SP6 Draft
December 2010
Hierarchy and References for 2D Symbolic Representation
For Non-Parameterized Equipment Templates
EQUI GPART
TMPL SELE TMPREF DRSSET LIBY
SPREF
DRSSREF
SYTM TXTM
Note:
The smaller text in the boxes indicate significant attributes of the owning element. Attribute ORRF is a pseudo-attribute and will automatically populate.
1 of 3
12.0.SP6 Draft
December 2010
Notes:
TMPLs are stored in a Design DB.
By default, TMPLs are created/positioned at coordinates 0,0,0 and should be used as TMPL origin.
Primitives elements can be created by scratch similar to typical EQUI builds or primitives of existing
EQUIs can be moved into TMPL via Modify>Hierarchy>Include command
GPART>Tmpref; DrSSRef
2 of 3
12.0.SP6 Draft
December 2010
EQUI>Spref
General Notes:
Symbol orientation does not track EQUI orientation. However, the DESSYM attributes can be modified;
e.g. ADEG, BLNK, XYSCALE, XYPOS. DESSYM origins get placed at EQUI origins.
Symmetrical symbols are ideal for EQUIs but may not necessarily address all drawing conditions.
Unable to intelligently annotate DESSYM (e.g. dimensions, GLABs, SLABs), therefore, its best if user
creates Local Rules (RULL) to apply 2D Symbolic Representation AFTER intelligent annotation is
complete. One RRUL is required for each 2D symbol.
In addition to naming the elements based on naming conventions, see each step above in the Creation
Sequence for applicable Attributes to be set. Some attributes are set automatically upon creation.
3 of 3