ULTRASONIC DOPPLER FLOWMETERS

Flow Reference Section


INTRODUCTION pulses which are processed to provide Clean Liquids
an analog indication and a voltage or As noted, the basic ultrasonic Doppler
The Ultrasonic doppler flowmeter current output signal. Additionally, the
incorporates a technology offering flowmeter requires that the liquid to be
pulses are scaled and totalized to measured contain a minimum of at
an increased range of applications. provide flow quantity.
Because of its non-invasive nature, least 100 PPM of suspended solids or
no pressure drop is created, and this The transmitter frequency power bubbles at least 100 microns or larger
type of flowmeter can be used to levels and transducer configuration in size. The transducer frequency for
measure the flow of fluids and slurries are selected to accommodate a wide these requirements is 1 megahertz.
which ordinarily cause damage to variety of liquids, pipe sizes, Lower frequencies require more PPM
conventional sensors. percentage of solids, and pipe liners. and a larger micron size. Until
recently, 100 PPM of suspended
The basic principle of operation The transmitter also incorporates solids or bubbles of at least 100
employs the frequency shift (Doppler circuitry which allows adjustment of microns or larger, constituted the
Effect) of an ultrasonic signal when it the signal threshold, permitting cleanest measurable application.
is reflected by suspended particles or elimination of undesirable ambient The solution for clean liquid
gas bubbles (discontinuities) in noises (both mechanical and applications is the FDT family of
motion. This metering technique electrical). As a result, instrumentation Transit Time Ultrasonic flow meters
utilizes the physical phenomenon of is possible in a variety of locations FDT-30, FDT-80 and FDT100
a sound wave that changes frequency subject to high levels of sonic, products. In these designs, the time
when it is reflected by moving mechanical, and electrical noise. of flight of the ultrasonic signal is
discontinuities in a flowing liquid. measured between two transducers-
Ultrasonic sound is transmitted into ACCURACY one upstream and one downstream.
a pipe with flowing liquids, and the Without Field Calibration The difference in elapsed time going
discontinuities reflect the ultrasonic with or against the flow determines
The accuracy of a flowmeter operating the fluid velocity. Transit time flow
wave with a slightly different on the Doppler principle is mainly a
frequency that is directly proportional meters feature the world’s most
characteristic of flow velocity profile advanced non-invasive flow
to the rate of flow of the liquid (Figure integration by the ultrasonic wave.
1). Current technology requires that measurement technology—providing
The ability to do this is basically a a measuring system with unsurpassed
the liquid contain at least 100 parts function of: percentage of sound
per million (PPM) of 100 micron or accuracy, versatility, ease of
reflectors (solids and bubbles), their installation and dependability.
larger suspended particles or bubbles. size, variation and distribution, the line Designed primarily for clean liquids,
A typical system incorporates a size, and the flowmeter’s design the flow meter operates reliably with
transmitter/indicator/totalizer and features. Therefore, it is unrealistic to small amounts of suspended solids or
a transducer. The transducer is state a general accuracy without aeration. Transit time flow meters are
mounted on the exterior of the pipe. knowing the full application details designed for long- or short-term
It is driven by a high frequency and the transducer selection. measurement flow surveys on full-
oscillator in the transmitter through an With Field Calibration pipe liquid systems and are ideal for
interconnecting cable. The transducer verifying calibration of permanently
generates an ultrasonic signal which it The accuracy of this method with a mounted flow meters of all types.
transmits through the wall of the pipe field flow calibration can be as high as
into the flowing liquid. The transmitter ±1% plus the accuracy of the flow When the flow is zero, the time for the
measures the difference between its calibration on the actual application at signal T1 to get to T2 is the same as
output and input frequencies and given conditions. that required to get from T2 to T1.
converts this difference into electronic When there is flow, the effect is to
boost the speed of the signal in the
downstream direction, while
decreasing it in the upstream
direction. The flowing velocity (Vf)
can be determined by the following
equation:
Vf = Kdt/TL
where K is a calibration factor for the
volume and time units used, dt is the
time differential between upstream
and downstream transit times, and TL
is the zero-flow transit time.
Transit Time Ultrasonic flow meters
are specifically designed to work in
clean and ultra-clean liquid
applications. Bridging the gap is the
FD-7000 enhanced ultrasonic flow
meter. Examples of liquids that fall
into the gap between Doppler and
Transit Time technologies include:
ground water, gray water, carbonated
beverages, waste or return activated
Figure 1: The Ultrasonic Doppler Flow Sensor sludge, mining slurries and filter
backwash.
E-3
One Omega Drive | Stamford, CT 06907 | 1-888-TC-OMEGA (1-888-826-6342) | info@omega.com

www.omega.com
UNITED KINGDOM
www. omega.co.uk
Manchester, England
0800-488-488

UNITED STATES FRANCE


www.omega.com www.omega.fr
1-800-TC-OMEGA Guyancourt, France
Stamford, CT. 088-466-342

CANADA CZECH REPUBLIC


www.omega.ca www.omegaeng.cz
Laval(Quebec) Karviná, Czech Republic
1-800-TC-OMEGA 596-311-899

GERMANY BENELUX
www.omega.de www.omega.nl
Deckenpfronn, Germany Amstelveen, NL
0800-8266342 0800-099-33-44

More than 100,000 Products Available!


Temperature Data Acquisition
Calibrators, Connectors, General Test and Measurement Auto-Dialers and Alarm Monitoring Systems,
Instruments, Glass Bulb Thermometers, Handheld Instruments Communication Products and Converters, Data
for Temperature Measurement, Ice Point References, Acquisition and Analysis Software, Data Loggers
Indicating Labels, Crayons, Cements and Lacquers, Infrared Plug-in Cards, Signal Conditioners, USB, RS232, RS485
Temperature Measurement Instruments, Recorders Relative and Parallel Port Data Acquisition Systems, Wireless
Humidity Measurement Instruments, RTD Probes, Elements Transmitters and Receivers
and Assemblies, Temperature & Process Meters, Timers and
Counters, Temperature and Process Controllers and Power
Pressure, Strain and Force
Switching Devices, Thermistor Elements, Probes and
Displacement Transducers, Dynamic Measurement
Assemblies,Thermocouples Thermowells and Head and Well
Force Sensors, Instrumentation for Pressure and Strain
Assemblies, Transmitters, Wire
Measurements, Load Cells, Pressure Gauges, Pressure
Flow and Level Reference Section, Pressure Switches, Pressure Transducers,
Air Velocity Indicators, Doppler Flowmeters, Level Proximity Transducers, Regulators,
Measurement, Magnetic Flowmeters, Mass Flowmeters, Strain Gages, Torque Transducers, Valves
Pitot Tubes, Pumps, Rotameters, Turbine and Paddle Wheel
Flowmeters, Ultrasonic Flowmeters, Valves, Variable Area Heaters
Flowmeters, Vortex Shedding Flowmeters Band Heaters, Cartridge Heaters, Circulation Heaters,
Comfort Heaters, Controllers, Meters and Switching
pH and Conductivity Devices, Flexible Heaters, General Test and Measurement
Conductivity Instrumentation, Dissolved Oxygen Instruments, Heater Hook-up Wire, Heating Cable
Instrumentation, Environmental Instrumentation, pH Systems, Immersion Heaters, Process Air and Duct,
Electrodes and Instruments, Water and Soil Analysis Heaters, Radiant Heaters, Strip Heaters, Tubular Heaters
Instrumentation

click here to go to the omega.com home page


EPG05

Anda mungkin juga menyukai