Anda di halaman 1dari 62

COMMUNICATION AND DISPLAY TECHNOLOGIES

VARIABLE MESSAGE SIGN FOR


MOTORIST INFORMATION

INSTALLATION, USE AND MAINTENANCE


MANUAL

VerbaTRAFFIC FCxS500

aesys S.p.A. sede legale: Via Artigiani, 41 - 24060 BRUSAPORTO (BG) Italy
sede operativa: Via Pastrengo, 7/c - 24068 SERIATE (BG) Italy
Tel. +39 035 29240 Fax +39 035 680030 e-mail: info@aesys.it CAPITALE SOCIALE 1.000.000 I.V.
C.F. - PART. IVA - REG. IMPRESE TRIBUNALE BERGAMO N 02052370166 - ATTESTAZIONE S.O.A. N 15957/10/00

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.2

COMMUNICATION AND DISPLAY TECHNOLOGIES

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.3

COMMUNICATION AND DISPLAY TECHNOLOGIES

1) Introduction.................................................................................................6

2) Generalities .................................................................................................6

3) Electric and mechanical panel characteristics ........................................7


3.1) General charactistics ................................................................................................. 7
3.2) Mechanical features/installation ................................................................................. 9
3.3) Electric characteristics / connections ....................................................................... 10

4) Function ....................................................................................................12
4.1) Communication protocol .......................................................................................... 12

5) Reliability and maintenance ....................................................................13


5.1) Preventive maintenance .......................................................................................... 13
5.2) Corrective maintenance ........................................................................................... 13
5.3) Main spare parts list................................................................................................. 14

5.3.1) FCxS500 INOX.................................................................................................. 14


5.3.2) FCxS500 with rear PG connectors .................................................................... 15
5.3.3) FCxS500 with Buccaneer connectors ............................................................... 16
5.3.4) FCxS500 with ILME connectors ........................................................................ 17

5.4) Troubleshooting/diagnostics .................................................................................... 18

6) Certifications and testing ........................................................................19

7) Labeling.....................................................................................................19

ANNEXES:

TEST REPORT

OVERALL DIMENSIONS
(herewith different versions, please be sure to check the right model) :
FCxS500 with rear PG connectors
FCxS500 with Buccaneer connectors
FCxS500 with ILME connectors

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.4

COMMUNICATION AND DISPLAY TECHNOLOGIES

OVERALL DIMENSIONS OF POSSIBLE SUPPORTS


Wall support
Fixed supports
Support from top (ILME connectors)
Support from top (no ILME connectors)
Ceiling support (L=860mm)
Ceiling support (L=1700mm)
Ceiling support (L=720mm)

WIRING DIAGRAM
(herewith different versions, please be sure to check the right model) :
FCxS500 with rear PG connectors, Serial Line and Ethernet version
FCxS500 with rear PG connectors, Relays and Ethernet version (2S)
FCxS500 with Buccaneer connectors, Serial Line version
FCxS500 with Buccaneer connectors, Ethernet version
FCxS500 with ILME connectors, Relays and Ethernet version (2S)
FCxS500 with ILME connectors, Relays and Ethernet version (4S)
FCxS500 with ILME connectors, Serial Line and Ethernet version
FCxS500 with ILME connectors, Optical Fiber version

LED BOARDS LAYOUT TABLE

DIP SWITCH SETTING TABLE FOR P.C.B. 0429 CPU

DIP SWITCH SETTING TABLE FOR P.C.B. 0216 EXPANSION

SERIAL TERMINATION P.C.B. 0930 TABLE

CONTROLLER BOARD P.C.B. 0504 TABLE

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.5

COMMUNICATION AND DISPLAY TECHNOLOGIES

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.6

COMMUNICATION AND DISPLAY TECHNOLOGIES

1) Introduction

The following document is aimed at describing the building elements, power


connections, the use and maintenance the variable message sign (VMS), model
VerbaTRAFFIC FCxS500.

2) Generalities

The signs are employed in motorway transit areas in order to inform motorists about
any conditions of traffic flow related problems (queues, accidents, road-work, etc..).
The above mentioned environment is characterized by the occasional presence of
dark oily particles due to vehicle emissions (truck and full trailer exhaust); more so,
during the winter by the presence of salt transported and pulverized by HGVs in transit
and the site is subject to low temperatures and high humidity levels.
The VMS are subject to strong wind gusts featuring pressures and counter pressures
generated by vehicle passage, inflicting both solicitations and vibrations to the sign
structures.

On the highways panels are mounted on gantries placed at an adequate height from
the ground, on the street centre line. At the base of these gantries all the accessory
devices are located. If the gantry is placed in a tunnel, it is necessary to foresee
specific supports that enable the fixing to the tunnel ceiling, or in case the panels
should be mounted at the tunnel entrance, to the entrance vault of the tunnel.

Thanks to a specific communication system, the panel is in connection to an operating


central unit, which sends the messages concerning the viability status and receives
the data regarding the function status of the panel.

In the dry contacts version, a status of executed visualization of the image is sent
back.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.7

COMMUNICATION AND DISPLAY TECHNOLOGIES

3) Electric and mechanical panel characteristics

3.1) General characteristics

The VerbaTRAFFIC FCxS500 is a graphic polychrome discontinuous VMS,


with 2 (FC2S500) or 4 (FC4S500) states, that features the following
characteristics:

Led dot matrix with cross and arrows in red, green and yellow colour (the latter
one only for 4S).
Led density around 2900 led / m^2
Each symbol (state) is made of chains of leds:
- Bluish green downward arrow, dominant wavelength 500nm
- Red cross, dominant wavelength 610nm
- Yellow leftward oblique arrow, dominant wavelength 592nm (4S only)
- Yellow rightward oblique arrow, dominant wavelength 592nm (4S only)
Displayable colours:
- Bluish green
- Red
- Yellow (4S only)
- Black (neutral background)
The chromatic coordinates are in compliance to Class C2 of Regulation EN
12966 for green colour (bluish green), to Class C1 for red colour , to Class
C1,C2 for yellow.
Led boards (p.c.b. 0607) mounted differently according to the position.
Active area, per matrix: H=500 mm x L=500 mm.
Daytime active luminance of single colours, in Cd/m2 in accordance with class
L3 (The values in brackets are those foreseen by Regulation EN 12966):
- Red 8200 (3100)
- Green 9100 (3720)
- Yellow 12000 (7440)
Luminance during nighttimes conditions (luminous output less than 4 Lux):
adjustable to a minimum of 75 Cd/m2
Readability Angle: in compliance to class B4 of the Regulation EN 12966.
- Horizontal readability angle: 20 (+10 e 10).
- Vertical readability angle: 10 (+0 e 10).
Luminance uniform output: < 3 in compliance to par. 7.6 of Regulation EN
12966.
Contrast : in compliance to class R3 of Regulation EN 12966.
- Red > 4,2
- Green >5
- Yellow > 10
Led pilot system: static with power flow regulation
Led technology: red and yellow AlInGaP; green and blue InGaN

