Power Cable Ampacity Rating -


Installations

Installations modeling including


non-standard configurations
The CYMCAP Additional Multiple Duct Banks and Modeling one heat source or This add-on module supports
Backfills heat sink in the installation a large variety of cable
Modules offer extended arrangements for single core
The Multiple Duct Banks and Computation of the steady-
capabilities to the CYMCAP Backfills add-on module (MDB)

state ampacity or temperature
(flat formations or trefoils) and
software, allowing modeling three-core cables.
is designed to determine the Transient analysis, cyclic
more installations, steady-state ampacity of cables
loading and emergency ratings
Major features are:
installed in several neighboring
particularly non-standard duct banks and/or backfills with
are supported Modeling of a large variety of
installations. This includes installation methods: laying on
different thermal resistivity. Computation of the thermal
the floor; hanging from a wall;
the modeling of installations The module presents a unique rating of cables installed in
in ladder-type racks; or in cable
solution combining standard filled troughs
with multiple ductbanks and and non-standard calculation
trays
backfills each with different methods. The module computes Cables in Tunnels Cables and groups of cables
thermal resistivity; the the values of T4 (the external can be single-core or three-
The optional Cables in Tunnels
thermal resistance to the cable) core. Single-core cables can
calculation of the ampacity using the finite element method
module allows the user
be arranged in flat formations
to determine steady-state
and temperature of cables and then the ampacity (or
temperature and ampacity, cyclic
(vertically or horizontally) or in
operating temperature) of the trefoil
in unventilated tunnels; the cable installation is obtained
loading, emergency rating and
rating of cables in both filled transient analysis for cables Computation of the
using the IEC standardized
installed in unventilated tunnels. steady-state ampacity or
and unfilled troughs; and the solution method.
Note that only equally loaded temperature. Cyclic loading
rating of cables in one or The following capabilities are cables having the same type and using daily, weekly and yearly
highlighted: loading are considered. load factors. Computation of
more non-magnetic casings.
emergency ratings
Modeling unlimited number
of rectangular areas with
different thermal resistivity
Modeling up to three duct
banks in a single installation
Power Cable Cables in Troughs
The thermal rating of cables
are all based on field research
by independent parties and
published in scientific journals.
Modeling of any number of
casings in parallel in the same
installation
installed in unfilled or in filled
Ampacity troughs is determined using
the CYMCAP/UNF and the
Filled Troughs
Modeling of any number of
ducts inside one or more
CYMCAP/MDB modules Filled troughs are treated in casings at the same time
Rating - respectively. the CYMCAP/MDB module
as multiple backfills. Cables in
Capable of modeling any
In these modules, a trough (or filled troughs are rated in the number of circuits inside a
Additional a trench) is defined to be a long
shallow rectangular-shaped
CYMCAP software using:

casing and a duct
Circuits in ducts and in
excavation, where the walls, Finite elements method to
Modules - compute the external-to-the- casings can be multiple cables
bottom and cover are made of
cable thermal resistance T4 per phase
concrete. The cables can be
installed on the floor, hanging Several materials (including
Installations
IEC Standards procedures to
from supports on the walls non-magnetic metallic
perform efficiently ampacity
or racks. The trough can be materials) are available to
calculations
filled with a material with good model ducts and casings (PVC,
thermal properties or it can be Besides, the module offers: polyethylene, earthenware,
Installations modeling left unfilled (air filled). The heat non-magnetic metal, etc.)
Computes the temperature
transfer mechanism is different
including non-standard for filled and unfilled troughs
and steady-state unequally Sizes of ducts and casings are
loaded ampacity not limited
configurations. and therefore they are treated
independently. Facilities to move the troughs
and model asymmetrical
Unfilled Troughs troughs
Initially, the only option to rate Ability to perform cyclic
unfilled trough installations was loading rating through the use
to use the IEC standard. In this of load factors
approach the cables ratings
are calculated as for cables in Multiple Casings
free air, but the temperature
inside the trough is computed The Multiple Casings add-on
according to the IEC Standard module (MCAS) allows the user
60287-2-1. The module has to determine the steady-state
been improved significantly unequally loaded ampacity
and includes three options in and/or temperature rating
addition to the IEC standard of cables installed in one or
to model a given trough more non-magnetic casings.
installation: Slaninka Method 1, In the CYMCAP software ,
Slaninka Method 2 and Anders- a casing is defined to be a
Coates Method. large non-magnetic conduit
filled with air, inside which
With the IEC standard, thermal cables in ducts and cables
resistivities of the soil and the not in ducts can be installed.
troughs cover are ignored. With Casings can be immersed in
the Slaninka Method 1, the water, placed on the sea bed or
thermal resistivity of the troughs buried underground. No other
cover is considered. The Slaninka filling material other than air is
Method 2 considers both the considered in the casing(s) or in
thermal resistivities of the cover the duct(s).
and the soil surrounding the
trough. With the Anders-Coates The module features many
method, in addition to the modeling facilities among which
thermal resistivities of the soil the following capabilities can be
and the cover, the wind velocity highlighted:
above the trough is taken into Different burial environments
account. In all options the user are allowed: water or
can choose whether the trough underground
is exposed to sun radiation or
it is shaded. The approaches

Eaton
1000 Eaton Boulevard
Cleveland, OH 44122
United States
Eaton.com

CYME International T&D


1485 Roberval, Suite 104
St.Bruno, QC, Canada J3V 3P8
P: 450.461.3655 F: 450.461.0966
P: 800.361.3627 (Canada/USA)
CymeInfo@eaton.com
www.eaton.com/cyme
Follow us on social media to get the
2015 Eaton All Rights Reserved Eaton is a registered trademark. latest product and support information.
Printed in Canada
Publication No. BR 917 030 EN All other trademarks are property
November 2014 of their respective owners.

Anda mungkin juga menyukai