PC815 Serise

High Sensitivity, High Density


PC815 Series Mounting Type Photocoupler
Lead forming type ( I type ) and taping reel type ( P type ) are also available. ( PC815I/PC815P )
..
TUV ( VDE0884 ) approved type is also available as an option.
Features Applications
1. High current transfer ratio 1. System appliances, measuring instruments
( CTR: MIN. 600% at I F = 1mA, V CE = 2V) 2. Industrial robots
2. High isolation voltage between input and 3. Copiers, automatic vending machines
output 4. Signal transmission between circuits of
( Viso : 5 000V rms ) different potentials and impedances
3. Compact dual-in-line package
PC815 : 1-channel type PC825 : 2-channel type
PC835 : 3-channel type PC845 : 4-channel type
4. Recognized by UL file No. E64380

Outline Dimensions ( Unit : mm )


PC815 PC825

Anode mark
2.54 0.25 Internal connection
Internal connection diagram
Anode mark

2.54 0.25 diagram


4 3 4 3 8 7 6 5
8 7 6 5
1 Anode
PC815

PC815

PC815
6.5 0.5

6.5 0.5
2 Cathode
3 Emitter
4 Collector
1 2 1 2 1 2 3 4 1 2 3 4
0.9 0.2 0.9 0.2 1 3 Anode
1.2 0.3 1.2 0.3 2 4 Cathode
5 7 Emitter
4.58 0.5 7.62 0.3 7.62 0.3 6 8 Collector
3.5 0.5

9.66 0.5
0.5TYP.

3.5 0.5
2.7 0.5

0.5TYP.

2.7 0.5

0.26 0.1
3.0 0.5

0.26 0.1
3.0 0.5

0.5 0.1
0.5 0.1
= 0 to 13 = 0 to 13
Internal connection diagram
PC835 PC845
16 15 14 13 12 11 10 9
1 3 5 7 Anode
Anode mark

Internal connection
2.54 0.25 2 4 6 8 Cathode
diagram
12 11 10 9 8 7 9 11 13 15 Emitter
12 11 10 9 8 7
10 12 14 16 Collector
1 2 3 4 5 6 7 8
PC815

PC815

PC815

6.5 0.5

Anode mark

2.54 0.25
16 15 14 13 12 11 10 9
1 2 3 4 5 6 1 2 3 4 5 6
PC815

PC815

PC815

PC815

6.5 0.5

0.9 0.2 1 3 5 Anode


1.2 0.3 2 4 6 Cathode
7 9 11 Emitter
8 10 12 Collector 1 2 3 4 5 6 7 8
0.9 0.2
14.74 0.5 7.62 0.3 1.2 0.3
3.0 0.5 3.5 0.5
0.5TYP.

19.82 0.5 7.62 0.3


2.7 0.2

3.0 0.5 3.5 0.5


0.5TYP.

2.7 0.5

0.26 0.1
0.26 0.1
0.5 0.1

0.5 0.1
= 0 to 13 = 0 to 13

In the absence of confirmation by device specification sheets, SHARP takes no responsibility for any defects that occur in equipment using any of SHARP's devices, shown in catalogs,
data books, etc. Contact SHARP in order to obtain the latest version of the device specification sheets before using any SHARP's device.
PC815 Series

Absolute Maximum Ratings ( Ta = 25C )


Parameter Symbol Rating Unit
Forward current IF 50 mA
*1
Peak forward current I FM 1 A
Input
Reverse voltage VR 6 V
Power dissipation P 70 mW
Collector-emitter voltage V CEO 35 V
Emitter-collector voltage V ECO 6 V
Output
Collector current IC 80 mA
Collector power dissipation PC 150 mW
Total power dissipation P tot 200 mW
*2
Isolation voltage V iso 5 000 V rms
Operating temperature T opr - 30 to + 100 C
Storage temperature T stg - 55 to + 125 C
*3
Soldering temperature T sol 260 C
*1 Pulse width<=100 s, Duty ratio : 0.001
*2 40 to 60% RH, AC for 1 minute
*3 For 10 seconds
Electro-optical Characteristics ( Ta = 25C )
Parameter Symbol Conditions MIN. TYP. MAX. Unit
Forward voltage VF I F = 20mA - 1.2 1.4 V
Peak forward voltage V FM I FM = 0.5A - - 3.0 V
Input
Reverse current IR V R = 4V - - 10 A
Terminal capacitance Ct V = 0, f = 1kHz - 30 250 pF
Output Collector dark current I CEO V CE = 10V, I F = 0 - - 10 - 6 A
Current transfer ratio CTR I F = 1mA, V CE = 2V 600 - 7 500 %
Collector-emitter saturation voltage V CE(sat) I F = 20mA, I C = 5mA - 0.8 1.0 V
Transfer Isolation resistance R ISO DC500V, 40 to 60% RH 5 x 10 10 10 11 -
charac- Floating capacitance Cf V = 0, f = 1MHz - 0.6 1.0 pF
teristics Cut-off frequency fc V CE = 2V, I C = 2mA, R L = 100 1 6 - kHz
Rise time tr - 60 300 s
Response time V CE = 2V, I C = 10mA, R L = 100
Fall time tf - 53 250 s

Fig. 1 Forward Current vs. Fig. 2 Collector Power Dissipation vs.


