Low Temperature
Logging Instruments

www.antares-geo.de
ANTARES Datensysteme GmbH
Rudolf-Diesel-Str. 6
28816 Stuhr
Germany
Phone: +49 (0) 421 87194-0
Fax: +49 (0) 421 87194-25
Email: info@antares-geo.de
Web: www.antares-geo.de

(C) 1997-2017 ANTARES Datensysteme GmbH. All rights reserved

The specifications contained in this document can be modified without previous announce-
ment. No part of this document may be duplicated or transmitted without explicit written
permission of ANTARES Datensysteme GmbH.
Dear Prospective Client

I am very happy to present to you our comprehensive product line of low-temperature


instruments. These tools are developed for a large variety of applications, e.g. mining
operations, groundwater surveys, and scientific research, but also geothermal
investigations, cavern logging and deep-marine geotechnical surveys.

Over the last 20 years ANTARES has grown from a single small office in Germany to an
international company with offices in Houston and Cairo serving customers in over
30 countries. Close collaboration with our customers has been key to design our product
lines. As a result, we developed low-maintenance and reliable equipment for low-
temperature operations:

- ANTARES standalone instruments comprise several single sensor instruments, but


also some comprehensive All-In-One-Go Instruments, which combine several sensors.
- ANTARES combinable low-temperature instrument product line enables a high degree
of flexibility. Several instruments can run together in one string reducing the rig time
considerably.
- For slim and rough holes, ANTARES designed a combinable string of nuclear
instruments, which allows the measurement of GR, neutron and density logs in just one
run. The outer diameter of the string is only 43 mm and therefore, especially interesting
for coal mining logging.
- Furthermore, several instruments for cavern logging are available.

Our customers see ANTARES as a partner not only for leading edge technology but also for
training, maintenance and Research & Development. They appreciate the individual and
comprehensive support provided by ANTARES and the reliability of the tools and surface
system.

Together with my team, I hope we will become partners in the future. Discover the 'German
Engineering' difference!

Conrad Blumhagen

ANTARES 2017 1
Low Temperature Instruments

TABLE CONTENT
Tool ID OD Tmax. Cable Page
requirements
Preface 1

Standalone Instruments
Radioactive Instruments
GR 1448 38 mm/43 mm 90C 1- or 4-cond. 5
GR Adapter 1495 43 mm 90C 1- or 4-cond. 6
runs with several other instruments
Spectrum GR 2901 52 mm 60C 1- or 4-cond. 7
Spectrum GR 29N7 70 mm 60C 1- or 4-cond. 8
Slim Dual Detector Neutron 1472 38 mm 90C 1- or 4-cond. 9
Dual Detector Neutron 1497 43 mm 70C 1- or 4-cond. 10
Slim Sidewall Density 29N9 38 mm 90C 1- or 4-cond. 11
Compensated Sidewall Density 1476 52 mm 70C 1- or 4-cond. 12

Combi Instruments
Multipurpose Instrument (MPI) 1143 43 mm 90C 4-cond. 13
GR/Resistivity/Temp/SP/SPR
Combined Flowmeter Tool (CFT) 1631 43 mm/90 mm 100C 1- or 4-cond. 14
SAL/Press/Temp/Flow
Combined Salinity Tool (CST) 1628 43 mm 70C 1- or 4-cond. 15
SAL/Temp/GR

Caliper and Orientation Instruments


3-Arm Caliper 1014 43 mm 100C 1- or 4-cond. 16
4-Arm Caliper with Orientation 10N7 52 mm 60C 1- or 4-cond. 17
Orientation 1212 43 mm 100C 1- or 4-cond. 18

Resistivity Instruments
GR/Focused Electrolog 1125 52 mm 90C 4-cond. 19

Formation Evaluation
4-Arm Dipmeter 12N7 43 mm 100C 4-cond. 20
Magnetic Susceptibility 1108 43 mm 70C 1- or 4-cond. 21

Water Quality
Salinity/Temperature 1623 43 mm 90C 1- or 4-cond. 22
Milieu Monitoring 1707 43 mm 70C/125C 4-cond. 23
Temp/Press/pH/Redox/Cond./O2/Chloride
Continuous Flowmeter 1627 45 mm / 90mm 90C 1- or 4-cond. 24
High Resolution Temperature 16N7 43 mm 100C 1- or 4-cond. 25
Fluid Sampler 0409 43 mm 70C 1- or 4-cond. 26

2 ANTARES 2017
Low Temperature Instruments

TABLE CONTENT

Tool ID OD Tmax. Cable Page


requirements

Combinable Low-Temperature Instruments 27

GR Adapter 1495 43 mm 90C 4-cond. 28


Slim Dual Detector Neutron 29N8 38 mm 90C 4-cond. 29
Sidewall Density 29N9 38 mm 90C 4-cond. 30

Telemetry/GR 0921 43 mm 70C 4-cond. 31


Spectrum Gamma Ray 1489 52 mm 70C 4-cond. 32
Dual Detector Neutron 1494 52 mm 70C 4-cond. 33
Sidewall Density 1491 53 mm 70C 4-cond. 34
Full Waveform Acoustic Instrument 1313 43 mm 70C 4-cond. 35
Dual Latero Log 1113 43 mm 70C 4-cond. 36
4-Arm Caliper 1008 52 mm 70C 4-cond. 37

Cavern Logging 38

Directional Sonar Caliper 1309 72 mm 70C 4-cond. 39


DSCL/Gamma Ray/Temperature 1509 73 mm 70C 4-cond. 41
Pulsed Neutron Blanket/CCL 1463 43 mm 70C 4-cond. 42
Pulsed Neutron Blanket/DSCL 1464 43 mm 70C 4-cond. 43
Gamma/Temperature/DSCL 1466 44.5 mm 70C 4-cond. 44

Furthermore available 45

ANTARES Standard Surface System 46


Contacts 47

ANTARES 2017 3
Standalone Tool Product Line

Standalone Tool Product Line


The ANTARES Standalone and Slim Tool Product line comprises several slim instruments, which are
optimized for low temperature slim-hole applications such as mining, groundwater or scientific
research.

Several instruments combine various sensors in one instrument and allow for easy handling and short
logging time.

As a special feature, we offer a GR Adapter for sevaral instruments to add lithology and depth
determination measurements.

4 ANTARES 2017
Standalone Tool Product Line

Gamma Ray
The ANTARES 1448 Gamma Ray (GR) measures gamma rays emitted by the formation surrounding
the borehole. All detected gamma rays are counted for the total-gamma ray curve. The Gamma
Ray Log can be ran in open and cased holes, in all mud systems and in dry holes. The instrument is
available in two different tool diameters.

Specifications
Diameter: 42 mm/ (1.65") Detector:
38 mm (1.50") GR NaI scintillation crystal
Length: 1,185 mm (46.7)
Weight: 6 kg (13 lbs)

Max. Temp: 90C (194F) Measure Point (from bottom):


Max. Pressure: 20 MPa (2900 psi) 153 mm (6.0")

Max. Cable Length: 2500 m (8200 ft)


Cable Requirements: mono- or 4-conductor
Telemetry Required: no
Data Transmission: digital

Top Connector: GC1, GO1, GC4 or GO4


Bottom Connector: none

Measuring Parameters
Measuring Range: Accuracy
GR: 0 to 3000 gAPI GR: + 5 % of measured values*

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.8") Logging Speed: 9 m/min (1800 ft/hr)
63 mm (2.5") Sample Rate: selectable
Max. Hole Diameter: NA

Standard Displayed Curves


GR in API Gamma Ray
CHV in V Cable Head Voltage
TEMP in C Electronics Temperature

Combinability
none

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 5
Standalone Tool and Combinable Radioactive Tool Product Line

GR Adapter
The ANTARES 1495 GR Adapter can be added to several ANTARES Low Temperature instruments of
the Standalone Tools as well as on the Combinable Radioactive Tool Product line to add lithology and
depth determination information. The Gamma Ray Log can be ran in open and cased holes, in all mud
systems and in dry holes.

Specifications
Diameter: 42.4 mm (1.67") Sensors:
Length: 1,594 mm (62.8) NaI Scintillation Crystal
Weight: 8 kg (17 lbs)
Measure Points (from bottom):
Max. Temp: 90C (194F) 1,316 mm (51.8")
Max. Pressure: 20 MPa (2900 psi)

Max. Cable Length: 2,500 m (8,200 ft)


Cable Requirements: mono or 4-conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GO4 or GC4


Bottom Connector: GO4 or GC4

Measuring Parameters:
Measuring Range: Accuracy:
GR: 0 to 3000 gAPI GR: + 5 % of measured values

Resolution:
GR: 3 API

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 65 mm (2.6) Logging Speed: 9 m/min
Max. Hole Diameter: NA (1800 ft/hr)
Sample Rate: selectable

Standard Displayed Curves

GR in API Gamma Ray


CHV in V Cable Head Voltage
TEMP in C Electronics Temperature

Combinability
With other tools from the ANTARES Standalone and Combinable Radioactive Tool Families.

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

6 ANTARES 2017
Standalone Tool Product Line

Spectrum Gamma Ray

The ANTARES 2901 Standalone Spectrum Gamma Ray (SGR) is an instrument logging the natural
gamma radiation. The tool measures the entire gamma ray spectrum from 0 to 3000 keV. It records
the total amount of gamma rays and provides quantitative measurements of the 40Potassium,
232
Thorium and 238Uranium contents of the formation. The Spectrum Gamma Ray Log can be run in
open and cased holes with all mud systems and also in dry boreholes.

