================================================================================ ================================= MO Attribute Value ================================================================================ ================================= UeMeasControl=1 timeToTrigger1b 14 ================================================================================ ================================= Total: 1 MOs
RNC4> mom . timeToTrigger1b
170324-14:16:14 192.168.41.58 17.0d RNC_NODE_MODEL_V_7_1691 stopfile=/tmp/14475 ################################################################################ #################################################### MO Class Attribute Type Flags ################################################################################ #################################################### ExternalUtranCell timeToTrigger1b long -------------------------------------------------------------------------------- ---------------------------------------------------- Time between detection of event 1b and sending of the measurement report. Used by UE functions for intra-frequency measurement reporting in CELL_DCH. -1 means that cell-level configuration for this cell is disabled. Value mapping: -1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used 0 : 0 ms 1 : 10 ms 2 : 20 ms 3 : 40 ms 4 : 60 ms 5 : 80 ms 6 : 100 ms 7 : 120 ms 8 : 160 ms 9 : 200 ms 10 : 240 ms 11 : 320 ms 12 : 640 ms 13 : 1280 ms 14 : 2560 ms 15 : 5000 ms Dependencies: Used if the feature SoftHoCellConfig is active and the value is >= 0. Otherwise UeMeasControl::timeToTrigger1b in the SRNC is used. Feature: SoftHoCellConfig Change takes effect: Ongoing connections (next reconfiguration where a Measureme nt Control message for Soft/Softer Handover purpose is sent) Range: -1 to 15, Default=-1 ******************************************************************************** **************************************************** RemoteUtranCell timeToTrigger1b long -------------------------------------------------------------------------------- ---------------------------------------------------- Time between detection of event 1b and sending of the measurement report. Used by UE functions for intra-frequency measurement reporting in CELL_DCH. -1 means that cell-level configuration for this cell is disabled. Value mapping: -1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used 0 : 0 ms 1 : 10 ms 2 : 20 ms 3 : 40 ms 4 : 60 ms 5 : 80 ms 6 : 100 ms 7 : 120 ms 8 : 160 ms 9 : 200 ms 10 : 240 ms 11 : 320 ms 12 : 640 ms 13 : 1280 ms 14 : 2560 ms 15 : 5000 ms Dependencies: Used if the feature SoftHoCellConfig is active and the value is >= 0. Otherwise UeMeasControl::timeToTrigger1b in the SRNC is used. Feature: SoftHoCellConfig Change takes effect: Ongoing connections (next reconfiguration where a Measureme nt Control message for Soft/Softer Handover purpose is sent) Range: -1 to 15, Default=-1 ******************************************************************************** **************************************************** UeMeasControl timeToTrigger1b long -------------------------------------------------------------------------------- ---------------------------------------------------- Time between detection of event 1b and sending of the measurement report. Used by UE functions for intra-frequency measurement reporting in CELL_DCH. Value mapping: 0 : 0 ms 1 : 10 ms 2 : 20 ms 3 : 40 ms 4 : 60 ms 5 : 80 ms 6 : 100 ms 7 : 120 ms 8 : 160 ms 9 : 200 ms 10 : 240 ms 11 : 320 ms 12 : 640 ms 13 : 1280 ms 14 : 2560 ms 15 : 5000 ms Change takes effect: Ongoing connections (next switch to CELL_DCH) Range: 0 to 15, Default=12 ******************************************************************************** **************************************************** UtranCell timeToTrigger1b long -------------------------------------------------------------------------------- ---------------------------------------------------- Time between detection of event 1b and sending of the measurement report. Used by UE functions for intra-frequency measurement reporting in CELL_DCH. -1 m eans that cell-level configuration for this cell is disabled. Value mapping: -1: UeMeasControl::timeToTrigger1b and UeMeasControl::reportingRange1b is used 0 : 0 ms 1 : 10 ms 2 : 20 ms 3 : 40 ms 4 : 60 ms 5 : 80 ms 6 : 100 ms 7 : 120 ms 8 : 160 ms 9 : 200 ms 10 : 240 ms 11 : 320 ms 12 : 640 ms 13 : 1280 ms 14 : 2560 ms 15 : 5000 ms Dependencies: Used if the feature SoftHoCellConfig is active and the value >= 0. Otherwise UeMeasControl::timeToTrigger1b is used. Feature: SoftHoCellConfig Change takes effect: Ongoing connections (next reconfiguration where a Measureme nt Control message for Soft/Softer Handover purpose is sent) . For cells that ar e existing in the AS when the change is done, the old value will be used at Acti ve Set update Range: -1 to 15, Default=-1 ******************************************************************************** **************************************************** Total: 4 MOs, 4 attributes
RNC4> get . maxactive
170324-14:16:26 192.168.41.58 17.0d RNC_NODE_MODEL_V_7_1691 stopfile=/tmp/14475 ================================================================================ ================================= MO Attribute Value ================================================================================ ================================= Handover=1 maxActiveSet 4 ================================================================================ ================================= Total: 1 MOs