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.8

COMMUNICATION AND DISPLAY TECHNOLOGIES

Adjustable luminosity by remote control (on Ethernet/Serial line) with the


possibility of forcing to a level (adjustable at will) ranging from the minimum
(level 1) to the maximum (level 255) or automatically in function of the
surrounding brightness detected by two sensors (one frontal and one rear) and
by the remotely set configuration.
Integrated on-line diagnostics for the mapping of damaged led (not available
on dry contacts version).
N1 front hinged hatch for electrical access and maintenance, with key lock and
compression gas springs for anti-wind blocking system. The hatch may be
opened at 90 angle with a total dimensions (panel width + hatch opening) of
ca. 760 mm.
Casing dimensions: H = 650 x L = 650 x P = 150 mm.
Power supply: 230 Vac +10% - 15%.
Frequency: 50 Hz +/- 2 Hz.
Consumption: max 100 VA.
Immunity to voltage micro-interruptions (<200ms).
Degree of protection: IP 65 in compliance to the EN60529.
Weight: about 25 Kg.
Operating temperature range: -25C +60C with 95% maximum relative non-
condensing humidity.
The panel is composed of an aluminium alloy casing, 20/10 thickness, or INOX
steel, preformed and assembled by means of seam welding. The exterior
structure is coated with primer and outdoor epoxy mat black paint, with
preventive metal plate pickling. The frontal part (screen) is composed of an
aluminium plate, 15/10 thickness, or INOX steel, and is opaque black with holes
in correspondence of each single led, internally protected against water and
dust infiltrations by UV stabilized and anti-shattering polycarbonate screen of 2
mm thickness.
The front screen achieves a high waterproof and dustproof protection by a
closed-cell rectangular profile neoprene sealing placed along the entire
perimeter.
The hatch achieves a high waterproof and dustproof protection by a closed-cell
rectangular neoprene sealing placed along the entire perimeter; the particular
door frame shape impairs water infiltrations in the signs
The n2 locks are compression type locks, with die-cast zinc structure, seat
and springs in stainless steel, socket in Al-6262-T9, dog in chromate
galvanized steel, standard Southco socket key in nichel plated steel, mod.
E3-55-75.
Fixation to the load bearing structure (gantry or other support) by 4 full
stainless steel cylinder bolts, M8 threading x 12mm.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.9

COMMUNICATION AND DISPLAY TECHNOLOGIES

3.2) Mechanical features/installation

The panels were designed while taking into account installation modalities,
environmental conditions and ease of maintenance.

Environmental conditions: given the constant presence of aggressive agents such as


saline mists and petrol exhaust particles, the materials employed for the casing,
screen and external bolts and screws have been selected with characteristics of
inoxidizablity (anti-rust), inalterability (with particular regard for painting, realized with
epoxy polyester paints) and mechanical resistance.

Casing: composed of an aluminium sheet, 20/10 thickness, or INOX steel, shaped and
seam welded, avoiding sharp edges and pointy corners.

Screen: The front of the panel is made of an aluminium sheet, 15/10 thickness, or
INOX steel, that is painted opaque black, with holes in correspondence of each single
led, internally protected against water and dust infiltrations by a UV stabilized and anti-
shattering polycarbonate screen. The polycarbonate screen is sealed to the front
metal sheet with polyurethane glue and perforated counter plates onto which the led
circuit boards are fastened by means of screws.

Internal area: The electronic led boards are mounted on the internal horizontal
counter-plates. The plates have a hole in correspondence of each pixel that allows led
visibility from all directions; the counter-plates are employed in order to avoid direct
beaming on the electronic boards and improve heat dissipation.
The led boards are mounted via M3 male connectors (solidly connected to the plates),
nylon washers and self-locking M3 nuts; each board has more connecting points.

The control signal amplification/distribution boards for led switch-on and diagnostics
are mounted on the internal sides by support plates that also carry the power-line
ducts.
Power supply units (n1 with 150W-12VDC + n1 with 60W-5VDC + n1 with 25W-
24VDC) are fixed to a counter plate mounted on side part of the casing, easily
accessible if the maintenance door is open. The main power units (230Vac) are
gathered in electric ducts, as are the secondary units (5 - 12 - 24 VDC) .

Component dislocation has been optimized in order to ease VMS maintenance: easy
access and led board removal, replacement in case of breakdown with standard tools
(hex socket wrench).

Hatches: the front part of the VMS is closed by means of 1 hinged hatch, which opens
in a 90 angle; a gas compression spring keeps the hatch open.
The hatch has a fixed handle and n.2 locks that may be opened with a standard
Southco socket key in nickel plated steel.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.10

COMMUNICATION AND DISPLAY TECHNOLOGIES

The waterproof and dustproof features in the mobile coupling parts (hatch) are
ensured by the particular shape of the mechanical elements and by a 15x5mm flat
closed cell sealing in neoprene, glued to the internal hatch surface.

3.3) Electric characteristics / connections

Outside connections: the use of the following cables is advised:


- 3x2.5 mm2 cable, type FG7OR 0,6/1KV for 230VAC power supply
- 3x22AWG cable, triple shielded twisted pairs, cable sheath in polyurethane
for serial connection (RS 485 with possible local connections)
- UTP cat 5 cable, cable sheath in polyurethane for Ethernet connection
- Multipolar control cable for dry contacts control.
- Singe mode optical fiber cable (if optical fiber connection is foreseen)

Internal cables: the internal connections, for the power supply part, are realized with
cable conductors and cable electric ducts.
The unipolar power supply 230VAC is wired with cables having a 1.5 mm2 minimum
cross-section.
Phase = brown
Neutral = blue
Ground = yellow/green

The power supply cable comes to a terminal board identified with:


1 = phase 230VAC
2 = neutral 230VAC
T = ground

In the model with connectors, the power supply and the control signals are managed
by the connector itself.

The 230VAC connection parts are duly sheltered from accidental contacts and duly
identified.

The terminal board for the serial RS485 line is identified as follows:
7 = common
8 = - RS485
9 = + RS485

The central CPU is equipped with RJ45 female connection for Ethernet.

Conductors with different sections are used for low powered connections (5VDC,
12VDC and 24VDC power supply) to reach the single boards:

(led board supply)


+12VDC (+led) = red 1,5mmq
+5VDC (+logic) = orange 1,5mmq
0VDC = black 1,5mmq
On polarized connector

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.11

COMMUNICATION AND DISPLAY TECHNOLOGIES

The connections of the control signals between the CPU board and LED boards are
actuated with a flat cross-sectioned cable and polarized connectors.

All cables are in compliance with CEI 20-22.

Electronic boards: electronic components are mounted on aluminium supports


equipped with threaded male or female inserts, in connection with the casing thanks to
screws and rivets (in case maintenance disassembling is not required). The
assembling of the components is done putting boards, power suppliers etc. in
correspondence of each relevant insert, and completing the fixing with self blocking
nuts, which, in case of maintenance, can be easily removed with standard tools
(usually a 5,5mm hexagonal socket key is enough).

