Anda di halaman 1dari 2

Page 1 of 2, Document #2220

Temperature Accessories
Rev. A-8/2000

Temperature Accessories

Contact Probes
80PK-1 & 80PJ-1 Bead Probes 80PK-7 Industrial 80T-150U

80TEMPE
T- RATU
15 RE P
0UROB
E
C

This basic, inexpensive thermocouple offers Surface Probe Universal


OF F
F

good accuracy and For flat or slightly Temperature Probe


fast response. (Not curved surfaces. For highly accurate
suitable for liquid Exposed junction allows measurement of air,
immersion.) direct contact with the surface surface, and non-corrosive
80PK-1 is compatible with being measured materials.
K-type thermometers; 80PJ-1 works Robust design for extended service life Measurement range: -50 C to 150C
with J-Type thermometers Measurement range: -127 to 600 C (-196 (-58F to 302F)
Measurement range: -40 to 260 C (-40 F to 1112 F) Output: 1mV/C or 1mV/F (switch
to 500 F) selectable)
80PK-8 Pipe Clamp
80PK-2A Temperature Probe 80TK
Immersion Probe Designed for pipe Thermocouple
OF
F
F
C 80THERMO
TK COUP

Use as a general-purpose
LE
MO

surfaces from 6.4 mm


DU
LE

probe including liquids and gels. Module


(1/4") diameter to 34.9 mm
Compatible with K-Type temperature Converts multimeters with
(1-3/8") diameter.
measuring instruments a mV range into digital
Spring-action jaw will thermometers.
Measurement range: -40 to 982 C not loosen over time, ensuring
(-40 to 1800 F) Converts K-type thermocouple
repeatable measurements signals into mV output.
Robust design for extended service life Connects to DMM via standard bannana
80PK-3A Measurement range: -29 C to 149C (-20 plugs
Surface Probe F to 300 F) Switch selectable C or F
Designed for measuring Repeatability: 0.56 C (1 F) Range: -50 C to 1000 C
the temperature of flat or (-58 to 1832 F)
slightly convex surfaces, this K type 80PJ-9 & 80PK-9
probe is ideal for hot rollers and plates. General Purpose Probes 80BK Integrated DMM
Exposed junction allows direct contact Use as surface probe
with the surface being measured Temperature Probe
and for insertion into
Measurement range: 0 to 260 C Compatible with the
air and non-caustic
(32 to 500 F) Fluke 16 and Fluke 89
gases. Series IV and other DMMs
Probe constructed of 304 with temperature measurement
80PK-4A stainless steel functions.
Air Probe 80PK-9 is compatible with K-type K-type thermocouple with standard
For air and non-caustic thermometers; 80PJ-9 operates with banana jack
gas applications. J-Type Convenient one-piece construction
Probe constructed of 304 stainless steel Measurement range: -40 to 260 C (-40 to Measurement range: -40 to 260 C
with a perforated baffle around the 500 F) (-40 to 500F)
measurement bead
Measurement range: -40 to 816C (-40 to 80PJ-EXT, 80PK-EXT, 80PT-EXT
1500 F) Thermocouple Wire
Extension Kits
80PK-5A & 80PT-5A For extending and
Piercing Probe repairing J, K or T-type
Designed for foods, thermocouple wires.
liquids and gels. Kit includes 3 meters (approx. 9 feet)
Probe made of 304 of thermocouple wire and 1 pair of
stainless steel male/female mini-connectors
80PK-5A is compatible with K-Type Maximum continuous exposure
instruments; 80PT-5A is designed for use temperature: 260 C (500 F)
with T-Type thermometers 80PK-EXT is compatible with K-type
Measurement range: -40 to 260 C thermometers; 80PJ-EXT is designed for
(-40 to 500 F) J-Type thermometers, and 80PT-EXT is
designed for T-type thermometers
80PK-6A
Exposed Probe
Use both as a surface
probe and for insertion into air
and non-corrosive gases.
Probe made of 304 stainless steel
Measurement range: -40 to 816 C (-40 to
1500 F)
Page 2 of 2, Document #2220
Temperature Accessories
Rev. A-8/2000

Temperature Accessories

Non-Contact Probes Other Temperature Accessories

80T-IR, 80T-IR/E & 80PK-IR 80CK-M & 80CJ-M 80AK


Infrared Surface Temperature Probes Type K & J Male Adapts Type-K thermocouple
mini-connector to dual
80PK-IR Mini-Connectors banana plug inputs
Compatible with Fluke 50 Series thermometers Isothermal screw Allows the Fluke 89IV or
and Fluke 16 and 89 IV DMMs, this probe meas- terminal for K or Fluke 16 multimeters to be
ures the temperature of objects that cant be J wire used with any K-type
touched. Suitable for up to 20 gauge thermocouple accessory
Senses infrared energy emitted by an object thermocouple wire Measurement range and accuracy
Instant, highly repeatable readings Color coded to industry standards is not affected by the 80AK adapter
Measurement range: -18 to 260 C (0 to 500 F) (K-yellow, J-black)
Automatic shut-off after 10 minutes extends Two per package
battery life
80T-IR
For quick, non-contact temperature measurement
in less than one second; Compatible with most Thermocouple Plug Kits
DMMs 700TC1 700TC2
Instantly measures temperatures from -18 C to A kit of 10 mini-plug connectors. A kit of 7 mini-plug connectors.
260 C (0 to 500 F) Type J (black), one Type J (black), two
Highly repeatable readings displayed in C or F Type K (yellow), one Type K (yellow), two
Optical resolution 4:1 Type T (blue), one Type T (blue), one
Output 1mV/C or 1mV/F (switch selectable) Type E (purple), one Type R/S (green), one
80T-IR/E Type R/S (green), one
This special version of the 80T-IR has: Type B or Cu (white), one
An extended measurement range: 32 to 1,000 F Type L (J-DIN) (blue), one
Measures F only (no C) Type U (T-DIN) (brown), one
Type C (red), one
Type N (orange), one
80T-IR INF
0 to
RA
500
RED
F TEM
PE
RA
80
TU PK
RE
18 PR
-IR
to OBE
260

80T-IR/E
C

INF
RA
0 to RED

80PK-IR
500
F TEM
PE 80
RA
TU
RE
T-IR
18 PR
to OBE
260
C

Anda mungkin juga menyukai