Anda di halaman 1dari 5

TECHNICAL DATA

ETERCURE 6210G
MODIFIED EPOXY CRYLATE

ETERNAL CHEMICAL CO., LTD. August 10 2005

MATERIAL SAFETY DATA SHEET

1. Identification of the substance/preparation and of the company/undertaking


Identification of the product
Product name: ETERCURE 6210G
Manufacturer supplier identification. ETERNAL CHEMICAL CO., LTD.
Address : 22,CHANG-HSIUNG RD,HOU-HSIANG VILLAGE,LU-CHUH
HSIANG,KAOSHIUNG COUNTY,TAIWAN,821
Contact for information: Mr. Ming Hsin Lu
Emergency telephone No.: 886-7-6963331 ext 547
2. Composition/information on ingredients

Ingredient Percent CAS Index No. /EC No. Molar mass Molecular formula Symbol
Epoxy Acrylate Oligomer AP 70 55818-57-0

Propoxylated Glyceryl Triacrylate AP 30 52408-84-1

3. Hazards identification
WARNING
PHYSICAL HAZARDS : Unstable(reactive)upon depletion of inhibitor
ACUTE HEALTH EFFECTS : Suspect skin sensitization hazard
Suspect slightly skin irritation hazard
Suspect slightly eye irritation hazard
Respiratory tract irritation hazard
Not expect to be a skin absorption harzard
Not expect to be an ingestion harzard
CHRONIC HEALTH EFFECTS: No data are available on the chronic health hazards of this mixture.

The information contained herein is correct to the best of our knowledge. The recommendations or suggestions contained in this bulletin are made 1
without guarantee or representation as to results. We suggest that you evaluate these recommendations and suggestions in your own laboratory prior to
use. Our responsibility for claims arising from breach of warranty, negligence, or otherwise is limited to the purchase price of the material.
TECHNICAL DATA

ETERCURE 6210G
MODIFIED EPOXY CRYLATE

ETERNAL CHEMICAL CO., LTD. August 10 2005

4. First aid measures


After inhalation : If overcome by exposure, remove victim to fresh air immediately. Give oxygen or artificial
respiration as needed. Obtain emergency medical attention. Prompt action is essential.
After skin contact: Immediately remove contaminated clothing . Wash skin thoroughly with mild soap/water. Flush
w/lukewarm water for 15 minutes. If sticky, use waterless cleaner first. Seek medical attention if ill
effect or irritation develops.
After eye contact : In case of eye contact , immediately rinse with clean water for 20-30 minutes. Retract eyelids often .
Obtain emergency medical attention.
After swallowing : If large quantity swallowed, give lukewarm water (pint) if victim completely conscious/alert. Do not
induce vomiting/risk of damage to lungs exceeds poisoning risk. Obtain emergency medical
attention.
5. Fire-fighting measures
Suitable extinguishing media water spray, water fog, foam, carbon dioxide or dry chemical.
Special risksHigh temperatures.inhibitor depletion, accidental impurities, or exposure to radiation or oxidizers may
cause spontaneous polymerizing reaction generating heat / pressure. Closed containers may rupture or
explode during runaway polymerization.
Special protective equipment for fire fightingWear positive-pressure self-contained breathing apparatus(SCBA) and
protective fire fighting clothing.
Other informationDense smoke is produced when product burns. Violent steam generation or eruption may occur upon
application of direct water stream. Vapors are heavier than air and may travel a long distance and
accumulate in low areas.
6. Accidental release measures
Person-related precautionary measuresDo not breathe vapors. Eliminate all sources of ignition in Vicinity of spill or
released Vapor to avoid fire or explosion. Check area with explosion meter before re-entering area.
Environmental-Protection measuresevacuate upwind of spills and contain with dike.
Procedures for cleaning/absorptionPump with explosion-proof equipment. Remove residual with hot soapy water.
Solvents are not recommended for cleanup unless the recommended.
7. Handling and storage
HandlingUnless inhibited, product can polymerize, raising temperature and pressure, possibly rupturing container.
Check inhibitor content often , adding to bulk liquid if needed. Do not blanket or mix with oxygen-free gas
as it renders inhibitor ineffective. Do not store at /below 32F-- inhibitor can separate as a solid. If frozen,
warm and remix material gently(<90F). Prevent moisture contact. Product may be heated to facilitate
handling. Heat product container slowly for not more than 24 hours. Convection ovens or warm water baths
The information contained herein is correct to the best of our knowledge. The recommendations or suggestions contained in this bulletin are made 2
without guarantee or representation as to results. We suggest that you evaluate these recommendations and suggestions in your own laboratory prior to
use. Our responsibility for claims arising from breach of warranty, negligence, or otherwise is limited to the purchase price of the material.
TECHNICAL DATA