Each LED circuit board (p.c.b. 0607) is mounted on 3MA male inserts and blocked
with 3MA self-blocking nuts; the replacement of a board requires the extraction of the
connector (one power supply connector with max. 12VDC power and one of flat cable
signal) and the unscrewing 3MA nuts. The operation requires a 5,5mm hexagonal
socket key.

CPU board with expansion (p.c.b. 0429+0216) is mounted with 3MA inserts and nuts;
all connectors are polarized and marked to facilitate recovery in case of
replacement/maintenance.

The control board (p.c.b. 0504) is mounted on 3MA inserts and nuts, its replacement
requires the extraction of the connectors and the unscrewing of the self-blocking 3MA
nuts.

Serial line termination board (p.c.b. 0930) is mounted on top of the CPU + expansion
ensemble only on panels foreseeing a serial line command.

Optical fiber converter (10-100B-TX : 100BFX Media Converter) is mounted on the


inside panel only for the versions which foresee optical fiber command.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.12

COMMUNICATION AND DISPLAY TECHNOLOGIES

4) Function
Upon switch-on the panel, in absence of programmed messages, the panel displays
the blank status (no symbol).
In case of serial line, Ethernet or optical fiber command from the Host, that manages
the VMS active locations of the network located in the control centre, it is possible to
activate at any time the display of a pictogram of the graphic display and of a message
on the alphanumeric display.

Upon switch on, the dry contacts version may display two different status: blank (no
symbol) or red cross, according to the previously defined configuration (on the
highway/in tunnel or toll station).

The message activation modalities are illustrated in the specific manual.

The panels may be programmed with a series of parameters that set the functions
under standard and particular conditions:
- Brightness level: the panel keeps the led brightness at a fixed value.
- Automatic brightness: the panel is equipped with a brightness sensor.

4.1) Communication protocol

Each panel is equipped with a panel control board, with 10/100 TX Ethernet
connection for the wiring to the LAN net.
This board makes it possible to define an IP address specific for each panel in order
to establish a connection to the management host of the VMS installations.
The LAN network structure for the connection to the installations and the IP address is
described separately.
The communication between the management host and the installations happens
through a data exchange whose specific format is described in the relevant manual.
The connection to the central unit is possible thanks to a RS 485 serial connection
with specific protocol as well.

In the dry contacts version the activation of the pictograms from remote control
happens through an electric contact free from power: relays contact with 10mA
24VDC max. power derived from the panel, the maximum distance allowed between
the controls and the panels (connection wire length) is no more than 300m.
For what concerns the wiring please note the attached documentation.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.13

COMMUNICATION AND DISPLAY TECHNOLOGIES

5) Reliability and maintenance


The VerbaTRAFFIC panels have been designed while taking into consideration the
critical elements that interfere with reliability and ease of maintenance:
- Sturdy mechanical structure, made of materials resistant to aggressive agents and
vibrations
- Electronic components with a high MTBF (Mean Time Between Failures)
- Precise wiring
- Static led control
- Tested firmware
- Board modularity
- High level of function integration
- Reduction of the number of mechanical and electric elements

5.1) Preventive maintenance

The panel is composed of static elements that under normal circumstances do not
require maintenance aimed at preventing breakdowns and/or malfunctions due to
component wear.

5.2) Corrective maintenance

For the elements, described in the previous paragraphs, replacement is necessary if


breakdowns or malfunctions are detected:
- cut power off
- unlink the electric connector from the damaged device
- unscrew the M3 self-blocking nuts that clamp the device; the use of a 5.5mm hex
socket wrench is advised for this operation
- replace the component, restore screws and connections
- switch-on power supply and test the device
The other components, of electric and electronic nature, are modular elements,
mechanically mounted on support frames by means of threaded inserts (solid with the
frame), with any dividers in insulating materials and M3 self-blocking nuts: in order to
replace the component (LED circuit board, CPU board, temperature sensor board,
signal distribution board, AC/DC power supply unit, service lighting, service sockets)
the use of a 5.5mm hex socket wrench to unscrew the self-blocking M3 nuts will
suffice. The electric board connections are realized with extractable polarized
connectors; before board removal assure that all connectors have been unlinked.
All the conductors for the power supply units are wired to the equipment terminals:
disconnect the cables (the conductors are identified by a colour code:
yellow/green=ground, blue=neutral 230VAC, brown=phase 230VAC, red=+12 VDC,
black=0VDC, orange=+5 VDC logic), from the power supply unit terminals (the anti-
loosening terminals are identified by a plate that specifies their purposes); unscrew the
nuts securing to the frame; replace with equipment of identical model; rewire and test
the functioning.
NOTE: replacement interventions of broken or malfunctioning components
must be executed while power is switched-off and only by trained technicians.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.14

COMMUNICATION AND DISPLAY TECHNOLOGIES

5.3) Main spare parts list

5.3.1) FCxS500

CUSTOMER
Description AESYS CODE
CODE (optional)
Switching power supply 230VAC/12VDC/150W 11037009
Switching power supply 230VAC/5VDC/60W 11037014
Switching power supply 230VAC/24VDC/25W 11037024
Led board 4S (p.c.b. 0607) down-right (considering the front side of
14003756
the panel)
Led board 4S (p.c.b. 0607) down-left (considering the front side of the 14003757
panel)
Led board 4S (p.c.b. 0607) upper-right (considering the front side of 14003758
the panel)
Led board 4S (p.c.b. 0607) upper-left (considering the front side of the 14003759
panel)
Led board 2S (p.c.b. 0607) down-right (considering the front side of
140031112
the panel)
Led board 2S (p.c.b. 0607) down-left (considering the front side of the 140031113
panel)
Led board 2S (p.c.b. 0607) upper-right (considering the front side of 140031114
the panel)
Led board 2S (p.c.b. 0607) upper-left (considering the front side of the 140031115
panel)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) + Serial
54039332-R001
Line Termination board (p.c.b. 0930)
Controller board (p.c.b. 0504) 14003692
Southco door lock E3-55-75 13018063

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.15

COMMUNICATION AND DISPLAY TECHNOLOGIES

5.3.2) FCxS500 with rear PG connectors

CUSTOMER
Description AESYS CODE
CODE (optional)
Switching power supply 230VAC/12VDC/150W 11037009
Switching power supply 230VAC/5VDC/60W 11037014
Switching power supply 230VAC/24VDC/25W 11037024
Led board 4S (p.c.b. 0607) down-right (considering the front side of
14003756
the panel)
Led board 4S (p.c.b. 0607) down-left (considering the front side of the 14003757
panel)
Led board 4S (p.c.b. 0607) upper-right (considering the front side of 14003758
the panel)
Led board 4S (p.c.b. 0607) upper-left (considering the front side of the 14003759
panel)
Led board 2S (p.c.b. 0607) down-right (considering the front side of
140031112
the panel)
Led board 2S (p.c.b. 0607) down-left (considering the front side of the 140031113
panel)
Led board 2S (p.c.b. 0607) upper-right (considering the front side of 140031114
the panel)
Led board 2S (p.c.b. 0607) upper-left (considering the front side of the 140031115
panel)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) + Serial
54039332-R001
Line Termination board (p.c.b. 0930) (Serial Line version)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) (Relays
54039301-R001
version)
Controller board (p.c.b. 0504) 14003692
Southco door lock E3-55-75 13018063

