ADRE for Windows Software (Automated Diagnostics for Rotating Equipment)
and the 208 DAIU/208-P DAIU (Data Acquisition Interface Unit) is a portable
system for multi-channel (up to 16) machinery data acquisition.

Unlike other general-purpose computer-based data acquisition systems, ADRE


for Windows is specifically designed for capturing machinery data. It is an
extremely versatile system, incorporating the features and capabilities of
oscilloscopes, spectrum analyzers, filters, and recording instruments. As a result,
this additional equipment is seldom, if ever, needed. When using the systems
real-time display capability, data is presented on the computer screen as it is
captured. For users of previous ADRE systems, ADRE for Windows is backwards
compatible with existing ADRE 3 databases.
An ADRE for Windows data acquisition and reduction system consists of:

One (or two) 208 Data Acquisition Interface Unit(s)1, 2 or

One (or two) 208-P Data Acquisition Interface Unit(s)1, 2 and


ADRE for Windows software and

A computer system capable of running ADRE for Windows software.

The systems Data Acquisition Interface Units can operate using ac or battery
power, and are fully portable, allowing convenient operation in test stands or at
machinery sites. It is highly configurable to provide support for virtually all
standard and non-standard input types including both dynamic transducer
signals (such as proximity probes, velocity transducers, accelerometers, and
dynamic pressure sensors), static signals (such as process variables from
transmitters), and Keyphasor or other speed input signals. The system also
supports multiple triggering modes for automated data acquisition, allowing it to
be used as a data or event logger without an operator present.
Notes:

1. A 208 DAIU and a 208-P DAIU may not be connected together.

2. The 208 DAIU is a predecessor to the 208-P DAIU and was designed to allow
certain older models of Compaq notebook computers to be connected directly
to the 208 using the notebooks docking port connector. A special ISA card is
also available for installation in desktop computers, allowing a 208 to be
connected. The newer 208-P allows direct connection to an enhanced parallel
port (EPP) and is supported by virtually all currently available notebook and
desktop computer systems, provided they have an EPP and it can be placed in
the EPP mode. The 208-P is recommended for all new applications; because a
208 may not be connected to a 208-P, a 208 is only required for installations in
which it must be connected to another existing 208.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 1 of 16
Across operating
Specifications temperature range:
(DAIUs) 0.47% of full-scale
range.
Typical specifications are provided for a temperature
of +25C (+77F) except where noted. Worst case 600 to 60k rpm:
specification is over the entire operating At +25C (+77F):
temperature range of 0C to +50C
0.91% of input signal
(+32F to +122F) unless specified otherwise. and 0.31% of full-scale
range.
Signal Conditioning
Direct Across operating
Measurement temperature range:
Accuracy 0.47% of full-scale
Non-RMS range.
Amplitude: RMS Amplitude,
100 to 60k rpm: Integrated:

At +25C (+77F): 100 to 600 rpm:

0.77% of input signal At +25C (+77F):


and 0.28% of full-scale 3.4% of input signal
range. and 0.31% of full-scale
Across operating range.
temperature range: Across operating
0.49% of full-scale temperature range:
range. 0.47% of full-scale
Non-RMS range.
Amplitude, 600 to 60k rpm:
Integrated:
At +25C (+77F):
100 to 60k rpm:
3.5% of input signal
At +25C (+77F): and 0.31% of full-scale
3.5% of input signal range.
and 0.28% of full-scale Across operating
range. temperature range:
Across operating 0.47% of full-scale
temperature range: range.
0.49% of full-scale Filtered
range. Measurements
RMS Amplitude: Filter
100 to 600 rpm: Bandwidth:

