Anda di halaman 1dari 1

9/6/2017 Interior Tool Print

Visual - Interior Tool


Design Information Friday, June 09, 2017
Your Name
Project Name
Company Name
Project Description
Your Phone
Your Email

Calculation Results
Illuminance 51fc
Power
13.18W/meters
Density
Quantity 18
Spacing Results
3.05 x
Spacing
2.44meters
Arrangement 6 x 3
Offset X 2.63meters
Offset Y 0.95meters
Room Summary
Length 21.03meters
Width 7.94meters
Height 3meters
Workplane 1meters
Reflectances
Ceiling 50%
Walls 50%
Floor 20%

EATON - METALUX (FORMER COOPER LIGHTING) [B] -2GR5-254T5A125-UNV-EBT1


Light Loss Factor 0.7 Lamp Lumens 4400 Wattage 122.3 Watts
Suspension Length 0 meters Lamp Quantity 2 CU 0.83

These lighting calculation results are for general informational purposes only and are provided without warranty as to accuracy, completeness, reliability or
otherwise. Results are based on user provided data and data provided from publicly available sources; actual field conditions may affect calculated output. Visit
www.Visual-3D.com .

https://www.visual-3d.com/tools/interior/Print.aspx?SessionID=7549893 1/1