Specifications
Diameter: 52 mm (2.05") Detector Type: BGO scintillation crystal
Length: 1,080 mm (42.5")
Weight: 7.5 kg (17 lbs)
Spectrum: 0...3000 keV,
Max. Temp: 60C (140F) 256 Channels
Max. Pressure: 20 MPa (2,900 psi)

Max Cable Length: 2,500 m (8,200 ft)


Cable Requirements: mono- or 4-conductor
Telemetry required: no
Data transmission: digital

Top Connector: GC1, GC4, GO1 or GO4


Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
GR 0...3000 API GR + 3 % of measured values*
K 0...50 % K, U, Th + 4 % of measured values*
U 0...500 ppm
Th 0...500 ppm

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (3) Logging Speed: 3-6 m/min
Max Hole Diameter: NA 590 - 1200 ft/hr
Sample Rate: selectable

Displayed Standard Curves


GR in gAPI Gamma Radiation
K in % Potassium Content
Th in ppm Thorium Content
U in ppm Uranium Content
K/Th Potassium plus Thorium Content
ChiSqr Chi-Square - a measurement for the quality of the spectrum fitting
RThK Ration between Thorium and Potassium Content
RThU Ration between Thorium and Uranium Content
RUK Ration between Uranium and Potassium Content

Combinability
none

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 7
Standalone Tool Product Line

Spectrum Gamma Ray


The ANTARES 28N7 Standalone Spectrum Gamma Ray (SGR) is an instrument logging the natural
gamma radiation. The tool measures the entire gamma ray spectrum from 0 to 3000 keV. It records
the total amount of gamma rays and provides quantitative measurements of the 40Potassium,
232
Thorium and 238Uranium contents of the formation. The Spectrum Gamma Ray Log can be run in
open and cased holes with all mud systems and also in dry boreholes.

Specifications
Diameter: 70 mm (2.76") Detector Type: BGO scintillation crystal
Length: 1,400 mm (55.1")
Weight: 24 kg (53 lbs)
Spectrum: 0...3000 keV,
Max. Temp: 60C (140F) 256 Channels
Max. Pressure: 20 MPa (2,900 psi)

Max Cable Length: 2500 m (8200 ft)


Cable Requirements: mono- or 4-conductor
Telemetry required: no
Data transmission: digital

Top Connector: GC1, GC4, GO1 or GO4


Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
GR 0...3000 API GR + 3 % of measured values
K 0...50 % K, U, Th + 4 % of measured values
U 0...500 ppm
Th 0...500 ppm

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 95 mm (3.7) Logging Speed: 3-6 m/min
Max Hole Diameter: NA 590 - 1200 ft/hr
Sample Rate: selectable

Displayed Standard Curves


GR in gAPI Gamma Radiation
K in % Potassium Content
Th in ppm Thorium Content
U in ppm Uranium Content
K/Th Potassium plus Thorium Content
ChiSqr Chi-Square - a measurement for the quality of the spectrum fitting
RThK Ration between Thorium and Potassium Content
RThU Ration between Thorium and Uranium Content
RUK Ration between Uranium and Potassium Content

Combinability
none

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
8 ANTARES 2017
Standalone Tool Product Line

Slim Dual Detector Neutron


The ANTARES 1472 Slim Dual Detector Neutron instrument works with a chemical source and two
neutron detectors made of Lithium-Glass. The source emits neutrons which are slowed down and
then captured, primarily by hydrogen atoms in the formation fluids. The detectors count the neutrons
deflected back to the tool. The ratio of the short space over the long space count rate is an indicator for
porosity, using the fact that the tool responds primary to the hydrogen content of the formation. The
tool is run standalone or in combination with GR Adapter 1495.

Specifications
Diameter: 38 mm (1.50") Sensors:
Length: 2,038 mm (80.7) Neutron Detectors:
Weight: 10 kg (22 lbs) Type: Lithium-Glass
No: 2
Max. Temp.: 90C (194F)
241
Max. Pressure: 20 MPa (2900 psi) Source: 3,7 GBq (100 mCi) AmBe

Max Cable Length: 2500 m (8200 ft)


Cable Requirements: mono or 4-conductor Measure Points (from source):
Telemetry Required: no LS 372 mm (14.7")
Data Transmission: digital SS 172 mm (6.8")

Top Connector: GC1, GO1, GC4 or GO4 Accessories:


Bottom Connector: none Decentralizer

Measuring Parameters:
Measuring Range: Accuracy:
Count rate LS: 0 to 65535 cps + 5 % of the reading
Count rate SS: 0 to 65535 cps

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 63 mm (2.5) Logging Speed: 3-6 m/min
Max. Hole Diameter: 400 mm (15.8") (590 - 1200 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


SSN in cps Near detector counts from Short Space Detector
LSN in cps Far detector counts from Long Space Detector
SSN/LSN Count rate ratio (SSN/LSN)
CHV in mV Cable Head Voltage
Temp in C Temperature of Electronics

Combinability
With 1495 GR Adapter on top.

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 9
Standalone Tool Product Line

Dual Detector Neutron


The ANTARES 1497 Dual Detector Neutron tool is designed to deliver porosity measurements in slim
fluid-filled boreholes, both open and cased. The instrument works with a chemical source and two
neutron detectors. The source emits neutrons, which are slowed down and then captured, primarily by
hydrogen atoms in the formation fluids. The detectors count the neutrons deflected back to the tool.
The ratio of the short space over the long space count rate is a porosity indicator, using the fact that the
tool basically responds to the hydrogen content of the formation.

Specifications
Diameter: 53 mm (2.09") Neutron Detectors:
Length: 2,529 mm (99.6) Type: Lithium Glas
Weight: 10 kg (22 lbs) No: 2
241
Max. Temp: 70C (158F) Source: 111 GBq (3 Ci) AmBe
Max. Pressure: 30 MPa (4350 psi) (optional 129.5 GBq, 3.5 Ci)

Max Cable Length: 2500 m (8200 ft) Measure Points (from source):
Cable Requirements: mono- or 4-conductor LS 760 mm (29.9")
Telemetry required: no SS 400 mm (15.8")
Data Transmission: digital

Top Connector: GC1, GC4, GO1 or GO4


Bottom Connector: Source

Measuring Parameters:
Measuring Range: Accuracy:
Count rate LS: 0 to 65535 cps Count rates: +5 % of the reading
Count rate SS: 0 to 65535 cps Caliper: + 2 mm (0.08")
Caliper: 457 mm (18")

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 78 mm (3.1) Logging Speed:3-6 m/min (590 - 1200 ft/hr)
Max. Hole Diameter: 255 mm (10.0") Sample Rate: selectable

Standard Displayed Curves


SSN in cps Near detector counts from Short Space Detector
LSN in cps Far detector counts from Long Space Detector
SSN/LSN Count rate ratio (SSN/LSN)
CHV in mV Cable Head Voltage
Temp in C Temperature of Electronics

Combinability
With 1495 GR-Adapter on top

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

10 ANTARES 2017
Standalone Tool and Combinable Radioactive Tool Product Line

Slim Sidewall Density


The ANTARES 29N9 Slim Sidewall Density instrument works with a Cesium source and two detectors.
From the energy spectrum and count rates of the two counters, the borehole compensated formation
bulk density can be estimated. The tool is run standalone or in combination with GR Adapter 1495
and/or Slim Dual Detector Neutron (above).

Specifications
Diameter: 38 mm (1.50") Detectors:
Length: 2,175 mm (85.6) Type: NaI Scintillation Crystal
Weight: 10 kg (22 lbs) No: 2

Max. Temp.: 90C (194F) Source: 3.7 GBq (100 mCi) 137Cs
Max. Pressure: 20 MPa (2900 psi)

Max Cable Length: 2,500 m (8,200 ft) Measure Points (from source):
Cable Requirements:4-conductor LS 622 mm (24.5")
(mono-conductor for SS 318 mm (15.0")
standalone version only)
Telemetry Required: no Accessories:
Data Transmission: digital Decentralizer

Top Connector: GC4 or GO4


(GC1 or GO1, standalone
version)
Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
Count rate LS: 0 to 65535 cps +5 % of the reading
Count rate SS: 0 to 65535 cps

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 63 mm (2.5) Logging Speed: 3-6 m/min
Max. Hole Diameter: 400 mm (15.8") (590 - 1200 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


SSN in cps Near detector counts from Short Space Detector
LSN in cps Far detector counts from Long Space Detector
SSN/LSN Count rate ratio (SSN/LSN)
CHV in mV Cable Head Voltage
Temp in C Temperature of Electronics

Combinability
With ANTARES 1495 GR and Dual Detector Neutron tools from the ANTARES Combinable
Radioactive Tool Family.

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 11
Standalone Tool Product Line

Sidewall Density
The ANTARES 1476 Sidewall Density instrument includes a Cesium source emitting gamma rays and
two detectors. From the energy spectrum and count rates of the two counters, the borehole
compensated formation bulk density is calculated. A caliper measurement is provided, permitting
compensation for borehole effects. The tool can be run in any mud. A correction curve indicates the
influence of the borehole rugosity.

Specifications
137
Diameter (max): 53 mm (2.09") Source Type: Cs
Length: 2598 mm (102.3) Recommended Source Activity:
Weight: 30 kg (67.5 lbs) 3.7 to 11.1 GBq (0.1 to 0.3 Ci)
Detector Type: NaI Scintillation
Max. Temp: 70C (158F) Crystal
Max. Pressure: 20 MPa (2900 psi) No of Detectors: 2

Max Cable Length: 2500 m (8200 ft) Measure Points (from bottom):
Cable Requirements: 1- or 4-Conductor DEN: 258 mm (10,16)
Telemetry required: no (depending on source activity)
Data Transmission: digital Caliper 862 mm (33,94)

Top Connector: GC1, GO1, GC4 or GO4


Bottom Connector: Source

Measuring Parameters
Measuring Range: Accuracy:
DEN: 1-3 g/cm3 DEN +0.1 g/cm3
Caliper: 53-457 mm (18) (for 2 - 3 g/cm3 formation
density)

Logging parameters
Recommended Recommended
Min. Hole Diameter: 78 mm (3.1) Logging Speed: 6 m/min (1200 ft/hr)
Max. Hole Diameter: 457 mm (18)

Standard Displayed Curves


3
Density in g/cm Caliper Corrected Bulk Density
Correction in g/cm3 Compensated Density Correction
Caliper in mm or in Borehole Diameter

Combinability
With 1495 GR-Adapter.

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
12 ANTARES 2017
Standalone Tool Product Line

Multipurpose Instrument (MPI)

The ANTARES 1143 Multipurpose Instrument measures various parameters (Gamma Ray/
Resistivity/Temperature) providing mud and surrounding formation parameters. As it logs
several measurements in one run it can save considerable rig time.