At +25C (+77F): Selectable in software,

2.7% of input signal 12 cpm or 120 cpm


and 0.31% of full-scale (0.2 Hz or 2.0 Hz).
range.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 2 of 16
Filter settling Integrated 1X,
time to 99% of 2X, nX Phase
final value: Accuracy
(Steady-
120 rpm bandwidth < 0.733
State)3,4,5:
seconds
100 to 600 rpm 0.0 to -38.0
12 rpm bandwidth < 7.33 seconds
600 to 10k rpm 1.0 to 8.0
1X, 2X, nX
Amplitude 10k to 60k rpm 1.0 to 7.0
Accuracy:
60k to 225k rpm 0.0 to 12.0
100 to 225k rpm:
120 rpm
At +25C (+77F): bandwidth at
500 rpm:
0.79% of input signal
and 0.21% of full-scale Amplitude ripple < 12% of input
range. signal.
Across operating Phase ripple 7.0
temperature range:
12 rpm
0.84% of input signal bandwidth at
and 0.21% of full-scale 500 rpm:
range.
Amplitude ripple < 1.2% of input
1X, 2X, nX Phase signal.
Accuracy
Phase ripple 0.7
(Steady-
State)1,2,5: Notes:
1. For n Transient:
100 to 360 rpm -5.0 to -9.0 100 rpm/s at 12 rpm BW 4.0
360 to 1440 rpm 0.0 to 3.0 100 rpm/s at 120 rpm BW 3.0
1000 rpm/s at 12 rpm BW 12.0
1440 to 10k rpm 2.0 1000 rpm/s at 120 rpm BW 7.0
(BW = bandwidth).
10k to 60k rpm 2.0 to 5.0 2. For each filter bandwidth, transient phase accuracy is
60k to 225k rpm 0.0 to +12.0 specified at two different rates of acceleration to
effectively quantify filter errors.
Integrated 1X, 3. For n Transient:
2X, nX 100 rpm/s at 12 rpm BW 5.0
Amplitude 100 rpm/s at 120 rpm BW 4.0
Accuracy: 1000 rpm/s at 12 rpm BW 13.0
1000 rpm/s at 120 rpm BW 8.0
100 to 225k rpm: (BW = bandwidth).
4. Transient phase accuracy is specified at two different
At +25 C (+77 F): rates of acceleration to effectively quantify filter
errors. Phase accuracy is dependent on the ratio of
3.50% of input signal
input signal level to the full-scale setting. Typical
and 0.21% of full-scale specifications are provided for a ratio of 1:1.
range. Maximum specifications are provided for a ratio of
0.10:1.
Across operating
5. Values are for the entire operating temperature range.
temperature range:
2.84% of input signal Dynamic Waveform Data
and 0.21% of full-scale Filtering associated with dynamic waveform data
range. pertains to anti-alias filters. Unfiltered data is used
for timebase information. Anti-alias filtered data is
used for spectrum information.
Specifications and Ordering Information
Part Number 141577-01
Rev. F (06/07)

Page 3 of 16
Unfiltered, Non- Anti-alias
Integrated Filtered, Non-
Integrated
Waveform
Amplitude: Waveform
Amplitude:
100 to 60k rpm:
1.67 Hz to 1 kHz:
At +25C (+77F):
0.86% of input and 1.92% of
0.57% of input signal
full-scale range.
and 1.42% of full-scale
range. 1 kHz to 5 kHz:
Across operating + 0.0% to -2.32% of input and
temperature range: 1.92% of full-scale range.
0.73% of input signal 5 kHz to 10 kHz:
and 1.92% of full-scale
+ 0.0% to -8.32% of input and
range.
1.92% of full-scale range.
Waveform
Anti-alias
Phase (Steady-
Filtered,
State):
Integrated
100 to 360 rpm +5.0 to +7.6
Waveform
360 to 1440 rpm +0.5 to +3.0 Amplitude:
1440 to 60k rpm 1.75 1.67 Hz to 1 kHz:
Unfiltered, 3.50% of input and 1.92% of
Integrated full-scale range.
Waveform 1 kHz to 5 kHz:
Amplitude:
3.50% to 4.32% of input and
100 to 60k rpm: 1.92% of full-scale range.
At +25C (+77F): 5 kHz to 10 kHz:
3.50% of input signal 3.50% to -10.32% of input and
and 1.42% of full-scale 1.92% of full-scale range.
range.
Gap Voltage Measurements
Across operating Amplitude:
temperature range:
At +25C (+77F):
3.50% of input signal
and 1.92% of full-scale 0.43% of input signal
range. and 79 mVdc of full-
scale range.
Waveform
Phase (Steady- Across operating
State): temperature range:
100 to 600 rpm +33.7 to +36.3 98 mVdc
600 to 10k rpm +4.75 to +7.25 Resolution:
10k to 60k rpm 3.25 12.2 mV

