Anda di halaman 1dari 2

Overview

Solarflare SFN6322F Dual-Port 10GbE


The Solarflare SFN6322F dual-port SFP+ server adapter combines precision time
Precision Time Synchronization Server synchronization and timestamping of PTP packets with ultra-low latency 10G Ethernet.
The adapter is suitable for networks where there is a requirement to support the IEEE
Adapter 1588 Precision Time Protocol (PTP).

User Guides
Quick Start Guide For details of SFN6322F deployment and PTP operation refer to the Solarflare PTP User
Guide SF-107094-CD. For comprehensive installation instructions and details of how to
Part number: SFN6322F configure a server adapter (including detailed performance tuning guides) please consult
the Solarflare Server Adapter User Guide SF-103837-CD.

The user documentation can be downloaded from


https://support.solarflare.com

Drivers
The Solarflare SFN6322F adapter supports the following Linux distributions: RHEL5, 6
and MRG, SLES10, 11 and SLERT distributions. Solarflare also supply an enhanced PTPd
version 2 stack for the SFN6322F adapter.

The latest Solarflare drivers can be downloaded from


https://support.solarflare.com

OpenOnload
Solarflare server adapters also support OpenOnload a kernel bypass accelerated
user-level TCP/IP network stack. The OpenOnload library dynamically links with the
Information in this document is subject to change without notice. application at runtime using the standard POSIX BSD sockets API.

2012 Solarflare Communications Inc. All rights reserved. To learn more about OpenOnload please visit
http://www.openonload.org
Trademarks used in this text are registered trademarks of Solarflare Communications
Inc. Microsoft and Windows are registered trademarks of Microsoft Corporation.
Linux is the registered trademark of Linus Torvalds in the U.S. and other countries. Support
Other trademarks and trade names may be used in this document to refer to either the If you have any questions on your Solarflare products please contact your sales
entities claiming the marks and names or their products. Solarflare Communications representative or contact Solarflare:
Inc. disclaims any proprietary interest in trademarks and trade names other than its
own. For support on Solarflare products please email
support@solarflare.com
SF-108432-CD Version 3

Solarflare adapters covered by this guide


The following table lists the Solarflare SFP+ server adapters that are covered by this
Installing the Adapter
quick start guide: The Solarflare SFN6322F server adapter is compatible with Intel and AMD x86 PCs with
8-lane or 16-lane PCI Express Gen2 (5GHz) slots:
Number of Maximum Supports Supports
Part number
SFP+ Ports vNICs/Port SRIOV OpenOnload
CAUTION: Servers contain high voltage electrical components. Before
SFN6322F 2 1024 Yes Yes removing the server cover, disconnect the mains power supply to
avoid the risk of electrocution. Before handling computer
components, discharge static electricity from yourself by touching a
metal surface, or wear a correctly fitted anti-static wrist band.

NOTE: The time synchronization features are only supported on port 1 of the
network adapter which is the port closest to the PCIe connector.

Removing the Bracket


The SFN6322F adapter is supplied with a full height bracket including 1PPS I/O cables
connected to SMT connections on the PCB. If it is required to remove or replace this
bracket, the 1PPS cables must be disconnected from the SMT connections. Care must
be taken to ensure the connectors are not damaged during removal. The cables should
lie in the position indicated in the diagram and a small screwdriver used to gently ease
the I/O cables from the SMT connections.
Limited Warranty
Before using any of the Products, Purchaser shall determine the suitability of the
Products for Purchasers intended use by considering such factors as overall product
design and the processing and environmental conditions to which the Products will be
subjected. Solarflare warrants solely to Purchaser, for a period of 1 year from the date a
Product is delivered to Purchaser (the Warranty Period), that the Product will
conform in all material respects to Solarflares published specifications for such Product
in effect as of the date of purchase (the Limited Warranty).

To view the whole warranty, visit:


http://www.solarflare.com/Content/userfiles/documents/
Solarflare_HardwareWarranty.pdf
Inserting the Adapter in a PCI Express Slot
Shut down the server and unplug it from its power source. Remove the server cover to
Warnings
access the PCI Express slots in the server. Locate an 8-lane or 16-lane PCI Express Gen 2 Changes or modifications not expressly approved by Solarflare Communications Inc.,
slot (refer to the server manual if necessary) and insert the Solarflare server adapter. the party responsible for FCC compliance, could void the user's authority to operate
Secure the adapter bracket in the slot. the equipment.

This Class B digital apparatus complies with Canadian ICES-003.


Cet appareil numrique de la classe B est conforme la norme NMB-003 du Canada.

