Anda di halaman 1dari 2

CONCRETE STAIRS

T
W R Enter Riser Height RH (M) 0.19 M
Enter Tread Run TR (M) 0.25 M
R
H Enter Stair Width W (M) 1.25 M
Enter # of Steps N 10.00 Steps
Enter Stringer Thickness TS (M) 0.28 M

0.30 1.08 1.38

T TOTAL VOLUME OF CONCRETE: 1.38 CU.M.


S
ReinforcementSTAIRS
Enter Riser Height RH (M) 0.19 M
Enter Tread Run TR (M) 0.25 M
W T
R Enter Stair Width W (M) 1.25 M
R Enter # of Steps N 10.00 Steps
H
Enter Stringer Thickness TS (M) 0.28 M
0.30 0.31 0.61
Enter Spacing (M)
T
S 0.15
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.15 16
Enter Stringer Lateral Bar diameter (mm)
16
Enter Spacing (M)
0.15
Enter Spacing (M) Enter Steps Lateral Bar diameter (mm)
0.15 10
Enter Stringer Horizontal Bar diameter (mm)
10
Number of 16 mm Lateral Bars required @ Steps PCS @ 6M 10.00 PCS
Number of 10 mm Horizontal Bars required @ Steps PCS @ 6M 7.00 PCS
Number of 16 mm Lateral Bars required @ Stringer PCS @ 6M 8.00 PCS
Number of 10 mm Horizontal Bars required @ Stringer PCS @ 6M 3.00 PCS
# OF #16 TIE WIRE USED KGS 2.00 KGS

NOTES: DOWELS FOR LATERAL BARS ARE ALREADY INCLUDED IN THE ESTIMATES
FOR STAIRS LANDINGS YOU MAY USE THE SLAB REINFORCEMENT CALCULATOR
HAND RAILING QTY
RAILING MEMBER LENGTH NOS WT
RUNNER 32NB 20 3 3.9 234
VERTICAL 20 NB 1.5 14 2.8 58.8
292.8 KG
0.2928 MT