Specification
Diameter 42 mm (1.65") Sensors:
Length: 7,940 mm (312.6") Gamma Ray
42 mm
w/o GR, Temp 7,500 mm (295.3") Spontaneous Potential
Weight: 26 kg (57 lbs) Resistivity: ES 16/64
Temperature

3670 mm
Max. Temperature: 100 C (212 F) Single Point Resistance
Max. Pressure: 20 MPa (2900 psi)
Measure points (from bottom):
Max Cable Length: 2500 m (8200 ft) GR 2,506 mm (98.7")
Cable Requirements:4-conductor Temperature 2,300 mm (90.6")
Telemetry required: no SP 1,780 mm (70.1")
Data Transmission: digital Long Normale 1,780 mm (70.1")
Short Normale 560 mm (22,0")
Top Connector: GO4 or GC4 SPR 135 mm (5.3")
Bottom Connector: none
Accessories:
Bridle (always included)

2130 mm
Measuring Parameters GR
Measuring range Accuracy
Temperature: -5 to 80 C Temperature: + 0.4 C
Gamma Ray: 0 to 3000 API GR: +3 % TEMP
SP: -10,000 to 10,000mV SP: +1 %
SPR 0.4 to 10,000 OHmm SPR: + 0.01 %
16/64 Resistivity (Short/Long Resistivity: + 0.1 OHmm +0.01.%
Normal):
0.2 to 10,000 Ohmm Resolution
Temperature 0.01 C
GR: 3 API Long
SP: 0.3 mV Normal,
SPR: 0.1 Ohmm SP
2085 mm

Resistivity: 0.1 OHmm


Logging parameters
Recommended Recommended
Min. Hole Diameter: 78 mm (3.07") Logging Speed: 6 m/min (1200 ft/hr ) Short
Max. Hole Diameter: NA Normal
Displayed Standard Curves
SP in mV Spontaneous Potential
GR in gAPI Total Gamma Ray
BHT in C or F Borehole Temperature SPR
SHNO in mV 16 Resistivity / Short Normal
LONO in mV 64 Resistivity / Long Normal
SPR in mV Single Point Resistance
CHV in V Cable Head Voltage
Temp in C Electronics Temperature
Application
Combinability
Application
none

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 13
Standalone Tool Product Line

Combined Flowmeter Tool (CFT)


ANTARES 1631 Salinity/Pressure/Temperature/Flowmeter Instrument combines several measure-
ments in one instrument. This combination provides valuable information especially for hydrological
applications.
Specification
Diameter 42,4 mm (1.67") Sensors:
Flowmeter: 43 mm (1.69") Temperature
90 mm (3.54") Flowmeter
Length: 2,718 mm (107") Pressure
Weight: 14 kg (31 lbs) Conductivity

Max. Temperature: 100C (212F) Measure points (from bottom):


Max. Pressure: 20 MPa (2900 psi) Conductivity 1235 mm (48.6")
Temperature 1035 mm (40.7")
Max. Cable Length: 2500 m (8200 ft) Pressure 975 mm (38.4")
Cable Requirements: mono- or 4-conductor Flowmeter 113 mm (4.4")
Telemetry required: no
Data Transmission: digital

Top Connector: GO1 or GO4


Bottom connector: none

Measuring Parameters: COND


Measuring range Resolution
Pressure 0 to 200 bar Temperature 0.01 C
Temperature 0 to 100 C Pressure 1 mbar
Conductivity I 0 to 3 mS/cm Conductivity I 0.001 mS/cm
TEMP
Conductivity II 0 to 30 mS/cm Conductivity II 0.01 mS/cm
Conductivity III 0 to 250 mS/cm Conductivity III 0.1 mS/cm
Flow -1000 to 1000 rpm Flow 192 Imp./U

Accuracy
Conductivity +2 % PRES
Temperature + 0,2 C
Pressure + 0.1 %
Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.8) Logging Speed: 3-6 m/min
Max Hole Diameter: NA 590 - 1200 ft/hr
Sample Rate: selectable Centralizer

Displayed Standard Curves


BHT in C /F Borehole temperature FlowRaw in cps Rotational speed of the
CHV in V Cable Head Voltage flowmeter (w/direction)
TEMP in C/F Instrument Temperature Flow in rpm Calibrated rotational
BHT in C/F Borehole Temperature speed of the flowmeter
SAL in mS/cm Apparent Conductivity (w/direction) Flowmeter
BHP in bar Borehole Pressure Spinner
OD 90 mm
Combinability
Application or
With 1495 GR Adapter on top OD 45 mm

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.

14 ANTARES 2017
Standalone Tool Product Line

SAL/TEMP/GR

The ANTARES 1628 Conductivity/Temperature/GR Instrument provides fluid temperature and con-
ductivity measurements. From fluid conductivity the fluid salinity can be calculated. The log can be
recorded upwards or downwards to minimize fluid disturbance. For correlation purpose the tool
includes a Gamma Ray scintillation detector, measuring the total gamma rays emitted by the
surrounding formation.

Specification
Diameter 43 mm (1.69 ) Sensors:
Length: 1,663 mm (65.47") Temperature
Weight: 7.1 kg (3.2 lbs) Fluid Conductivity
Gamma Ray
Max. Temperature: 70 C (158 F)
Max. Pressure: 20 MPa (2900 psi) Measure points (from bottom):
Temperature 63 mm (2.48")
Max. Cable Length: 2500 m (8200 ft) Fluid Conductivity 188.5 mm (7.42")
Cable Requirements: mono- or 4-conductor GR 560 mm (22.05")
Telemetry required: no
Data Transmission: digital

Top Connector: GO1 or GO4


Bottom connector: none

Measuring Parameters
Measuring range Accuracy
Temperature 5 to 80 C Conductivity +1 %
41 to 176 F Temperature + 0.1 C
Conductivity I 0 to 3 mS/cm GR + 3 % of measured
Conductivity II 0 to 30 mS/cm values
Conductivity III 0 to 300 mS/cm Resolution
GR 0 to 10,000 cps Conductivity I 0,001 mS/cm
0 to 9,000 gAPI Conductivity II 0.01 mS/cm
Conductivity III 0.1 mS/cm
Temperature 0.01 C

Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 75 mm (3") Logging Speed GR: 6 m/min
Max Hole Diameter: NA (1200 ft/hour)
Sample Rate: selectable

Standard Displayed Curves


CHV in V Cable Head Voltage GR in cps or gAPI Gamma Ray
TEMP in C/F Instrument SAL in mS/cm Apparent Conductivity
Temperature
BHT in C/F Borehole
Temperature

Combinability
Application
With 1495 GR Adapter

ANTARES is continually updating and improving its high performance and quality logging system and instruments. For this reason the
specifications are subject to change without prior notice.
ANTARES 2017 15
Standalone Tool Product Line

3-Arm Caliper
The ANTARES 1014 Caliper tools is a motorized 3-Arm instruments. The measurements cover a
range between 43 mm and 700 mm (1.7" and 27.6").

Specifications
Diameter: 43 mm (1.69") Sensors: Potentiometric Linear
Length: 1,940 mm (76.4") Transducer
Weight: 12 kg (26 lbs)
Measure Points (from bottom):
Max. Temp: 100C (212F) 135 mm (5.3)
Max. Pressure: 20 MPa (2,900 psi)

Max cable length: 2500 m (8,200 ft)


Cable Requirements: mono- or 4-
Conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GC1, GO1, GC4 or


GO4
Bottom Connector: none

Measuring Parameters:
Measuring Range: 43 - 700 mm Accuracy: + 2 mm (0.08")
(1.7"-27.6") Resolution: 0.1 mm (0.004")

Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 68 mm (2.7") Logging Speed: 10 m/min (1950 ft/hr)
Max. Hole Diameter: 700 mm (27.6") Sample Rate: selectable

Displayed Standard Curves


CAL in mm or inch Caliper/Borehole Diameter
CHV in V Cable Head Voltage
Temp in C Electronics Temperature

Combinability
With 1495 GR Adapter on top

ANTARES is continually updating and improving its high performance and quality logging system and instruments. For this reason the
specifications are subject to change without prior notice.
16 ANTARES 2017
Standalone Tool Product Line

4-Arm Caliper/Orientation
The ANTARES 10N7 Caliper tools is a motorized 4-Arm instruments. The X-Y caliper accurately
measures in two axes of the well bore for borehole diameters up to 1,000 mm (39.4 in). Together with
the orientation module the shape and direction of the borehole can be measured.

Specifications
Diameter: 52 mm (2.05") Sensors:
Length: 2,311 mm (91.0") Caliper: Potentiometric Linear
Weight: 18 kg (40 lbs) Transducer
Orientation : Magnetometer
Max. Temp: 70C (158F) Inclinometer
optional available: 100C (212F)
Max. Pressure: 20 MPa (2,900 psi) Measure Points (from bottom):
Caliper: 105 mm (4.1)
Max Cable Length: 2,500 m (8,200 ft) Orientation: 2,156 mm (84.9")
Cable Requirements: mono- or 4-
conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GC1, GO1, GC4 or


GO4
Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
Caliper: 55 to 700 mm Caliper: + 2 mm (0.08")
(2.2"-27.6") Deviation: + 0.5
w/extensions: to 1000 mm Azimuth: +3%
(39.4")
Deviation: 0 to 60 Resolution:
Azimuth: 0 to 360 Caliper: 0.1 mm (0.004")
Deviation: 0.1
Azimuth: 0.1

Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 77 mm (3.0") Logging Speed: max. 10 m/min
Max Hole Diameter: 1000 mm (39.4") 1950 ft/hr
Sample Rate: selectable

Displayed Standard Curves


CAL in mm or inch Caliper/Borehole Diameter
caculated from X- and Y Caliper
XCAL in mm or inch Caliper in X-Direction
YCAL in mm or inch Caliper in Y-Direction
CHV in V Cable Head Voltage
Temp in C Electronics Temperature
Azimuth in deg Direction of Arm No. 1 (referenced to North)
Deviation in deg Deviation of the borehole referenced to Vertical in deg

Combinability
With 1495 GR-Adapter

ANTARES is continually updating and improving its high performance and quality logging system and instruments. For this reason the
specifications are subject to change without prior notice.
ANTARES 2017 17
Standalone Tool Product Line

Orientation
The ANTARES 1212 Orientation Instrument allows for detailed measurement of the borehole
direction. From the inclinometer and magnetometer measurements the azimuth and the deviation
are calculated. The tool can be run in open and cased holes (deviation only) and is independent from
the mud system.

