Motor Control&Protection
The Righ
t Choice!
Applicable. Available. Accountable.
Product list

HDC6 AC Contactor 1-2

Order Information 3-4

Main Technical Parameter 5-6

Function and Features 7-17


Directional Contactor
Option for Star Delta Starter
Accessories
Overall Dimension of Installation
HDR6 Thermal Overload Relay

Order Information 18-19

Function and Features 20-27

Introduction for Functions


Technical Parameter
Tripping Characteristics and Wiring Diagram
Installation Methods
Overall Dimension of Installation

HDZ6 Contactor Relay

Order Information 28

Function and Features 29-30

Main Technical Parameter


Overall Dimension of Installation
H

HFD6-11,HFD6-20,HFD6-02
HFD6-22,HFD6-13,HFD6-31,HFD6-40,HFD6-04

HFC6-11,HFC6-20,HFC6-02

HFT6-20,HFT6-22,HFT6-24
HFT6-30,HFT6-32,HFT6-34

HFR6-32
HFR6-95

HX6+AF+Us+frequency
HX632N7

H H H

H H

1
HFD6-11,HFD6-20,HFD6-02
HFD6-22,HFD6-13,HFD6-31,HFD6-40,HFD6-04

HFT6-20,HFT6-22,HFT6-24
HFT6-30,HFT6-32,HFT6-34

HX6-115-630(Voltage AC:230V,400V for Option)

HMC6-115~630

H H

2
H

H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H

3
H

H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H
H

4
H

H H H H H H H H H H

5
H H H H H H H H H

6
H

H
H

H
H

H
H

H
H

H
H

7
H

H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H
H H H H

8
H

9
H

HFR6 Mechanical Interlock Module

HFD6 Top of Auxiliary Contact

HFC6 Side Auxiliary Contact


HFD6 Top of Auxiliary Contact

HDR6 Thermal Overload Relay

HFT6 Air Delayed Head

HX6 Coil

HFD6 Top of Auxiliary Contact

HFD6 Top of Auxiliary Contact

HFT6 Air Delayed Head


(Making time-delay)

HFT6 Air Delayed Head


H (Breaking time-delay)

10
H

Auxiliary Contact
Installation
Installation Composition Composition
Pole Pole Contact Contact Point LayoutReference Reference
Position
Position NO NC NO NC Point Layout
0 2 61 FD6 02
51 61 53 61 53 63
0 2 2 HFD6 02
51 53 61 53 63
2
1 1 1 1 HFD6 11 FD6 11
2 0 62 FD6 20
52 62 54 62 54 64
2 0 HFD6 20
52 54 62 54 64

Top 2NC 1NO1NC2NC 1NO1NC


2NO 2NO
Top
4 0 4 4 0 451 61 71 81 53 61
51 61 71 81 53 61 71 81 53 61 71 83
71 81 53
HFD6 04
61 71 83
FD6 04

1 3 1 3 HFD6 13 FD6 13

2 2 2 252 62 72 82 54 62 72
52 62 72 82 54 62 72 82 54 62 72 84
4NC 1NO3NC
82
HFD6
54
22
2NO2NC
62 72 84
FD6 22
4NC 1NO3NC 2NO2NC

3 1 3 53 161 73 83
53
53
61
63
73
73
83
83
53
HFD6
6373
31
83 FD6 31

4 0 4 0 HFD6 40 FD6 40
54 62 74 84 54 64 74 84
54 62 74 84 54 64 74 84
3NO1NC 4NO
3NO1NC 4NO

0 2 0 11
(32)
2(42)
21 23
(44)
11
(32)13
(34)
2123
(42)
(44)
23 13
(44) 11 (34)
(32)
23
HFD6
(44)
02
(32)
11
FD6 02
Side
Side 2 2 1 1 FD6 11
1 1 12 22 24 24 14
HFD6
24 11
12
12 22 24 (31)14 (41) (43) 12 (43) (43) (31)
(43) (31)
2 02NC FD6 20
(31) (41) (43) (43)
2 0 1NO1NC
2NC
2NO
1NO1NC HFD6
2NO 20
H

