Anda di halaman 1dari 12

Plot Details (Table C)

Proposal Details (Table A)


Plot Abutting Details (Table B)
BP No.
North N
J.E. Name
South S
D.E. Name
East E
Case Type New
West W
Proposal Type Residential
Project Details (Table D)
Architect Name
Owner/s Name
Village Name
PAH Name
S.No
NON CONGESTED changed to
Hissa No Location
NON-CONGESTED
City Serv. No
Area Zone R1
Land Mark
TDR Receiving
Plot No. D
Zone
TDR Genrating
D
Zone

Plot Details(Table 2)
Area From Document (Table 2a)
No. Form Area
1 7/12 Extract 500000.00
2 Property-Card 500000.00
3 Demarcation 0.00
4 Area as per site 0.00
5 Area as per POA document 500000.00
6 Others 50000.00
7 Area as per Drawing 501.651

Minimum area of Plot Considered : 501.651

Table 2b
Plot PLOT
Building Land Use Residential
Building Sub Use Residential
Rule Applicability Low Rise
Gross Plot Area (Minimum) 501.65
Deductions (from Gross Plot Area) 0.00
- Road Setback Area (RW) 0.00
- Proposed Road Area (DP) 0.00
- Reserve Area { } 0.00
- NDZ Area 0.00
- Area not in Possession (Encroached) 0.00
- Others (Nala, Well) 0.00
(A) Balance Plot Area 501.65
Deductions for 0.00
- Amenity Space 0.00
(B) Balance Plot Area 501.65
Deductions for 0.00
- Recreational Ground 0.00
- Internal Road Area 0.00
(C) Net Plot Area (Net Developable Area) 501.65
Additions (to Net Plot) 0.00
- Recreational Ground 0.00
- Internal Road Area 0.00
- NDZ Area 0.00
- Road Benefit For Layout Road 0.00
- Other (Reserve Area etc.) 0.00
(D) Total Area (Net PA + Additions) 501.65

Table 2c
Perm. FSI 1.0000
Perm. B/UP Area 501.65
Add : TDR AREA 0.00
: Special Cases FSI 0.00
: Road Setback Area (RW) 0.00
: Proposed Road Area (DP) 0.00
Total Perm. B/UP Area 501.65
Total Permisiable FSI Factor 1.0000
Proposed Floor (B/Up) Area 491.04
Sub Structure Area Addition(For FSI) 0.00
Sub Structure Area Deduction(For FSI) 0.00
Excess Balcony 0.00
Existing B/UP Area 0.00
Surrendered Area 0.00
Total B/UP Area 491.04
Consumed FSI (Factor) 0.9788

Plot Level Checking (Table 3)

Amenity (Layout) Check (Table 3a)

Amenity Space check Not Required

Recreational ground Checks (Table 3b)

Recreational Ground check Not Required (Min PA < 2000.00).

Proposed Internal Road Checks((Table 3c)

No Road Detected

PathWay Checks (Table 3d)

No Road Detected
Accommodation Reservation Details (Table 3e)

Plot Not Under Accommodation Reservation

Reserve Area Details

No Reserve Area Found.

Miscellaneous Checks

All Miscellanies checks are as per the rules.

Building Details (Table 4)

Height Details (4a)

Total Height (Table 4a-1)


Height
Building Status
Perm Prop
A (BLDG) 18.00 9.00 OK

Floor Height Check (Table 4a-2)

None of the Floors Fail in Height

Basement Floor Height Check Above Ground Level (Table 4a-3)

No Basement Floors Found

Loft Height From Floor (Table 4a-4)

None of the Lofts Fail in Height

Floor Number Check (Table 4a-5)


No. of Floors Considering Regular Plot.
Building Status
Perm Prop
A (BLDG) P+6 P+3 OK

Coverage Check (Table 4b - 1)


Permissible Proposed Status
250.83 155.46 OK

Basement Coverage Check (Table 4b - 2)