Specifications
Diameter: 43 mm (1.69") Sensors:
Length: 1,048 mm (41.3") Orientation : Magnetometer
Weight: 5 kg (11 lbs) Inclinometer

Max. Temp: 70C (158F) Measure Points (from bottom):

Orientation Instrument
Max. Pressure: 20 MPa (2,900 psi) Orientation: 261 mm (10.3")

Max Cable Length: 2,500 m (8,200 ft) Optional Equipment:


Cable Requirements: mono- or 4- Sinker Bar: 9.7 kg (21 lbs)
conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GC1, GO1, GC4 or


GO4
Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
Deviation: 0 to 180 Deviation: + Meas. Value x 0.001+
Azimuth: 0 to 360 0.7
Azimuth: + Meas. Value x
0.001+1.2

Resolution:
Deviation: 0.01
Azimuth: 0.1

Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 68 mm (2.7") Logging Speed: max. 10 m/min
Max Hole Diameter: NA 1950 ft/hr
Sinker Bar

Sample Rate: selectable

Displayed Standard Curves


CHV in V Cable Head Voltage
Temp in C Electronics Temperature
Azimuth in deg Direction of the borehole (referenced to North)
Deviation in deg Deviation of the borehole referenced to Vertical in deg

Combinability
With 1495 GR-Adapter

ANTARES is continually updating and improving its high performance and quality logging system and instruments. For this reason the
specifications are subject to change without prior notice.
18 ANTARES 2017
Standalone Tool Product Line

GR/Focused Electrolog
The ANTARES 1125 Gamma Ray Focused Electrolog measures gamma ray and resistivity parameters.
The focused electrolog works with one source electrode and two guard electrodes to focus the current
into the formation. It results in a high vertical resolution. The GR detector measures the natural
gamma radiation emitted from the surrounding formation.

Specification
Diameter 42.4 mm (1.67") Sensors:
Length: 5,327 mm (209.7") GR Scintilation Crystal
Transport Length: 2,210 mm (87.2") FEL Electrodes
Weight: 13.8 kg (30 lbs)
Measure points (from bottom):

3000 mm
Bridle
Max. Temperature: 90 C (194 F) GR 151 mm (5.9")
Max. Pressure: 20 MPa (2900 psi) FEL 996 mm (39.2")

Max. Cable Length: 2,500 m (8,200 ft) Accessories:


Cable Requirements: 4-Conductor Bridle included
Telemetry required: no
Data Transmission: digital

Top Connector: GC4 or GO4


Bottom Connector: none

Measuring Parameters
Measuring range Accuracy
Gamma Ray: 0 - 3000 API GR: + 3 % of measured
FEL1: 0 - 5,000 Ohmm values

5,327 mm
FEL2: 0 - 2,000 Ohmm FEL1: + 1%
FEL2: + 1%
Resolution
FEL1: 0.1 Ohmm
FEL2: 0.5 Ohmm
GR: 3 API
FEL

Logging parameters
Recommended Recommended
Min. Hole Diameter: 68 mm (2.7") Logging Speed: 10 m/min (2000 ft/hr)
Max Hole Diameter: NA

Standard Displayed Curves


GRRaw in cps Raw Gamma Ray Count Rate
GR in gAPI Total Gamma Ray
FEL in Ohmm Resitivity from Frocused Electrolog
CHV in V Cable Head Voltage
ETemp in C Electronics Temperature
GR

Combinability
Application
none

Application

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 19
Standalone Tool Product Line

4-Arm Dipmeter
The ANTARES 12N7 4-Arm Dipmeter is a pad-type device to detect changes in formation resistivity
which are obtained from short spaced focused electrodes pressed against the borehole wall.
Simultaneous measurements are recorded at each of the four pads. The curves are later correlated in
order to determine dip angles relative to the borehole. All curves including the caliper are used to
determine the true formation dip.
Specifications
Diameter: 52 mm (2.05") Sensors:
Length: 2,650 mm (104.3) Pad resistivity
Weight: 12 kg (26 lbs) Caliper
3-axis Accelerometer
Max. Temp: 70C (158F) 3-axis Magnetometer
Max. Pressure: 20 MPa (2900 psi) GR (optional)

Max. Cable Length: 2,500 m (8,200 ft) Measure Points (from bottom):
Cable Requirements: 4-conductor Resistivity: 580 mm (22.8")
Telemetry required: no
Data Transmission: digital

Top Connector: GO4 or GC4


Bottom Connector: none
No of Arms: 4

FIGURE WILL FOLLOW


Measuring Parameters:
Measuring Range: Accuracy
Caliper: 65 to 250 mm Caliper: +5 mm
Pad Resistivity 0.1 to 50,000 Ohmm Pad Resistivity: +. 0.1 Ohmm

Logging Parameters
Recommended
Min. Hole Diameter: 65 mm (2.6) Recommended
Max. Hole Diameter: 250 mm Logging Speed: 6 m/min
(9.8") (900 ft/hr)

Standard Displayed Curves


GR in API Gamma Ray (opt.)
CHV in V Cable Head Voltage
TEMP in C Electronics Temperature
Pad1 to Pad4 Resistivity curves from the pad electrodes
Rad1 to Rad 4 in mm or inch Radius 1 to Radius 4
Cal13 and Cal24 in mm or inch Caliper 13 and Caliper 24,
Cal in mm or inch Average Borehole Caliper
RelBearing in deg High Side of the instrument referenced to Pad No. 1.
DriftAzimuth in deg Direction of the borehole (referenced to North) in deg.
Dev in deg Deviation of the borehole referenced to vertical
AZ in deg Azimuth offset from magnetic north
GR (cts/sec or API) (optional)

Combinability
none

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

20 ANTARES 2017
Standalone Tool Product Line

Magnetic Susceptibility

The ANTARES 1108 Magnetic Susceptibility instruments is a standalone logging tool. The
determination of magnetic susceptibility is widely used in mineral exploration and lithology
evaluation.

Specification
Diameter 43 mm (1.69") Sensors:
Length: 1,500 mm (59,1") Three coil systems
Weight: 7 kg (15 lbs)
Measure point (from bottom):
Max. Temperature: 70 C (158 F) 230 mm (9.1")
Max. Pressure: 20 MPa (2,900 psi)

Max cable length: 2,500 m (8,200 ft)


Cable Requirements: 1- or 4-Conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GC1, GO1, GC4 or GO4


Bottom Connector: none

Measuring Parameters
Measuring range : Resolution
1 x -10-5 SI Units to 1 x 10-1 SI-Unit -5
10 SI-Unit
Two Ranges Temperature Compensation
for 0 to 60C

Logging parameters
Recommended Recommended
Min. Hole Diameter: 78 mm (3.07") Logging Speed: 6 m/min
Max Hole Diameter: NA 1200 ft/hr

Standard Displayed Curves


ImI in mA Imaginary Component of Current
ImU in mV Imaginary Component of Voltage
ReI in mA Real Component of Current
ReU in mV Real Component of Voltage
Susz in 10-4 SI Temperature Compensated Magnetic Susceptibility
CHV in V Cable Head Voltage
Temp in C Coil Temperature

Combinability
Application
none

Application
ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 21
Standalone Tool Product Line

SAL/TEMP
The ANTARES 1623 Fluid Conductivity/Temperature Instrument measures the electric resistivity of
water in the borehole. The salinity of the water can be determined from the conductivity readings.
Together with the temperature logs, The combination of the Temperature and salinity logs
provides an indication of vertical movement of the water.

Specification
Diameter: 42.4 mm (1.67") Sensors:
Length: 1,281 mm (50.4") Temperature: Pt 1000
Transport Length: 1,306 mm (51.4") Conductivity: 4 electrodes
Weight: 5.3 kg (12 lbs) conductivity
optional: GR NaI scintillation
Max. Temperature: 100 C (212 F) crystal
Max. Pressure: 20 MPa (2,900 psi)
Measure points (from bottom):
Max. Cable Length: 2,500 m (8,200 ft) Conductivity: 187 mm (7.4")
Cable Requirements: mono- or 4-Conductor Temperature: 50 mm (2.0")
Telemetry required: no
Data Transmission: digital

Top Connector: GC1, GC4, GO1 or GO4


Bottom Connector: none

Measuring Parameters:
Measuring Range Resolution
Temperature 0 to 100 C Temperature 0.01 C0
Conductivity I 0 to 3 mS/cm Conductivity I 0.001 mS/cm
Conductivity II 0 to 30 mS/cm Conductivity II 0.01 mS/cm
Conductivity III 0 to 250 mS/cm Conductivity III 0.1 mS/cm

Accuracy
Conductivity +2 %
Temperature +0.2 C
COND
Logging parameters
Recommended Recommended
Min. Hole Diameter: 68 mm (2.7) Logging Speed: 3-6 m/min
Max Hole Diameter: NA 590 - 1200 ft/hr TEMP
Sample Rate: selectable

Displayed Standard Curves


BHT in C /F Borehole Temperature
SAL in mS/cm Apparent Conductivity
CHV in V Cable Head Voltage
ETemp in C/F Instrument Temperature

Combinability
With 1495 GR Adapter on top

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.

22 ANTARES 2017
Standalone Tool Product Line

Milieu Monitoring
The 1707 ANTARES Milieu Monitoring Instrument measures parameters describing the borehole
fluid, such as pressure, temperature, fluid conductivity, oxygen and pH.