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.16

COMMUNICATION AND DISPLAY TECHNOLOGIES

5.3.3) FCxS500 with Buccaneer connectors

CUSTOMER
Description AESYS CODE
CODE (optional)
Switching power supply 230VAC/12VDC/150W 11037009
Switching power supply 230VAC/5VDC/60W 11037014
Switching power supply 230VAC/24VDC/25W 11037024
Led board 4S (p.c.b. 0607) down-right (considering the front side of
14003756
the panel)
Led board 4S (p.c.b. 0607) down-left (considering the front side of the 14003757
panel)
Led board 4S (p.c.b. 0607) upper-right (considering the front side of 14003758
the panel)
Led board 4S (p.c.b. 0607) upper-left (considering the front side of the 14003759
panel)
Led board 2S (p.c.b. 0607) down-right (considering the front side of
140031112
the panel)
Led board 2S (p.c.b. 0607) down-left (considering the front side of the 140031113
panel)
Led board 2S (p.c.b. 0607) upper-right (considering the front side of 140031114
the panel)
Led board 2S (p.c.b. 0607) upper-left (considering the front side of the 140031115
panel)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) + Serial
54039332-R001
Line Termination board (p.c.b. 0930) (Serial Line version)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216)
54039301-R001
(Ethernet version)
Controller board (p.c.b. 0504) 14003692
Buccaneer connector 3P 11039244
Buccaneer socket for 6P connector (Serial Line version) 11039241
Ethernet socket (Ethernet version) 11039466
Southco door lock E3-55-75 13018063

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.17

COMMUNICATION AND DISPLAY TECHNOLOGIES

5.3.4) FCxS500 with ILME connectors

CUSTOMER
Description AESYS CODE
CODE (optional)
Switching power supply 230VAC/12VDC/150W 11037009
Switching power supply 230VAC/5VDC/60W 11037014
Switching power supply 230VAC/24VDC/25W 11037024
Led board 4S (p.c.b. 0607) down-right (considering the front side of
14003756
the panel)
Led board 4S (p.c.b. 0607) down-left (considering the front side of the 14003757
panel)
Led board 4S (p.c.b. 0607) upper-right (considering the front side of 14003758
the panel)
Led board 4S (p.c.b. 0607) upper-left (considering the front side of the 14003759
panel)
Led board 2S (p.c.b. 0607) down-right (considering the front side of
140031112
the panel)
Led board 2S (p.c.b. 0607) down-left (considering the front side of the 140031113
panel)
Led board 2S (p.c.b. 0607) upper-right (considering the front side of 140031114
the panel)
Led board 2S (p.c.b. 0607) upper-left (considering the front side of the 140031115
panel)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) + Serial
54039332-R001
Line Termination board (p.c.b. 0930) (Serial Line version)
CPU board (p.c.b. 0429) + CPU Expansion board (p.c.b. 0216) (Dry
54039301-R001
Contacts or Optical Fiber version)
Controller board (p.c.b. 0504) 14003692
Media Converter 10-100B-TX : 100BFX (Optical Fiber version) 11102047
Southco door lock E3-55-75 13018063

Following is the description of the more important breakdowns that can occur and the
operational modalities for restoring full functionality.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.18

COMMUNICATION AND DISPLAY TECHNOLOGIES

5.4) Troubleshooting/diagnostics

The on-board panel CPU is able to detect and transmit to the local control unit some
panel functionality anomalies, for instance:
- Broken LED: the alphanumeric panel may be switched-off if more than n pixel are
in short circuit or interrupted; the diagnostic of the led functioning status is executed
continuously, on-line, with the panel switched-on and with message display active or
neutral presentation (all LED are off).
- Power supply availability
- Integrity of the serial communications line between the panel and control unit (time-
out: the panel switches-off automatically if communications with the ground control
unit are interrupted for a time range exceeding the one pre-configured).

N.B. The dry contacts version gives back only the executed reception of the
information, in order this to be used for a synoptic panel or else.

Breakdown search

The localization of broken LEDs, which may be displayed thanks to a test program on
a laptop, it is possible to see immediately the position of the LED boards that have to
be replaced.

Other possible break down are:

- The panel does not switch-on: check power supply voltage, switch and electric
protection positions; automatic switch in the panel in on position; power supply units
in the panel are live and functional (green LED is on);
CPU fed and connectors linked; blank message sent (all switched-off);
LED are off due to absence of communications with the control unit.

- The panel partially switches-on: if part of the panel remains off the possible
breakdown must be checked (or protection status due to short circuit or overcharge) in
the 12VDC power supply unit; if all the LED of a particular delimited area are off then
check the power supply of the corresponding LED circuit boards, check the
connectors; if a breakdown for more contiguous boards is suspected then replace the
boards one at a time starting from the left-most one (seen from behind) and test the
functionality for each replacement, verify the status of the board controller in
correspondence of the LED circuit boards that are off, verify sent message.

- Panel display is stuck on one message: verify possible communications defect on


the serial line, replace the CPU board.

- Luminosity cant be adjusted: verify photocell cleanliness (on the lower right side
of the screen); verify electric connections; verify that Host has not set a fixed
luminosity level, replace photo-sensor TSL235 on the first led circuit led board.

Manual FCxS500 ENG ev.0.doc (16.07.10)


pag.19

COMMUNICATION AND DISPLAY TECHNOLOGIES

6) Certifications and testing


Once mechanical and electric assembly has been finished, the panels undergo
accurate controls and tests. For each type of test general or electrical safety tests a
Q1204 form is filled out.
The tests described above also include luminance measurements by electronic device
CHROMA-METER CS 100 brand MINOLTA.

7) Labeling
The various devices (panels and control units) are identified by an adhesive label in
indelible characters applied on the back and on the interior sides of the panel with the
following data:
- Builder logo and address (Aesys)
- Homologation mark CE
- Panel name
- Serial number (s/n)
- Power supply allowed
- Maximum power required.

Manual FCxS500 ENG ev.0.doc (16.07.10)


COMMUNICATION AND DISPLAY TECHNOLOGIES TEST REPORT

Test Report

N: TRF S/N

Order n Nr Ordine SAP

SN PMV
Job n Nr Commessa SAP

Project Manager Responsabile di Commessa

Cod SAP
Model Serial Number (Label Above)
Nome PMV
Assembly Area
Data Compilazione Laboratory
Date Test Place Via Pastrengo 7c
gg/mm/aa
Seriate (BG) ITALY

STEP:

