AR-716E/Ei V110113
ACCESS CONTROL SYSTEM
Contents
1 Products 2 User Guide 3 Terminal Cables 4 Keys
Installation
Wall Surface
According to the width of two holes on the backside of housing to nail.
Use Appropriate Fasteners Screw the mounting nails.
Screws on the wall, and then, hang Controller on the wall.
Connector Table
CN2
CN1 CN5
CN1 ON Power
Wire Application Pin Description Wire Application Pin Description
1 Reset
1 2
Reset
Power 1 Vin+ Digital Input 1 COM
RS485 NET
2 CH2 RX
Vin- 2 DI.4
CN3 TCP/IP
JP3 2
3 ACT JP4
1 Module NET
JP5 CH2 TX
Battery Power 3 BV+ 3 DI.3
4 BUSY JP2
2 LINK RS485 CH1 RX
4 BV- 4 DI.2
J5 CLEAR
3 1 RUN
CH1 TX
5 DI.1
4 1 Host RX CN2 (Only for AR-716Ei)
6 12V
CN4
5 2 BAT+
BAT+
Host TX Wire Application
J1 J2
1
6
2 Relay Relay Host Interface for Ethernet BAT (in the case)
8
CN3
6
2 DB1 DB2
K3 K4 Channel 2 1 B-
2
ON
3
PORT 1 & PORT 2
1
4
J3 J4
Busy
(RS-485 input) 2 A+
D12
5 D11 PORT 1 PORT 2 Channel 1 3 B- Wire Application Pin Color
Description
D10
6 D9 6 5 4 3 2 1 6 5 4 3 2 1 (RS-485 input) 4 A+ Buzzer 1 Gray
Buzzer Output
Host Interface for 5 B- LED 2 Brown
LED Output
Note:
(RS-485 output) 6 A+ Wiegand 3 Blue
WG DAT: 1 Inpu
Optional for TCP/IP Module.
ABA Clock Input
External battery for BAT position. CN4 4 Green WG DAT: 0 Input
J1~J4: Set N.O. or N.C. relay output (default value is N.O.). Wire Application Pin Description ABA Data Input
J5: EEPROM Restoring. Relay Output 1 K1 Power 5 Black GND
JP2~JP5: Select the interface is the Ethernet mode or the 2 K2 6 Red 12V
RS-485 mode. 3 K3
DB1&DB2: Extension Relay Board. 4 K4
5 COM
Wiring Diagram
J1
Etherent K1
B- K2
A+ CN4 K3
K4 J4
Converter&Server POWER COM
15VDC POWER COM
B- 1
12VDC DI.4 AR-716E
DI.3
A+ 2 CN5
3 CN2 DI.2
DI.1 PORT 1
4 12V
Vin+ 6 5 4 3 2 1
5 DC 1
Node 009
B- 1 Vin- CN1
6 A+ 2 BV+
~ 7 3
COM
BV-
DC 2
AR-716E
12V
Node 016 B- GND
4 CH2
Access Controller 5
A+ WG 0
B-
Node 001 CH1 WG 1
6 A+ CN3
~
Node 008
7 B-
A+
HOST
LED
BZ
Access Controller Access Reader
Operation
A. TCP/IP Mode
Hardware
Before use the Ethernet Mode, please note that JP2 ~ JP5 is transferred to the NET position.
Software
Connect the device to a computer, Then turn on your Web Browser and type "http://192.168.1.127" on IP address to start factory default webbrowser.
When you type the IP address, you will see the [Current State] page.
Login:
Factory Default :
User name: admin
Current IP address Password:(NO need to type)
Main Menu:
Current State: Connected to the controller
displays the current status.
User Password: Want to change new Account & Password, can click into.
b. Click it to update
Type the new User Name &
Password.
B. Node ID setting The hardware setup is complete, the software can be set.
Hardware
Power Off Take off the battery connector from [BAT+] socket Set up node number by 8 dip-switch Plug in battery connector
Re-apply the power
2 8 32 128
[e.g.]: Node: 002 Node: 003 Node: 007 Node: 008
ON ON ON ON ON
1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8 1 2 3 4 5 6 7 8
1 4 16 64 2 1+2 1+2+4 8
Software
1. Open the "701 Server" Software There are two ways to open the Communication Port setting window: and
Communication Port Setting
a
a. By the computer Detection results to select the port. (Use the RS-485)
b
b. Select [TCP/IP Oonly]. (Use the Ethernet)
c. Selection the options: Polling Message From Controller.
c e d. Polling Interval: 200ms, PC every 200ms inquiries once access controller's messages.
d e. Press YES
2. After COM Port setting, there are two ways to open the Node Number for Polling window: and
Node Number for Polling
There are two ways to open the 701E Parameter window: and
a
a. There is filled in AR-716E node ID to get in 716E parameter for others setting.
b
c
d
e
f
e. Setting up "Door Number" of readers
g
f. The RS-485 Access Controllers connector to the "Channel 1" of the [CN3]
g. The RS-485 Access Controllers connector to "Channel 2" of the [CN3]
h i
h. The Access Reader connector to the [PORT 1]
i. The Access Reader connector to the [PORT 2] PORT 1 PORT 2
IP Address Reset
Shift 2 dip-switch of TCP/IP module to OFF Press IP reset button more than 5 seconds TCP/IP module will restore to BAT+
factory default value as follows
ON
RESET
After "EEPROM Restoring", [RESET] will flash the red LED and then clear the memory before the action started.
Power
CN1 ON
BUSY
Reset
1 1 2
When the red LED is lit, the memory is running clear and restores the factory default 2
Reset
RS485 NET
CH2 RX
JP3
action. CN3 3 ACT TCP/IP JP4
JP5 CH2 TX
1 4 BUSY Module NET
If you do not perform "EEPROM Restoring", but the [RESET] and [BUSY] has been JP2
RS485 CH1 RX
2 LINK
lit red, indicating a problem with PCB should be excluded. 3
J5 CLEAR
CH1 TX
1 RUN
4 1 Host RX
E. About LED (lift of the PCB) 5
CN4
J1 J2
2 BAT+
BAT+
Host TX
6 1
ACT 2 Relay Relay
8
3 K1 K2
7
When the Ethernet mode is successful, [ACT] will be the green LED.
6
CN5 4
5
1 5
4
2 DB1 DB2
K3 K4
2
After "IP Address Reset", [BUSY] will be the red LED, and restore to factory default value.
ON
3
1
J3 J4
4 D12 Busy
LINK 5 D11
D10
PORT 1 PORT 2
If [LINK] lit, but the [ACT] did not light up, indicating a problem with the Ethernet
connection to be excluded.
D9~D12
Representative [CN5] DI1 ~ DI4 on the output state; if "DI1" output signal, [D9] will light green LED.