FT6 Air
HFT6 AirDelayed
DelayedContact
Contact
Installation
Installation Reference
Position Delay Type Delay TypeDiagram
Wiring Wiring Diagram Delay Range
Delay Range Reference
Position
55 67

0.1-3s 0.1-3s HFT6 20FT6 20


55 67

Making Making
time-delay time-delay 0.1-30s 0.1-30sHFT6 22FT6 22
56 68 10-180s 10-180sHFT6 24FT6 24
56 68

Top 65 57
Top 0.1-3s 0.1-3s HFT6 30FT6 30
65 57

Breaking Breaking
time-delay time-delay 0.1-30s 0.1-30sHFT6 32FT6 32
66 58
66 58 10-180s10-180sHFT6 34FT6 34

al

11
H

HDC6-9~32 HFR6 32 H
HDC6-40~95 HFR6 95 H
HDC6-115~150 HFR6 FF H
HDC6-185~225 HFR6 GGH
HDC6-265~330 HFR6 HH H
HDC6-400~500 HFR6 KK H
HDC6-630 HFR6 LL H

HDC6-115 HDC6-115 HFR6 FF V


or HDC6-150 HFR6 FF V
HDC6-150 HDC6-185 HFR6 FG V
HDC6-225 HFR6 FG V
HDC6-265 HFR6 FH V
HDC6-330 HFR6 FH V
HDC6-400 HFR6 FH V
HDC6-500 HFR6 FH V
HDC6-630 HFR6 FL V
HDC6-185 HDC6-185 HFR6 GG V
or HDC6-225 HFR6 GG V
HDC6-225 HDC6-265 HFR6 GK V
HDC6-330 HFR6 GK V
HDC6-400 HFR6 GK V
HDC6-500 HFR6 GK V
HDC6-630 HFR6 GL V
HDC6-265 HDC6-265 HFR6 HK V
or HDC6-330 HFR6 HK V
HDC6-330 HDC6-400 HFR6 HK V
HDC6-500 HFR6 HK V
HDC6-630 HFR6 HL V
HDC6-400 HDC6-400 HFR6 HK V
HDC6-500 HFR6 HK V
HDC6-630 HFR6 HL V
HDC6-500 HDC6-500 HFR6 HK V
HDC6-630 HFR6 HL V
HDC6-630 HDC6-630 HFR6 LL V

12
H

HX6 Coil

HX6 150 M
HX6 150 Q
HX6 225 M
HX6 225 Q
HX6 330 M
HX6 330 Q
HX6 400 M
HX6 400 Q
HX6 500 M
HX6 500 Q
HX6 630 M
HX6 630 Q

HMC6 Main Contact

HMC6 115
HMC6 150
HMC6 185
HMC6 225
HMC6 265
HMC6 330
HMC6 400
HMC6 500
HMC6 630

13
H

HDC6-9~32

HDC6

HDC6-9~32N

HDC6-

14
H

15
H

HDC6-115
HDC6-150
HDC6-185
HDC6-225
HDC6-265
HDC6-330

HDC6-400
HDC6-500

16
H

HDC6-630

HDC6-630

HDC6 HDC6

HDC6 HDC6

17
H

Product Type Frame Current Setting Current Installation Type


HDR6 18 P15

18:18A P150.1-0.15 Default:None


Coil Rapid Wiring Terminal F:Independent installation
630:630A 630:460-630A
P means
Tripping decimal point
Indication,
Test and Manual Reset Button
Fuse used for Matching
Range for Setting
with Relay Matched Contactor Reference
Current
Reset Setting Knob aM gG
0.10-0.15A 0.25 2 HDC6-09~18 HDR6 18 P15
TEST
0.12-0.18A 0.25 2 HDC6-09~18 HDR6 18 P18
TRIP RESET
0.18-0.25A 0.5 2 HDC6-09~18 HDR6 18 P25
STOP
18
0.25-0.36A 1 2 HDC6-09~18 HDR6 18 P36
14

