DWG. No. QY0910-02-00 Item No.

V-027 Code API 650



Name Value
Symbol Units

2. Rafter Calculation

Inside diameter of tank D 6700 mm

Unit weight of rafter 12.059 kg/m

Total length of rafter L 3.123 m

Tank is located Anointment plate width a 876.58 mm

Section modulus of rafter Zr 5.77E-05 m3

Allowable bending stress at designed Sd kg/m2


temperature(0.6 Sy) 1.37E+07

Size of rafter [120*53*5.5*9

Live load 122.36 kg/m2

Density of roof plate Dr 7930 kg/m3

Roof plate thickness 5.0 mm

Exteral pressure 50 kg/m2

P= Live load+(DrRoof plate thickness)+Exteral pressure 212.01 kg/m2

Ls = 2( 1 feet ) 1915 mm

Nmin= (D) / Ls 10.99

Adopted number of rafter N 12

w = ( (Pa ) / 1000 )+ Unit weight of rafter 197.90 kg/m

Sc= (wL2) / ( 8Zr) 4.18E+06 kg/m2

ScSd Ok

So,the Rafter comforms to the requirement


DWG.No. QY0910-02-00 Item No. V-027 Code API 650

Name Symbol Value Units

Roof Plate And Roof Structure Calculation

1. Roof Thickness

Constant fator B 0.5

- Roof plate thickness Corrosion allowance t 5.0 mm

Density of roof plate Dr 7930 kg/m3

Angle between roof plate and a horizontal plane 9.46

Cosine value of cos 0.9997

Inside diameter of tank D 6700 mm

Number of rafter N 12 Pcs

Allowable bending stress at designed temperature(0.6 Sa kg/m2


1.37E+07
Sy)

Live load 122.36 kg/m2

Exteral pressure 50 kg/m2

Roof plate thickness 5.0 mm

Corrosion allowance 0.0 mm

P= Live load+(DrRoof plate thickness)+Exteral pressure 212.01 kg/m2

a =(D) / (2N) 876.58 mm

b=D/(2cos) 3351.16 mm

Sb= (BPa2) / t 2 3.26E+06 kg/m2

SbSa Ok

So,the Roof Plate comforms to the requirement