INDICE
I. OBJETIVOS__________________________________________________________2
II. FUNDAMENTO TEORICO_______________________________________________2
III. DATOS EXPERIMENTALES_____________________________________________2
IV. CALCULOS Y RESULTADOS____________________________________________2
V. DISCUSIONES________________________________________________________2
VI. CONCLUSIONES____________________________________________________2
VII. CUESTIONARIO____________________________________________________2
VIII. PROBLEMAS______________________________________________________2
I. OBJETIVOS
B. Tipos de intercambiadores
- Torres de enfriamiento
- Coraza y tubos
- Evaporadores
- Placas
- Compacto
- Regeneradores
Ecuacin 1
D. Variacin de la temperatura
La figura 2 (a) muestra un intercambiador sencillo monotubo por la parte superior de la coraza
entra el fluido caliente y por el tubo concentrico entra el fluido fro. La figura 2 (b) muestra la
variacin de temperatura a travs de la pared del tubo y el circuito trmico correspondiente. El
calor fluye por conveccin a travs del fluido caliente, por conduccin a travs de la pared del
tubo y por conveccin al fluido fro. Como resultado de este proceso, la temperatura del fluido
fro se eleva a medida que ste gana energa a su paso por el tubo y el fluido caliente
disminuye su temperatura a medida que ste pierde energa a su paso por el tubo.
Ecuacin 2
Ecuacin 3
Ecuacin 4
Ecuacin 5
Ecuacin 6
Ecuacin 7
Ecuacin 8
Ecuacin 9
Ecuacin 10
Ecuacin 11
Entonces se obtiene;
Ecuacin 12
P=10 lb/pulg^2
vapor de agua agua tubera interna
0 0 0
Q c (LPM) T5( C) T1( C) T6( C) T7(0 C) 0
T2( C) T3(0 C) T4(0 C)
8 126,3 126,3 23,7 51,8 125,5 125,2 124,8
9 127,6 127,3 23,8 48,8 126,9 127 126
10 127,4 126,6 23,8 47,3 126,4 126,3 126
11 126,1 125,7 23,8 43,5 125,5 126,3 126
12 126,6 125,5 23,5 43,7 124,6 125,6 127,8
T(0 equipo
Datos del C)
tubera interna externa
material Acero inox. Fe negro
Di(mm) 20,93 52,2
Do(mm) 26,67 60
x(mm) 2,87 3,9
K(0-100 C) 17,3
L(m) 3,28
H2O(Kg/m
3)
994,08 35
990,64 44
988,47 49
986,62 53
984,66 57
i c , 0i c, i
Para el fluido frio: )
q c =mc
i c , ii c, o
Para el fluido caliente: )
Si no hay cambio de fase yqlos h=calores
m h especficos son constantes:
T 7T 6
Para el fluido frio: )
q c =mc Cp c
mc =Qc H 2 O
mcond =Q cond H 2 O
% perdida
N0 mc(Kg/s) m cond(Kg/s) qc (KJ/s) q cond(KJ/s)
calor
0,13293333 0,0084244 15,614083 19,013886
1 18%
3 1 5 1
29,575059
2 0,14955 0,0131037 15,627975 47%
3
0,16616666 0,0085879 16,322551 19,382943
3 16%
7 2 7 4
0,18278333 15,051476 16,171396
4 0,007165 7%
3 4 8
0,0067604 16,836538 15,258342
5 0,1994 10%
5 4 7
IV.2. Calcule el
coeficiente global experimental U0 referido al rea exterior A0.
T lm
)
q c =U 0 A 0
(T 5T 6 )(T 1T 7)
Tlm= T 5T 6
ln( )
UNIVERSIDAD NACIONAL DE INGENIERIA T 1T 7
8
LABORATORIO DE OPERACIONES UNITARIAS I
1 1 xw D0
U0 = hi 0 + K * D
W m
1
UNIVERSIDAD NACIONAL DE
+ INGENIERIA
h0
9
LABORATORIO DE OPERACIONES UNITARIAS I
N0 hi0(KW/0 C)
1 0,584
2 0,566
3 0,586
4 0,537
IV.5. con la ecuacin de Wilson
5 0,594
graficar 1/UA vs. 1/v^0,8 y el coeficiente
pelicular del condensado (h0) y del agua (hi).
1 1
= Rc+ Rd + Rw=C1+
UA C 2V 0,8
N0 UA 1/UA V 1/V^0,8
1 0,178 5,623 0,001 369,048
2 0,173 5,795 0,001 335,862
3 0,180 5,570 0,001 308,713
4 0,164 6,105 0,001 286,050
5 0,183 5,467 0,001 266,815
grafica de wilson
6.200
6.000
5.800
1/UA
5.600
5.400
260.000 280.000 300.000 320.000 340.000 360.000 380.000
5.200
5.000
1/V^0,8
La tendencia no el lineal, como lo deduce Wilson, as que esta experiencia no cumple con las
condiciones de la ecuacin.