A H
0.35-0.50A 16 1 2 HDC6-09~18 HDR6 18 P5
0.50-0.70A 1 2 HDC6-09~18 HDR6 18 P7
0.63-0.90A 2 4 HDC6-09~18 HDR6 18 P9
Stop Button Current Setting Button
0.90-1.20A 2 4 HDC6-09~18 HDR6 18 1P2
96 NC 95 98 N0 97
1.20-1.80A 4 6 HDC6-09~18 HDR6 18 1P8
1.80-2.50A 4 6 HDC6-09~18 HDR6 18 2P5
2.50-3.60A 6 10 HDC6-09~18 HDR6 18 3P6
3.50-4.80A 8 16 HDC6-09~18 HDR6 18 4P8
2T1 4T24.50-6.30A
6T3 8 16 HDC6-09~18 HDR6 18 6P3
5-7A 12 20 HDC6-09~18 HDR6 18 7
6.3-9A 12 20 HDC6-09~18 HDR6 18 9
9-12A 16 25 HDC6-09~18 HDR6 18 12
11-15A 20 35 HDC6-09~18 HDR6 18 15
1.Reset Setting Knob 2.Tripping Indicator, Test and Manual Reset Button
14-18A 20 35 HDC6-09~18 HDR6 18 18
Manual Reset for Arrow 6.3-9A 12 After the 20
operation of tripping indication and HDR6 32 9
HDC6-25~32
Pointing to H thermal overload relay, yellow button to Trip
9-12ATEST 16 25 HDC6-25~32 HDR6 32 12
Automatic Reset for Arrow position means tripping;
Pointing to A 12-18A 20 After the 35 HDC6-25~32
operation of manual reset, the reset HDR6
is 32 18
TRIP RESET
18-25A 25 realized to 50put yellow button
HDC6-25~32
back to Reset HDR6 32 25
23-32A 40 position; 63 HDC6-25~32 HDR6 32 32
18-25A 25 Implement
50the test to simulate the tripping (use
HDC6-40~95 NO 95 25
HDR6
and NC Contact to operate) and check the control
23-32A 40 63 HDC6-40~95 HDR6 95 32
circuit. When carrying out the test under manual
30-40A 40 100 HDC6-40~95 HDR6 95 40
reset state, put back to Reset position after
37-50A 63 100 HDC6-40~95 HDR6 95 50
reaching Trip. Automatically rebound to Reset
48-65A 63 100 to TripHDC6-40~95
after switching for automatic reset. HDR6 95 65
55-70A 80 125 HDC6-40~95 HDR6 95 70
3.Stop Button 4.Current
63-80A Setting80
Button 125 HDC6-40~95 HDR6 95 80
Make NC Contact operate, but 80-95A 100 160 HDC6-40~95 HDR6 95 95
Set the value of setting current for rated
not influence NO contact. After
STOP electromotor.
pressing Stop Button, cut control
18

circuit off and the electromotor Base


14

stops working. 16
Adaptive Thermal Relay Type Reference
HDR6-18 HDR6 18 J
HDR6-32 HDR6 32 J
HDR6-95 HDR6 95 J

18
H

Fuse used for Matching


Range for Setting
with Relay Matched Contactor Reference
Current
aM gG
48-65 80 100 HDC6-115~185 HDR6 185 65

