1105 - V 17 (17/02/2016)
Construction Dielectric
Jelly-filled or Dry core
Loose tubes
SM, NZDand MM
Description Singlemode, singlemode NZD,or multimodeoptical fiber cable. These fibers are
protected by jelly-filled loose tubes, which arestranded around a dielectric central
member. The cable core may be protected against water penetration by either
swellable materials (dry core) or by a jelly compound, in this case is applied over the
cable core an inner jacket. Dielectricyarns shall be applied to support tensile
strength. And this whole set is covered by a black thermoplastic Polyethylene
jacket.
Standards Compliance
ITU-T G.652 "Standard for non-dispersion shifted single-mode fiber";
ITU-T G.655 "Standard for non-zero, dispersion-shifted single-mode fiber";
IEEE P1222 "Performance and Testing Standard for All-Dielectric,
Self-Supporting (ADSS) Optical Fiber Cable";
Bellcore TR-1121 "Generic Requirements for Self-Supporting Optical Fiber
Cable".
Constructive characteristic
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
1/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.
TECHNICAL SPECIFICATION
1105 - V 17 (17/02/2016)
Buffer Tube Plastic buffer tube with filling compound to prevent water intrusion and migration.
The buffer tube shall protect the fibers against mechanical efforts.
Central Member Dielectric-material element located in the center of the core cable to prevent the
efforts of the cable tension.Ascentral member, it isapplied a bar of plasticmaterial
reinforced by FRP (Fiber Reinforced Plastic) fiberglass.
Cabling The loose tubes are stranded around of central member to form the cable core. The
core must be protected withgel or water blocking material to prevent water
intrusion. If necessary, filler rods may be applied to maintain a cylindrical core.
Tensile Strength Yarns Dielectricyarns shall be applied over the cable core or over the inner jacket, if
applicable, to support tensile strength.
Core Lay up Optical fiber quantify Loose Tube quantify Fibers per Tube
06 01 06
12 02 06
18 03 06
24 04 06
30 05 06
36 06 06
48 04 12
60 05 12
72 06 12
96 08 12
120 10 12
144 12 12
Inner Jacket When necessary, the innerjacket will be made of blackpolyethylene, weather and
UV resistant.A ripcord must be included under this jacket.
For Dry core optical cable, inner jacket will be optional.
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
2/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.
TECHNICAL SPECIFICATION
1105 - V 17 (17/02/2016)
Outer Jacket Black polyethylene material providing protection from bad weather and sunlight.
The outer jacket can be produced with low-density polyethylene or medium-density
polyethylene in accordance with client specification. When is necessary, the outer
jacket can be Flame Retardant (RC).
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
3/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.
TECHNICAL SPECIFICATION
1105 - V 17 (17/02/2016)
Cross Section
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
4/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.
TECHNICAL SPECIFICATION
1105 - V 17 (17/02/2016)
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
5/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.
TECHNICAL SPECIFICATION
1105 - V 17 (17/02/2016)
Marking Each length of cable shall be marked as described bellow, shall be clear, in relief
orwhite color on the outer jacket at intervals of 1 meter.
"FURUKAWA CFOA-x-ASy-w zF v k "Month/Year" (**) LOT nL"
Where:
X= Fiber type
SM (Singlemode fiber)
NZD (Non-zero dispersion shifted singlemode fiber)
MM (Multimode fiber)
AS = Self Suporting;
Y = Max Span Length
Max Span Length (m) Y
80 80
120 120
200 200
W= Core type
S = Dry core
G = Jelly-filled core
Z= Fiber count
V= Special fiber extra denomination:
G-652D = G.652.D singlemode fiber compliant
(50) = multimode fiber - 50 m
(62.5) = multimode fiber - 62.5 m
(50) OM3 = OM3 fibers
(50) OM4 = OM4 fibers
K = Outer Jacket material;
Type K
For cables with flame retardancy characteristic RC
Normal NR
Month/year = Month and year of manufacturing
(**) = Sequential length xxxxxx m
nL = Lot number
Observations Furukawa recommends only preformed dead end assemblies. Materials other than
preformed are not aprroved and shall not to be used unless specifically authorized
by FURUKAWA. For further information, please contact FURUKAWA.
This informative is from authorship and exclusive property of Furukawa Electric LatAm. Its integral or
6/6
partial reproduction is banned if its authorship is not mentioned, as well as lteration of its content or
context. All specifications are subject to change without notice. Photos and drawings for illustrative
purposes only.