CIRCUIT DRAWN WITH POWER SUPPLY OFF FOR TYPICAL REMOTE CONTROL

DETAILS, SEE DOCUMENT

PLUG SELECTED VOLTAGE WIRE INTO


RWS100
TERMINAL "T"
PLACE TWO REMAINING WIRES INTO TRANSFORMER VOLTAGE OPTIONS:
POSITIONS "P"
(ORDER NOT IMPORTANT)
1 AC CONNECT CORRESPONDING
TOROIDAL
POWER COLOUR TO "T"
TRANSFORMER 2 SUPPLY
TYPE 1
3
GREY 100V
FS1 - 5A
E PURPLE 110V
ANTISURGE
SK20 FS1 BROWN 120V
FS2 P P T 3 TYPE 2
_ GREY 200V
FS1 - 2.5A
+

SK14 PURPLE 230V


ANTISURGE
BROWN 270V
SK15 TYPE 3
SK2
0VAC 1 GREY 380V
FS1 - 1.6A
M SK12 120VAC 4
PURPLE
BROWN
400V
415V
ANTISURGE
0VDC
3 4 TYPE 4
24VDC
24VDC 6 GREY 480V
POSITION _ 5 NOMINAL SUPPLY
FS1 - 1.6A
+
10 WAY SK1 (OUTPUT) PURPLE 575V
SENSOR PS1 SK11
BROWN 690V
ANTISURGE
0VDC 1
INTERNAL SUPPLY FS2 - 20A ATO FAST ACTING ALL TYPES
SK16 24VDC 2 FOR ANALOGUE PCB
SK4
3 2 1 4 SK9 1 2 TYPE 5 DC (ONLY)

FS1
26 WAY
SK7 SK2 1 +
BATTERY FS3 FS2

+ - SK6 SK3 2 -
FS3 (IF FITTED) 100mA SK3 1 4 3 2 SK13 2 1 SK14 DC/DC
CONVERTER
6 SK9 SK8 1 42
SK5 SK4
5 MONITOR 3 43
RELAY SK20
2 44
SK7
SK10
1 6 _
S1

+
MAKE AT FULLY SHUT SK14
8 7
2 8 SK15
MAKE AT FULLY OPEN S2 7 9
FUSE FS1 - 20A ATO FAST ACTING
3 10 FUSE FS2 - 500mA ANTI-SURGE
BREAK AT FULLY SHUT S3 6 11
4 12 REFER TO SHEET 2 FOR NOTES
BREAK AT FULLY OPEN S4 & OPTION PCB'S IF FITTED
5 13
SK4
CLOSE 9 33
STOP/ MAINTAIN 10 34
50% SK6 OPEN 8 35
COMMON -VE 1 36
18 WAY

ESD 12 25
STOP
CLOSE
LOCAL
OPEN INTERLOCK 13 37
OPEN REMOTE
CLOSE INTERLOCK 14 38
COMMON -VE 5 31
SK1 SK2
SLOT A SLOT B

Iss Date Chkd Revision Details IQT + DEVICENET + ANALOGUE MONITORING


1 021015 JC1 First Issue www. .com
2 261115 PMJ TYPE 5 DC WIRING ROTORK CONTROLS LTD ROTORK CONTROLS INC Drawn by: PJW Circuit Diagram Number Issue Sheet
UPDATED. BATH, BA1 3JQ ROCHESTER Date : 021015 No
ENGLAND NY 14624, USA
Base WD: 304D2000
Job No : - -
304D2000 2
1
of 2
Tel:01225-733200 Tel:585-247-2304 MI No : - - B1 C1 B2 C2
IQ3
CIRCUIT DRAWN WITH POWER SUPPLY OFF

SLOT A
SK1
SLOT A
SK3
DEVICENET MODULE
(REFER TO MANUAL

1 26 V+
PUB090-003)

2 27 CAN+
3
4 28 CAN-

5 29 V-
45 SHIELD

46
E

SLOT B
SK2
SLOT B
SK3
(NETWORK ONLY)

ANALOGUE IN +VE 3 22
}
MONITORING

ANALOGUE INPUT SIGNAL


ANALOGUE

ANALOGUE IN -VE 4 19
SK6
1 0V
SUPPLY FROM SK11 ON MOTOR CONTROL PCB
2 24V
SK8
1
2

NOTES
1.FUSES:
-PS1 is a self-resetting fuse. 3.INDICATION:
-Refer to publication PUB002-039 for approved fuses FS1 and FS2. -For typical position, status and alarm indication see PUB002-041.
-S contacts are user configurable and are shown in their default
2.REMOTE CONTROL: setting.
-For typical remote control circuits refer to: -Refer to PUB002-040 for functions and configuration instructions.
-RWS indicated or PUB002-041. -Monitor Relay indicates actuator availability for remote control (shown
-For DC and AC control, connect ve/0V to terminal 36. unavailable). It can be configured to exclude local/remote selection.
-(For negative switch / positive common, refer to RWS indicated). -Refer to PUB002-040 for monitored functions and configuration
-Control signal threshold voltages: instructions.
-DC: on 16Vdc / off 8Vdc, max 60Vdc. -Voltage applied to indication contacts must not exceed 150Vac
-AC: on 60Vac / off 40Vac, max 120Vac. -Individual Switch current must not exceed 3.5A inductive, 5A resistive
-Control signal duration to be 300ms minimum. and no more than 8A in total for all 4 contacts.
-Maximum current drawn from remote control signals is:
-8mA at 24Vdc or 12mA at 120Vac. 4.BATTERY:
-Supply provided on terminals 4 & 5: -Battery maintains local and remote S contact indication only.
-Intended for remote control. -Refer to installation manual for approved replacement battery types.
-Max external load 5W at 24Vdc / 5VA at 120Vac Circuit Diagram Number Issue Sheet
No
2
See Sheet 1 for all Revision details/information 304D2000 2 of 2