3M ACCR Technical Summary
Physical Properties Unit Ostrich 300 Linnet 336 Ibis 397 Hawk 477 Dove 557
Designation ACCR_297-T16 ACCR_340-T16 ACCR_405-T16 ACCR_470-T16 ACCR_573-T16
Stranding 26/7 26/7 26/7 26/7 26/7
Diameter
Individual Core Wire in 0.083 0.089 0.097 0.105 0.116
Individual Al Wire in 0.107 0.114 0.125 0.134 0.149
Total Core in 0.249 0.267 0.291 0.314 0.347
Total Conductor in 0.677 0.724 0.791 0.852 0.941
Area
Aluminum in2 0.233 0.267 0.318 0.369 0.450
Total Area in2 0.271 0.310 0.370 0.429 0.524
Weight
Core lbs/ft 0.057 0.066 0.078 0.090 0.110
Aluminum lbs/ft 0.279 0.320 0.382 0.443 0.540
Total Weight lbs/ft 0.337 0.385 0.460 0.533 0.650
Strength lbs 12,100 13,900 16,500 19,200 23,100
Thermal Elongation
Core 10-6/C 6.3 6.3 6.3 6.3 6.3
Aluminum 10-6/C 23.0 23.0 23.0 23.0 23.0
Complete Cable 10-6/C 16.7 16.7 16.7 16.7 16.7
Heat Capacity
Core W-sec/ft-C 8 10 11 13 16
Aluminum W-sec/ft-C 121 139 165 192 234
Electrical Properties
To learn more about Resistance
3M ACCR, or to down- DC @ 20C ohms/mile 0.2939 0.2568 0.2153 0.1855 0.1521
load the PLS-CADD AC @ 25C ohms/mile 0.3009 0.2629 0.2204 0.1899 0.1558
data files, visit us at AC @ 50C ohms/mile 0.3307 0.2889 0.2422 0.2087 0.1712
www.3M.com/ACCR AC @ 75C ohms/mile 0.3605 0.3150 0.2640 0.2275 0.1866
AC @ 100C ohms/mile 0.3902 0.3410 0.2858 0.2463 0.2020
AC @ 210C ohms/mile 0.5213 0.4555 0.3818 0.3290 0.2699
AC @ 240C* ohms/mile 0.5571 0.4867 0.4080 0.3516 0.2884
Geometric Mean Radius ft 0.0229 0.0245 0.0267 0.0288 0.0318
Reactance (1 ft spacing, 60hz)
Inductive Xa ohms/mile 0.458 0.450 0.439 0.430 0.418
Capacitive X'a Mohms-mile 0.1059 0.1039 0.1012 0.0990 0.0961
Ampacity
210 C amps 863 942 1,059 1,168 1,332
240 C* amps 944 1,011 1,136 1,254 1,431
* Emergency operating temperature, 1,000 hours cumulative over the life of the conductor. Ampacity ratings were calculated using IEEE Std. 738-1993, with inputs of 40C air
temperature, 2.0 ft/s wind, and emissivity and absorptivity of 0.5, at sea level.
2
Grosbeak 636 Drake 795 Cardinal 954 Curlew 1033 Finch 1113 Pheasant 1272 Martin 1351 Falcon 1590
ACCR_656-T16 ACCR_824-T16 ACCR_967-T13 ACCR_1036-T13 ACCR_1117-T13 ACCR_1267-T13 ACCR_1334-T13 ACCR_1594-T13
26/7 26/19 54/19 54/19 54/19 54/19 54/19 54/19
18 23 21 23 25 28 29 35
267 336 396 424 457 518 546 652
For a complete
0.1333 0.1060 0.0920 0.0859 0.0796 0.0702 0.0667 0.0558 library of lab and
0.1364 0.1085 0.0942 0.0879 0.0815 0.0719 0.0683 0.0571 field tests, organized
0.1499 0.1192 0.1035 0.0966 0.0896 0.0790 0.0750 0.0628 by both conductor
0.1635 0.1300 0.1128 0.1053 0.0977 0.0861 0.0818 0.0684 size and test subject,
visit our website:
0.1770 0.1407 0.1221 0.1140 0.1057 0.0932 0.0886 0.0741
www.3M.com/ACCR
0.2364 0.1880 0.1632 0.1523 0.1413 0.1246 0.1183 0.0990
0.2526 0.2009 0.1743 0.1628 0.1509 0.1331 0.1264 0.1058
0.0309 0.0346 0.0372 0.0385 0.0400 0.0426 0.0437 0.0478
3
3M ACCR Technical Summary
26 23 26 34 36 43
389 420 470 626 662 786
5
3M ACCR Technical Summary
Physical Characteristics
3M Aluminum Conductor Composite Reinforced (ACCR) is a transmission
conductor designed to significantly increase capacity on existing
structures, even in challenging situations and environments.
6
More amps
on existing
structures
Technical Support
Finding the right solution can require knowledgeable
support. Our experienced technical team, with their
proven record of successful solutions, can help you with:
Balancing capacity, efficiency, mechanical load,
clearance, economic and environmental objectives
to find the best solution;
Evaluating line characteristics to define the right
mix of conductor and accessories;
Providing you with data and information on
the phone, through e-mail or on-site;
Assisting you to compare options in PLS-CADD,
SAG10 and other design software;
Supporting your installation crew with training
and consultation throughout the process.
All to provide you the most value from your
upgrade and ensure a successful project.
57
3M ACCR Technical Summary
TECHNICAL INFORMATION AND DATA; PRODUCT USE. Technical information and data, recommendations, and other statements provided by 3M are based on information, tests,
or experience which 3M believes to be reliable, but the accuracy or completeness of such information is not guaranteed. Before use, Buyer must evaluate and determine whether
the 3M product is suitable and appropriate for a particular use and intended application.
WARRANTY AND LIMITED REMEDY. Unless stated otherwise in 3Ms product literature, packaging inserts or product packaging for individual products, 3M warrants that each
3M product meets the applicable specifications at the time 3M ships the product. Individual products may have additional or different warranties as stated on product literature,
package inserts or product packages. 3M MAKES NO OTHER WARRANTIES, EXPRESS OR IMPLIED, INCLUDING, BUT NOT LIMITED TO, ANY IMPLIED WARRANTY OF
MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE OR ANY IMPLIED WARRANTY ARISING OUT OF A COURSE OF DEALING, CUSTOM OR USAGE OF TRADE.
3
Electrical Markets Division
3M High Capacity Conductors
3M Center, Building 251-2A-39
St. Paul, MN 55144-1000 Please recycle. Printed in USA. PLS-CADD is a trademark of Power Line Systems, Inc.
Phone: 800-364-3577 Issued: 7/09 3M 2009. SAG10 is a trademark of Southwire Company.
Fax: 651-736-0431 All rights reserved. 6888HB 3M is a trademark of 3M Company.
www.3M.com/ACCR 80-6016-0279-2 B Used under license by 3M subsidiaries and affiliates.