Anda di halaman 1dari 12

Coloumn

Member
H
AD - DE 203.2
DH - HI 402.8
BE - EF 303.3
EI - IJ 350.3
CF - FG 306.3
FJ - JK 203.2
BE - ED 303.3
EI - IH 350.3
CF - FE 306.3
FJ - JI 203.2

Member Shear 1
AD - DE 77.715
DH - HI 77.715
BE - EF 77.715
EI - IJ 77.715
CF - FG 77.715
FJ - JK 77.715
BE - ED 77.715
EI - IH 77.715
CF - FE 77.715
FJ - JI 77.715

Profil L
Member L
AD - DE 80x80x12
DH - HI 80x80x12
BE - EF 100x100x14
EI - IJ 100x100x14
CF - FG 130x130x14
FJ - JK 100x100x14
BE - ED 100x100x14
EI - IH 100x100x14
CF - FE 130x130x14
FJ - JI 100x100x14

Design of Bolts at The Flange of The Beam


Member Shear Force
AD - DE 207.0195301444
DH - HI 321.3759213759
BE - EF 159.815609601
EI - IJ 438.3769518364
CF - FG 823.1000501086
FJ - JK 657.2980182927
BE - ED 508.7258304413
EI - IH 749.2723492724
CF - FE 634.0009537434
FJ - JI 671.3437431273
Profil WF
Coloumn
B TW
203.1 7.239
177.4 7.493
203.3 7.493
204 8.636
253.9 8.763
203.1 7.239
203.3 7.493
204 8.636
253.9 8.763
203.1 7.239

Shear 2 Bearing
155.43 81.88992
155.43 86.85504
155.43 99.53568
155.43 97.6752
155.43 116.99712
155.43 83.35224
155.43 81.97056
155.43 99.8784
155.43 124.30944
155.43 97.24428

Profil L
a b
80 80
80 80
100 100
100 100
130 130
100 100
100 100
100 100
130 130
100 100

nge of The Beam


Number of Bolts Needed
2.6638297645
4.1353139211
2.0564319578
5.6408280491
10.5912635927
8.4578011747
6.54604427
9.6412835266
8.1580255259
8.6385349434

Design of Bolts Between Web of The Beam and Flange of The Column
Member Shear Force
AD - DE
DH - HI
BE - EF
EI - IJ
CF - FG
FJ - JK
BE - ED
EI - IH
CF - FE
FJ - JI
Profil WF
Beam
TF H
11 353.3
10.9 529.1
13.1 629.1
15.1 454.7
14.6 598.7
11 524.8
13.1 403.4
15.1 529.1
14.6 629.1
11 454.7

Tension d=M/2T
145.715625 250.9682815415
145.715625 583.4652255034
145.715625 344.9870252418
145.715625 683.9692037144
145.715625 1690.9305367904
145.715625 1183.6410817303
145.715625 704.179802269
145.715625 1360.3208303845
145.715625 1368.5903622209
145.715625 1047.4511570053

d r
12 10
12 10
14 12
14 12
14 14
14 12
14 12
14 12
14 14
14 12

Design of Bolts Between Web of The Beam and L Profile


Member Shear Force
AD - DE
DH - HI
BE - EF
EI - IJ
CF - FG
FJ - JK
BE - ED
EI - IH
CF - FE
FJ - JI

eam and Flange of The Column


Number of Bolts Needed
Beam
B TW TF
127.6 6.985 11.2
165.9 9.652 13.6
165.9 9.652 13.6
152.8 8.001 13.3
177.9 0.01 12.8
165.1 8.89 11.4
140.3 6.985 11.2
165.9 9.652 13.6
165.9 9.652 13.6
152.8 8.001 13.3

s a T
-51.1658592292
27.1826127517
-142.0564873791
114.6346018572
546.1152683952
329.4205408651
150.3899011345
415.6104151923
369.7451811105
296.3755785026

r1
5
5
6
6
7
6
6
6
7
6

he Beam and L Profile


Number of Bolts Needed
Shear Momen
395.43 73.14
240.44 170.04 Material Prope
720.71 100.54 fy 290
434.8 199.33 fu 420
1010.98 492.79
418.34 344.95
720.71 205.22
434.8 396.44
1010.98 398.85
418.34 305.26

Mu
Material Properties
Mpa fub 825 Mpa
MPa bolt diameter 20 mm