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 4 of 16
Measurement Resolution:
Range:
12.2 mA
0 to 25 Vdc
Measurement
Response: Range:
low-pass filter, -3dB at 0.09 Hz 0 to +40 mA
Settling time to Response:
99% of final
low-pass filter, -3dB at 0.09 Hz
value:
Settling time to
8.3 seconds
99% of final
Process Variable Measurements value:
1 to 5 Vdc, 0 to 8.3 seconds
10 Vdc Inputs
Keyphasor Inputs
Amplitude:
Keyphasor
At +25C (+77F): Signal
Conditioning
0.43% of input signal
rpm (Hz)
and 38 mVdc
Accuracy:
Across operating
100 to 12.5k rpm:
temperature range:
At +25C (+77F):
58 mVdc
0.01 % 1 rpm
Resolution:
Across operating
3.05 mV
temperature range:
Measurement
0.02 % 1 rpm
Range:
12.5k to 25k rpm:
0 to +12.5 Vdc
At +25C (+77F):
Response:
0.02 % 1 rpm
low-pass filter, -3dB at 0.09 Hz
Across operating
Settling time to
temperature range:
99% of final
value: 0.03 % 1 rpm
8.3 seconds 25k to 60k rpm:
4 to 20 mA At +25C (+77F):
Inputs
0.03 % 1 rpm
Amplitude:
Across operating
At +25C (+77F): temperature range:
0.53% of input signal 0.05 % 1 rpm.
and 152 Adc
Simulated
Across operating Keyphasor
temperature range: Accuracy:
232 Adc 100 to 60k rpm: 0.05%

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 5 of 16
Keyphasor Increment
Status accuracy:
Capabilities:
At +25C (+77F):
Error Detection: Indicated in
9.05%
software if change in shaft
rotative speed between Across operating
consecutive Keyphasor signals temperature range:
varies more than 12.5%, or if the
15.3%
detected shaft rotative speed is
less than 100 rpm or above 60k Trigger Range:
rpm.
100 rpm to 60k rpm
Keyphasor Index: Indicated in
Minimum Duty
software; this can be used to
Cycle:
position shaft at 0 reference
when machine has stopped. 0.5%
Manual Threshold mode must be
Trigger
selected.
Initiation Event:
Triggering Triggering may be initiated by
Trigger modes: exceeding a defined upper limit,
Manual or Automatic (triggers on lower limit, or both, for rpm,
negative edge of input Keyphasor amplitude, or phase. Triggering
signal). may also be initiated at a pre-
programmed date/time or by an
Auto Threshold: external contact closure (shut-
50% of peak-to-peak level, down/event detection circuit).
acquisition time is one full period The trigger initiation event
of input signal. variable is selected in software.

Manual RPM:
Threshold: External Keyphasor source,
-19.9 Vdc to +19.9 Vdc, Keyphasor 1 or 2, from 100 to

0.100 Vdc increments. 60k rpm.

Increment Amplitude:
accuracy: 1X, 2X, nX, direct, gap, process
At +25C (+77F): variable.

1.72% Phase:

Across operating 1X, 2X, or nX phase from 0 to 359


temperature range: degree phase lag.

2.05% Time:

Hysteresis: Predefined date/time.

0.2 Vdc to 2.0 Vdc, External


Contact:
0.200 Vdc increments
Shutdown/Event detection circuit,
selectable "Normally Open" or
"Normally Closed" logic.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 6 of 16
Inputs Hysteresis:
Signal Selectable within the software.
Description and (See Triggering-Hysteresis).
Quantity: Shutdown/Event
Eight signal inputs. Coaxial Detection Input
connectors at the rear panel Description:
accept displacement, velocity,
and acceleration inputs, and Connector will accept high or low
process inputs that have less than voltage input. Shutdown/Event
1 k source impedance. detection can be used for
triggering with "Normally Open"
Maximum or "Normally Closed" logic
signal input: selected in software.
25 Vdc, protected to 33.75 Vdc High Voltage:
Input 90 V to 240 V (ac or dc)
impedance:
Maximum
1 M 3% current:
Frequency 4 mA
range:
Input
dc to 10 kHz Impedance
Channel over- (High Voltage
range input to Return):
indication: 62 k 2%
Indicated in software when input Low Voltage:
signal amplitude reaches 98% (or
higher) of selected full-scale. 5V to 30V (ac or dc)

Keyphasor Maximum
current:
Description and
Quantity: 15 mA.