A) Calcule el coeficiente Pelicular del condensado ho con la ecuacin 28, utilice los
mtodos de Kern y MacAdams, calcule el Reynolds y Nusselt.
h=0.729
Dimensiones:
[
K 3f 2f g f
Td 0uf ] 4
Do = 26,670 mm
L = 3,280 m
g = 9,810 m/s^2
Metodo kern
Tv+Tw
Tf=
2
Cauda
Tv Tw Tf Tf T Densidad uf K ho
l
(LPM) C C C K K Kg/m^3 J/Kg Kg/m.s W/m.K W/m^2.K
8 126.30 125.167 125.73 398.73 0.57 939.15 3.96E+07 6.21E-01 0.684553 7.580E+03
9 127.45 126.633 127.04 400.04 0.41 937.49 3.95E+07 6.21E-01 0.684766 8.219E+03
10 127.00 126.233 126.62 399.62 0.38 938.14 3.95E+07 6.21E-01 0.684699 8.353E+03
11 125.90 125.933 125.92 398.92 -0.02 939.15 3.96E+07 6.21E-01 0.684584 1.830E+04
12 126.05 126.000 126.03 399.03 0.03 938.14 3.96E+07 6.21E-01 0.684602 1.653E+04
Metodo McAdams
To=TvTw
Caudal Tv Tw Tf Tf T Densidad uf K ho
(LPM) C C C K K Kg/m^3 J/Kg Kg/m.s W/m.K W/m^2.K
8 126.300 125.167 125.450 398.450 1.133 939.148 3.96E+07 6.21E-04 6.85E-01 3.58E+04
9 127.450 126.633 126.838 399.838 0.817 937.486 3.95E+07 6.21E-04 6.85E-01 3.89E+04
+0.0210 127.000 126.233 126.425 399.425 0.767 938.143 3.95E+07 6.21E-04 6.85E-01 3.95E+04
11 125.900 125.933 125.925 398.925 0.033 939.148 3.96E+07 6.21E-04 6.85E-01 8.66E+04
12 126.050 126.000 126.013 399.013 0.050 938.143 3.96E+07 6.21E-04 6.85E-01 7.82E+04
b) Calcular el coeficiente pelicular del agua hi utilizando las ecuaciones 20,21, 22, 23, 24 y 26
Dimensiones
Di = 21 mm
L= 3.28 M
0.00034404
A transv 5 m2
Cauda
l caudal V T in Tout b k Densidad Cp
(LPM) M3/seg (m/s) C C Tb C Tb K Kg/m3
8 1.33E-04 0.39 23.7 51.8 37.75 310.75 2.39E-04 0.6230 992.06 7.525E+04
9 1.50E-04 0.44 23.8 48.8 36.3 309.30 2.39E-04 0.6211 992.85 7.526E+04
10 1.67E-04 0.48 23.8 47.3 35.55 308.55 2.39E-04 0.6202 992.164 7.526E+04
11 1.83E-04 0.53 23.8 43.5 33.65 306.65 2.39E-04 0.6178 992.243 7.527E+04
12 2.00E-04 0.58 23.5 43.7 33.6 306.60 2.39E-04 0.6177 992.322 7.528E+04
Caud
al
L/D
caudal
(LPM) M3/seg Re Pr
3.37E+0 28.8 156.712
8 1.33E-04 4 7 9
3.79E+0 28.9 156.712
9 1.50E-04 4 6 9
4.21E+0 29.0 156.712
10 1.67E-04 4 0 9
4.63E+0 29.1 156.712
11 1.83E-04 4 2 9
5.05E+0 29.1 156.712
12 2.00E-04 4 3 9
0.8 n
Nu=0 .023Nre Npr
0.8
1057[ 1.352+ 0.02t ]v
h=
d 0.2
caudal M3/seg hi
1.3333E-04 2.261E+03
1.5000E-04 2.450E+03
1.6667E-04 2.646E+03
1.8333E-04 2.803E+03
2.0000E-04 3.004E+03
Ec.22 De Colburn
2
h
j= ( G .Cp )
( Pr )3 =0.023 0.2
h
St=
G .Cp
Tfilm=(Tb-TW)/2
caudal M3/seg j St h
1.33E-04 2.86E-03 3.04E-04 8.79E+03
1.50E-04 2.79E-03 2.96E-04 9.65E+03
1 0.14
u
Nu=0.027 Pr ( b )
0.8 3
uw
0 .24 1
a=0 .88 b= +0 . 5exp ( 0 . 6Npr w )
4+ Npr w 3
6
caudal M3/seg a
10000<
b
Nre< 10
Nusselt h
1.33E-04 0.87270 0.3333333483 4.16E+02 1.24E+04
1.50E-04 0.87272 0.3333333476 4.61E+02 1.37E+04
1.67E-04 0.87273 0.3333333472 5.05E+02 1.50E+04
1.83E-04 0.87275 0.3333333462 5.50E+02 1.62E+04
2.00E-04 0.87276 0.3333333462 5.93E+02 1.75E+04
f
( Nre1000 )Npr
Nu=
2
1+ [ ( ) ] (
3 D
L
2
b
w
0. 14
)
1+12 . 7
f (3
2
Npr 2 1 )
2
f =0 . 25( 1 . 82Log ( Nre ) 1. 64 )
UNIVERSIDAD NACIONAL DE INGENIERIA
2300< Nre< 106 0 .5Npr2000 0<D/ L<1
14
LABORATORIO DE OPERACIONES UNITARIAS I
caudal M3/seg d/L f Nusselt h
1.33E-04 0.0063811 5.748E-03 402.9626 1.20E+04
1.50E-04 0.0063811 5.588E-03 448.4226 1.33E+04
1.67E-04 0.0063811 5.452E-03 492.5224 1.46E+04
1.83E-04 0.0063811 5.333E-03 536.9536 1.58E+04
2.00E-04 0.0063811 5.227E-03 580.1879 1.71E+04
I.
