2
TAPERED CELLS: Unique
INLET SCREEN: Four-mesh engineering design controls
galvanized inlet screen keeps airflow for efficient dirt removal
out large debris. BLEED SLOT: Rounded bleed air
at lowest pressure drop. slot entry is an integral part of the
dust pan. The rounded slot
minimizes obstruction or plugging
even under the worst conditions.
All components are primed and finished with a top coat of gray enamel.
3
Performance
Airflow resistance
4
HEIGHT (H) FLANGE WIDTH
Single Cell - 24.00 (609.6 mm) 1DV & 2DV - 1.5 (38.1 mm) DEPTH (D)
Double Cell - 47.94 (1217.7 mm) 3DV - 2.0 (50.8 mm) Single Cell - 25.50 (647.7 mm)
Triple Cell - 71.88 (1825.8 mm) Double Cell - 30.50 (774.7 mm)
Triple Cell - 35.50 (901.7 mm)
A D
B
1.5
(38.1 mm) Left Hand Bleed (BL) Right Hand Bleed (BR)
Center Bleed (BC)
Note: See sales drawings 125557 (1DV), 12555 (2DV) and
400987 (3DV) for respective sizes and detailed dimensions.
Multi-Cell Banks
For higher airflow, or to fit special physical requirements, multi-cell Dynavane banks may be the solution. Four basic
arrangements are offered ranging from 10 to 112 cells. All cells are horizontally inclined and incorporate a side plenum,
discharging bleed air down. These banks can be grouped to accommodate even higher airflow than shown. Bleed
manifolds are sized for suction system utilizing bleed blowers. Do not use multi-cell banks on pressure systems.
Height
Ordering Information
Specify number 045496-000 and size from the charts on the next two pages.
On arrangements 1 and 2, also specify right or left-hand bleed. Arrangments 3 and 4 are center bleed.
See sales drawing 045496 for detail.
5
Dimensions & Capacities Dynavane
Airflow (cfm) at Various Dynavane Pressure Drops Dimensions (inches)
Number
Model of 0.75 w.g. 1.0 w.g. 1.25 w.g. Weight
Designation Cells A B C (lbs)
Wide Clean Bleed Clean Bleed Clean Bleed
1 810 90 935 104 1060 118 5.75 4.62 4.25 110
2 1620 180 1870 208 2120 236 10.75 5.25 6.31 168
3 2430 270 2805 312 3180 353 15.75 5.94 7.88 226
4 3240 360 3740 416 4240 471 20.75 6.81 8.81 284
5 4050 450 4675 519 5300 589 25.75 7.69 9.62 342
6 4860 540 5610 623 6360 707 30.75 8.62 10.38 400
7 5670 630 6545 727 7420 824 35.75 9.50 11.06 458
8 6480 720 7480 831 8480 942 40.75 10.44 11.75 516
1DV 9 7290 810 8415 935 9540 1060 45.75 11.38 12.38 574
Single 10 8100 900 9350 1039 10600 1178 50.75 12.31 12.94 632
Cell 11 8910 990 10285 1143 11660 1296 55.75 13.25 13.44 690
High 12 9720 1080 11220 1247 12720 1413 60.75 14.19 14.00 748
13 10530 1170 12155 1351 13780 1531 65.75 15.19 14.50 806
14 11340 1260 13090 1454 14840 1649 70.75 16.12 15.00 864
15 12150 1350 14025 1558 15900 1767 75.75 17.12 15.44 922
16 12960 1440 14960 1662 16960 1884 80.75 18.06 15.88 980
17 13770 1530 15895 1766 18020 2002 85.75 19.03 16.31 1038
18 14580 1620 16830 1870 19080 2120 90.75 20.00 16.75 1096
19 15390 1710 17765 1974 20140 2238 95.75 20.97 17.19 1154
20 16200 1800 18700 2078 21200 2356 100.75 21.94 17.56 1212
1 1620 180 1870 208 2120 236 5.75 4.62 4.25 233
2 3240 360 3740 416 4240 471 10.75 5.19 6.50 342
3 4860 540 5610 623 6360 707 15.75 5.75 8.88 451
4 6480 720 7480 831 8480 942 20.75 6.31 11.25 50
5 8100 900 9350 1039 10600 1178 25.75 7.00 12.94 669
6 9720 1080 11220 1247 12720 1413 30.75 7.81 14.00 778
7 11340 1260 13090 1454 14840 1649 35.75 8.69 15.00 887
8 12960 1440 14960 1662 16960 1884 40.75 9.56 15.88 996
2DV 9 14580 1620 16830 1870 19080 2120 45.75 10.44 16.75 1105
Double 10 16200 1800 18700 2078 21200 2356 50.75 11.31 17.56 1214
Cell 11 17820 1980 20570 2286 23320 2591 55.75 12.25 18.31 1323
High 12 19440 2160 22440 2493 25440 2827 60.75 13.12 19.06 1432
13 21060 2340 24310 2701 27560 3062 65.75 14.06 19.75 1541
14 22680 2520 26180 2909 29680 3298 70.75 14.94 20.50 1650
15 24300 2700 28050 3117 31800 3533 75.75 15.88 21.12 1759
16 25920 2880 29920 3324 33920 3769 80.75 16.81 21.75 1868
17 27540 3060 31790 3532 36040 4004 85.75 17.75 22.38 1977
18 29160 3240 33660 3740 38160 4240 90.75 18.69 23.00 2086
19 30780 3420 35530 3948 40280 4476 95.75 19.62 23.56 2195
20 32400 3600 37400 4156 42400 4711 100.75 20.56 24.12 2304
1 2430 270 2805 312 3180 353 5.75 4.75 4.25 360
2 4860 540 5610 623 6360 707 10.75 5.25 6.75 535
3 7290 810 8415 935 9540 1060 15.75 5.75 9.00 710
4 9720 1080 11220 1247 12720 1413 20.75 6.50 11.50 885
5 12150 1350 14025 1558 15900 1767 25.75 7.00 14.00 1060
6 14580 1620 16830 1870 19080 2120 30.75 7.50 16.25 1235
7 17010 1890 19635 2182 22260 2473 35.75 8.25 18.00 1410
8 19440 2160 22440 2493 25440 2827 40.75 9.00 19.00 1585
3DV 9 21870 2430 25245 2805 28620 3180 45.75 10.00 20.25 1760