Two external Keyphasor inputs. Input


Connectors on rear panel will Impedance (Low
accept displacement, TTL logic Voltage input to
driver, optical driver, or tach Return):
driver outputs. 2.16 k 2%
Input Outputs
impedance:
Keyphasor/Test
24 k 1% outputs:
Maximum Two buffered, short-circuit
signal: protected signal outputs are
available on the rear panel.
-20 to +20 Vdc
Low level:
Minimum
signal: At +25C (+77F):
3.0 V peak-to-peak 0 Vdc +0.8 Vdc

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 7 of 16
Across operating Input Power
temperature range: Desktop ac
-0.2 Vdc Power Supply
High level: Input:
At +25C (+77F): 90 to 260 Vac, 47 to 64 Hz (auto-
switching)
5 Vdc +0.2 Vdc
Output:
Across operating
temperature range: 30 Vdc 5% at 1.6 A
-3.0 Vdc Battery
Logic level: Nominal Rating:
HCMOS 21.6 Vdc at 700 mA
Output Output:
impedance: At least 19.5 Vdc and not greater
< 150 over temperature range. than 36 Vdc at 1.0 A for one hour.
Note: For signal frequency accuracy Charge time:
see Keyphasor conditioning.
High Temp Battery: < 15 hours to
External fully charge.
Keyphasor Standard Battery: < 6 hours to
Source Mode: fully charge.
Keyphasor output is synchronized Discharge time
with Keyphasor input on rear (on a single
panel. Output negative edge charge):
corresponds to negative edge on
Keyphasor input signal. Pulse 4 hours typical
width follows that of input signal. Life:
Maximum delay from Keyphasor
IN signal threshold detection to 500 full charge cycles < 15%
Keyphasor OUT level transmission capacity loss.
is 10 s or 3.6 at 60k rpm. Type:
Internal Nickel-cadmium
Keyphasor
Source Mode: Low Battery
Warning:
Keyphasor output is at the
simulated Keyphasor Indicated in software, providing
programmed frequency. approximately 10 minutes of
continued operation.
Test Output:
Note: Always dispose of batteries
Output frequency is at internal properly. Do not burn or incinerate.
simulated Keyphasor frequency,
with a 50% duty cycle. Current Draw:
Input voltage of ac desktop power
module; from 26.5 to 32 Vdc.
System current draw from 400
mA to 1100 mA with battery fully
charged or disconnected.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 8 of 16
Mechanical Vector
Size Sampling:

(W x D x H): Upon sample trigger, 1X, 2X, and


nX amplitude and phase, direct,
36.8 cm x 35.6 cm x 12.7 cm rms, gap, speed, date, and time
(14.5 in x 14.0 in x 5.0 in) label are simultaneously sampled
on all active channels. These
Weight: values comprise a static data
Weight without record.
power supply: nX Vectors:
10.5 kg (23 lb) Selectable; for n > 3, integer
Weight with values from 3 to 15; for 0.100 < n
power supply: < 1, selectable in increments of
0.025.
11.2 kg (25 lb)
Waveform Set:
Environmental Limits
8/16 channels, simultaneously
Operating sampled, of synchronous and
Temperature: asynchronous waveforms, or 2/4
High Temperature Battery: 0C to channels of high resolution (3200
+50C (+32F to +122F). line) asynchronous waveforms.

Standard Battery: 0C to +40C Vector Set:


(+32F to +104F). 10 samples for 8/16 channels.
Storage Simultaneously sampled 1X, 2X,
Temperature: and nX amplitude and phase,
direct, rms, gap, speed, date and
High Temperature Battery: -30C time label.
to +50C (-22F to +122F).
Sampling Rates
Standard Battery: -20C to +40C
(-4F to +104F). Synchronous:

Relative 128 samples/rev for maximum


Humidity: speeds up to 14,999 rpm.

