/genmac-finder-EN/?
(http://www.genmacgenerators.com/fr (http://www.genmacgenerators.com/d
RU
frq=50&cov=S&pot=500&mot=110&al ES
frq=50&cov=S&pot=500&mot=110&al
/genmac-finder-FR/? e/genmac-finder-DE/?
(http://www.genmacgenerators.com/r (http://www.genmacgenerators.com/e
t=108&man=328&mod=3638&atn=sh t=108&man=328&mod=3638&atn=sh
frq=50&cov=S&pot=500&mot=110&al frq=50&cov=S&pot=500&mot=110&al
u/genmac-finder-RU/?
m) s/genmac-finder-ES/?
m)
t=108&man=328&mod=3638&atn=sh t=108&man=328&mod=3638&atn=sh
frq=50&cov=S&pot=500&mot=110&al frq=50&cov=S&pot=500&mot=110&al
m)
t=108&man=328&mod=3638&atn=sh MAGNUM G400VS m) + QT2A-4520
t=108&man=328&mod=3638&atn=sh
m) m)
MAGNUM G400VS
Conventional power
400 kVA PRP
Engine model
Volvo-Penta TAD1344GE
Alternator model
Stamford HCI444F
Length mm
4500
Width mm
1666
Height mm
2250
Weight Kg (dry net)
4730
Sound pressure at 7 mt dBA
-

Genset technical datasheets

400V 3PH 50 Hz (http://www.genmacgenerators.com/en/pdf-


generator-en/?
idgen=3638&man=328&volt=400&freq=50&phas=3FN&pers=s)

General equipment
Silent generator with following specifications:

Frame:
- Heavy duty fabricated welded base plate with high quality steel UNI S235 JR
- Heavy duty, bell type, rubber anti-vibration mountings
- Dedicated area to make easier the electrical connection to the load
- Fuel tank with drain plug
- Feet and four lifting holes on the base
- Oil draining mechanical pump

Canopy:
- Large doors for easy access for service and maintenance
- Metalsheet Cut using high precision laser technology
- Weatherproof sealed joints
- High-tech Nylon hinges: rust-free, no need to lubricate
- Lockable handles in each door
- Grey RAL 7035 orange peel specific powder coat paint for outdoor usage
- Rain cap on exhaust outlet
- Coolant refilling specific hatch
- Fuel filler outside enclosure
- Ecological Sound foam: 100% Recyclable, 40mm thickness, fire-proof self-extinguishing class1 fire-reaction
compliant washable, mechanically fixed to the frame

Control Panel:
- Self-standing control panel tower made with metal structure and components to grant IP65 protection, easily
removable for maintenance
- Easy access to control panel through a canopys door, equipped with lexan window
- Control panel is divided in two independent and insulated boxes separating Controls (Controller and numbered
terminal board) from Power connection (circuit breaker and cable inlet)
- External dedicated area to make easier the electrical connection to the load
- Power connection between circuit breaker and alternator made with high resistance neoprene cables (H07RNF)
and using cable glands for waterproof connections

All units and components are prototype tested, factory build and production tested. A specific control procedure
during the several stages of production ensures long life and reliability.

Genset manual MAGNUM G400VS (http://www.genmacgenerators.com/wp-content/uploads/2016/03/000-R-


08-Use-and-maintenance-manual-ITGB25.pdf)

Installation drawing MAGNUM G400VS (http://www.genmacgenerators.com/wp-


content/uploads/2016/07/Installation-drawing-MAGNUM-with-620L-tank.pdf)

Installation manual MAGNUM G400VS (http://www.genmacgenerators.com/wp-


content/uploads/2016/03/Genmac-Application-and-Installation-manual-EN-REV-00-18_03_201613.pdf)

CONTROL PANEL FEATURES

QT2A-4520
DEEP SEA DSE4520

General equipment
Self-standing tower with IP55 metal box
Circuit breaker
AMF controller DSE4520
- Voltmeter, Frequencymeter, Ammeter
- Generator power (kW, kV Ar, kV A & pf) monitoring
- Hour meter
- Fuel level meter
- Overload (kW & kV Ar) protection
- Low oil pressure protection
- High coolant temperature protection
- Low fuel level protection
- Battery charger alternator fault
- Rpm protection
Emergency stop button
Audible alarm
Terminal board for ATS connection
Can Bus reading Port (if standard on the engine)
Battery charger
On/off switch
Controller technical datasheet DEEP SEA DSE4520 (http://www.genmacgenerators.com/wp-
content/uploads/2016/03/DSE4510-DSE4520-Data-Sheet1.pdf)

Controller user manual DEEP SEA DSE4520 (http://www.genmacgenerators.com/wp-


content/uploads/2016/03/DSE4510-DSE4520-Operators-manual1.pdf)

Technical diagramm QT2A-4520 (http://www.genmacgenerators.com/wp-


content/uploads/2016/03/B0751-00_QTA-4520-TORR5.pdf)

Battery charger technical datasheet (http://www.genmacgenerators.com/wp-


content/uploads/2016/03/31539-31540-Carica-Batteria-BCF8.pdf)

QUADRI ATS DISPONIBILI

OUTDOOR INSTALLATION. CONTACTORS VERSION


Technical datasheet ATS-C (http://www.genmacgenerators.com/wp-content/uploads/2016/03/Technical-
datasheet_ATS-C-ATS-M_Rev05_160310.pdf)

User manual ATS-C (http://www.genmacgenerators.com/wp-content/uploads/2016/03/GENMAC_ATS-C-


MANUAL_EN_v01.pdf)

Technical diagramm ATS-C (http://www.genmacgenerators.com/wp-content/uploads/2016/03/ATS-


C_4P_400V_Layout_Diagram.pdf)

OUTDOOR INSTALLATION. VERSION WITH MOTORIZED BREAKERS

Technical datasheet ATS-M (http://www.genmacgenerators.com/wp-content/uploads/2016/03/Technical-


datasheet_ATS-C-ATS-M_Rev05_1603101.pdf)

User manual ATS-M (http://www.genmacgenerators.com/wp-content/uploads/2016/03/GENMAC_ATS-M-


MANUAL_EN_v011.pdf)

Technical diagramm ATS-M (http://www.genmacgenerators.com/wp-content/uploads/2016/07/ATS-M_4P-


400V_Layout_Diagram.pdf)

ENGINE DOCUMENTATION

Engine datasheet (http://www.genmacgenerators.com/wp-content/uploads/2015/12/Installation-


t_tad1344ge_21340722_03.pdf)

Engine manual (http://www.genmacgenerators.com/wp-content/uploads/2016/04/Operators-manual-13L-EN-


111000000381-001-012.pdf)

ALTERNATOR DOCUMENTATION
Alternator datasheet (http://www.genmacgenerators.com/wp-content/uploads/2015/09/HCI434F-444F.pdf)

Alternator manual (http://www.genmacgenerators.com/wp-content/uploads/2015/09/Use-and-Maintenance-


Manual-HC_EN2.pdf)

SILENCER DOCUMENTATION

Genmac s.r.l. 42044 Gualtieri RE ITALY tel. +39 0522 222 311 www.genmac.it (http://www.genmacgenerators.com) All
rights reserved.