Triple 10 24300 2700 28050 3117 31800 3533 50.75 10.75 21.25 1895
Cell 11 26730 2970 30855 3428 34980 3887 55.75 11.74 22.25 2110
High 12 29160 3240 33660 3740 38160 4240 60.75 12.50 23.00 2285
13 31590 3510 36465 4052 41340 4593 65.75 13.50 23.75 2460
14 34020 3780 39270 4363 44520 4947 70.75 14.25 24.75 2635
15 36450 4050 42075 4675 47700 5300 75.75 15.00 25.50 2810
16 38880 4320 44880 4987 50880 5653 80.75 16.00 26.25 2985
17 41310 4590 47685 5298 54060 6007 85.75 17.00 27.00 3160
18 43740 4860 50490 5610 57240 6360 90.75 17.75 27.75 3335
19 46170 5130 53295 5922 60420 6713 95.75 18.75 28.50 3510
20 48600 5400 56100 6233 63600 7067 100.75 19.50 29.25 3685
6
Arrangement 1 Arrangement 2 Arrangement 3 Arrangement 4
Note: Intake system loss calculations should be based Note: See table on page 6 for 1DV, 2DV, and 3DV,
on inlet airflow, which is the sum of the clean and
Dynavane dimensions.
bleed airflow. In the example above, it would be 1110
cfm.
On the pages 6 and 7, the various Dynavane configurations are listed. A few simple steps will provide the information
needed to select the one best suited to your installation.
1. Determine the airflow required and the airflow resistance acceptable to the application.
2. On the charts on pages 6 and 7, look up the Dynavane model which will provide the necessary airflow at the
resistance selected.
3. Various sizes (example: six single-cell or three double-cell) meet similar airflow requirements. After comparing the
dimensional information, order the model which fits the applications space requirements. 7
SPECIFICATIONS Dynavane
Air cleaners shall be Camfil Farr Dynavane BULLNOSE The bullnose shall be
inertial separators They shall be factory fabricated aerodynamically formed of 16-gauge steel to
and assembled. Each air cleaner shall consist of provide proper air entry. One bullnose will be
a housing, a bleed air manifold, cell bodies, blade required for each two blade pack to properly
packs, bullnoses, and inlet screen. All finished direct air to each tapered cell. Bullnose clamps
components are primed and finished with a top shall be constructed of 0.19 (4.83 mm) steel
coat of gray enamel. The Dynavane shall consist and shall be retained by 5/16 threaded stock
of one or more cells depending on airflow and welded to the center divider. Center dividers shall
resistance requirements. Individual cells shall be constructed of 16-gauge steel.
include two removable blade packs and have a
maximum center-to-center (width) dimension of 5 BLEED SLOT Bleed slots shall be an integral
(127 mm) and shall be 24 (610 mm) in length. part of each dust bin. The bleed slot/dust bin shall
be constructed of not less than 16-gauge steel.
HOUSING Housings shall be constructed of The bleed slot shall have a rounded entry
not less than 11-gauge steel. The housing shall configuration to minimize obstruction or plugging
be of all welded construction and equipped with under heavy dust concentrations.
continuous standing flanges around the periphery
of both the air entering and the air exiting sides. INLET SCREEN Inlet screens shall consist of
Flanges shall have pre-drilled bolt holes to a 26-gauge, four-mesh, galvanized hardware
facilitate field installation. cloth integrally supported by a double layered 16-
gauge galvanized steel frame. Inlet screens shall
BLEED AIR MANIFOLD Housings shall be be bolted to the Dynavane housing.
equipped with a bleed air manifold constructed of
not less than 11-gauge steel all welded steel EFFICIENCY When tested in accordance with
construction and equipped with continuous the general requirements outlined in SAE J726,
standing flange with pre-drilled bolt holes to the Camfil Farr Dynavane air cleaner efficiency
facilitate field connection. Manifolds shall be sized shall not be less than 93% on Standardized
to provide uniform airflow through each cells dust Coarse Air Cleaner Test Dust at a clean airflow
bin for proper balance and dust removal. rate of 1000 CFM (1700 m3/h) per single cell
using a bleed rate equaling 10% of inlet airflow.
BLADE PACKS - Blade packs shall be Inlet to clean air outlet resistance shall not
constructed of not less than 20-gauge steel with exceed 1.20" w g. (0.30 kPa) at 1000 CFM (1700
Heli-arc welded construction. Blade pack vanes m3/h) clean airflow.
shall be individually formed and welded. Vanes
shall be arranged to provide a circuitous path to
the air flow and redirect the air toward the clean
air outlet. The air passageway between adjacent
blades shall have a minimum width of 0.19 (4.83
mm). Blade packs shall be removable to allow for
inspection or service.