Underwriters Laboratory Inc ('UL') has not tested the performance or reliability of the
security or signaling aspects of this product. UL has only tested for fire, shock or
casualty hazards as outlined in the UL's Standard for Safety UL 60950-1. UL
Certification does not cover the performance or reliability of the security or signaling
aspects of this product. UL makes no representations, warranties or certifications
whatsoever regarding the performance or reliability of any security or signaling
related functions of this product.

The laser safety of this product has been verified using the following certified laser
device module (LDM):

CDRH Accession Mark of


Manufacturer Model File No
No conformity
Avago AFBR-
NOTE: Solarflare SFN6322F server adapters require an 8-lane or 16- 9720151-072 TUV R72071411
Technologies 703SDZ
lane PCI Express Gen 2 slot. Consult your server manual to ensure
the correct slot is used. FTLX8571D3
Finisar Corporation 9210176-094 TUV R72080250
BCL

Completing the Installation


When installed in a 10Gb ETHERNET NETWORK INTERFACE CARD FROM THE
For information on installing drivers and utilities, please consult the relevant section of SOLARFLARE SFN5000 SERIES, the laser emission levels remain under Class I limits as
the Solarflare Server Adapter User Guide. specified in the FDA regulations for lasers, 21 CFR Part 1040.

Cables and Transceivers The decision on what LDMs to use is made by the installer. For example, equipment
may use one of a multiple of different LDMs depending on path length of the laser
Solarflare supplies the SFM10G-SR transceiver enabling a single order for the entire
communication signal. This equipment is not basic consumer ITE.
10GbE solution. The Solarflare SFN6322F SFP+ server adapter also supports a wide
range of SFP+ direct attach cables, 10G-SR optical transceivers, 1G optical transceivers
This equipment is installed and maintained by qualified staff from the end user
and 1000BASE-T transceivers.
communications company or subcontractor of the end user organization. The end
product user and/or installer are solely responsible for ensuring that the correct
For a full list of supported cables and transceivers please devices are utilized in the equipment and the equipment with LDMs installed complies
consult the installation chapter in the Solarflare User Guide with applicable laser safety requirements.
https://support.solarflare.com

Warnings Regulatory Approval


Do not install this product in hazardous areas where highly combustible or explosive
Category Specification Details
products are stored or used without taking additional safety precautions. Do not
expose this product to rain or moisture. BS EN 55022:2006 +A1:2007
Europe
BS EN 55024:1998 +A1:2001
This Class III SELV product is intended only to be powered by a certified limited power
source. US FCC CFR 47 Part 15 Class B
Canada ICES 003/NMB-003 Class B
NOTE: This equipment has been tested and found to comply with the limits for a Class B EMC
Taiwan CNS 13438:2006 Class A
digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide
reasonable protection against harmful interference in a residential installation. This Japan VCCI Regulations V-3:2010 Class A
equipment generates, uses and can radiate radio frequency energy and, if not installed South Korea KCC KN-22, KN-24
and used in accordance with the instructions, may cause harmful interference to radio
Australia AS/NZS CISPR 22:2009
communications. However, there is no guarantee that interference will not occur in a
particular installation. Europe BS EN 60950-1:2006 +A11:2009
US UL 60950-1 2nd Ed.
If this equipment does cause harmful interference to radio or television reception, Safetya
which can be determined by turning the equipment off and on, the user is encouraged Canada CSA C22.2 60950-1-07 2nd Ed.
to try to correct the interference by one or more of the following measures: CB IEC 60950-1:2005 2nd Ed.
-- Reorient or relocate the receiving antenna. RoHS Europe Complies with EU directive 2002/95/EC
-- Increase the separation between the equipment and receiver.
-- Connect the equipment into an outlet on a circuit different from that to which the a. The safety assessment has been concluded on this product as a compo-
receiver is connected. nent /sub-assembly only.
-- Consult the dealer or an experienced radio/TV technician for help.

9&&,
$



$  $ Solarflare Boot Manager


 
 The Solarflare Boot Manager is installed in the adapter's flash memory. This program is
free software; you can redistribute it and/or modify it under the terms of the GNU
General Public License as published by the Free Software Foundation.This program is
distributed in the hope that it will be useful, but WITHOUT ANY WARRANTY; without
even the implied warranty of MERCHANTABILITY or FITNESS FOR A PARTICULAR
PURPOSE. See the GNU General Public License for more details. Either the latest or an
earlier version of the source code for the Solarflare Boot Manager can be requested by
sending an e-mail to support@solarflare.com.