Next, if the particles were no-porous then the smaller size (runs 1 e 2) should have double the
rate of the larger size ( runs 3 e 4)This is not what is measured hence the results are not
consisten with the guess of non-porous particles.
Alright, let us see if the results are consistent with the assumption of porous particles.
- if in the regime of no pore diffusion resistance the rates should be the same for large e small
pellets
- if in the regime of strong pore diffusion the rate should halve from 4 to 2 in going to the large
particles
Our results are 1/2 way. between these two extremes, hence we must be operating under
conditions where pore diffusion is just beginning to influence the rate.
Thus we conclude:
traduo:
Todas estas corridas foram feitas no mesmo W / Fao. Tambm nos dito que a taxa de
reciclagem alta o suficiente para ter fluxo misturado em toda. Assim, mudar a taxa de
reciclagem do rum 1 para 2, ou da corrida 3 para 4 sem alterao na taxa mostra que a
resistncia do filme no influencia a taxa.
- se no regime de ausncia de resistncia difuso dos poros as taxas deveriam ser as mesmas
para as grandes e pequenas pastilhas
- se no regime de difuso de poros forte a taxa deve reduzir para metade de 4 para 2 em ir
para as partculas grandes
Nossos resultados so meio caminho. Entre esses dois extremos, portanto, devemos estar
operando em condies onde a difuso de poros est apenas comeando a influenciar a taxa.
Assim, conclumos: