PRCTICA # 3
COMPRESOR DE DOS ETAPAS
DATOS GENERALES
Perodo: 2017-A
Grupo de laboratorio: GR#12
Nombre: Maldonado Jonathan Cahuasqui Juan
Fecha de realizacin: 24/05/2017
HOJA DE DATOS
1.- Datos tomados para el aire
AIRE
INTER- COMP POST-
P P. COMP baja Hmi Hmi
ENFRIAD alta ENFRIADOR
No. interm tanque caja tobera
Ts Te Ts Te Ts Te
[psig] [psig] Te [C] Ts [C] [pulg] [pulg]
[C] [C] [C] [C] [C] [C]
1 25 69 24 93 26 65 25 0.7 0.8
2 20 69.5 23 86 27 85 28 0.6 0.6
3 34 68.5 23 115 26 67 29 0.8 0.8
4
AGUA DE ENFRIAMIENTO
COMP. BAJA INTERENFRIADOR COMP. ALTA POSTENFRIADOR
No. Te Ts Hcr Te Ts Hcr Te Ts Hcr Te Ts Hcr
[C] [C] [pulg] [C] [C] [pulg] [C] [C] [pulg] [C] [C] [pulg]
1 21 36 5 21 23 5.63 21 25 5 21 27 2.88
2 21 36 5 21 24 5.63 21 27 5 21 30 3
3 20 41 5 20 25 5.63 20 25 5 20 29 3
4
MOTORES DC
COMPRESOR BAJA COMPRESOR ALTA
No. F COMP MOTOR V A F COMP MOTOR V A
[lbf] [rpm] [rpm] [V] [A] [lbf] [rpm] [rpm] [V] [A]
1 10.1 389 1167 180 15 5.63 370.5 1110 170 7.5
2 8.8 348 1044 160 13 5.75 432.8 1298.4 190 8
3 11.6 442 1326 195 17 5.13 310 930 140 7
4
INFORME
Pgina 1 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
2. Consulte y enliste las actividades bsicas que se deben realizar como parte del
mantenimiento de los compresores de aire. (1 pto)
A. Hacer un inventario de los compresores instalados:
1. Cantidad, localizacin en planta, tipo de compresor.
2. Determinar el ciclo de trabajo, tiempo cargando vs. tiempo descargando de cada
compresor.
B. Determinar la disponibilidad de capacidad de aire en reserva en cada rea
deservicio:
1. Evaluar los efectos de una interrupcin de la operacin en cada rea para predecir el
aspecto de crisis de un compresor que est temporalmente fuera de servicio.
2. A partir de estos efectos, se podr establecer reas crticas y asignar prioridades en los
programas de mantenimiento.
C. Determinar requerimientos diarios normales de cada unidad:
1. Aceite.
2. Chequeos visuales y audibles.
3. Establecer hoja de registro de rutina para ser llevada por las personas responsables de
la mquina.
4. Revisar las hojas conjuntamente con el personal.
5. Planear con anticipacin como resultado de estas de registro: piezas en existencia,
reemplazamiento de piezas, chequeos peridicos, etc.
Pm= 2 P 1P 2
Dnde:
P1: Presin atmosfrica 10,44psia
P2: Presin de salida en el tanque (70psig+10,44psi)=80,44psia
2
Pm= 10,4480,44=28,98 psia=18,54 psig
Pgina 2 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
5. Explique brevemente el mtodo que empleo para calcular el rea del diagrama
indicado. Y tabule las reas obtenidas. (2 ptos)
Para el clculo de las reas se sac una fotocopia de los diagramas directo en hojas
milimetradas para conservar la escala y poder contar los cuadrados de 1mm por 1mm
dentro de las grficas.
6. Calcule la presin media indicada para cada una de las mediciones realizadas.
(1 pto)
Compresor de alta:
mm2( 1 pulg )2 psi
449.5 2
120
AK ( 25.4 mm ) pulg
Pindicaca 1= = =46.1 psi
L cm1 pulg
4.6
2.54 cm
Pgina 3 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
2 2
mm ( 1 pulg ) psi
423.5 2
120
( 25.4 mm ) pulg
Pindicaca 2= =45.4 psi
cm1 pulg
4.4
2.54 cm
Compresor de baja:
mm 2( 1 pulg )2 psi
88.5 2
72
( 25.4 mm ) pulg
Pindicaca 2= =6 psi
cm1 pulg
4.2
2.54 cm
2 2
mm (1 pulg ) psi
124 2
72
( 25.4 mm ) pulg
Pi ndicaca3= =8.7 psi
cm1 pulg
4.3
2.54 cm
Pgina 4 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
3 1.229 0,81
Ejemplo de clculo
n1
TS P
( )
= S
T E PE
n
donde,
T S : Temperatura absoluta a la salida del compresor
TE : Temperatura absoluta a la entrada del compresor
PS : Presin absoluta a la salida del compresor
PE : Presin absoluta a la entrada del compresor
n1
366 35,44
= (
297 10.44 ) n
n=1.206
donde,
V
v =1 M
VD [( ) ]
Ps 1n
Pe
1
[( ]
3 1
3.029 [ ] 35.44 [ psia ]
v =1
100.53 [ ] 10.44 [ psia ]
3 ) 1.206
1 v =0. 8986
9. Calcule las entalpas de entrada y salida del aire a cada uno de los compresores.
Y tabule los valores obtenidos. (2 ptos)
Pgina 5 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
Nota: La entalpas del aire puede calcular asumiendo aire como gas ideal, usando la
tabla A-17E del libro de Termodinmica de Cengel.
Pe =VI
V =Voltaje ( V )
I =Amperaje ( A)
1 [ HP ]
Pe =180 [ V ]15 [ A ] =2700 [ W ] =3,62 [ HP ]
745.7 [ W ]
Pe ,m=T
2
= rpm
60
T =F r
2
Pe ,m=F r rpm
60
1 [ pie ] 1 [ HP ]
Pe ,m=10,1 [ lbf ] 13 [ plg ] 1167
[rev] 1 [min] 2 rad
[min] 1[rev ] 60 s
[ ]
12 [ plg ]
550[ lbf pie
s ]
P e , m=2,43 Hp
Pgina 6 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
Pe ,c =0.98 P e, m
Pe ,c =0.98 2,43 [ HP ]
Pe ,c =2.38 [ HP ]
Pi=Pmi V d N c
Pu=PiQ w
Qw =mw C p T
H 0.496638
mw = CR
99.1094
donde,
Qw :Energa perdida en los intercambiadores (HP)
mw : Flujo de masa (lbm/s)
( 4.5 [] )0.496638
mw = =0.0213[lbm/s ]
99.1094
3600 [ ]
s
hora
Qw =0.0213 [ ] [ ] [ ](
lbm
s
1
BTU
lbmR
1.8
R
K
2525 ) [ K ] =0
BTU
s
[ ] =0
2544.43 [
BTU
hora
/HP ]
Pu=0.82 [ HP ]0,12 [ HP ] Pu=0.7 [HP ]
Pgina 7 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
H CR0,496638 lbm
mw = [ ]
99,1094 s
0,496638
(4.625)
mw =
99,1094
lbm
mw =0,02158 [ ]
s
Q c =m w C P T
Qc =0,02158 [ ] lbm
s
x 1910
J
[
lbmK ]
x ( 2321 ) [K ] x
1[HP ]
745,7[w ]
Qc = 0,11 Hp
Flujo msico en la caja de aire (kg/s) (Use flujo msico obtenido en la caja de aire)
mc =3,079 d c 2
he H
T
1 [ kg ]
mc =0.8715
[ ]
lbm
x x
1[ min]
min 2,2 [ lbm ] 60 [s]
kg
mc =0,00660[ ]
s
Qa= mc ( h 2h1 )
Qa=0,8715 [ ]
lbm
min
Qa=2.05 x 102 HP
Pgina 8 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
FLUJOS DE ENERGA
P mw mw
Qc Qa mc mt Qw
intermedia Compresor [lbm/s] [lbm/s]
[HP] [HP] [lbm/min] [lbm/min] [HP]
[psig] compres intercam
DE BAJA 191 0.011 0.61 0.1 0,02
25 0.803 0.793
DE ALTA 50,93 0.013 0.3 0.4 0,02
DE BAJA 191 0.011 0.83 0.13 0,02
20 0.866 0.911
DE ALTA 76,4 0.0123 0.21 0.4 0,02
267,4
DE BAJA 0.011 0.5 0.13 0,02
34 1 0.731 0.721
DE ALTA 63,67 0.0123 0.34 0.44 0,02
Nota: Realice el clculo de Qa con mc, ya que mc debera ser igual a mt, pero mc es
una medida que fluctuaba menos, puesto que la vlvula de la tobera se estaba
regulando continuamente.
Realice las conversiones de unidades necesarias para obtener las unidades deseadas
EFICIENCIA
P intermedia [psig] Compresor ne nt nmec nf nT nTT
DE BAJA 0.155 0.977 3.3 0.93 0.48
25 1.3
DE ALTA 0.239 0.979 4.37 0.81 0.82
DE BAJA 0.173 0.969 1.77 0.88 0.26
20 1.25
DE ALTA 0.237 0.966 5.54 0.78 0.99
DE BAJA 0.139 0.964 7.21 0.93 0.9
34 1.93
DE ALTA 0.264 0.98 4.88 0.82 1.03
Nota: La eficiencia nf puede asumirse como la relacin entre Pu/Pi.
Pgina 9 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
12. Realice un diagrama Sankey para una de las condiciones de funcionamiento del
equipo, realice los diagramas a escala. (Recuerde considera que hay dos
compresores, cada uno con su propia alimentacin de energa elctrica) (4 ptos)
PREGUNTAS DE ANLISIS
13. Comparando la presin intermedia ideal calculada (pregunta 11) con los datos de
eficiencia obtenidos en las distintas condiciones de operacin de la prctica
(para distintas presiones intermedias). Explique si existe concordancia y de no ser
as a que se debe.
(2 ptos)
La eficiencia debera aumentar mientras ms se acerca la presin intermedia a la
calculada lo cual no sucede, esto se debe a que el clculo de eficiencias presenta
errores
14. Existe una diferencia entre el flujo de aire medido en la caja de aire y en la
tobera? De ser as, explique a que cree que se debe.
(2 ptos)
Existe una variacin de mximo ocho centsimas y un mnimo de dos centsimas, la
diferencia puede ser por las diversas prdidas que se tiene como por ejemplo la
condensacin del agua dentro del sistema, esto afecta directamente al flujo msico en
la salida
15. Compare los valores de Qa y Pi, cul de ellos es mayor? es eso lo que se
esperaba? Explique. (2 ptos)
El Valor de Pi es mayor al de Qa esto se debe a que la potencia entregada al aire es
menor potencia indicada teoricamente
16. Calcule el calor perdido por el aire en los intercambiadores de calor, empleando
los valores de entalpa del aire (calculados en la pregunta 7). Compare los
resultados con el calor perdido en los intercambiadores calculado con el agua
(Qw=mCpT, calculado en la pregunta 9) existe una diferencia entre ellos?
Explique a que puede deberse esta diferencia. (3
ptos)
Qw [HP] Qw [HP]
Compresor
Con h aire De pregunta 9
DE BAJA 0.49 0.1
DE ALTA 0.31 0.4
DE BAJA 0.67 0.13
Pgina 10 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
CONCLUSIONES
(3 ptos)
ESTUDIANTE 1 Jonathan Maldonado
Al aumentar el flujo de agua de enfriamiento el proceso tiende a ser isotrmico
al disminuirlo el proceso tiende a ser isoentropico.
El equipo del laboratorio corresponde a un proceso politrpico, tanto en el
compresor de alta como de baja.
Las relaciones de compresin en todas las etapas presentan valor igual, se
logra un consumo de potencia mnima
BIBLIOGRAFA
http://es.wikihow.com/elegir-un-compresor-de-aire
http://www.typrefrigeracion.com.mx/index.php?
page=shop.product_details&flypage=&product_id=596&category_id=341&optio
n=com_virtuemart&Itemid=11
Pgina 11 de 12
ESCUELA POLITCNICA NACIONAL
FACULTAD DE INGENIERA MECNICA
LABORATORIO DE TERMODINMICA
DISPOSICIONES GENERALES
FORMATO
Conservar el formato (tamao y tipo de letra y el espaciamiento) de este documento
Letra: Arial 11
Interlineado: 1,15
Respuestas SIN negritas
CONTENIDO
- Datos Generales
- Datos medidos
- Informe
Dar respuestas concretas y breves.
De preferencia usar definiciones con sus propias palabras
Referenciar correctamente usando bibliografa con normas APA
- Anlisis de resultados
Ser objetivos
No son conclusiones o recomendaciones
Es individual
- Conclusiones
Dar respuestas concretas y breves.
Es individual.
- Bibliografa
ENVIAR A:
- Correo: termodinamica3epn@gmail.com
- Asunto: LT_Compresor_GR# (ejemplo: LT_Compresor_GR1)
- Archivo:LT_Compresor_Apellido1_Apellido2 (ejemplo: LT_Compresor_Acosta_Mora)
Pgina 12 de 12