Specifications
Diameter: 43 mm (1.69") Sensors:
Length: 1.470 mm (57.9) Temperature
Weight: 6 kg (13 lbs) Pressure
Conductivity (Salinity)

Communication section
Max. Temp.: 50C (122F) O2
Max. Pressure: 15 MPa (2175 psi) pH
Redox
Max Cable Length: 2,500 m (8,200 ft)
Cable Requirements: 4-Conductor Optional sensors:
Telemetry Required: no Chloride
Data Transmission: digital GR

Top Connector: GC4 or GO4 Measure Points (from bottom)


Bottom Connector: none 70 mm (2.8")

Measuring Parameters:
Measuring range Accuracy
Pressure 0 to 1000 dbar Oxygen + 0.1 ppm or
Temperature -1 to 50 C +1% saturation
Cond. Salt Water 0 to 64 mS/cm pH + 0.01 pH
Cond. Fresh Water 0 to 6400 S/cm Redox +1 mV
Oxygen 0 to 50 ppm
0 to 500 % sat. Resolution
pH 0 to 14 pH Pressure 0.0015 % full scale
Redox +/- 1000 mV Temperature 0.001 C
Cond.Salt Water 0.001 mS/cm
Accuracy Cond. Fresh Water 0.1 S/cm
Pressure + 0.05 % full scale Oxygen 0.01 ppm
Temperature + 0.005 C 0.1 % sat.
Sensor section
Cond. Salt Water + 0.007 mS/cm pH 0.001 pH
Cond. Fresh Water +5 S/cm Redox 0.1 mV

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 63 mm (2.5) Logging Speed: 3-6 m/min
Max. Hole Diameter: NA (590 - 1200 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


P in dbar Fluid Pressure
Temp in C Fluid Temperature
Cond in mS/cm or S/cm Fluid Conductivity
Ox in ppm or %sat Oxygen
pH pH
Redox in mV Redox

Combinability
none

ANTARES
ANTARES is continually updating and improving its high performance and2017 23
quality logging system and for this reason the specifications
are subject to change without prior notice.
Standalone Tool Product Line

Continuous Flowmeter

The ANTARES 1627 Continuous Flowmeter is run to monitor downhole fluid flow rates. Exchangeable
heads allow to choose a right diameter to optimize the measurement according to the borehole
diameter. The tool can determine between upward and downward flow direction.

Specifications
Diameter Sensors: Spinner
Electronics section: 42 mm (1.65)
Spinner: 45 mm (1.77") Measure points (from bottom):
(exchangable) 90 mm (3.54") 45 mm spinner 92 mm (3.62")
Length: 1,748 mm (68.8") 90 mm spinner 111 mm (4.37")
Weight: 8.5 kg (19 lbs)

Max. Temperature: 90 C (194 F)


Max. Pressure: 20 MPa (2,900 psi)

Max. Cable Length: 2,500 m (8,200 ft)


Cable requirements: mono or 4-conductors
Telemetry required: no
Data Transmission: digital

Top Connector: GO1, GC1, GO4 or GC4


Bottom Connector: none

Measuring Parameters
Measuring range
Flow: 0.008 m sec to 5 m/sec
depending on cage size
Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 70 mm (2.8") Logging Speed: max. 10 m/min
Max Hole Diameter: 250 mm (9.8") 1950 ft/hr
Sample Rate: selectable

Standard Displayed Curves


CHV in V Cable Head Voltage
TEMP in C/F Instrument Temperature
FlowRaw in cps Rotational speed of the flowmeter (w/direction)
Flow in rpm Calibrated rotational speed of the flowmeter (w/direction)
Combinability

Combinability
With 1495 GR Adapter on top

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

24 ANTARES 2017
Standalone Tool Product Line

High Resolution Temperature

The ANTARES 16N7 Temperature Instrument is used to determine temperature profiles with
resolutions of + 0.01 C and can detect even small changes in temperature.

Specification
Diameter 43 mm (1.69") Sensors:
Length: 1,005 mm (39.57") Temperature Pt 1000
Weight: 8 kg (18 lbs)
Measure points (from bottom)
Max. Temperature: 100 C (212 F) Temperature 20 mm (0.79")
Max. Pressure: 20 MPa (2900 psi)

Max. Cable Length: 2,500 m (8,200 ft)


Cable Requirements: mono or 4-conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GO1, GC1, GO4 or GC4


Bottom Connector: none

Measuring Parameters:
Measuring Range: -5 to 100 C (212F)
Accuracy: +0.2 C
Resolution: 0.01C

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 65 mm (2.6) Logging Speed: 6 m/min
Max. Hole Diameter: NA (900 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


Temp in C or F Temperature
CHV in V Cable Head Voltage
ETemp in C Electronics Temperature

Combinability
Application
none

Application

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 25
Standalone Tool Product Line

Fluid Sampler
ANTARES 0409 Fluid Sampler is designed to take fluid samples even under difficult borehole
conditions. Several tank sizes are availbale for the sample fluids and robust mechanism allows for
simple and trouble free operations.

Specification
Diameter Electronics: 42.4 mm (1.67") Sensors: Fluid Sensor
Fluid Sensor
Length Electronics: 800 mm (31.5")
Weight Electronics: 3.5 kg (8 lbs) Measure Points (from Top):
Fluid Sensor: 50 mm (1.97")
Max. Temperature: 70C (158F)
Max. Pressure: 20 MPa (2900 psi)
Electronic
Max. Cable Length: 2,500 m (8,200 ft) Section
Cable Requirements: mono- or
4-conductor
Telemetry required: no
Top Connector: GC1, GO1, GC4 or
GO4
Bottom Connector: none

Measuring Parameters: Sample


Point
Measuring Range NA
Resolution NA
Accuracy NA

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.7) Logging Speed: stationary
Max Hole Diameter: NA Sample Rate: NA

Displayed Standard Curves


CHV in V Cable Head Voltage
Sample
Chamber
Sample Chamber
No. of Sample Chambers: 1
Sample Point (from Top): 670 mm

Volume Diameter Length Weight w/o sample


1l 42.4 mm (1.67") 1110 mm (43.70") 4.7 kg (10 lbs)
3l 76 mm (2.99") 1180 mm (46.46") 11 kg (24 lbs)
5l 76 mm (2.99") 1680 mm (66.14") 14 kg (31 lbs)
5l 101.6 mm (4.00") 1157 mm (45.55") 15 kg (33 lbs)

Combinability
Application
none

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

26 ANTARES 2017
Combinable Low-Temperature Instruments
ANTARES offers a combinable string of nuclear instruments, which allows the measurement of GR,
neutron and density logs in just one run. The outer diameter of the string is only 43 mm and therefore,
it enables for measurements in very slim boreholes or casings. These tools can be run as standalone
or in combination.

The product line of ANTARES Telemetry low-temperature instruments comprises a set of tools, which
are run below a telemetry with Gamma Ray. These comprehensive low-temperature instruments
enable a high degree of flexibility. Several instruments can be combined in one string, reducing rig
time where every minute matters. These tools are designed according to oilfield standards and
measurements are accurate against the industry standards.

These tools have been field tested in offshore environments and proved their reliability and easy
handling ability. The pressure rating is up to 50 MPa (7,250 psi).

ANTARES 2017 27
Standalone Tool and Combinable Radioactive Tool Product Line

GR Adapter
The ANTARES 1495 GR Adapter can be added to several ANTARES Low Temperature instruments of
the Standalone Tools as well as on the Combinable Radioactive Tool Product line to add lithology and
depth determination information. The Gamma Ray Log can be ran in open and cased holes, in all mud
systems and in dry holes.

Specifications
Diameter: 42.4 mm (1.67") Sensors:
Length: 1,594 mm (62.8) NaI Scintillation Crystal
Weight: 8 kg (17 lbs)
Measure Points (from bottom):
Max. Temp: 90C (194F) 1,316 mm (51.8")
Max. Pressure: 20 MPa (2900 psi)

Max. Cable Length: 2,500 m (8,200 ft)


Cable Requirements: mono or 4-conductor
Telemetry required: no
Data Transmission: digital

Top Connector: GO4 or GC4


Bottom Connector: GO4 or GC4

Measuring Parameters:
Measuring Range: Accuracy:
GR: 0 to 3000 gAPI GR: + 5 % of measured values

Resolution:
GR: 3 API

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 65 mm (2.6) Logging Speed: 9 m/min
Max. Hole Diameter: NA (1800 ft/hr)
Sample Rate: selectable

Standard Displayed Curves

GR in API Gamma Ray


CHV in V Cable Head Voltage
TEMP in C Electronics Temperature

Combinability
With other tools from the ANTARES Standalone and Combinable Radioactive Tool Families.

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

28 ANTARES 2017
Standalone Tool and Combinable Radioactive Tool Product Line

Dual Detector Neutron


The ANTARES 29N8 Slim Dual Detector Neutron instrument works with a chemical source and two
neutron detectors made of Lithium-Glass. The source emits neutrons which are slowed down and
then captured, primarily by hydrogen atoms in the formation fluids. The detectors count the neutrons
deflected back to the tool. The ratio of the short space over the long space count rate is an indicator for
porosity, using the fact that the tool responds primary to the hydrogen content of the formation. The
tool is run standalone or in combination with GR Adapter 1495 (above) and Sidewalll Density
Instrument (below).

Specifications
Diameter: 38 mm (1.50") Sensors:
Length: 2,038 mm (80.7) Neutron Detectors:
Weight: 10 kg (22 lbs) Type: Lithium-Glass
No: 2
Max. Temp.: 90C (194F)
241
Max. Pressure: 20 MPa (2900 psi) Source: 3,7 GBq (100 mCi) AmBe
sideloaded
Max Cable Length: 2,500 m (8,200 ft)
Cable Requirements: 4-conductor Measure Points (from source):
Telemetry Required: no LS 372 mm (14.7")
Data Transmission: digital SS 172 mm (6.8")

Top Connector: GO4 or GC4 Accessories:


Bottom Connector: GO4 or GC4 Decentralizer

Measuring Parameters:
Measuring Range: Accuracy:
Count rate LS: 0 to 65535 cps + 5 % of the reading
Count rate SS: 0 to 65535 cps

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 63 mm (2.5) Logging Speed: 3-6 m/min
Max. Hole Diameter: 400 mm (15.8") (590 - 1200 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


SSN in cps Near detector counts from Short Space Detector
LSN in cps Far detector counts from Long Space Detector
SSN/LSN Count rate ratio (SSN/LSN)
CHV in mV Cable Head Voltage
Temp in C Temperature of Electronics

Combinability
With other tools of the Combinable Radioactive Tool Family

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 29
Standalone Tool and Combinable Radioactive Tool Product Line

Slim Sidewall Density


The ANTARES 29N9 Slim Sidewall Density instrument works with a Cesium source and two detectors.
From the energy spectrum and count rates of the two counters, the borehole compensated formation
bulk density can be estimated. The tool is run standalone or in combination with GR Adapter 1495
and/or Slim Dual Detector Neutron (above).