(A) HARDWARE/SOFTWARE SPECIFICATION CHECK AND DIAGNOSTIC

(B) GENERAL TEST

(C) ELECTRICAL TEST

(D) OPTICAL TEST LUMINANCE / CROMATICITY CO-ORDINATES

(E) OPTICAL TEST UNIFORMITY LUMINANCE

(F) IP Resistance - WATER PENETRATION RESISTANCE

Mod. Q1204 rev.04 08/04/10 - English Pag. 1 / 5


COMMUNICATION AND DISPLAY TECHNOLOGIES TEST REPORT

(A) Hardware/Software Specification Check and Diagnostic

Description Test Procedure


Voltage Regulation Multimeter
CPU Address Setting Dip switch settings
Firmware Version Specification SW Query
Address Configuration on LED Boards Dip switch settings
Test of communication - line RS 485 SW Query
Test of different Message Test Software
All pixel on Test Test Software
Min. Brightness Test SW Settings
Max. Brightness Test SW Settings
Automatic Brightness Test Software
Photocell verification (front/back) Electric Torch
Dip switch opening and software
Detection of open Led
verification
Verification of fan start-up T 30C Temperature Simulator
Verification of heater start-up T 8C Temperature Simulator
Check of Heater fan Visual
Check of re-circulating fan functioning Visual
Failure Simulation and software
Fan diagnostics verification
verification

Inspector: Date: Sign:


PASSED
Result: NOTE:
REJECTED

(B) General Test

Description Test Procedure


Wiring check Visual
Ground Cable on doors Visual
Welding check Visual
Screw/bolts tightening check Visual + Tools
Fixing point check Visual
Lock Check Visual + Key
Open / Close doors check Visual
Label Position check Visual
Identification Label check Visual
Painting Check Visual
External Sealing Visual
Internal Sealing Visual
Gasket Check Visual
Neon Light Check Visual

Inspector: Date: Sign:


PASSED
Result: NOTE:
REJECTED

Mod. Q1204 rev.04 08/04/10 - English Pag. 2 / 5


COMMUNICATION AND DISPLAY TECHNOLOGIES TEST REPORT

(C) Electrical Test

Ground protection circuit resistance


N TEST TEST POINTS MEASURED VALUE MAX. VALUE RULES REFERENCE
(m) (m)
1 100
2 100
3 100
4 100 CEI EN 50116
5 100 par. 5.1

6 100
7 100
8 100

Voltage applied
RULES
TEST POINTS Voltage applied (V) Time (s) Passed Rejected REFERENCE

F / PE (Phase / Ground) 1500V 5


CEI EN 50116
par. 5.2
N / PE (Neutral / Ground) 1500V 5

TESTS PERFORMED
According to CEI EN 50116 Serial Tests for the Electrical Safety Verification during construction:

Ground protection circuit resistance


Voltage applied

TEST RESULT
On the basis of the results above, we declare that the equipment has passed the tests according to the CEI
EN 50116 and CEI EN 60950 regulations.

Inspector: Date: Sign:


NOTE:

Mod. Q1204 rev.04 08/04/10 - English Pag. 3 / 5


COMMUNICATION AND DISPLAY TECHNOLOGIES TEST REPORT

(D) Optical Test - LUMINANCE / CROMATICITY CO-ORDINATES


Enviromental T =...C Internal T =.C (measured on the probe)

Monocromatic Display RGBY Display


Measured Cromaticity Cromaticity
Luminance
Co-ordinates
Cd / Mq Co-ordinates
Value
Max. Luminance Red Min. X= Y=

Min Luminance Max. X= Y=

Cromaticity Co-ordinates X = Green Min. X= Y=


Max. Luminance Y =
Cromaticity Co-ordinates X = Max. X= Y=
Min. Luminance Y =
Blue Min. X= Y=

Max. X= Y=

Yellow Min. X= Y=
(Combined)
Max. X= Y=

White Min. X= Y=
(Balanced)
Max. X= Y=

White Min. X= Y=
(Combined)
Max. X= Y=

Inspector: Date Sign

Note:

(E) Optical TestUNIFORMITY LUMINANCE


Visual test made by technician with all leds of active area lighted up in order to check uniformity.

Inspector: Date: Sign:


PASSED
Result: NOTE:
REJECTED

Mod. Q1204 rev.04 08/04/10 - English Pag. 4 / 5


COMMUNICATION AND DISPLAY TECHNOLOGIES TEST REPORT

(F) IP Resistance WATER PENETRATION RESISTANCE

Description
IP Protection Level..
Monitor Nozzle N .
Theorical Flow Rate (12,5 l/min.)
Measured Flow Rate (Measured with flowmeter ....) l/min..

Duration (3 min. x mt/q) min

Inspector: Date: Sign:


PASSED
Result: NOTE:
REJECTED

Note:

Mod. Q1204 rev.04 08/04/10 - English Pag. 5 / 5


8 7 6 5 4 3 2 1
690 183 SEE SHEET 2 FOR CABLES
CONNECTION ALTERNATIVES
20 650 20 26 150 7 Vedere foglio 2 per le alternative
di collegamento cavi
10

F F
175

25

M8x12
60
660

650

300

E E
SUPPORTING PIN
Perno di supporto
175

Signature
LOCK
FRONT VIEW LIGHT SENSOR SIDE VIEW REAR VIEW
D Vista frontale D
Serratura Sensore di luminosit Vista laterale Vista posteriore

Date
material check
In acceptance
GREEN ARROW PICTOGRAM RED CROSS PICTOGRAM
Pittogramma freccia verde Pittogramma croce rossa
INSPECTION DOOR
Portella d'ispezione

Work copy
C C
0 90

External work
copy
YELLOW LEFT ARROW PICTOGRAM YELLOW RIGHT ARROW PICTOGRAM
Pittogramma freccia gialla sinistra B
B Pittogramma freccia gialla destra
(*) TOP VIEW
(*)

working nr.
Vista dall'alto

Valid for
Revisions chronology/Cronologia Revisioni
Rev. Description/Descrizione Date/Data Author/ Autore Approved/Approvato
0 First release 31/03/2008 Tasca D. Nozza G.
1 Ilme connectors deleted 31/07/2008 Tasca D. Nozza G.
2 General revision 01/10/2008 Tasca D. Nozza G.
3 General revision 26/05/2009 Tasca D. Nozza G.
ISOMETRIC VIEW 4 Type "A" - RS485 model added 10/09/2009 Tasca D. Nozza G.
5 Sheet 2 modified 22/04/2010 Tasca D.
Vista assonometrica Finish/Finitura Sheet format/ Scale/Scala
Nozza G.
Formato foglio
/ A3 horiz. 1:8
A Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Aesys S.p.A. / Dove non specificato
25
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Tel. +39 035 29240 Fax. +39 035 680030 Object/Oggetto Sheet/Foglio
e-mail: info@aesys.it
www.aesys.it Display VerbaTRAFFIC FCxS500 1 of/di2
(*) = ONLY AVAILABLE FOR 4-STATE VERSION (SEE SHEET 2) With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione
or made know to public without AESYS authorization
Drawing nr./ N Disegno Revisions/Revisione
Disponibile solo per la versione a 4 stati (vedere foglio 2) DIMENSIONAL VIEWS
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 01 5
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
PICTOGRAMS CONNECTIONS
CODE Pittogrammi Collegamenti
10-POLES CONNECTORS (SOCKET Codice
+ REMOVABLE PLUG) FOR DATA LINE
Connettore a 10 poli (presa
DATA LINE / Linea dati POWER SUPPLY / Alimentazione elettrica
+ spina volante) per linea dati
9 9
TYPE "A" - RELAY CONTROLLED TYPE "A" - Tipo "A" F
F 995100 900600 Tipo "A" - controllata da rel 230VAC 50/60Hz
6-POLES CONNECTORS (PLUG
+ REMOVABLE SOKET) FOR POWER SUPPLY N2 PG13,5 CABLE GLANDS FOR DATA LINE
Connettore a 6 poli (spina + presa AND POWER SUPPLY CABLES INLET
9 9
volante) per alimentazione elettrica TYPE "B" - RELAY CONTROLLED TYPE "B" - Tipo "B"
N2 pressacavi PG13,5 per ingresso 995100 900601 Tipo "B" - controllata da rel 230VAC 50/60Hz
cavi linea dati ed alimentazione elettrica
26
9 9 9 9
TYPE "A" - RELAY CONTROLLED TYPE "A" - Tipo "A"
995100 801300
45