ETERCURE 6210G
MODIFIED EPOXY CRYLATE

ETERNAL CHEMICAL CO., LTD. August 10 2005

(preferred due to more efficient heat transfer)are recommeded for heating. Do not use localized heat
sources such as drum heater or steam . An air space, preferably an air bubble flow, should be provided for
at all times during heating.
Storage Store in tightly closed. properly vented containers away form: heat. sparks. open flame. strong oxidizers,
radiation, and other initiators. Prevent contamination by foreign materials. Use only non-sparking tools and
limit storage time.
8. Exposure controls/personal protection
Specific control parameter :
Personal protective equipment :
Respiratory protection : If this material is handled at elevated temperature or under mist forming conditions
NIOSH/MSHA approved respiratory protection equipment should be used.
Eye protection : Eye protection such as chemical splash goggles and /or face shield must be worn when
possibility exists for eye contact due to splashing or spraying liquid, airborne particles, or
vapor. Contact lenses should not be worn.
Hand protection : Chemical-resistant gloves should be wore when handing this product.
Industrial hygien : Supply safety shower and eye bath. Wash thoroughly after handling.
9. Physical and chemical properties

Form Explosion LimitsLower - Upper -


ColorColorless liquid Vapor pressureN / DA
Odorlow odor Relative vapor density-
pH valueAP 6.8 to 7.2 DensityAP 1.161 at 25C/77F
Viscosity dynamicAP 25000 cps at 25C/77F Bulk density-
Melting temperature- Solubility in Water - Acetone -
Boiling temperatureN / DA Thermal decompositionN / DA
Ignition temperature- Evaporation enthalpyN / DA
Flash point100

The information contained herein is correct to the best of our knowledge. The recommendations or suggestions contained in this bulletin are made 3
without guarantee or representation as to results. We suggest that you evaluate these recommendations and suggestions in your own laboratory prior to
use. Our responsibility for claims arising from breach of warranty, negligence, or otherwise is limited to the purchase price of the material.
TECHNICAL DATA

ETERCURE 6210G
MODIFIED EPOXY CRYLATE

ETERNAL CHEMICAL CO., LTD. August 10 2005

10. Stability and reactivity


Conditions to be avoided : High temperatures, localized heat sources (ie, drum or band heaters),oxidizing conditions,
freezing conditions, direct sunlight, ultraviolet radiation, inert gas blanketing.
Substances to be avoided : Strong oxidizers, strong reducers, free radical initiators, inert gases , oxygen scavengers.
Hazardous decomposition products : Acrid smoke-fumes/carbon monoxide/carbon dioxide and perhaps other toxic
vapors may be released during a fire involving this product.
Further information : -
11. Toxicological information
Acute toxicity:
LD 50(oral, rat) : -
LD 50(dermal, rabbit) : -
Further toxicological information :
After inhalation : Harmful if inhaled. Can cause severe irritation and burns of nose, throat, and respiratory tract.
After Skin contact : Can cause severe irritation, possible skin burns. May be absorbed through the skin.
After eye contact : Eye irritant. It may produce corrosive effects.
After swallowing: Toxic! May cause burns, nausea, severe gastroenteritis and vomiting, shock and convulsions. May
cause renal damage, as evidenced by bloody urine.
Further data : to the best of our knowledge, the chemical, physical, and toxicological properties have not been
thoroughly investigated.
12. Ecological information
Eco-toxicological Information: No data at this time
Do not allow to escape into waters, wastewater or soil
13. Disposal considerations
Product Residues and spilled material may be hazardous waste due to potential for internal heat generation. Disposal
must be in accordance with applicable federal, state ,or local regulations.
PackagingThe container for this product can present explosion or fire hazards ,even when emptied. To avoid risk of
injury, do not cut , puncture, or weld on or near this container. Since the emptied containers retain product
residue, follow label warnings even after container is emptied.
14. Transport information
International transport regulations : Not subject to regulation.
UN-No. : -
Local transport regulations : -

The information contained herein is correct to the best of our knowledge. The recommendations or suggestions contained in this bulletin are made 4
without guarantee or representation as to results. We suggest that you evaluate these recommendations and suggestions in your own laboratory prior to
use. Our responsibility for claims arising from breach of warranty, negligence, or otherwise is limited to the purchase price of the material.
TECHNICAL DATA

ETERCURE 6210G
MODIFIED EPOXY CRYLATE

ETERNAL CHEMICAL CO., LTD. August 10 2005

Special transport method / further data : contact Eternal Chemical Company for transportation information.
15. Regulatory information : -
-
16. Other information
Make people : Professional
post : R&D Chemist
Name(sign) : Mr. Ming Hsin Lu
Make unit : Name : SM technical dept. of SC devision
Phone : 886-7-6963331 ext 547
Address : 22,CHANG-HSIUNG RD,HOU-HSIANG VILLAGE,LU-CHUH HSIANG,KAOSHIUNG
COUNTY,TAIWAN,821
Date of issue : 2005/8/10
DISCLAIMER: While ETERNAL CHEMICAL CO., LTD. Believed that data contained herein areaccurate and derived
from qualified sources the data are not be taken as a warranty or representation for solely for your
consideration, investigation and verification. Any use of these data and information must be
determined by the user to be in accordance with applicable federal, state and local and regulations.

The information contained herein is correct to the best of our knowledge. The recommendations or suggestions contained in this bulletin are made 5
without guarantee or representation as to results. We suggest that you evaluate these recommendations and suggestions in your own laboratory prior to
use. Our responsibility for claims arising from breach of warranty, negligence, or otherwise is limited to the purchase price of the material.