Main features
Up to 24 kW installed power
Modular structure to match different needs
Fan cooled rectifiers
DPR 1200B-48 or FR 48 V 2000 W - E
Hot pluggable, all connectors at the rear
Efficiency 91%
LVD option
PLD option
Power system controller PSC 3 or PSC 1000
Applications
Medium to high power systems
Wireless base stations
Core network components
Telecommunications/data networks
Description
The DPS 1200B_2000B-48-n ETS is a compact power
system for power up to 24 kW. The design is based on
modular structure, making the system an excellent
solution for many different needs and applications.
The system has options for rectifiers, AC connections,
battery connections, LVDs, PLDs and load connections,
as well as for the brain of the system, the controller.
The system is built in an ETSI standard cabinet
requiring floor space of only 600 mm x 600 mm, having
different heights as an option. Also the battery shelves
can be integrated to this compact and powerful system.
The typical applications are wireless base stations and
core network components, as well as telecommunication
and data networks. This compact, high power density
power system is the perfect choice for space-critical
solutions.

LF_DPS1200B_2000B-48-n-ETS_en.doc / rev. 1.0 / 27.03.2006 / MHa www.deltaenergysystems.com


Back

Power System DPS 1200B_2000B-48-n ETS


Technical Specifications
General - 15 x MCB C60 for 300/600A
Efficiency 91% - 1 x C120 + 9 x C60 MCB
- 15 x MCB 5SY6 for 300/600A
Safety IEC/EN 60 950 - 4 x breaker 00
EMC EN 300 386-2 DPD 2 - 30 MCB, 2 x PLD 350 A
Cooling Fan cooled rectifiers - 20 x MCB + 6 x MCB separ.
DPR 1200B-48 (1200 W) or charge + PLD option
FR 48 V-2000 W-E (2000 W) - 12 x NH00
Protection IP 20 - 13 x (22 x 58)
- 6 x (22 x 58) + 4 x (10 x 38)
- 15 x (14 x 51)
Input Rect. 1200 W Rect. 2000 W - 6 x (22 x 58) + 8 x (14 x 51)
AC connection 1-3PH, 1 x 3PH (terminal), DPD 3 As DPD 2
3PH 2 x 3P m-switch, 1 x 3PH
4P m-switch, 1PH 2 x 2P m-
switch, 2 x 3PH, m-switch 3P + Battery connections
VDR+8x2PMCB - 9 x MCB27, 1 shunt [300 A]
Nominal voltage 3 x 230 VRMS (L-N) - 9 x MCB27, 3 shunts [300 A]
- 6 x 00, 1 shunt [300 A] or [600 A]
Range, full power 184 300 VRMS
- 3 x 02, 3 shunts [300 A] or [600 A]
Range, reduced power 88 184 VRMS - 2 x 02, 1 shunt, front LVD [300 A]
Frequency range 45 ... 66 Hz - 4 x 00, 1 shunt, front LVD [300 A]
Current nominal 3 x 23 ARMS 3 x 36 ARMS - 6 x MCB C120N 1SH, front LVD [300A]
(max. configuration) @ 14.4 kW @ 24 kW - 6 x MCB27, 1 shunt [300 A]
Current maximum 3 x 30 ARMS 3 x 48 ARMS - 3 x 02, 1 shunt [600 A]
(max. configuration) @ 14.4 kW @ 24 kW - 4 x MCB27, 1 shunt [300 A]
Inrush current < 43 APEAK < 60 APEAK
per phase per phase Mechanics
Line current Meets IEC 1000-3-2 Construction Sheet metal, frame cabinet
Harmonic distort. THD < 5% Cabinet standard ETSI
Mains terminal Terminal blocks or Height, overall 1800 / 2000 / 2200 mm
mains switch Width, body 600 mm
Main switch Option Depth, overall 600 mm
Transient OVP Option Weight, system Approx. 140 kg
Weight, rectifier 1.25 kg (DPR 1200B-48)
Output Rect. 1200 W Rect. 2000 W 4.4 kg (FR 48 V 2000 W E)
Voltage, nominal 53.5 VDC
Voltage range 42 ... 58 VDC Environment
Voltage error, static 250 mVDC Operating temperature -5 ... +45C
Overvoltage protection 59 1 V Relative humidity 95% max. non cond.
Ripple + spikes 200 mVp-p
Phophometric noise 1.0 mVRMS (weighted) Control and monitoring
Nominal current 270 ADC 448 ADC Power system controller PSC 3
(max. configuration) @ 14.4kW, @ 24 kW, PSC 1000
53.5V 53.5V
Current limit, maximum 335 ADC @ 558 ADC @
Options
(max. configuration) 14.4 kW, 43 V 24 kW, 43 V
- Blind plates for empty rectifier slots
Power, nominal 14.4 kW 24 kW - Transformer 20 kVA
Power, redundant 13.2 kW 22 kW - 19 inch 6U fixing
Power, reduced Min. 6 kW Min. 9.6 kW - Hoisting rings and fixing parts
@ 90 VAC @ 88 VAC
Note! The specifications are calculated according to
Load connections maximum amount of rectifiers. With rectifier DPR 1200B-48
There are three distribution units (DPD 1 3) in the it is 12 on 1 shelf and with FR 48 V 2000 W E it is 12 on
system. Partial load disconnections (PLD) are options. 2 shelves. The options for different connections have
- 3 x NH00+3 x MCB C120 + dependencies with each other, and therefore there are
DPD 1 some limitations to different combinations. This document is
4 x MCB C120
- 18 x MCB C60 for 300A subject to change due to technical progress.

Delta Energy Systems (Finland) Oy


Juvan teollisuuskatu 15
FIN-02921 Espoo, Finland
Phone: +358 9 849 660 Fax: +358 9 8496 6100 www.deltaenergysystems.com

Anda mungkin juga menyukai