caudal
M3/seg Re jH
1.33E-04 3.37E+04 110
1.50E-04 3.79E+04 122
1.67E-04 4.21E+04 130
1.83E-04 4.63E+04 133
2.00E-04 5.05E+04 140
caudal
jH
M3/seg Re hi
1.33E-04 3.37E+04 110 1.00E+04
1.50E-04 3.79E+04 122 1.11E+04
1.67E-04 4.21E+04 130 1.18E+04
1.83E-04 4.63E+04 133 1.20E+04
2.00E-04 5.05E+04 140 1.27E+04
II. CONCLUSIONES
Existe perdidas del calor al ambiente por secciones no aisladas del equipo en un
rango de porcen
En la experiencia no se cumple las condiciones para utilizar la deduccin de la grfica
de Wilson, de mantener las temperaturas promedio del condensado y el agua.
taje de 7- 47%.
El coeficiente de transferencia global no aumenta considerablemente a medida
que aumenta el caudal del fluido frio.
La resistencia que ofrece el condensado es mucho mayor que la resistencia que
ofrece el lado lquido.
III. CUESTIONARIO
1) Por el mtodo del anlisis dimensional deducir la ecuacin (15b) para el caso de
la conveccin forzada por el interior de un tubo horizontal.
Nu=f ( , Pr )
H
hi =
q L2T ,
como no se conoce si todos los trminos de energa sern expresados mecnica o
trmicamente por las dimensiones de variables, se deber incluir la constante
adimensional
ML2
KH =
Hq 2 .
hi, , u, , cP , D, k , m , K H
hi = a b
ua cP d
De mg
kf KH i
a b d f g i
L M H e H M M L2
hi = a
3 ( L )
q L M
T q
q H
L T L q2
H
hi =
q L2T
H , 1= d + f -i
L, - 2 = a - 3
b +e - f - g + 2
i
M , 0 = b-d + g +i
T , - 1 = -a - f - g - 2
i
Resolviendo simultneamente
a 1- f
hi D D m
u cP
=a
k m k
( Re )
( Pr )
a 1- f
lo que es equivalente a : Nu = a
EL MATERIAL MS ADECUADO:
En general, todos los materiales ofrecen resistencia al paso del calor, es decir, son
aislantes trmicos. La diferencia es que de los que se trata tienen una resistencia
muy grande, de modo, que espesores pequeos de material presentan una
resistencia suficiente al uso que quiere drsele.
Su criterio para ser escogido, debe ser por su uso, costo, duracin e impacto
ambiental, un material cuyas mejores propiedades aislantes es:
CELULOSA
Las fibras de vidrio son buenos aislantes trmicos debido a su alto ndice de rea
superficial en relacin al peso. Sin embargo, un rea superficial incrementada la
Las trampas de vapor son un tipo de vlvula automtica que filtra el condensado
(es decir vapor condensado) y gases no condensables. En la industria, el vapor es
regularmente usado para calentamiento o como fuerza motriz para un poder
mecnico. Las trampas de vapor son usadas en tales aplicaciones para asegurar
que no se desperdicie el vapor.
IV. BIBLIOGRAFIA
Alan Foust,Principios De Operaciones Unitarias.Segunda Edicion.pag334-385
http://www.tlv.com/global/LA/steam-theory/steam-heating-mechanism.html
http://www.tlv.com/global/LA/products/080000.html
http://0grados.com/los-gases-no-condensables/
V. PROBLEMAS
15.7 (FOUST) una corriente de nitrgeno a 30lb/plg 2 manomtrica fluye por el anular
de un intercambiador de calor de doble tubo formado por un tubo de acero ced.40 de
2plg y un tubo de cobre 16BWG de 1plg.el flujo del gas es de 6500pies 3 /h, medido a
60 0 F y 760mmHg.el agua fluye en el tubo a una velocidad de 2pies/s entrando a 50 0
F .se va a enfriar el nitrgeno de 250 a 60 0 F. Qu longitud debe tener el
intercambiador?