0% to 95% noncondensing 64 samples/rev when maximum


speed is between 15k rpm to
Approvals 29,999 rpm.
Meets European CE Mark requirements. 32 samples/rev when maximum
Sampling Specifications speed is between 30k rpm to 60k
rpm.
Sampling Ratio:
Asynchronous:
One waveform set for every
vector set (10 vector samples) 2.56 x Frequency Span
when sampling is automatically
Note: Synchronous sample rates are
triggered. Each waveform has a
based on the selected maximum
corresponding vector sample.
speed. When the maximum speed is
Data is transferred to the host
selected in software the
computer every tenth vector
corresponding synchronous sample
sample (one vector set). When a
rate is determined. The synchronous
manual sample is initiated, one
sample rate does not change during
waveform and one static data
record are taken.
Specifications and Ordering Information
Part Number 141577-01
Rev. F (06/07)

Page 9 of 16
data acquisition and will be Time
continuous over the entire database. programmability:
Aliasing Cutoff 0.10 second increments to
Frequency:
59 minutes and 59.9 seconds.
-3.0 dB at Frequency Span.
Software Specifications
160 db/decade roll-off rate. Plot Types
Aliasing Supported:
Rejection: Orbit
30.9 dB at 1.56 x Frequency Orbit/Timebase
Span
Timebase
Memory
X vs. Y (any variable vs. any
Waveform: variable)
48.4/96.8 k bytes (for 8/16 Trend
channels) of internal RAM per
waveform set. Tabular List
Maximum "Plus" Orbits
waveform Polar
samples:
Bode
256 waveforms per channel.
Shaft Centerline
Vector:
Full Spectrum
1432/2864 bytes (for 8/16
channels) of internal RAM per Half Spectrum
vector set. Cascade (using half or full
Maximum spectrum)
vector samples: Waterfall (using half or full
2560 vectors per channel. spectrum)
Sample Modes: Minimum Computer Requirements1, 2
Once triggered, sampling is based RAM:
on a change in rpm, time, or both. 32 MB
A sample may also be taken
manually. Processor:

rpm 486, 25 MHz or better


programmability: Video:
1 rpm over entire rpm range up 640 x 480 (VGA) or better
to 29,999 rpm. For speeds above
29,999 rpm, rpm must be CD-ROM:
greater than 20. Selectable for Required to load software
increasing, decreasing, or bi-
directional speed changes. Keyboard and
Sampling is based on the mouse:
selection of one of the external Required
Keyphasor sources.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 10 of 16
Operating and desktop computer systems provided they have
Systems an EPP and it can be placed in the EPP mode. The
Supported 3, 4: 208-P is recommended for all new applications;
because a 208 may not be connected to a 208-P, a
Microsoft Windows 98, 208 is only required for installations in which it must
be connected to another existing 208.
Windows NT 4.0, and 6. If your computer does not have an EPP, it may be
Windows 2000 possible to add a PCMCIA card for notebooks (BNC
p/n 02290002) or an ISA card for desktops (p/n
Enhanced 02290001). Please consult your sales professional for
Parallel Port for exact compatibility details prior to purchase.
connecting to
208-P DAIUs 5, 6: Ordering Information
Required
208/208-P Data Acquisition Interface Unit:
Free hard disk
space: Includes power cord and communication cable.
80 Mb 102351-AXX-BXX
Notes: A: Adapter Type
1. Depending on the operating system chosen, the 00 No Adapter (208 DAIU) 1
minimum computer requirements may be more 02 ISA Interface Card (208 DAIU) 2
stringent than those listed here. Consult Microsoft. 04 Enhanced Parallel Port (208-P
2. Complete computer systems are available from us. DAIU) 3
http://www.bently.com/search/dbsearch/dbview/vie Notes:
w.asp?id=e9909a30870111d3be3000805f8f09f7.
1. When two 208 DAIUs are
These systems have been selected based on high
connected together, only one
quality, performance, reliability, and world-wide
requires a computer interface.
warranty. Systems are offered with a choice of
The other 208 DAIU may use
external color monitors, laser printers, and/or portable
option 0 0 (no adapter). A 208
printers. When a complete system (Computer, DAIU,
may not be connected to a 208-
and ADRE for Windows software) is ordered from us
P.
it can be shipped with all software pre-installed and
2. The ISA interface card is used
fully tested. Contact your nearest sales professional
for interfacing a 208 DAIU to
for specifications and ordering information.
desktop computers that have
3. ADRE for Windows Versions 4.1 and earlier also
an available ISA expansion slot.
supported Windows 3.X operating systems. If 3. Enhanced Parallel Port or
upgrading to current ADRE for Windows software
available PCMCIA slot
from a previous version, it will only run on the (notebooks) or available ISA slot
operating systems indicated above, and will not run
(desktops).
on Windows 3.X.
B: Battery Types
4. We do not recommend running our software on any
version of Microsoft operating systems that we have 01 Standard Battery
not specifically tested for compatibility. Consult the 02 High Temperature Battery
factory regarding the specific version of your Note: Required communication cables
operating system and compatibility with our Bently are supplied with each 208 DAIU.
Nevada software. While we test our software with It is not necessary to order
new versions of the operating systems listed, we may additional cables when ordering
not have always tested the most recent version of multiple 208 DAIUs.
certain operating systems before they are released by
Microsoft. ADRE for Windows Software
5. The 208 DAIU is a predecessor to the 208-P DAIU and
was designed to allow certain older models of
Distributed on CD-ROM only. Includes program CD-
Compaq notebook computers to be connected ROM and printed Quick Start Guide.
directly to the 208 using the notebooks docking port 109579 - AXX-BXX-CXX-DXX
connector. A special ISA card is also available for
A: ADRE for Windows Software
installation in desktop computers, allowing a 208 to
be connected. The newer 208-P allows direct
00 No component
connection to an enhanced parallel port (EPP) and is 01 ADRE for Windows
supported by virtually all currently available notebook 02 ADRE for Windows update

