Vertical Direction dVf / Mf = 3.52 >1.0 -> pilecap acts as deep beam dVf / Mf > 2.0 Mf / Vf = 125 [mm] z = 0.4(d + Mf / Vf ) for dVf / Mf >=1.0 = 150 [mm] 1.2 Mf / Vf for dVf / Mf >=2.0 As1 = Mf / ( s fy z ) = 1877 [mm2] Asmin = 0.2% x bf x tf = 1240 [mm2] As1 = max ( As1, Asmin ) = 1877 [mm2] As1 prov = = 3500 [mm2] > As1 OK [Deep Beam Model Is Applicable] [Pilecap Reinft by Deep Beam Model Is Adequate] COLUMN ONE WAY SHEAR Factored single pile load Qpr = 766 [kN] bc = 330 [mm] Pile diameter dp = 250 [mm] hc = 500 [mm] Pile edge distance ed = 500 [mm] bf = 1000 [mm] Pilecap effective depth d = 440 [mm] hf = 1750 [mm] Hor Critical Shear Line Dist from col face to pile edge dc = 250 [mm] Fraction of pile outside critical line r = 0.00 Factored shear force Vf = r x Qpr =0 [kN] bw = bf = 1000 [mm] When no transverse reinft. = 230 / (1000 + d) = 0.160 11.3.6.3 Eq (11-9) V f ' = 250 [kN] 11.3.4 Eq (11-6) c = c c bw d > Vf OK [Column One Way Shear Is Adequate]
Civil Bay Anchor Bolt Design per ACI 318-11 Crane Beam Design www.civilbay.com
3-Pile Pilecap Design Example
Civil Bay Anchor Bolt Design per ACI 318-11 Crane Beam Design www.civilbay.com Anchor Bolt Design ACI 318-11 Crane Project : Anchor Bolt Design ACI 318-11 Crane Beam Design Eng : Beam Design www.civilbay.com Jon No : Chk : www.civilbay.com Doc No : www.civilbay.com Date :