Specifications
Diameter: 38 mm (1.50") Detectors:
Length: 2,175 mm (85.6) Type: NaI Scintillation Crystal
Weight: 10 kg (22 lbs) No: 2

Max. Temp.: 90C (194F) Source: 3.7 GBq (100 mCi) 137Cs
Max. Pressure: 20 MPa (2900 psi)

Max Cable Length: 2,500 m (8,200 ft) Measure Points (from source):
Cable Requirements:4-conductor LS 622 mm (24.5")
(mono-conductor for SS 318 mm (15.0")
standalone version only)
Telemetry Required: no Accessories:
Data Transmission: digital Decentralizer

Top Connector: GC4 or GO4


(GC1 or GO1, standalone
version)
Bottom Connector: none

Measuring Parameters:
Measuring Range: Accuracy:
Count rate LS: 0 to 65535 cps +5 % of the reading
Count rate SS: 0 to 65535 cps

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 63 mm (2.5) Logging Speed: 3-6 m/min
Max. Hole Diameter: 400 mm (15.8") (590 - 1200 ft/hr)
Sample Rate: selectable

Standard Displayed Curves


SSN in cps Near detector counts from Short Space Detector
LSN in cps Far detector counts from Long Space Detector
SSN/LSN Count rate ratio (SSN/LSN)
CHV in mV Cable Head Voltage
Temp in C Temperature of Electronics

Combinability
With ANTARES 1495 GR and Dual Detector Neutron tools from the ANTARES Combinable
Radioactive Tool Family.

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

30 ANTARES 2017
Combinable Low-Temperature Tool Product Line

Telemetry / GR
The ANTARES 0921 Digital Telemetry instrument handles the communication between the ALADIN
surface system and ANTARES digital downhole instruments in both directions. It also monitors the
temperature of the telemetry electronics and the cable head voltage. The tool includes a Gamma Ray
scintillation detector, measuring the total gamma rays emitted by the surrounding formation. The
Gamma Ray Log (GR) can be ran in open and cased holes, in all mud systems and in dry holes.

Specifications

Diameter: 43 mm (1.69") Sensors:


Length: 1,326 mm (52.2") GR NaI scintillation crystal
Weight: 6 kg (13 lbs)
Measure Points (from bottom):
Max. Temp: 70C (158F) GR : 220 mm (8.7)
Max. Pressure: 50 MPa (7250 psi)

Top Connector: GO4 or GO7


Bottom Connector: ANTARES Toolbus

Measuring Parameters
Measuring Range: Accuracy:
GR: 0 to 3000 gAPI GR: + 5 % of measured values

Logging parameters

Recommended: Recommended:
Min. Hole Diameter: 70 mm (2.8") Logging Speed GR: 6 m/min
Max Hole Diameter: NA (2800 ft/hour)
Sample Rate: selectable

Displayed Standard Curves


GR in API Gamma Ray
CHV in V Cable Head Voltage
TEMP in C Electronics Temperature

Combinability
With all tools from the ANTARES Combinable Low-Temperature Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 31
Combinable Low-Temperature Tool Product Line

1489 Spectrum Gamma Ray


The ANTARES 1489 Spectrum Gamma Ray (SGR) is an instrument logging the natural gamma
radiation. The tool measures the entire gamma ray spectrum from 0 to 3000 keV. It records the total
amount of Gamma Rays and provides quantitative measurements of the 40Potassium, 232Thorium and
238
Uranium contents of the formation.
The Spectrum Gamma Ray Log can be run in open and cased holes with all mud systems and also in
dry boreholes.

Specifications
Diameter: 52 mm (2.05") Detector Type: BGO Scintillation Crystal
Length: 1,110 mm (43.7)
Weight: 9.2 kg (21 lbs)
Measure Point (from bottom):
Max. Temp: 60C (140F) 257.5 mm (10.1")
Max. Pressure: 50 MPa (5,800 psi)
Spectrum: 60...3000 keV,
Telemetry required: yes, type 921 or 924 256 Channels
Top Connector: ANTARES Toolbus
Bottom Connector: ANTARES Toolbus

Measuring Parameters:
Measuring Range: Accuracy:
GR 0...3000 APi GR + 3 % of measured
K 0...50 % values
U 0...500 ppm K, U, Th + 4 % of measured
Th 0...500 ppm values

Logging Parameters
Recommended Recommended
Min. Hole Diameter: 78 mm (3) Logging Speed: 3 m/min
Max Hole Diameter: NA 590 ft/hr
Sample Rate: selectable

Displayed Standard Curves


SGR in gAPI Gamma Radiation
K in % Potassium Content
Th in ppm Thorium Content
U in ppm Uranium Content
KTh Potassium plus Thorium Content
ChiSqr Chi-Square - a measure for the quality of the spectrum Stripping
result
RThK Ration between Thorium and Potassium Content
RThU Ration between Thorium and Uranium Content
RUK Ration between Uranium and Potassium Content

Combinability
With all tools from the ANTARES Combinable Low-Temperature Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
32 ANTARES 2017
Combinable Low-Temperature Tool Product Line

Dual Detector Neutron


The ANTARES 1494 Dual DetectorNeutron instrument works with an Americium Beryllium source
and two detectors. The source emits high energy neutrons, which undergo scattering in the forma-
tion, lose energy and produce gamma rays. The thermal neutrons are measured by the two detectors
in the tool. The tool can be run in both open and cased holes and in most types of mud. In order to
minimize the borehole effects, the tool is run decentralized.

Specifications
Diameter (max): 52 mm (2.05") Detectors:
Length: 1750 mm (68.9) Type: He-3
Weight: 30 kg (66 lbs) No: 2

Max. Temp: 70C (158F) Source: 130 GBq (3.5 Ci) 241 AmBe
Max. Pressure: 50 MPa (7,250 psi) side loadaed

Telemetry required: yes, type 921 or 924 Measure Points (from bottom):
Top Connector: ANTARES Toolbus CN: 547 mm (21.5")
Bottom Connector: ANTARES Toolbus

Measuring Parameters
Measuring Range: 0-100 % Porosity Accuracy: + 10 %

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.76) Logging Speed: 6 m/min
Max Hole Diameter: 250 mm (18) (1200 ft/hr)

Standard Displayed Curves


LSN in cps Long Space Detector Count Rate
SSN in cps Short Space Detector Count Rate
CN in % Uncorrected Porosity
Ratio Ration SSN/LSN

Combinability

With all tools from the ANTARES Combinable Low-Temperature Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 33
Combinable Low-Temperature Tool Product Line

Sidewall Density
The ANTARES 1491 Sidewall Density instrument includes a Cesium source and two detectors. From
the energy spectrum and count rates of the two counters, the borehole compensated formation bulk
density is calculated. A caliper measurement is provided, permitting compensation for borehole
effects. The tool can be run in any mud except in barite mud, which absorbs the Gamma Rays and
therefore affects the density reading heavily. A Correction Curve indicates the influence of the
borehole rugosity.

Specifications
Diameter (max): 53 mm (2.09") Detectors
Length: 2598 mm (102.3) Type: NaI Scintillation Crystal
Weight: 30 kg (67.5 lbs) No: 2

Max. Temp: 70C (158F) Source: 3,7 GBq (0,1 Ci) 137Cs
Max. Pressure: 50 MPa (7250 psi)
Measure Points (from bottom):
Telemetry required: yes, type 921 or 924 DEN: 258mm (10,16)
Top Connector: ANTARES Toolbus (depending on source activity)
Bottom Connector: ANTARES Toolbus Caliper 862 mm (33,94)

Measuring Parameters
Measuring Range: Accuracy:
DEN: 1-3 g/cm3 DEN 0.02 g/cm3
Caliper: 53-457 mm (18) (for 2 - 3 g/cm3 formation
density)

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.8) Logging Speed: 6 m/min
Max Hole Diameter: 457 mm (18) (1200 ft/hr)

Standard Displayed Curves


3
Density in g/cm Caliper Corrected Bulk Density
Correction in g/cm3 Compensated Density Correction
Caliper in mm or in Borehole Diameter

Combinability
With most tools from the ANTARES Combinable Low-Temperature Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
34 ANTARES 2017
Combinable Low-Temperature Tool Product Line

Acoustic Instrument
The ANTARES 1313 Borehole Acoustic instrument is designed for acquiring high-resolution, full-
wave acoustic data. One ceramic monopole transmitter emits the acoustic signal which is detected by
two ceramic receivers. During one logging run, the formation travelling time in the open-hole interval
and the cement bond log in the cased-hole section can be recorded.The log requires a fluid filled
borehole but is independent of the mud type.

Specifications
Diameter: 43 mm (1.69") Transmitter: Ceramic, monopole
Length: 3,865 mm (156) Sensors: Ceramic transducer
Transport Length: 2 sections array
max. 2,300 mm
Weight: 15 kg (23 lbs) Transmitter-Receiver Spacing:
T1-R1 : 932 mm (3 ft)
Max. Temp: 70C (158F) R1-R2: 305 mm (1 ft)
Max. Pressure: 50 MPa (7,250 psi)
Measure Points (from bottom):
Telemetry required: yes, type 921 or 924 Delta T 917 mm (36.1")
Top Connector: ANTARES Runtime Far 765 mm (30.1")
Bottom Connector: ANTARES Runtime Near 1,070 mm (42.1")

Measuring Parameters
Measuring Range: Accuracy
DT: 100-800 s/m DT*: + 3 s/m (+1s/ft)
(35-250 s/ft) * centralized tool in a 100 mm diameter
borehole

Logging parameters
Recommended Recommended
Min. Hole Diameter:68 mm (2.7") Logging Speed: 6-15 m/min
Max Hole Diameter: 400 mm (15.4") 1200- 3000 ft/hr

Displayed Standard Curves


DT in s/m Delta Time
Runtime Near in s Acoustic Travel Time Near
Runtime Far in s Acoustic Travel Time Far
TTI Integrated TravelTime
TraceNear in mV Trace Information Near
TraceFar in mV Trace Information Far
Vp in m/s Sound velocity
Temp in C Electronics Temperature

Combinability
With all tools from the ANTARES Combinable Low-Temperature Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 35
Combinable Low-Temperature Tool Product Line

Dual Laterolog

The ANTARES 1113 Slimhole Dual Laterolog instrument is designed for

Cable Head
GO4
measuring formation resistivities in boreholes with conductive borehole fluids.
The Dual Laterolog measures both the Deep (RLD) and the Shallow Laterolog
resistivity (RLS). A SP measurement is also provided.