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 11 of 16
03 ADRE for Windows purchases are added together
enhancement/upgrade for a total support period.
B: ADRE for Windows Software for display only
00 No component Accessories
01 ADRE for Windows display 136208-01
only
02 ADRE for Windows display MachineLibrary Multimedia
only update. Training Software
03 ADRE for Windows display
only enhancement/ upgrade 208 Upgrade Kits
05 5 user license 134559-01
10 10 user license
20 20 user license This kit is used to upgrade a
C: ADRE for Windows printed Quick Start Guide 208 DAIU (that already has the
00 No component CE mark) to a 208-P DAIU with
01 ADRE for Windows Quick CE mark. The CE mark is
Start Guide located on the rear panel.
D: Machine Library CBT 134559-02
00 No component This kit is used to upgrade a
01 BN Machine Library CBT 208 DAIU (that does NOT
already have the CE mark) to a
ADRE for Windows Software Support Plans: 208-P DAIU with CE mark. The
1374/20-A-XX CE mark is located on the rear
panel.
A: Support type and duration1,4 107303-01
01 1 year single 2 software
package. DAIU hard shipping case
02 1 year multi-software 3 102358-01
package. DAIU soft carry case
03 2 year single software 129043-01
package.
04 2 year multi-software 208 DAIU ISA interface card
package. 02290001
05 3 year single software
ISA enhanced parallel port
package.
card
06 3 year multi-software
02290002
package.
07 4 year single software PCMCIA enhanced parallel
package. port
08 4 year multi-software 80917-01
package.
TK15 Keyphasor
09 5 year single software
Conditioner/Power Supply
package.
29654-01
10 5 year multi-software package.
Notes: Patch Panel
1. 1 year support plan is provided 10798-03
with initial purchase of ADRE for
Windows software. Optical pickup sensor
2. Single is for users with a single 20545-25
copy of software.
3. Multi is for users with multiple Optical pickup cable
copies of software. 20211-05
4. If an additional support plan is
Optical pickup mounting
purchased with the initial
software purchase, the two
package. Includes: mounting
pliers, magnetic base, and
gooseneck transducer holder.
Specifications and Ordering Information
Part Number 141577-01
Rev. F (06/07)

Page 12 of 16
02290050 5 1.8 metre (72 inch) banana
cable - Yellow
Reflective tape roll
5 1.8 metre (72 inch) banana
102357-01
cable - Green
Field Connection Kit Includes: 5 1.8 metre (72 inch) banana
10 BNC receptacle to double cable - Blue
banana plug
4 BNC receptacle to alligator ADRE Computer System
test clip 109580 AXX-BXX-CXX-DXX-EXX
4 BNC T-connector
10 BNC 90 connector A: Computer
10 BNC receptacle to single 00 No component
banana plug 06 Notebook (Windows 2000)
4 BNC receptacle to double B: Monitor
banana plug 00 No component
10 Single binding post to BNC 01 17 inch monitor
plug C: Mouse
10 Banana jack to alligator clip 00 No component
4 Double binding post to BNC 01 Microsoft mouse
plug D: Printer
6 BNC union 00 No component
10 1.8 metre (72 inch) BNC coaxial 01 110V HP Laserjet Printer
cable 02 220 V HP Laserjet Printer
5 1.8 metre (72 inch) banana 03 HP Deskjet Portable
cable - Black E:
5 1.8 metre (72 inch) banana 00 No component
cable - Red 01 keyboard & Convenience base

