Anda di halaman 1dari 2

X-flow XIGA 46

Ultrafiltration Membrane
Membrane element datasheet

XIGA HP
ARTICLE CODE : 2872FL895A

General information CLEANING chemical Resistance

Xiga 46 is used for process and potable Sodium Hypochlorite As a good working practice and in order to
water filtration. Mode of operation is dead- - Typical 200 ppm, at 40 C at pH 10 maximise the lifetime of the membrane it is
end with regular backwash (permeate only) - Maximum 500 ppm advised to reduce the membrane exposure
and chemically enhanced backwash. Typical - 250.000 ppm hours cumulative; pH 10 to oxidising agents to a minimum. Exposure
applications are the filtration of surface limits are also affected by temperature,
Chlorine Dioxide
water, large-scale drinking and process pH and the presence of metals. In order
- Typical 1 ppm, at 40 C
water production. not to exceed maximum exposure limits,
- Maximum 2 ppm
membranes must be preserved free of any
- 90.000 ppm hours cumulative; pH 11
oxidising agent when the plant is stopped.
general Solvent resistance Hydrogen Peroxide
Acids
- Typical 200 ppm, at 40 C
Hydrochloric Acid ++
- Maximum 500 ppm
Since the resistance of the membrane to Nitric Acid ++
- 350.000 ppm hours cumulative
solvents strongly depends on the actual Phosphoric Acid ++
process conditions, the indications given Note: Acetic Acid ++
below should only be considered as The above figures for oxidant contact Citric Acid ++
guideline. represent the membrane resistance to
pH > 2 during filtration
each individual oxidizing agent. The total
Acids ++ pH > 1 during cleaning
combined exposure for Sodium Hypochlorite
Bases ++
and Chlorine Dioxide will be calculated as Bases
Aliphatic alcohols +
follows: Sodium Hydroxide (<4%) ++
Aliphatic hydrocarbons +
Potassium Hydroxide (<4%) + +
Halogenated hydrocarbons -- Combined exposure (NaOCl + ClO2) = 2.6 x
Aromatic hydrocarbons -- Exposure to ClO2 (in ppm hours)+ Exposure pH < 12 during filtration
Polar organic solvents -- to NaOCl (in ppm hours) < 250.000 ppm pH < 13 during cleaning
Oils ++ hours.

Membrane Characteristics element specifications

Hydrophilic membrane composed of Hydraulic Permeate Element


a blend of polyvinylpyrrolidone and Membrane Element
membrane collector inner outer
area length L0
polyethersulfone diameter diameter d0 diameter D0
[m/ft] [mm/Inch]
A nominal pore size of 20 nm [mm/mil] [mm/Inch] [mm/Inch]
Structure asymmetric/microporous 0.9 [35] 46 [495] 1527.5 [60.14] 42.6 [1.68] 200 [7.9]
High performance and a very good anti-
fouling behaviour
Typical permeate quality SDI<3, turbidity
<0,1 NTU
Burst pressure: >14 bar
Collapse ressure: >10 bar
Membrane filtration provides 99.9999%
(LOG6) reduction of bacteria (Pseudomonas
diminuta) and 99.99% (LOG 4) reduction of
virus (MS2 colifages) by mechanical means.
EPA Est. No. 090374-NLD-001

Advanced Filtration XIGA 46


X-flow XIGA 46
Ultrafiltration Membrane
Membrane element datasheet

Operating Specifications Technical Specifications Storage

Weight Specifications New membrane modules can be stored


Max. trans- Max.
Temp. Dry weight of membrane element as supplied in the original packaging. The
membrane backflush
range ca. 25 kg [55 lbs] membrane elements contain an aqueous
pressure pressure
preservation solution of glycerine (20wt%)
[kPa/psi] [kPa/psi] [C/F] Membrane element filled with water
and sodium metabisulfite (1wt%).
ca. 55 kg [121 lbs]
300 300 0-40 Membrane modules should be stored in a
[43] [43] [32-104] Materials of Construction
dry, normally ventilated place, away from
Housing PVC white
sources of heat, ignition and direct sunlight.
Max. system pressure: see specifications Flow distributor PVC
Store between 0 and 40 C.
of membrane housing supplier Potting PU resin
Membrane PES/PVP The membrane modules should not be
Backwash water should be free of subjected to any freezing temperatures.
particulates and should be of UF permeate Process Characteristics
quality or better This element type is used for dead-end Shelf life is a maximum of 6 months for
applications. unused modules in unopened packaging
Backwash pumps should preferably be under correct storage conditions after
made of non-corroding materials, e.g., transfer of ownership for X-Flow B.V. to
plastic or stainless steel. If compressed the Client. After the maximum period of 6
air is used to pressurize the backwash
certifications
months all warrantees are null and void
water, do not allow a two-phase air/water unless otherwise agreed in writing between
mixture to enter the element USA: ANSI/NSF, Standard 61 the parties.
To avoid mechanical damage, do not Germany: Accredited under DVGW, W270 After use, the UF membrane modules
subject the membrane module or need to be stored wet at all times.To avoid
element to sudden temperature changes, The Netherlands: KIWA ATA
biological growth during shutdowns or
particularly decreasings. Do not exceed 40 France: ACS storage, wet membranes could be treated
C process temperature. Bring the module with a compatible biocide. The membrane is
or element back to ambient operating USA: CDPH
compatible with many common disinfecting
temperature slowly (max. value 3 C/min). United Kingdom: DWI, Regulation 31 agents or biocidal preservatives.
Failure to adhere to this guideline can
result in irreparable damage Typically for short-term shutdowns (1 7
days), a daily backwash with UF permeate
Operation of membrane modules at any quality water for 30 seconds at 215 lmh,
combination of maximum limits of pH, should be adequate for bacteria control.
concentration, pressure or temperature, Before start of the shutdown period, the
during cleaning or production, will influence modules must be cleaned by a standard
the membrane lifetime. Chemical Enhanced Backwash (CEB).
In case of long-term storage (> 7 days),
membranes should be disinfected. The
membranes should be cleaned using a CEB
before the disinfection step is carried out.
For disinfection, a 0,5% sodium metabisulfite
solution can be used. In both short and long
term storage situations, the modules should
remain filled with storage solution.

X-FLOW BV
P.O. Box 739, 7500 AS Enschede, Netherlands WWW.x-flow.com
Note: The information and data contained in this document are based on our general experience and are believed to be correct. They are given in good faith
and are intended to provide a guideline for the selection and use of our products. Since the conditions under which our products may be used are beyond our
control, this information does not imply any guarantee of final product performance and we cannot accept any liability with respect to the use of our products. The
quality of our products is guaranteed under our conditions of sale. Existing industrial property rights must be observed. Replaces: CAPF-XIGA-SXL225-PVC_1214
DS XIGA 46 EN 0415 2015 Pentair. All Rights Reserved. ISO 9001