FOOTING CALCULATION

FOOTING ID Spacing ALONG Z ALONG X


FOOTING MARK F1 Main Bars 185 270 mm
Quantity 1 Number of Bar 11 8 PCS

DESIGN PARAMETERS FOOTING DIMENSION


Concrete Strength, f'c (MPa) 28.00 dimension of footing along X, Lx(mm) 2000
Main Reinforcement Yield Strength, f y (Mpa) 414.00 dimension of footing along Z, Lz(mm) 2000
Unit Weight of Concrete (kN/m3) 23.50 dimension of column along X, Cx(mm) 400
Main bar diameter, m (mm) 16 dimension of column along Z, Cz(mm) 400
Thickness of footing, t (mm) 300
DESIGN LOADS Concrete Cover, cc (mm) 75
Ultimate axial Load (KN) 261.097 Type of footing CORNER AT ONE SIDE ALONG X
Ultimate moment at X (KN.m) 0 Depth d (mm) 217
Ultimate moment at Z (KN.m) 0 Shear strength reduction factor 0.85
Ultimat pressure (Kpa) 65.27

CALCULATION
410.3.7.3 Compressive Block depth 1 = 0.85 CD ratio X 4.27 ok
WIDE-BEAM SHEAR
409.4.2 Shear Strength Reduction Factor s = 0.9 CD ratio Z 4.27 ok
408.7.1 Modification Factor for Normal Conc. = 1.0 along x
Vu=quxAv 76 KN
Steel Ratio Allowed by the Code Vc=1/6*sqroot(f'c)Bxd 383 KN
rb = 0.85*b 1*(f'c/fy)*[600/(600+fy)] b = 0.02891 Vu=Vc 325 KN
rmax 0.75*rb max = 0.02169 along x
Eq. 410.3 rmin =sqrt(f'c) / 4fy min = 0.00320 Vu=quxAv 76 KN
Eq. 410.3 rmin =1.4fy min = 0.00338 Vc=1/6*sqroot(f'c)Bxd 383 KN
Adopt min use min = 0.00338 Vu=Vc 325 KN

PUNCHING SHEAR CD ratio 2.21 ok


Bo=perimeter of shear 1634 mm
DEMAND LOADS Vu=quxAp 241 KN
Mx Mz Vc=1/3sqrt(f'c)Bod 625 KN
Moment Demand Mudem = 167.10 41.78 kN.m Vu=Vc 532 KN

REINFORCING BAR
ALONG Z ALONG X Required main bars spacing ALONG Z ALONG X
Depth of Compressive block Depth (mm) 217.00 217.00 As=bd 2160.23 1467.63 mm2
S1=Ab/As 186.15 273.99 mm
Compute the required steel ratio Smax= 3h 900 900 mm
Rn=(Mu)/(bd2) 1.97147 0.49287 Smax= 450 450 450 mm
=(0.85f'c/fy)(1-sqrt(1-(2Rn)/(0.85f'c)) )) 0.00498 0.00120 Adopt critical Spacing 186.15 273.99 mm
Adopt steel ratio = 0.00498 0.00338 Design critical Spacing 185 270 mm

END OF CALCULATION