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 13 of 16
Tables and Figures

Table 1: Scale Factor Options for Supported Input Types

Scale Factor Units Minimum Maximum


mV/mil 8 400
mV/ in 0.2 6
mV/mm 200 10,000
Displacement mV/ m 0.2 10
REBAM mV/ m 0.2 240
mV/in/s 40 2,000
mV/mm/s 1 50
mV/g 4 200
mV/g 80 200
(if units are integrated in/s)
mV/m/s2 0.4 20
mV/m/s2 5 20
(if units are integrated
mm/s)
mV/any unit Allowable scale factor selection is based on a combination of desired
(generic dynamic) full-scale range and measurement type, (e.g., pp, pk, rms).
Ib ft Scale factors are based on selected full-scale range and are not
editable.
Nm Scale factors are based on selected full-scale range and are not
editable.
mV/ Scale factors are based on selected full-scale range and are not
editable.
Any process variables Scale factors are calculated based on full-scale range and are not
editable.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 14 of 16
Table 2: Full-Scale Range Selection for Supported Input Types

Units Full-Scale Range Selection


mil pp 2.00 5.00 10.00 20.00 50.00 100.00 200.00 500.00
in pp 20.00 50.00 100.00 200.00 500.00
mm pp 0.10 0.20 0.50 1.00 2.00 5.00 10.00 20.00 50.00
m pp 1.00 2.00 5.00 10.00 20.00 50.00 100.00 200.00 500.00
1000.00 2000.00 5000.00 10000.0
0
in/s pk 0.20 0.50 1.00 2.00 5.00
in/s rms 0.10 0.20 0.50 1.00 2.00
mm/s pk 5.00 10.00 20.00 50.00 100.00 200.00
mm/s rms 2.00 5.00 10.00 20.00 50.00 100.00
integrated mil 2.00 5.00 10.00 20.00 50.00
pp
integrated mm 0.10 0.20 0.50 1.00 2.00
pp
integrated m 50.00 100.00 200.00 500.00 1000.0 2000.00
pp 0
g pk 2.00 5.00 10.00 20.00 50.00
g rms 1.00 2.00 5.00 10.00 20.00
m/s2 pk 20.00 50.00 100.00 200.00 500.00

m/s2 rms 10.00 20.00 50.00 100.00 200.00


integrated in/s 2.00 5.00
pk
integrated in/s 2.00 5.00
rms
integrated 50.00 100.00 200.00
mm/s pk
integrated 50.00 100.00 200.00
mm/s rms
lb ft 1000 2000 5000 10000 20000 50000 10000
0
Nm 1000 2000 5000 10000 20000 50000 10000
0
Degree 0.50 1.00 2.00
Any generic Allowable full-scale range selection is based on a combination of scale factor and
dynamic measurement type,
(e.g., pp, pk, rms)
Any process Process variable full-scale range can be from -999,999 to +999,999. Scale factors are
variable automatically calculated depending on the selection of full-scale range.
Note: Choice of full-scale range selection may depend on transducer type. Not all full-scale ranges are applicable to
every transducer type.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 15 of 16
Figure 1: Front and Rear Views of 208-P DAIU

Bently Nevada, ADRE, Keyphasor and MachineLibrary are trademarks of General Electric Company.
Windows is a registered trademark of Microsoft Corporation.
Compaq is a registered trademark of Hewlett-Packard Development Company, L.P.

Copyright 2000. Bently Nevada LLC.


1631 Bently Parkway South, Minden, Nevada USA 89423
Phone: 775.782.3611 Fax: 775.215.2873
www.ge-energy.com/bently
All rights reserved.

Specifications and Ordering Information


Part Number 141577-01
Rev. F (06/07)

Page 16 of 16