Specifications

523 IsoSub
Diameter: 43 mm (1.69") Type: LL3
Length: 2,343 mm (92.2)

SP Electrode
Weight: 16 kg (35 lbs) Measure Points
(from bottom of 1113 DLL)):
Max. Temp: 70C (158F) Deep: 910 mm (35.8")

524 IsoSub
Max. Pressure: 50 MPa (7,250 psi) Shallow 190 mm (7.5")

Telemetry required: yes, type 921 or 924 (from bottom of 524 IsoSub)
Top Connector: ANTARES Toolbus SP 1,990 mm (78.4")
Bottom Connector: ANTARES Toolbus

0921 Telemetry
Measuring Parameters
Measuring Range: Accuracy:
DLL, SLL 0.2 to 40,000 Ohmm DLL 0.2 to 10,000 Ohmm: 2 %
SP -1000 mV to 1000 mV SP 1 to 40,0000 Ohmm: 10 %

Intergrated IsoSub
Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.76) Logging Speed: 25 m/min
Max. Hole Diameter: 250 mm (9.84) (1200 ft/hr)

Displayed Standard Curves


1113 Laterolog
RLD in Ohmm Resistivity Laterolog Deep
MP Deep

RLS in Ohmm Resistivity Laterolog Shallow


SP in mV Spontaneous Potential
(four conductor cable only)
MP Shallow

IsoSubs required
0523 IsoSub w/ SP Length: 2,002 mm (78.82")
590 IsoSub

0524 IsoSub Length: 2,000 mm (78.74")


0590 IsoSub Length: 594 mm (23.39")

Combinability
With most tools from the ANTARES Combinable Low-Temperature Tool Product Line
Instrument
Further

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

36 ANTARES 2017
Combinable Low-Temperature Tool Product Line

4-Arm Caliper
The ANTARES 1005 4-Arm Caliper tool is a motorized instrument. All four arms provide individual
measurements. The four caliper signals are generated by using high-resolution precision magnetic
sensors and cover a range between 52 and 800 mm (2.0 and 31.5 inch). From the four independent radii
measurements an average borehole diameter and X - Y average diameters can be calculated.

Specifications
Diameter: 52 mm (2.05") Sensors: Magneto Resistivity
Length: 2,177 mm (85.7) Angle Sensors
Weight: 15 kg (123 lbs)
Measure Points (from bottom):
Max. Temp: 80C (176F) 77 mm (3.0")
Max. Pressure: 50 MPa (7250 psi)

Telemetry required: yes, type 921 or 924


Top Connector: ANTARES
Bottom Connector: ANTARES

Measuring Parameters
Measuring Range: Accuracy:
Cal: 52-800 mm + 2% (0.08")
(2.1-31.5")
Resolution:
0.1 mm (0.004")

Logging parameters
Recommended Recommended
Min. Hole Diameter:75 mm (3.0") Logging Speed: 6-15 m/min
Max Hole Diameter: 800 mm (31.5") 1200- 3000 ft/hr

Displayed Standard Curves


Rad1, Rad2, in mm or inch Measured radii in four directions
Rad3, Rad4
Cal13, Cal24 in mm or inch 2-axis Caliper from radii
Caliper in mm or in Average Borehole Diameter

Combinability
With most tools from the ANTARES Combinable Low-Temperature
Tool Product Line

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 37
Cavern and Low-Temperature Cased-Hole Logging

ANTARES designed a set of instruments for cavern and low-


temperature cased hole logging. The applications comprise
detection of the shape of the cavern, interface measure-
ments, but also the determination of casing collar locators
and the orientation of boreholes.

In dual string casings, CCLs of both casings can be


detected in addition to the deviation and fluid tempera-
ture by the ANTARES 1509 instrument.

Water table to be detected by


blanket instruments with
neutron generator or che-
mical source.

Three-dimensional measure-
ment and shape determination
of an underground cavern. The
ANTARES DSC instrument has
been accepted by international
mining companies and Euro-
pean mining authorities.

Further cased hole instruments for applications in all temperature ranges you will find in our catolog
Cased hole instruments.

38 ANTARES 2017
Cavern and Low-Temperature Cased Hole Tools

Directional Sonar Caliper


The ANTARES Directional Sonar Caliper (DSC) is a digital ultrasonic measurement system for cavern
survey. The data collected by the system allow for georeferenciated interpretation and to record the
three-dimentional shape of underground caverns filled with salt brine. With the tilting arm also the
ceiling of the cavern can be accurately detected. The integrated Dual String Collar Locator (DSCL)
allows to survey through two casing strings up to 13 3/8 diameter.

Specifications
Diameter: 72 mm (2.83") Top Connector: GC4
Length: 3,600mm (142) Bottom Connector: none
Transport Length: max. 2000 mm (79")
Weight: 60 kg (133 lbs) Sensors:
Transducers 2 piezo ceramic

temperature sensor
Max. Temp: 70 C (160F) Magnetometer
Gyro 50C (120F) Inclinometer

velocimeter and
Max. Pressure: 30 MPa (4,350 psi) Velocimeter
Gyro
Max Cable Length: 2,500 m (8,200ft) Dual string collar locator (DSCL)
Cable requirements: 4-conductor Temperature
Telemetry required: no Pressure
Data transmission: digital

Measuring Parameters

electronics
Measuring range: Accuracy:

main
Caliper (open cavern): 2 to 200 m Caliper: 0.018 m + 0.09 %
Caliper (1 pipe): 2 to 67 m of the distance
Caliper (2 pipe): 2 to 60 m Beam Width : 1.0 (-3 db)
(depending on the concentricity of Side-Echo: q-20 db of the main

transportation
breakpoint for
pipes and physical conditions) echo
Acoustic frequencies: 250...750 kHz Pressure: 0.1 MPa
Fluid sound velocity: 1300-1900m/s Temperature: 0.1C
Azimuth: 0-360 Fluid velocity: <2m/s
Inclination: 0-30
Pressure: 0-40 Mpa Resolution:
Temperature: 0-85 C Caliper: 0.1 m
DSCL: 2 strings of Azimuth: 1
casing Inclination: 0.5
Pressure: 0.01 MPa
fluxgate

Temperature: 0.01 C
gyro

Fluid velocity: 0.1 m/s


Logging parameters
Recommended Recommended
Min. casing diameter DSCL: 95 mm (3.7") Logging speed DSCL: 3 to 15 m/min
Max. casing diameter DSCL:300 mm (11.8") Logging speed DSC: NA, stationary
Min. cavern radius: 2m (78.7")
Max. cavern radius: 200 m (656 ft)

Displayed Standard Curves


Available Curves
DSCL Dual Collar Locator Azimuth in deg Direction Tool High Side
transducer

P in MPa or psi Borehole Pressure referenced to North


T in C Borehole Temperature Deviation in deg Deviation of the borehole
section

Vf in m/s Fluid velocity referenced to Vertical


Caliper in m Distance caliper

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
ANTARES 2017 39
Directional Sonar Caliper

Application

The main application of the Directional Sonar Caliper log is the determination of the shape of the
cavern. The log data can be exported to 3rd-party software to visualize the position and shape of it.
ALADIN aquisitions and

Processing
procession system

at Customer
(3D-Processing
Software
Package)

Function Overview

Ground

4. Measurement through the casing


3. Measurement of the cavern top
2. Measurement of the open cavern
1. Measurement of the cavern
bottom.

single shot 360 scan


4
step angel

Instrument function
3
The configuration of the tool with a tilting arm and
2
two transducers scanning different directions
1 Measurement
allow the client to produce 3-dimentional figures
principle
of caverns.

ANTARES is continually updating and improving its high performance and quality logging system and for this reason the specifications
are subject to change without prior notice.
40 ANTARES 2017
Cavern and Low-Temperature Cased Hole Tools

1509 DSCL/GR/TEMP

With the ANTARES 1509 DSCL-Gamma Ray-Temperature-Deviation Instrument , CCLs of both


casings can be detected in dual string casings in addition to the deviation of the well and the fluid
temperature. The gamma ray allows for accurate depth correlation.

Specification
Diameter 73 mm (2.87) Sensors:
Length: 2900 mm (114.17") Temperature
Weight: 30 kg (66 lbs) DSCL
Gamma Ray
Max. Temperature: 70 C (158 F) Inclination
Max. Pressure: 60 MPa (8,700 psi)

Max Cable Length: 2,500 m (8,200 ft)


Telemetry required: no
Cable requirements: 4-conductors
Data Transmission: digital

Top Connector: GC4 or GO4


Bottom Connector: none

Measuring Parameters
Measuring range Accuracy
Temperature 5 to 70C Temperature + 0.1 C
(41 to 158F) GR + 3 % of
GR 0 to 10,000 cps measured values*
0 to 3,000 gAPI DSCL NA
DSCL two strings of Deviation: + 1
casing
Deviation: 0...20 deg Resolution
Temperature 0.01 C

Logging parameters

Recommended: Recommended:
Min. Casing Diameter: 100 mm (4") Logging Speed: 10 m/min
Max. Casing Diameter: NA
Sample Rate: selectable

Standard Displayed Curves


CHV in V Cable Head Voltage GR in cps or gAPI Gamma Ray
TEMP in C/F Instrument Temperature Deviation in deg Deviation of the borehole
BHT in C/F Borehole Temperature referenced to Vertical
DSCL Dual Collar Locator

Combinability
Application
none

ANTARES is continually updating and improving its high performance and quality logging system and instruments. For this reason the
specifications are subject to change without prior notice.
ANTARES 2017 41
Cavern and Low-Temperature Cased Hole Tools

Pulsed Neutron Blanket

The 1463 Pulsed Neutron Blanket Instrument is designed to detect the location of the brine-
hydrocarbon-interface in salt caverns. The instrument contains a neutron generator and a gamma ray
detector. The number of detected Gamma Rays depends on the neutron capture cross-section of the
medium. As brine has a much higher capture cross-section than hydrocarbons, the interface is easily
detected. The tool is also equiped with a Casing Collar Locator and a temperature sensor.