Tipo "A" - controllata da rel 230VAC 50/60Hz


9 9 9 9
TYPE "C" - RELAY CONTROLLED TYPE "C" - Tipo "C"
995100 801302 Tipo "C" - controllata da rel
E
230VAC 50/60Hz E
9 9 9 9
TYPE "C" - RELAY CONTROLLED TYPE "C" - Tipo "C"
995100 801303 Tipo "C" - controllata da rel 230VAC 50/60Hz
(36 version)
9 9 9 9
TYPE "D" - RS485 SERIAL TYPE "D" - Tipo "D"

Signature
995100 801304 Tipo "D" - seriale RS485 230VAC 50/60Hz
SIDE VIEW REAR VIEW SIDE VIEW REAR VIEW
Vista laterale Vista posteriore Vista laterale Vista posteriore
9 9 9 9
TYPE "D" - ETHERNET LINE TYPE "D" - Tipo "D"
995100 801305 Tipo "D" - Linea ethernet 230VAC 50/60Hz
D D
9 9 9 9
TYPE "B" - RS485 SERIAL TYPE "B" - Tipo "B"
TYPE "A" CONNECTIONS TYPE "B" CONNECTIONS

Date
995100 801301 Tipo "B" - seriale RS485 230VAC 50/60Hz
Collegamenti tipo "A" Collegamenti tipo "B"

material check
In acceptance
9 9 9 9
TYPE "A" - RS485 SERIAL TYPE "A" - Tipo "A"
995100 801306 Tipo "A" - seriale RS485 230VAC 50/60Hz
6-POLES (ALTERNATIVE: RJ45) CONNECTORS
SIDE VIEW REAR VIEW (SOCKET + REMOVABLE PLUG) FOR DATA LINE
VIsta laterale Connettore a 6 poli (in alternativa: RJ45)
9 9 9 9
Vista posteriore TYPE "A" - ETHERNET (optical fiber) TYPE "A" - Tipo "A"
(presa + spina volante) per linea dati 995100 801307 Tipo "A" - Ethernet in fibra ottica 230VAC 50/60Hz

Work copy
26 C
C
3-POLES CONNECTORS (PLUG
+ REMOVABLE SOCKET) FOR POWER SUPPLY
1m

CABLE
Cavo Connettore a 3 poli (spina + presa volante)
per alimentazione elettrica

External work
17

copy
B B

working nr.
Valid for
6-POLES CONNECTORS (PLUG ON CABLE
+ REMOVABLE SOCKET) FOR POWER SUPPLY Revisions chronology/Cronologia Revisioni
Connettore a 6 poli (spina su cavo + presa Rev. Description/Descrizione Date/Data Author/ Autore Approved/Approvato
volante) per alimentazione elettrica 0 First release 31/03/2008 Tasca D. Nozza G.
1 Ilme connectors deleted 31/07/2008 Tasca D. Nozza G.
01/10/2008 Tasca D.
SIDE VIEW REAR VIEW 2 General revision Nozza G.
3 General revision 26/05/2009 Tasca D. Nozza G.
10-POLES CONNECTORS (SOCKET ON CABLE Vista laterale Vista posteriore Type "A" - RS485 model added
4 10/09/2009 Tasca D. Nozza G.
+ REMOVABLE PLUG) FOR DATA LINE 5 Sheet 2 modified 22/04/2010 Tasca D. Nozza G.
Connettore a 10 poli (presa su cavo Finish/Finitura Sheet format/ Scale/Scala
Formato foglio
+ spina volante) per linea dati / A3 horiz. 1:8
A Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Aesys S.p.A. / Dove non specificato
25
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
TYPE "C" CONNECTIONS TYPE "D" CONNECTIONS Tel. +39 035 29240 Fax. +39 035 680030
e-mail: info@aesys.it
Object/Oggetto Sheet/Foglio
2 of/di2
www.aesys.it Display VerbaTRAFFIC FCxS500
Collegamenti tipo "C" Collegamenti tipo "D" With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione
or made know to public without AESYS authorization
Drawing nr./ N Disegno Revisions/Revisione
DIMENSIONAL VIEWS
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 01 5
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
695
159,5 600
650
F F
45

SLOTS 10x20
Asole 10x20
3 4 5
FRONT E
695

E
650

350

Signature
1
D D
2
FRONT VIEW SIDE VIEW REAR VIEW

Date
Vista frontale Vista laterale Vista posteriore

material check
In acceptance
Work copy
C C

External work
copy
Parts list/Elenco parti
Pos. Q.ty Code AESYS Description Material
B B
1 1 72 017 1 19 Bracket for support on the wall Fe 20/10
2 1 995100801300 Display VerbaTRAFFIC FC4S500 /

working nr.
Valid for
3 4 13009037 Hexag.-Head Screw M8x20 UNI5739 Galvanized steel
4 4 13010005 Plain washer M8 UNI6592 Galvanized steel
5 4 13010009 Grower washer M8 Galvanized steel
Revisions chronology/Cronologia Revisioni
ISOMETRIC VIEW Rev. Description/Descrizione Date/Data Author/Autore Approved/ Approvato
Vista assonometrica 0 First release 26/11/2008 Tasca D. G. Nozza
1
2
3
4
Finish/Finitura Scale/Scala
/ A3 horiz. 1:8
A Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Aesys S.p.A. / Dove non specificato
34.9
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Tel. +39 035 29240 Fax. +39 035 680030 Object/Oggetto Sheet/Foglio
e-mail: info@aesys.it
www.aesys.it 1 of/di1
Description/Descrizione Drawing nr./ N Disegno Revisions/Revisione
DIMENSIONAL VIEWS
Viste dimensionali 72 017 4 05
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
874 200
100 674 100 40 150 10 2
F F
A A
150

2
E E
800

Signature
D D
SLOT FOR SLOPE REGULATION
125

Asola per regolazione inclinazione

Date
B
==

material check
In acceptance
5
FRONT VIEW
Vista frontale SIDE VIEW ISOMETRIC VIEW
Vista laterale Vista assonometrica