55-70 80 100 HDC6-115~185 HDR6 185 70

63-80 80 100 HDC6-115~185 HDR6 185 80

75-95 100 125 HDC6-115~185 HDR6 185 95

90-115 125 200 HDC6-115~185 HDR6 185 115

105-135 160 200 HDC6-115~185 HDR6 185 135

120-150 160 200 HDC6-115~185 HDR6 185 150

130-160 160 250 HDC6-115~185 HDR6 185 160

150-185 200 250 HDC6-115~185 HDR6 185 185

145-200 200 400 HDC6-225~630 HDR6 630 200F

180-250 250 400 HDC6-225~630 HDR6 630 250F

230-320 355 500 HDC6-225~630 HDR6 630 320F

290-400 400 630 HDC6-225~630 HDR6 630 400F

350-480 500 800 HDC6-225~630 HDR6 630 480F

460-630 630 800 HDC6-225~630 HDR6 630 630F

19
H
Introduction for Functions

Coil Rapid Wiring Terminal

Tripping Indication,
Test and Manual Reset Button

Reset Setting Knob

TEST
TRIP RESET
STOP

18
14
A H 16

Stop Button Current Setting Button

96 NC 95 98 N0 97

2T1 4T2 6T3

1.Reset Setting Knob 2.Tripping Indicator, Test and Manual Reset Button
Manual Reset for Arrow After the operation of tripping indication and
Pointing to H thermal overload relay, yellow button to Trip
TEST
Automatic Reset for Arrow position means tripping;
Pointing to A TRIP RESET After the operation of manual reset, the reset is
realized to put yellow button back to Reset
position;
Implement the test to simulate the tripping (use NO
and NC Contact to operate) and check the control
circuit. When carrying out the test under manual
reset state, put back to Reset position after
reaching Trip. Automatically rebound to Reset
after switching to Trip for automatic reset.

3.Stop Button 4.Current Setting Button


Make NC Contact operate, but
Set the value of setting current for rated
not influence NO contact. After
STOP electromotor.
pressing Stop Button, cut control
18

circuit off and the electromotor


14

stops working. 16

20
&'57KHUPDO2YHUORDG5HOD\
HDR6 Thermal Overload Relay
7HFKQLFDO3DUDPHWHU
Technical Parameter

Main Technical Parameter


0DLQ7HFKQLFDO3DUDPHWHU
Temperature Compensation
7HPSHUDWXUH&RPSHQVDWLRQ -10C~+55
-10 C~+55CC
Trip class
7ULSFODVV HDR6-18,32,630/F:10A
CDR6-18,32,630/F: 10A
HDR6-95,185:10
CDR6-95,185: 10
HDR6-18
&'5 0.1~18A
a$
HDR6-32
&'5 6.3~32A
a$
Frame Current
)UDPH&XUUHQW HDR6-95
&'5 18~95A
a$

HDR6-185
&'5 48~185A
a$
HDR6-630/F
&'5) 145~630A
a$
Rates impulse withstand voltage (Uimp)
5DWHVLPSXOVHZLWKVWDQGYROWDJH 8LPS 6kV
6kV

2YHUORDG3URWHFWLRQ YES
YES
Protection Function
Phase Failure Protection
3KDVH)DLOXUH3URWHFWLRQ YES
YES

Manual and Automatic Reset


0DQXDODQG$XWRPDWLF5HVHW YES
YES

Tripping Indication
7ULSSLQJ,QGLFDWLRQ YES
YES

Stop Button
6WRS%XWWRQ YES
YES

Test Button
7HVW%XWWRQ YES
YES

Installation Method
,QVWDOODWLRQ0HWKRG Assembly/ /Independent:
Assembly Independent:CDR6-18~185
CDR6-18~185

Independent:CDR6-630/F
Independent: CDR6-630/F
Auxiliary Circuit
$X[LOLDU\&LUFXLW
Rated Thermal Current
5DWHG7KHUPDO&XUUHQW 6A
$

Contact Type
&RQWDFW7\SH 1NO+1NC
121&
Rated Insulating Voltage
5DWHG,QVXODWLQJ9ROWDJH 690V
9
AC-15 220V/240V
$&99 1.64A
$
Control Capacity
&RQWURO&DSDFLW\ AC-15 380V/415V
$&99 0.95A
$
DC-13 220V/240V
'&99 0.23A
$

Section of Connecting Conduction


6HFWLRQRI&RQQHFWLQJ&RQGXFWLRQ 1mm 2
PP
Wiring Ability
:LULQJ$ELOLW\
Fastened Torque
)DVWHQHG7RUTXH 1.2NPm
1

Main Circuit Wiring Ability


0DLQ&LUFXLW:LULQJ$ELOLW\

g g
















h

h

21


H
Tripping Characteristics and Wiring Diagram

Tripping Characteristics

Mulriple of Setting Tripping Time Ambient


No. Initial Condition
Current Trip class 10A Trip class 10 Temperature
Tripping Characteristics for Current Balance
1 1.05 Non-tripping within 2h Non-tripping within 2h Without previous load +20C

2 1.2 Tripping within 2h Tripping within 2h After No.1 Test

3 1.5 2min 4min After No.1 Test

4 7.2 2sTp10s 4sTp10s Without previous load +20C


Tripping Characteristics for Current Imbalance

Any 2-Phase, 3rd Phase

1 1.0 0.9 Non-tripping within 2h Non-tripping within 2h Without previous load +20C