Specifications

Diameter: 43 mm (1.69") Source:


Length: 3,397 mm (156) Type: Neutron Deuterium
Transport Length: 2 sections with Tritium target
Weight: 20 kg (123 lbs) Firing frequency: 0-20 Hz
Neutron output: 1x108n/s
Max. Temp: 70C (158F) Neutron length: 10-6 s
Max. Pressure: 20 MPa (2900 psi) Average Lifetime 100 Hrs @
10 Hz firing rate
Max Cable Length: 2,500 m (8,200 ft)
Telemetry required: no Sensors:
Cable requirements: mono or 4-conductors GR Detector: NaI
Data Transmission: digital CCL
Temp. Sensor: Pt1000
Top Connector: GC1, GO1, GC4 or GO4
Bottom Connector: none Measure Points (from bottom):
CCL 3,202 mm
Gamma Ray: 1,832 mm
Borehole Temp.: 50 mm

Measuring Parameters
Measuring Range: Accuracy
Blanket counter: 0-50000 cts/sec Blanket: + 5% of measured
Temperature: 0 - 80C values
CCL: one strings of Temperature: + 1C
casing CCL NA

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.8") Logging Speed: 9 m/min (1800 ft/hr )
Max Hole Diameter: 300 mm (15.7")

Displayed Standard Curves


CHV in mV Cable Head Voltage
ETemp in C or F Electronics Temperatur in
Gate 1 in counts/sec Gamma rays Gate 1
Gate 2 in counts/sec Gamma rays Gate 2
CCL in mV Casing Collar Locator
Temp in C or F Borehole Temperature

Combinability
none

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

42 ANTARES 2017
Cavern and Low-Temperature Cased Hole Tools

Pulsed Neutron Blanket/DSCL

The ANTARES 1464 Pulsed Neutron Blanket Instrument is designed to detect the location of the
brine-hydrocarbon or brine-air interface in salt-caverns. The instrument contains a neutron
generator and a gamma ray detector. The number of detected Gamma Rays depends on the
neutron capture cross-section of the medium. As brine has a much higher capture cross-section
than hydrocarbons, the interface is easily detected. The tool is also equiped with a Dual String
Casing Collar Locator (DSCL) and a temperature sensor.

Specifications
Diameter: 43/44 mm (1 11/16") Source:
Length: 3,858 mm (156) Type: Neutron Deuterium
Transport Length: 2 sections with Tritium target
Weight: 20 kg (123 lbs) Firing frequency: 0-20 Hz
Neutron output: 1x108n/s
Max. Temp: 70C (158F) Neutron length: 10-6 s
Max. Pressure: 20 MPa (2900 psi) Average Lifetime 100 Hrs @
optional 30 MPa (4300 psi) 10 Hz firing rate

Max Cable Length: 2,500 m (8,200 ft) Sensors:


Telemetry required: no GR Detector: NaJ
Cable requirements: mono or 4-conductors DSCL
Data Transmission: digital Temp. Sensor: Pt1000

Top Connector: GC1, GO1, GC4 or GO4 Measure Points (from bottom):
Bottom Connector: none DSCL 3,510 mm
Blanket Counter: 2,108 mm
Borehole Temp.: 50 mm

Measuring Parameters
Measuring Range: Accuracy
Blanket counter: 0-50000 cts/sec Blanket: + 5% of measured
Temperature: 0 - 80C values
DSCL: two strings of Temperature: + 1C
casing DSCL NA

Logging parameters
Recommended Recommended
Min. Hole Diameter: 70 mm (2.8") Logging Speed: 9 m/min
Max Hole Diameter: 300 mm (15.7") 1800 ft/hr

Standard Displayed Curves

Combinability
none

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

ANTARES 2017 43
Cavern and Low-Temperature Cased Hole Tools

DSCL/Temperature/Gamma Blanket
The ANTARES 1466 Gamma-DSCL-Temperature is Blanket instrument designed to detect the fluid
interfaces in salt caverns and simultaneous performing high-precision temperature measurements.
The Dual String Collar Locator (DSCL) sensor can distinguish between collars of the outer and inner
casing strings.

Specification
Diameter 44.5 mm (1.75") Source:
Length: 2,464 mm (118.3") Type: 3.7 to 11.1 GBq 137Cs
Weight: 15 kg (28 lbs) (0.1 to 0.3 Ci)

Max. Temperature: 70 C (158 F) Sensors: DSCL


Max. Pressure: 35 MPa (5,000 psi) GR-S Scintillation Cristal
Temperature Pt 1000
Max cable length: 2,500 m (8,200 ft) DSCL Dual String Collar
Cable Requirements: Single-Conductor Locator
Telemetry required: no
Data Transmission: digital Measure points (from bottom):
GR 445 mm (17.5")
Top Connector: GO1,GC1, GC4 or GO4 Temperature 155 mm (6.1")
Bottom Connector: none DSCL 2,290 mm (90.2)

Measuring Parameters
Measuring range Accuracy
Temperature: -5 to 80 C Temperature: + 0.5 C
Gamma Ray: 0 to 65535 cps GR: +/- 5 % of measured
DSCL two strings of values
casing
Resolution
Temperature: 0.05 C

Logging parameters
Recommended Recommended
Min. Hole Diameter: 69 mm (2.5") Logging Speed: 25 m/min
Max Hole Diameter: NA 5000 ft/hr

Standard Displayed Curves


GR in cps Total Gamma Ray
GRI i n cps Gamma Ray Interface
BHT in C or F Borehole Temperature
BHTDiff in C or F Differential Borehole Temperature
DSCL in mV Dual Casing Collar GR
CHV in mV Cable Head Voltage

Combinability
Application
TEMP
none
Source
Holder

ANTARES is continually updating and improving its high performance and quality Logging system and for this reason the specifications
are subject to change without prior notice.

44 ANTARES 2017
Low Temperature Instruments

Furthermore available

The following instruments are available at ANTARES as well. Data sheets will be published soon.

Standalone Tool Product Line

Instruments Tool ID OD Tmax.


Fluid Density
with Temp/Press/CCL 1617 43 mm 70C
with Temperature 1626 43 mm 70C
with Temperature and Salinity 1666 60 mm 70C
SP 1149 43 mm 90C

Combinable Low-Temperature Tool Product Line

Instruments Tool ID OD Tmax.


Orientation Temp 1208 43 mm 70C

Research and Development is the key feature for ANTARES. Therefore, we are able to enlarge our
product line continuously and will come up with several new tools each year.

Please contact info@antares-geo.de for detailed information

ANTARES 2017 45
Surface System
The ANTARES Log Acquisition and Data Interpretation System (ALADIN) is very user friendly.It
comprises a modular 'plug-and-play' panel system and a modular software called GEOBASE. ALADIN
is exceptionally versatile and provides the user with a true multi-tasking logging environment.

SURFACE PANELS

The 'standard' panel system consistsof an


- Interface Panel with a
- Power Supply

Depending on the power requirements of the


tools, the power supply is either integrated in
the Interface Panel or it is a separate panel.

Optional peripheral equipment can simply be


added as 'plug-and-play' modules, e.g.
- Perforating Panel,
- Well Head Potential Monitor,
- Safety Switch and
- Winchman Panel with depth,tension and
speed information

A PC connected to the Interface Panel


completes the system, where the data can be
graphically displayed on screens and printers in
'real time'.

GEOBASE SOFTWARE

The software package GEOBASE


can be used on any computer with
a 32-bit or a 64-bit Windows ope-
rating system such as Microsoft
Windows 7, 8 or 10.

GeoBase Software Features:


- User friendly and simple
- Software set-up guides the
logging engineer
- Just 7 clicks and the data
recording can start
- Plug and play system
- Real time display of the data

46 ANTARES 2017
Contacts
Contacts

Headquarters North America and Mexico

ANTARES Datensysteme GmbH ANTARES USA


Rudolf-Diesel-Str. 6 4503 Spring Cypress Road, Suite C-5
28816 Stuhr 77388 Spring
Germany United States

Phone +49 (0) 421 87194 0 Phone +1 281 288 0658


Email info@antares-geo.de Email info@antares-usa-ltd.com

Conrad Blumhagen Steve Michell


Business Development Director President
Email c.blumhagen@antares-geo.de Email shmichell@antares-usa-ltd.com

Dr. Martina Bachmann


Business Development Manager Middle East and Africa
Email m.bachmann@antares-geo.de
ANTARES Datensysteme GmbH
Bayoumi Nassar Street
LogIn Bohrlochmessgerte GmbH Heliopolis 11351
Cairo, Egypt
LogIn Bohrlochmessgerte GmbH
Industriepark I, Strae B Nr. 2 Phone +202 2634 1137
39245 Gommern Email info@antares-geo.de
Germany

Phone +49 (0) 39200 729 0 Amr Morsy


Email info@logingmbh.de Business Development Manager
Email a.morsy@antares-geo.de
Ingo Reek
Managing Director
Email i.reek@logingmbh.de

ANTARES 2017 47
One System - One Supplier - One Contact

Dont forget to visit our website.


There, you will find several other products to complete your borehole logging equipment.

www.antares-geo.de

Logging Units Logging Software ANTARES Panel Downhole


GeoBase System Instruments

ANTARES 2017
ANTARES Datensysteme GmbH
Rudolf-Diesel-Str. 6
28816 Stuhr
Germany
Phone: +49 (0) 421 87194-0
Fax: +49 (0) 421 87194-25
Email: info@antares-geo.de
Version1/2017 Web: www.antares-geo.de

Anda mungkin juga menyukai