Permissible Proposed Status
250.83 0.00 OK

FSI & Tenement Details (Table 4c-1)


No. of Proposed Bal
Cover Open Lift
Building Same FSI Area Stair Pass Tnmt
Terr Terr Well
Bldg Resi. Resi.
Added
in FSI
A (BLDG) 1 491.04 65.18 63.72 0.00 62.73 3.24 7.29 11
Grand Total 1 491.04 65.18 63.72 0.00 62.73 3.24 7.29 11

Building : A (BLDG)
Proposed Cover
FSI Area Terr Open Lift
Floor Name Stair Pass Tnmt
Added Terr Well
Resi. in FSI
Third Floor... 139.978 18.718 0.002 15.682 0.000 2.430 03
Second Floor... 175.530 22.500 0.000 15.682 0.000 2.430 04
First Floor... 175.530 22.500 0.000 15.682 3.240 2.430 04
Parking Floor... 0.000 0.000 0.000 15.682 0.000 0.000 00
Total : 491.04 63.72 0.00 62.73 3.24 7.29 11
Total Number of Same Buildings : 1
Grand Total : 491.04 63.72 0.00 62.73 3.24 7.29 11

Table 4c-2
FSI Area
Sub 501.65 491.04 OK
:0.00
Residential: 491.04 Structure
Permissible Proposed Status
Commercial: 0.00 Existing:0.00
Industrial: 0.00 Excess
:0.00
Special: 0.00 Balcony
Refuge Area:0.00

Margin Checks (Table 5)


Plot Margin (Table 5a) Considering Regular Plot
Front Side Rear Side Side1 Side Side2 Side
Building / Wing Bldg Height Status
Req. Prop. Req. Prop. Req. Prop. Req. Prop.
A-1 (BLDG) 9.00 4.50 4.50 3.00 3.00 3.00 3.00 3.00 3.09 Ok

Front Margins for Roads


Road Name 1.50 m Shifted Plot boundary
Front Side Status
Building / Wing
Req. Prop.
A-1 (BLDG) 4.50 4.50 Ok

Building To Building Margin Check (Table 5b)

Building To Building Margins check not Required (Single Building)

Other Margin Check (Table 5c)

Other Margin Checks are OK


Sitout to PlotBoundary Margin Check (Table 5d)
Building Reqd Prop Status
A-1 (BLDG) 3.00 3.00 OK

Margin from Physical Features Check (Table 5e)

No Physical Feature(Railway Line, Electric Line etc.) Found

Podium To PlotBoundary Margin Check (Table 5f)

No Podium Found Inside PlotBoundary

Inner Building Details (Table 6)


Inner Chowk Details (Table 6a)

No Inner Chowks Found

Ventilation Shaft Details (Table 6b)

For Building : A (BLDG)

All VShafts are as per rule.

Balcony Check (Table 6c)

Width of All Balcony(s) are as per the Rules.

Passage Detail(Table 6d)

For Building : A (BLDG)

All Passages of this Building are as per the Rules

Lift Details (Table 6e)


Number Of Lifts Lift Width Lift Length
Building Height Status
Reqd Prop Reqd Prop Reqd Prop
A (BLDG) 11.95 NA 1 - 3.15 - 3.15 OK

Terrace Details (Table 6f)


Width of all the Terraces in the Building(s) are as per the Rules.

