Anda di halaman 1dari 2

08 - Electrical/8E - Electronic Control Modules/MODULE, Anti-Lock Brake System/Removal

REMOVAL
Labor Operations: Click to display a list of Labor Operations associated with this procedure

1. Remove the master cylinder (Refer to


05 -
Brakes/Hydraulic/Mechanical/MASTER
CYLINDER, Brake - Removal) .

2. Install prop rod on the brake pedal to


keep pressure on the brake system.

3. Remove negative battery cable from the


battery.

4. Pull up on the ABM harness connector release (1) and remove connector (2).

5. Remove brake lines (2) from


the HCU (4).
6. Remove HCU/ABM mounting
nuts and bolt (4) and remove
HCU (2) / ABM (3) as an
assembly.

CAUTION: When removing


ABM from HCU, be
sure to completely
separate the two
components
(approximately 38
mm (1.5 in.) before
removing ABM.
Otherwise,
damage to the
pressure sensor
or Pump Motor
connection may
result requiring
HCU replacement.
Do not to touch
the sensor
terminals on the
HCU side or the
contact pads on
the ABM side as
this may result in
contamination and
issues in the
future.

7. Remove the ABM from the HCU.