Fluid Data
Flow Rate 3000 gpm 6.684 ft^3/sec
Fluid density 62.31 lb/ft^3 Water 68F
Absolute Viscosity 0.000672 lbm/ft.s Water 68F
Wire Screen head loss in K 0.32 Typical circular metal wire screen K factor
Ratio Aopen/Atotal 0.05
Area (annulus) 0.5421450806 ft^2 K 363
Wetted Perimeter of annulus 2.8850292535 ft
Hydraulic Diameter of Annulus 0.7516666667 ft
Hydraulic Radius of Annulus 0.1879166667 ft Serghide Friction Factor Equation
Velocity (annulus) 12.328803192 ft/sec A 8.336268
B 8.212644
Reynolds number ( annulus) 859279.97232 C 8.21666
Friction factor 0.0148123064 Serghide Equation f 0.014812