Work copy
C C
200

External work
25 150 25

copy
25

4 Parts list/Elenco parti


Pos. Q.ty Code AESYS Description Material Weight Length
B 5 B
1 1 995100801304 Display VerbaTRAFFIC FC4S500 24.713 kg
2 2 72 017 2 05 Ceiling support assembly Stainless steel 2.875 kg

working nr.
Valid for
3 4 13009142 Hexag.-Head Screw M8x12 UNI5739 Galv. steel 0.011 kg
200

150 4 4 13010009 Grower washer M8 C70 Galv. steel 0.002 kg


5 4 13010027 Wide washer M8 UNI6593 Galv. steel 0.006 kg
Revisions chronology/Cronologia Revisioni
Rev. Description/Descrizione Date/Data Author/Autore Approved/ Approvato
Q22 0 First release 31/08/2009 Tasca D. Nozza G.
1 Updated 05/08/2009 Tasca D. Nozza G.
2
3
3
4
Finish/Finitura Scale/Scala

25
/ A3 horiz. 1:8
A Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Aesys S.p.A. / Dove non specificato
30.5
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
SECTION / Sezione "A-A" DETAIL / Dettaglio "B" Tel. +39 035 29240 Fax. +39 035 680030
e-mail: info@aesys.it
Object/Oggetto Sheet/Foglio
( 1:3 ) www.aesys.it 1 of/di1
Description/Descrizione Drawing nr./ N Disegno Revisions/Revisione
VMS ASSEMBLY WITH SUPPORT
Assieme PMV con staffe 72 017 4 13 0
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
707
28,5 650 28,5 148,5
325 325 10 100 38,5 5 5
F F
Q20 2
75

25

5
8
135

4 6 7 E
E
860

FRONT
FRONT

FRONT
650

Signature
D D

Date
material check
In acceptance
FRONT VIEW 3 SIDE VIEW VMS CAN BE INCLINED TILL +/-5
Vista frontale
Vista laterale Il pannello pu essere inclinato fino a +/-5

Work copy
C C

External work
copy
Parts list/Elenco parti
Pos Q.ty Code AESYS Description Material
1 1 72 017 2 02 Support from top Stainless Steel
2 1 72 017 2 03 Counter support from top Stainless Steel
3 1 995100801300 Display VerbaTRAFFIC FC4S500 /
B B
4 4 13009283 Hexag.-Head Screw M8x20 UNI5739 Stainless Steel
5 1 13009546 Hexag.-Head Screw M18x70 UNI5739 Stainless Steel

working nr.
Valid for
6 4 13010042 Plain washer M8 UNI6592 Stainless Steel
7 4 13010043 Grower washer M8 Stainless Steel
8 1 13011087 M18 Hexagon self-locking nut DIN985 Stainless Steel
Revisions chronology/Cronologia Revisioni
ISOMETRIC VIEW Rev. Description/Descrizione Date/Data Author/ Autore Approved/ Approvato
Vista assonometrica 0 First release 26/11/2008 Tasca D. G. Nozza
1
2
3
4
Finish/Finitura Sheet format/ Scale/Scala
Formato foglio
/ A3 horiz. 1:8
A Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Aesys S.p.A. / Dove non specificato
34.9
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Tel. +39 035 29240 Fax. +39 035 680030 Object/Oggetto Sheet/Foglio
e-mail: info@aesys.it
www.aesys.it Display VerbaTRAFFIC FC4S500 + support from top 1 of/ di1
With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione Drawing nr./ N Disegno Revisions/Revisione
or made know to public without AESYS authorization
DIMENSIONAL VIEWS
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 04
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
707 200
28,5 650 28,5 148,5 5 5
F
F 325 325 10 38,5
38

2
Q20
D D
29 75

25

8
9
4 6 7
E E
792

FRONT
FRONT

FRONT
650

Signature
D D

Date
3

material check
In acceptance
FRONT VIEW
SIDE VIEW VMS CAN BE INCLINED TILL +/-5
Vista frontale
Vista laterale Il pannello pu essere inclinato fino a +/-5

Work copy
C C

External work
copy
Parts list/Elenco parti
Pos Q.ty Code AESYS Description Material
SECTION / Sezione "D-D" 1 1 72 017 2 04 Support from top Stainless Steel
ANCHORING PLATE DETAIL 2 1 72 017 2 03 Counter support from top Stainless Steel
Dettaglio piastra di fissaggio
3 1 995100801304 Display VerbaTRAFFIC FC4S500 /
B B

25
4 4 13009283 Hexag.-Head Screw M8x20 UNI5739 Stainless Steel
6 4 13010042 Plain washer M8 UNI6592 Stainless Steel

working nr.
Valid for
7 4 13010043 Grower washer M8 Stainless Steel
8 1 13011087 M18 Hexagon self-locking nut DIN985 Stainless Steel
Q15

200
9 1 13009546 Hexag.-Head Screw M18x70 UNI5739 Stainless Steel
Revisions chronology/Cronologia Revisioni
Rev. Description/Descrizione Date/Data Author/ Autore Approved/ Approvato
0 First release 26/11/2008 Tasca D. G. Nozza
1
2

25
25 25 3
4
Finish/Finitura Sheet format/ Scale/Scala
Formato foglio
200 / A3 horiz. 1:8
A ISOMETRIC VIEW Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
Vista assonometrica Aesys S.p.A. / Dove non specificato
37.9
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Tel. +39 035 29240 Fax. +39 035 680030 Object/Oggetto Sheet/Foglio
e-mail: info@aesys.it
www.aesys.it Display VerbaTRAFFIC FC4S500 + support from top 1 of/ di1
With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione Drawing nr./ N Disegno Revisions/Revisione
or made know to public without AESYS authorization
DIMENSIONAL VIEWS
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 08
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
HOLES FOR HEIGHT REGULATION
Fori per regolazione in altezza
F F
1
56 327
48
10

SLOT FOR SLOPE REGULATION


180

4 E
E Asola per regolazione inclinazione
A A
133

12 10 5

Signature
963

11 8 7
860

D D
2
650

Date
3

material check
In acceptance
ISOMETRIC VIEWS

55
VIsta assonometrica

Work copy
C C
650
DIMENSIONAL VIEWS
Viste dimensionali 1 6 8 9

External work
copy
200
25 150 25
B B

25

working nr.
Valid for
Parts list/Elenco parti
Pos Q.ty Code AESYS Description Material Weight Length Q12 Revisions chronology/Cronologia Revisioni
1 1 995100801306 Display VerbaTRAFFIC FC4S500 / 25,181 kg Rev. Description/Descrizione Date/Data Author/ Autore Approved/Approvato

160

110
2 1 72 017 1 43 Tubo di supporto - tipo 3 AISI 316 L 4,437 kg 860 mm 0 First release 22/10/2009 Tasca D. Nozza G.
3 1 72 017 2 11 Telaio di sostegno / 6,344 kg 1
2
4 1 72 017 2 13 Assieme staffa superiore - tipo 2 / 5,849 kg 3
5 2 13009597 Hexag.-Head Screw M12x110 UNI5737 Stainless steel 0,112 kg 4
Finish/Finitura Sheet format/ Scale/Scala
6 4 13009283 Hexag.-Head Screw M8x20 UNI5739 Stainless Steel 0,020 kg Formato foglio
/ A3 horiz. 1:10
A 7 2 13009393 Hexag.-Head Screw M8x80 UNI5737 Stainless steel 0,038 kg Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A