2 1.15 0 Tripping within 2h Tripping within 2h After No.1 Test

Tripping Characteristics Wiring Diagram

Average Value (Environmental Temperature: 20C) ( )

80
50
30
20
FU
(Min) SB1
10
8
5 1 3 5
A1
3
KM
4
Operation time

2 2 6
A2 SB2
Without previous load
60
40 2-Phase (Phase Failure)
30
Without previous load
20 1 3 5
95 97
10 FR
8
6 96 98
(s) 4 2 4 6
3
With previous load
2
U V W

0.8
0.6 M
0.4
0.3
0.8 1 1.5 2 3 4 5 6 7 8 9 10 15

Multiple of Setting Current Xle(A)

22
H
Installation Methods

HDR6-9~95
Assembly Installation

1L1 3L2 5L3 12NO 21NC

A1

A2

2T1 4T2 6T3 14NO 22NC

A2 95 STOP 97 TRIP RESET 1L1 3L2 5L3

96 98
2T1 4T2 5T3

This wire is the coil rapid wiring terminal,


which can be used as the assembly with
the contactor. When two are completely
connected, it is to ensure that the screw
in A2 contact point of the contactor coil
is tightened.

1L1 3L2 5L3 12NO 21NC

A1

A2

2T1 4T2 6T3 14NO 22NC

STOP 97 TRIP RESET 1L1 3L2 5L3


95
If this wiring terminal is not used,
it can be cut short and then insulating
tape can be used in conductive parts.

96 98
2T1 4T2 5T3

23
H
Installation Methods

HDR6-9~95
Independent Installation

HDR6-185
Assembly Installation Independent Installation

Note: It also can be fixed by screws.

Fasten the screws.

HDR6-630/F
It only can be fixed by 75mm railway or screws.

24
H
Overall Dimension of Installation

HDR6-18 Assembly Installation HDR6-18 Independent Installation

77max

86max

74
35
127

35
73max

46max

46.2 10.6 10.6

69max 46
A

Assembly Installation for HDR6-18 and HDC6-09, 12 , 18


HDC6-09 HDC6-12 HDC6-18
A 84 84 89

HDR6-32 Assembly Installation HDR6-32 Independent Installation


57
103max

74
86max
35
137

44
78max

57max

65.7
13.6 13.6
95max
55
101max

25
H
Overall Dimension of Installation

HDR6-95 Assembly Installation HDR6-95 Independent Installation


85max
51

91max
35

74.1
182
118.5max 51
85max

78max

62.1
21 21
111max
A 72

Assembly Installation for HDR6-95 and HDC6-40~95


HDC6-40 HDC6-50 HDC6-65 HDC6-80 HDC6-95
A 118.5 118.5 118.5 127.5 127.5

26
H
Overall Dimension of Installation

HDR6-185 Assembly Installation HDR6-185 Independent Installation


B
132max 105max
40 40
77.9 37 37

82.5
103
35.5
77.9

A
103max

76 2x 7
37 37
76 37
132max
37
C
105max

Assembly Installation for HDR6-185 and HDC6-115~185


HDC6-115 HDC6-150 HDC6-185
A 248 253 257
B 167 167 171
C 172 172 183

HDR6-630/F Independent Installation

181max
150max
108
4x 7
70
2
171max
144

130
75

50

27
H

HDZ6

HDZ6 41
HDZ6 32

28
H

H HDZ6-32

HFC6 Side Auxiliary Contact

HFD6 Top of Auxiliary Contact

HFC6 Side Auxiliary Contact

HFD6 Top of Auxiliary Contact

HFT6 Air Delayed Head

Note: the accessories of HDZ6 are in common use with HDC6,


and please refer to P11 for more information about the accessories.

29
H

HDZ6-41 HDZ6-32

30
A Company to Serve Y
ve
A Company to Serve

E
e You Where You Are
e You Where You Are

E-mail Address:info.OBD@delixi-electric.com
E-mail Address:info.OBD@delixi-electric.com
E-mail Address:Contact@himel-electric.com

Anda mungkin juga menyukai