Anda di halaman 1dari 3

PASSIVE HARMONICS FILTER ( 30 KVA)

Passive harmonic filters help to obtain compliance with international Power Quality
standards like e.g. IEEE 519-1992 or EN 61000-3-12.

The non linear Loads generate Harmonics distortion. Our Passive Harmonic Filters
are ideal for Commercial and Industrial applications. The equipments like UPS,
Computers, Printers, LED/CFL/PL Lamps, AC drive - Motors, Pumps , Lifts, Crane,
Compressors, HVAC, Chillers , Compressors and many other Electronic loads
produce more current Harmonics distortion. Our Passive Harmonic Filters
mitigating all the Harmonics issues and maintain IEEE-519 standards. Even if
Harmonics generating sources of your 3 /1Phase Load is single or multiple
Locations, it is possible that Harmonics can be supressed at particular location only.
It will not spread to all other circuit. This static device consist of series inductive /
parallel inductive, resistive, capacitive (RLC) network tuned to individual harmonics
for a 50Hz fundamental frequency and required no maintenance. Life is 15 years.

The higher the harmonic components , larger the waveform distortions. This larger
deviations from the sinusoidal fundamental frequency are integer multiples of the
fundamental frequency. For example on 50Hz supply, the 3rd harmonic is 3 x 50Hz
(150Hz) the 5th harmonic is 5 x 50Hz (=250Hz) and so forth.

PASSIVE HARMONICS FILTER MODELS


1) TP- Suitable for Three Phase Load 3Ph,3 wire 415+/-10%,50Hz
- Suitable for Diode Rectifiers, AC Drives, Six pulse rectifiers, Three Phase UPS etc.
- Suitable for 3 rd Harmonics Only

2) TPN -Suitable for single Phase and three Phase Load 3Ph,4 wire 415+/-10%,50 Hz.
- Suitable for any type of Load. All different types of odd and even current Harmonics
need to be reduced to defined limit.
- Suitable for 3 rd, 5 th, 7 th and Higher Harmonics

Site requirements: THVD < 3%, Line voltage unbalance <1%


Special requirements: THVD < 5%, Line voltage unbalance <1%
HARMONICS FILTERATION TOPOLOGY

INCOMING
SUPPLY
BNN NON LINEAR
PUREGREEN LOAD

SINGLE LINE DIAGRAM MODEL- TP

MAINS LOAD
INPUT FILTER OUTPUT FILTER

FREQUENCY TUNING
MATCHING CAPACITORS

SINGLE LINE DIAGRAM MODEL- TPN

MAINS LOAD
BALANCING INPUT OUTPUT OUTPUT
FILTER FILTER FILTER-1 FILTER-2

TUNING
CAPACITORS

FREQUENCY TUNING
MATCHING CAPACITORS
Advantages

Rigid sturdy Device


Guaranteed Harmonics reduction Individual / % THD
Reduces maintenance cost of your costly equipments
Safeguards sensitive devices from spikes & transient
Maintain Voltage & current unbalance
Long life without maintenance/AMC
Provides Energy saving by reduction of Heat and respective burdon on
Cables & Transformers
Certain models maintain near unity power factor without power capacitors

Applications

1) Commercial Offices, Banks, Shops, ATMS etc.


2) Industrial applications AC Drives, UPS/Inverters, Induction furnace etc.
3) IT Sector companies
4) Malls
5) Welding Machines
6) Lift/ Cranes
7) Ships, Airports
8) HVAC Installations
9) Water Treatment Plants

Symptoms of Harmonics Presence

1) Lamp fluctuations / intensity variation


2) Equipment /Computers/Printers/Motors/Lamps frequent failure
3) Increase in maintenance
4) Cables/ Transformers heating
5) Neutral wire burnt
6) Nuisance tripping of MCB/MCCB/FUSES etc.
7) Increases Voltage distortion
8) If limits of IEEE519 standards exceeded penalty charged by supply
company.
9) Premature failure of capacitors / APFC panel.
10) Digital Meters frequent failure/ damage.