Anda di halaman 1dari 4

Construction Catalysers Pvt Ltd.

484/37, Vedh, Mitramandal Colony, Parvti, Pune - 411009. Ph - 91.20.24424446. Info@concat.in


Project : Ireo - Top Roof Node No. 441
Title : Base plate detail Type 14 Load case :
Ref.file no. IP -

Reference code : IS 800 - 2007

Factored shear Factored shear Factored Axial Force Fz Factored Factored Factored
force Fx force Fy Moment M x Moment M y Torque M z
Compressive
Kg Kg Kg Kg-m Kg-m Kg-m
1534.50 2205.00 20806.50 7336.50 5113.50 3.86
* Partial safety factor, f for limit state is considered as 1.5 referring to the table 4 of IS 800-2007.

DESIGN OF INSERT PLATE


Grade of Anchor Rod = 4.6 ( Mild Steel )
Yield Stress of Anchor Rod fy = 240 N/mm
Ultimate Tensile Stress of Anchor Rod fu = 400 N/mm
Partial Safety Factor mb = 1.25 (IS 800-2007 Table-5)
Characteristic Strength of Base Concrete Fck = 20 N/mm2
f bc=allo. Bearing capacity of concrete of Grade M20 = 0.92 Kg/mm

Provide b= 520.00 mm Eccentricity mm


d= 520.00 mm e1 296.98
t= 16.00 mm

P FACT= 31209.75 Kg (PFACT = Factored axial force in Kg)


A, req.= 34018.63 mm A, Provided = 270400.00 mm
< Provided, Hence SAFE

SIZE OF INSERT PLATE


Intensity of pressure from concrete under slab = Factored Axial force / area of plate
w=P /A= 1.132 N /mm2
Greater projection beyond column, a'= 100 mm
Lesser projection beyond column, b'= 100 mm
Partial safety factor for yielding ,mo = 1.10 (IS 800-2007 Table-5)

As per IS:800-2007; Clause 7.4.3.1, min. thickness of slab base


t = SQRT[(2.5 w)(a^2-(0.3 x b^2))mo/ fy]
min. t= 9.53 mm
< Provided, Hence SAFE
Geometry INPUT
No. of bolts ,N= 4
Distance From Axes In mm
x1= 50.00 y1= 50.00
x2= 470.00 y2= 470.00

FORCE CALCULATIONS
TENSION
1 )Tensile force due to moment about X-axis; Px SHEAR Kg
Kg
Mx=P(2*(y1)^2 + 2*(y2)^2) Px= 7717.45
2 )Tensile force due to moment about Y-axis
My=P(2*(x1)^2 + 2*(x2)^2) Py= 5379.02
3) Shear force due to moment about Z- axis ;
Mz=Vz(N*e1) Vz= 3.25
4 )Shear force on each bolt along X-axis ; Vx= Fx / N Vx= 383.63
5 )Shear force on each bolt along Y-axis ; Vy= Fy / N Vy= 551.25
6 )Tensile force on each bolt due to Force along Z- axis; ( Fz/ N) = Pz = 0.00

FACTORED FORCES 13096.46 938.12

Fz = TENSION

Above calculated forces will be transferred to


bolt on left hand side directly and through
plate to horizontal bolts and will cause shear
TYPE - 14
force in the bolts.
430

So magnitude of tension and shear will


interchange for horizontal bolts and
design will have to checked for flipped forces.
490
130
=500=
600

ANCHOR BOLT DESIGN - For Vertical bolts

bolt length = 400 mm


Bar Diameter 36 mm

Bolt Shear Check


Shear capacity of Bolt IS 800
Vdsb = Vnsb / mb cl.10.3.3
Vnsb = (fub / 3) x (nn Anb + ns Asb)
ns = 0.00
nn = 1.00
Asb = ( x 36^2) / 4
= 1017.85 mm
Anb = 0.75 x Asb
= 763.38 mm

Vnsb = (fu / 3 ) x ( nn x Anb + ns x Asb )


= (400/1.732)*(1*763.38+0*1017.85)/9.81
= 17971.06 KG

Vdsb = Vnsb / mb
= 14376.85 KG

Factored Shear Force Vsb= 938.12 KG


< 14376.85 KG
Hence SAFE

Bolt Tension Check


Tension capacity of Bolt
Tdb = Tnb / mb
Tnb = 0.9fubAnb
= 0.9 x 400 x 763.385/9.81
= 28014.11 KG

Tdb = Tnb / mb
= 22411.29 KG

Factored Tension Force Tb= 13096.46 KG


< 22411.29 KG
Hence SAFE

Bolt Subject to Shear and Tension


( Vsb/Vdsb) +(Tb/Tdb) <= 1.0
= (938.12/14376.85) + (13096.46/22411.29)
= 0.35 < 1
Hence SAFE

ANCHOR BOLT DESIGN - For Horizontal bolts

bolt length = 400 mm


Bar Diameter 36 mm

Bolt Shear Check


Shear capacity of Bolt IS 800
Vdsb = Vnsb / mb cl.10.3.3
Vnsb = (fub / 3) x (nn Anb + ns Asb)
ns = 0.00
nn = 1.00
Asb = ( x 36^2) / 4
= 1017.85 mm
Anb = 0.75 x Asb
= 763.38 mm

Vnsb = (fu / 3 ) x ( nn x Anb + ns x Asb )


= (400/1.732)*(1*763.38+0*1017.85)/9.81
= 17971.06 KG

Vdsb = Vnsb / mb
= 14376.85 KG

Factored Shear Force Vsb= 13096.46 KG


< 14376.85 KG
Hence SAFE

Bolt Tension Check


Tension capacity of Bolt
Tdb = Tnb / mb
Tnb = 0.9fubAnb
= 0.9 x 400 x 763.385/9.81
= 28014.11 KG

Tdb = Tnb / mb
= 22411.29 KG

Factored Tension Force Tb= 938.12 KG


< 22411.29 KG
Hence SAFE

Bolt Subject to Shear and Tension


( Vsb/Vdsb) +(Tb/Tdb) <= 1.0
= (13096.46/14376.85) + (938.12/22411.29)
= 0.83 < 1
Hence SAFE