MV network management

Easergy range
Panorama

2010
Easergy range Panorama
Easergy: a range of solutions for MV network management

Easergy range Remote network Remote network


dedicated supervisor control monitoring

L500 T200 P T200 I T200E Flite 116-SA/G200 Flair 200C

Easergy range dedicated Overhead switch Control unit for MV and MV/LV Communicating fault Communicating fault
remote control system control unit substations current detector for current detector for an
overhead lines MV substation
Capacity: Control of 1 or 2 Control of 1 to 16 Control of 4 Single-phase ammetric Three-phase, 2 channel
500 Easergy type devices switches switches switches detector fault current detector open
to all types of earthing
system

Main functions
b Network view with substation b Pole mounted b Wall-mounted b Ringmastermounted Flite 116: b Wall-mounted
alarm b Switch monitoring and control b Line installation b Phase-to-phase and
b Detailed substation view b Fault current detector b Phase-to-phase and phase-to-earth fault current
b Alarm logs, archives b Automation systems: sectionaliser, phase-to-earth fault current detection
b Direct access to substation power supply source changeover switch detection b U, I, P, Q, S, energy and
view via a list b Measurements: I, U, b Measurements: I, U b I and U presence power
b Automatic sorting of alarms P, Q, S, energy and measurements factor measurements cos
and archives by substation power factor cos j b Communication b Management of 3 digital
b Online help management with G200 outputs and 6 digital inputs
b Concentration of Modbus communication devices b Powered by lithium battery b 220 Vac supply backed-
b Data and measurements archives G200: up by Ni-CD battery
b Back-up power supply for control unit, b Pole-mounted b Concentration of Modbus
switch and transmission equipment b Flite 116 concentrator communication devices
b Processing and archiving b Data and measurements
b Free I/O: 3 digital outputs archives
and 6digital inputs
b 220 Vac, solar or 12 Vdc
supply

Communication
b Integrated communication b 1 to 2 serial communication ports b 915 MHz short range radio b 1 communication port
front-end b 1 Ethernet port communication b 1 Ethernet port (option)
b Permanent and non- b Communication port operation b 1 SCADA communication b Transmission interface:
permanent communications management port PSTN, Radio, GSM, GPRS,
management: b Transmission interface: PSTN, radio, GSM, GPRS, Ethernet, b Transmission interface: Ethernet, RS232, RS485
v telephone/GSM dedicated line, RS232, RS485 radio, GSM, GPRS, CDMA
v radio
v direct public and dedicated
private line
b Periodic call management

Communication protocol
b Modbus b IEC 870-5-101 and IEC 870-5-104 b IEC 870-5-101 b IEC 870-5-101
b Serial DNP3 and TCP/IP b Serial DNP3 and TCP/IP b DNP3
b Serial Modbus and TCP/IP b Modbus b Modbus
b Other proprietary protocols

Data configuration
b Professional communications b
Embedded web server b Local and remote b Local or remote
and database editor b
Local and remote configuration configuration with Easergy configuration
b Data creation via dialogue L500 b Embedded web server
boxes

Accessories
b Radio, PSTN, DL and b Simulation tools and tests b Installation tool b Open phase and zero
fibre optic modems sequence sensors
b Open phase
and zero
sequence sensors
Local fault
indication

Flite 110-SA Flite 210, 230 Flite 312, 315, 332, Flair 21D, 22D, 23DV Flair 219, 279 Flair 310, 370
335, 382
Fault current detectors for an overhead network Fault current detectors for MV substations

Single-phase ammetric Three-phase ammetric Three-phase directional DIN format three-phase Three-phase ammetric Three-phase directional
detector detectors detectors ammetric detectors detectors detectors

Main functions
b Line installation b Pole-mounted b Pole-mounted b Incorporated in the b Wall-mounted b Wall-mounted
switchgear
b Phase-to-phase and b Phase-to-phase and b Phase-to-phase and b Phase-to-phase and b
Phase-to-phase and b Phase-to-phase and
phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault phase-to-earth fault
current detection current detection current detection current detection current detection current detection
b Indication of transient b Indication of transient b Transient and/or b Measurements: b Indication of transient
and permanent faults and permanent faults permanent fault indicator v ammeter and permanent faults
b Fault counter v maximeter

b Powered by lithium b Powered by lithium b Powered by lithium b Self-powered by b Power supply: b


Power supply:
battery battery battery, solar panels or current sensors v Flair 279: 220 Vac 230 Vac backed up by
12 Vdc depending on (battery-backed) battery or external
model v Flair 219: battery depending on model

Communication
b
Option: signalling b
Signalling contacts b
Signalling contact for b
Signalling contact b
Signalling contact
contact for RTU for RTU RTU for RTU for RTU

Data configuration
b By micro-switches b By micro-switches b Configurable via b By micro-switches b By micro-switches b Configurable via
display unit or button and display unit display unit

Accessories
b Installation tool b Open phase and zero b Open phase and zero b Open phase and zero
sequence sensors sequence sensors sequence sensors
b Unit for wall-mounting
What are the expected advantages
of MV network management?
b Develop customer satisfaction
and services
b Increase economic performance
b Control investment (past and future)

Reduce outage time


b Optimized intervention as a result of reliable information from fault current
detectors, locally and from a distance.
b In the event of a fault, the control units can be used to restore the supply
to the healthy parts of the network:
v by the operator from the remote control center: 50% of the network supply
can be restored within a few minutes
v by the integrated automated devices: the faulty sections of the reset cycle
can be isolated.

Improve the quality of distributed energy


b Accurate information about permanent and transient faults allows corrective
and preventive maintenance to be carried out to reduce fault repeatability.
b The quality of the distributed energy can be monitored by means of relevant
recorded and transmitted measurements:
v measurement of load currents and real-time indication of variations
v measurement of voltages with indication and storage of voltage dips and jumps
v measurement of the power factor.

Reduce operating costs


b Accurate fault information considerably reduces fault detection time:
v on-site intervention times are greatly reduced through the use of communicating
devices
v accurate fault information simplifies troubleshooting operations and tasks.
b Preventive maintenance on the MV network reduces the number of call-outs
during duty hours.

Fast return on investment


b The modularity and integrability of the Easergy products range significantly
reduce installation and commissioning costs.
b The integral modularity of the Easergy products range allows you to invest
exactly what is required and to benefit from an immediate return on investment.
You can then add extra equipment when your budget allows.
b Investing in the control station can be costly and take time to implement.

ART.832397 Schneider Electric Industries SAS - All rights reserved


Remote control of your networks can be achieved in stages using simple systems
that can be implemented within a few months. This also allows the improvement
in quality of service and the technical options to be assessed:
v adapting stations to remote control: power-operated MV cubicles, control unit
or communicating detector, transmission equipment
v the comprehensive real-time network control functions and price-quality ratio of
the Easergy L500 SCADA make it an exceptional tool for the following applications:
- remote control of small networks
- system dedicated to controlling networks complementary to the DMS system
- temporary system until a DMS is installed
- system maintenance
- trial runs.

Schneider Electric As standards, specifications and designs change from time to time, please ask for confirmation
35 Rue Joseph Monier of the information given in this publication.
CS 30323
92506 Rueil Malmaison Cedex This document has been printed
Tel : +33 (0)1 41 29 70 00 on ecological paper
Fax : +33 (0)1 41 29 71 00
Publishing: Schneider Electric Industries SAS
www.schneider-electric.com Design: Schneider Electric Industries SAS
Printing: Imprimerie du Pont de Claix/JPF - Made in France

AMTED107018EN 01-2010

Anda mungkin juga menyukai