25
dimensions are in mm
8 8 13010042 M8 plain washer A2 UNI6592 Stainless Steel 0,002 kg Aesys S.p.A. / Dove non specificato
38.7
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Object/Oggetto Sheet/Foglio
9 4 13010043 M8 grower washer A2 Stainless Steel 0,002 kg Tel. +39 035 29240 Fax. +39 035 680030
e-mail: info@aesys.it
10 4 13010122 M12 plain washer A2 UNI6592 Stainless Steel 0,006 kg SECTION / Sezione "A-A" www.aesys.it Display VerbaTRAFFIC FC4S500 + ceiling support L=860mm 1 of/di1
With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione Drawing nr./ N Disegno Revisions/Revisione
11 2 13011034 M8 self-locking nut DIN985 Stainless steel 0,006 kg ( 1:3 ) or made know to public without AESYS authorization
DIMENSIONAL VIEWS
12 2 13011088 M12 self-locking nut DIN985 Stainless steel 0,017 kg
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 16 0
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
16 307
30

4
10
180

F F
A A
SLOT FOR SLOPE REGULATION 12 10 5
Asola per regolazione inclinazione
E E
2
1065

HOLES FOR HEIGHT REGULATION

Signature
Fori per regolazione in altezza
1700

1
DIMENSIONAL VIEWS
1895

Viste dimensionali
D D

Date
material check
In acceptance
Work copy
C C
11 8 7
650

External work
3

copy
1 6 8 9

165
ISOMETRIC VIEWS
VIsta assonometrica
B B
650 160

working nr.
Valid for
20 120 20
Parts list/Elenco parti
Pos Q.ty Code AESYS Description Material Weight Length
Revisions chronology/Cronologia Revisioni

15
1 1 995100801306 Display VerbaTRAFFIC FC4S500 / 25,183 kg Rev. Description/Descrizione Date/Data Author/ Autore Approved/Approvato
2 1 72 017 1 41 Tubo di supporto - tipo 1 AISI 316 L 8,817 kg 1700 mm 0 First release 11/09/2009 Tasca D. Nozza G.
3 1 72 017 2 11 Telaio di sostegno / 6,344 kg 1
2
4 1 72 017 2 12 Assieme staffa superiore / 3,074 kg

100

70
3
5 2 13009597 Hexag.-Head Screw M12x110 UNI5737 Stainless steel 0,112 kg 4
Finish/Finitura Sheet format/ Scale/Scala
6 4 13009283 Hexag.-Head Screw M8x20 UNI5739 Stainless Steel 0,020 kg Formato foglio
/ A3 horiz. 1:10
A 7 2 13009393 Hexag.-Head Screw M8x80 UNI5737 Stainless steel 0,038 kg Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm

15
8 8 13010042 M8 plain washer A2 UNI6592 Stainless Steel 0,002 kg Aesys S.p.A. / Dove non specificato
43.8
Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Object/Oggetto Sheet/Foglio
9 4 13010043 M8 grower washer A2 Stainless Steel 0,002 kg Tel. +39 035 29240 Fax. +39 035 680030
e-mail: info@aesys.it
10 4 13010122 M12 plain washer A2 UNI6592 Stainless Steel 0,006 kg www.aesys.it Display VerbaTRAFFIC FC4S500 + ceiling support L=1700mm 1 of/di1
SECTION / Sezione "A-A" With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione Drawing nr./ N Disegno Revisions/Revisione
11 2 13011034 M8 self-locking nut DIN985 Stainless steel 0,006 kg ( 1:3 ) or made know to public without AESYS authorization
DIMENSIONAL VIEWS
12 2 13011088 M12 self-locking nut DIN985 Stainless steel 0,017 kg
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 14 0
8 7 6 5 4 3 2 1
8 7 6 5 4 3 2 1
HOLES FOR HEIGHT REGULATION
Fori per regolazione in altezza
F F
1
307
16
30

SLOT FOR SLOPE REGULATION


10

E E
180

Asola per regolazione inclinazione 4


A A
85

12 10 5

Signature
720
915

11 8 7
2
D D
650

Date
material check
In acceptance
165
ISOMETRIC VIEWS
VIsta assonometrica

Work copy
C 650 C
DIMENSIONAL VIEWS 1 6 8 9
Viste dimensionali

External work
copy
160
20 120 20 B
B

working nr.
Valid for
15
Parts list/Elenco parti
Pos Q.ty Code AESYS Description Material Weight Length
Revisions chronology/Cronologia Revisioni
1 1 995100801306 Display VerbaTRAFFIC FC4S500 / 25,183 kg Rev. Description/Descrizione Date/Data Author/ Autore Approved/Approvato

100

70
2 1 72 017 1 42 Tubo di supporto - tipo 2 AISI 316 L 3,713 kg 720 mm 0 First release 11/09/2009 Tasca D. Nozza G.
3 1 72 017 2 11 Telaio di sostegno / 6,344 kg 1
2
4 1 72 017 2 12 Assieme staffa superiore / 3,074 kg 3
5 2 13009597 Hexag.-Head Screw M12x110 UNI5737 Stainless steel 0,112 kg 4

15
Finish/Finitura Sheet format/ Scale/Scala
6 4 13009283 Hexag.-Head Screw M8x20 UNI5739 Stainless Steel 0,020 kg Formato foglio
/ A3 horiz. 1:10
A 7 2 13009393 Hexag.-Head Screw M8x80 UNI5737 Stainless steel 0,038 kg Material and thickness/Materiale e spessore Where not specified Weight/Peso (kg)
A
dimensions are in mm
8 8 13010042 M8 plain washer A2 UNI6592 Stainless Steel 0,002 kg Aesys S.p.A. / Dove non specificato
38.7
SECTION / Sezione "A-A" Via Pastrengo, 7/C 24068 Seriate (BG) Italy
le dimensioni sono in mm
Sheet/Foglio
9 4 13010043 M8 grower washer A2 Stainless Steel 0,002 kg Tel. +39 035 29240 Fax. +39 035 680030 Object/Oggetto
( 1:3 ) e-mail: info@aesys.it
10 4 13010122 M12 plain washer A2 UNI6592 Stainless Steel 0,006 kg www.aesys.it Display VerbaTRAFFIC FC4S500 + ceiling support L=720mm 1 of/di1
With reserve to act in legal terms this drawing cannot be reproduced Description/ Descrizione Drawing nr./ N Disegno Revisions/Revisione
11 2 13011034 M8 self-locking nut DIN985 Stainless steel 0,006 kg or made know to public without AESYS authorization
DIMENSIONAL VIEWS
12 2 13011088 M12 self-locking nut DIN985 Stainless steel 0,017 kg
E' vietata la duplicazione anche parziale del presente documento, previa
autorizzazione scritta dell' Aesys con riserva di agire a termini di legge Viste dimensionali 72 017 4 15 0
8 7 6 5 4 3 2 1

Anda mungkin juga menyukai