Ambient Temperature Ambient Temperature
60 200
Collector power dissipation PC ( mW )

50
Forward current I F ( mA )

150
40

30 100

20
50
10

0
0
- 30 0 25 50 75 100 125 - 30 0 25 50 75 100 125
Ambient temperature Ta ( C ) Ambient temperature Ta ( C )
PC815 Series

Fig. 3 Peak Forward Current vs. Duty Ratio Fig. 4 Forward Current vs. Forward Voltage

10 000
Pulse width <=100s 500
T a = 75C
5 000 T a = 25C
200
50C 25C
2 000
Peak forward current I FM ( mA )

100 0C

Forward current IF ( mA )
1 000
50 - 25C
500
20
200
100 10

50 5

20 2
10 1
5
5 10 -3 2 5 10 -2 2 5 10 -1 2 5 1 0 0.5 1.0 1.5 2.0 2.5 3.0 3.5

Duty ratio Forward voltage V F ( V )

Fig. 5 Current Transfer Ratio vs. Fig. 6 Collector Current vs.


Forward Current Collector-emitter Voltage
2 000 100
V CE = 2V
Current transfer ratio CTR ( % )

1 800 90 Ta = 25C
T a = 25C
1 600 80
I F = 10mA
Collector current I C ( mA )

1 400 70
P C ( MAX. )
1 200 60

1 000 50 5mA

800 40
2mA
600 30

400 20 1mA

200 10
0 0
0.1 0.2 0.5 1 2 5 10 0 1 2 3 4 5
Forward current I ( mA ) Collector-emitter voltage V CE (V)
F

Fig. 7 Relative Current Transfer Ratio vs. Fig. 8 Collector-emitter Saturation Voltage
Ambient Temperature vs. Ambient Temperature
Collector-emitter saturation voltage VCE(sat) ( V )

150 1.3
I F = 1mA I F = 20mA
1.2
I C = 5mA
V CE = 2V 1.1
Relative current transfer ratio ( % )

1.0
0.9
100
0.8
0.7
0.6
0.5
50
0.4
0.3
0.2
0.1
0 0
- 30 0 25 50 75 100 - 30 0 25 50 75 100
Ambient temperature T a ( C ) Ambient temperature T a ( C )
PC815 Series

Fig. 9 Collector Dark Current vs. Fig.10 Response Time vs. Load Resistance
Ambient Temperature
10 - 4 500 V CE = 2V
V CE = 10V I C = 10mA
10 -5 T a = 25C
200
tr
Collector dark current I CEO ( A )

10 - 6 100
tf

Response time ( s )
-7 50
10

10 - 8 20
td
10
10 -9

5
- 10 ts
10

10 - 11 2
10 - 12 1
- 30 0 20 40 60
80 100 0.05 0.1 0.2 0.5 1 2
Ambient temperature T a ( C) Load resistance RL ( k )

Fig.11 Frequency Response


Test Circuit for Response Time

V CE = 2V
I C = 2mA
0 T a = 25C VCC Input
Output
Voltage gain A v ( dB )

Input RD RL
10%
Output
90%
td ts
- 10 RL = 10K 1k 100 tr tf

- 20
0.02 0.05 0.1 0.2 0.5 1 2 5 10 20 50 100
Frequency f ( kHz )

Fig.12 Collector-emitter Saturation Voltage vs.


Forward Current Test Circuit for Frepuency Response
8
I C = 0.5mA T a = 25C
7
1mA
Collector-emitter Saturation Voltage

VCC
6 3mA
5mA RL
5
VCE (sat) (V)

7mA RD Output
4
50mA
3

2
30mA
1

0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 4.0
Please refer to the chapter
Forward current I F ( mA ) Precautions for Use
Application Circuits

NOTICE
The circuit application examples in this publication are provided to explain representative applications of
SHARP devices and are not intended to guarantee any circuit design or license any intellectual property
rights. SHARP takes no responsibility for any problems related to any intellectual property right of a
third party resulting from the use of SHARP's devices.
Contact SHARP in order to obtain the latest device specification sheets before using any SHARP device.
SHARP reserves the right to make changes in the specifications, characteristics, data, materials,
structure, and other contents described herein at any time without notice in order to improve design or
reliability. Manufacturing locations are also subject to change without notice.
Observe the following points when using any devices in this publication. SHARP takes no responsibility
for damage caused by improper use of the devices which does not meet the conditions and absolute
maximum ratings to be used specified in the relevant specification sheet nor meet the following
conditions:
(i) The devices in this publication are designed for use in general electronic equipment designs such as:
--- Personal computers
--- Office automation equipment
--- Telecommunication equipment [terminal]
--- Test and measurement equipment
--- Industrial control
--- Audio visual equipment
--- Consumer electronics
(ii)Measures such as fail-safe function and redundant design should be taken to ensure reliability and
safety when SHARP devices are used for or in connection with equipment that requires higher
reliability such as:
--- Transportation control and safety equipment (i.e., aircraft, trains, automobiles, etc.)
--- Traffic signals
--- Gas leakage sensor breakers
--- Alarm equipment
--- Various safety devices, etc.
(iii)SHARP devices shall not be used for or in connection with equipment that requires an extremely
high level of reliability and safety such as:
--- Space applications
--- Telecommunication equipment [trunk lines]
--- Nuclear power control equipment
--- Medical and other life support equipment (e.g., scuba).
Contact a SHARP representative in advance when intending to use SHARP devices for any "specific"
applications other than those recommended by SHARP or when it is unclear which category mentioned
above controls the intended use.
If the SHARP devices listed in this publication fall within the scope of strategic products described in the
Foreign Exchange and Foreign Trade Control Law of Japan, it is necessary to obtain approval to export
such SHARP devices.
This publication is the proprietary product of SHARP and is copyrighted, with all rights reserved. Under
the copyright laws, no part of this publication may be reproduced or transmitted in any form or by any
means, electronic or mechanical, for any purpose, in whole or in part, without the express written
permission of SHARP. Express written permission is also required before any use of this publication
may be made by a third party.
Contact and consult with a SHARP representative if there are any questions about the contents of this
publication.

115

Anda mungkin juga menyukai