Tenements Details (Table 6g)


Tenements
Building Residential
0 - 80 80 - 150 > 150 Total
A-1 (BLDG) 11 0 0 11
Grand Total 11 0 0 11

Tenements Density Check


No Of Tenements Perm Proposed Status
For Plot 250.00/Hec. 13 11 OK
Parking Details (Table 7)

Required Parking From Rules (Table 7)


Carpet/FSI Tenements(Car) Car Scooter Cycle
Type Area(Car)
Unit Prop Req/Unit Req Req/Unit Req Req/Unit Req
(m2)
0 - 80 2 11 1 6 4 22 4 22
Residential 80 - 150 1 0 1 0 2 0 2 0
> 150 1 0 2 0 2 0 2 0
Total : : - - 6 - 22 - 22
Unit : : - - x12.5 - x3.0 - x1.4
Total Area
- - 75.00 - 66.00 - 30.80
::

Parking Check (Table 7a)


Required Proposed
Parking Type Status
Nos Area Nos Area
Total Cars 6 75.00 8 100.00 OK
SC 22 66.00 22 66.00 OK
CY 22 30.80 22 30.80 OK
Total Vehicles - 171.80 - 196.80 OK

Available Parking Area in Layout (Table 7b)


Available Open Area in Permissible Parking Area in Proposed Parking Area
Required Required in Required Status
Side & Rear Margin Side & Rear Margin(50%) Side & Rear Margin
168.84 84.42 33.80 OK

Available Covered Parking Area (Table 7c)


Available Covered Parking Area Proposed Covered Parking Area Status
200.86 163.00 OK

Loading Unloading Checks (Table 7d)

Loading Unloading Checks Not Required.

Sanitation Details (Table 8)


Sanitation Check (Table 8a)

Sanitation Checks are not required.

Tank Calculation (Table 8b)

Total Water Requirement


Water Requirment
Water Required Proposed
Requirment Status
Tank Capacity (lit) Capacity (lit)
Residential 7425.00
Over Head Fire 0.00
Total 7425.00 14458.50 OK
1.5 times 11137.50
Under
Fire 0.00
Ground
Total 11137.50 20000.00 OK

Building : A (BLDG)
Water Requirment
OCCUPANT LOAD Required Proposed
Water Consumtion
Requirment (nos) Capacity Capacity Status
Tank per day (lit)
Tnmts/Area Factor (lit) (lit)
Residential 11 5 55 135 7425.00
Over
Fire 0.000
Head
Total 7425.00 14458.50 OK

Exemption Details (Table 9)


Staircase Checks (Table 9a)

Stair Number Check


Number Of Common Stairs Number Of Fire Stairs
Building Status
Reqd Prop Reqd Prop
A (BLDG) 1 1 NA - OK

All Travel Distances are as per the Rules.

A (BLDG)

Width of all the Stairs on this Building are as per the Rules

Subsidiary Structure Check (Table 9b)


Allowed in Area
Area Size
Name Margin Considered Status
Reqd Perm Prop Reqd/Perm Prop Front Rear Side in FSI
1.50
RAIN WATER
NA NA 2.25 - X YES YES YES No OK
HARVESTING
1.50

Distance
Distance Distance Distance
From
From From From
Name Plot Status
Main Road Building SubStructure
Boundary
Reqd Prop Reqd Prop Reqd Prop Reqd Prop
RAIN WATER
- - - - - - - - OK
HARVESTING
Rain Water Harvesting Provided.

Ramp Checks (Table 9c)

No Ramps Found.

Arch Projection Checks (Table 9d - a)

For Building : A (BLDG)

All arch projections are as per rules

Refuge Area Checks (Table 9e)

For Building : A (BLDG)

No RefugeArea Required.

Floor Details (Table 10)


Misc Checks (Table 10a)

Building : A (BLDG)

Floor : FIRST FLOOR PLAN

Dimensions and Area of all the Rooms on this Floor are as per the Rules

Floor : PARKING FLOOR PLAN

No Room Found.

Floor : THIRD FLOOR PLAN

Dimensions and Area of all the Rooms on this Floor are as per the Rules

Floor : SECOND FLOOR PLAN

Dimensions and Area of all the Rooms on this Floor are as per the Rules

Carpet Details (Table 10b)


Enc Open
Building Carpet Carpet Terrace
Floor Name Balcony Balcony
Name Name Area Area
Area Area
101 37.85 0.00 7.56 0.00
FIRST FLOOR 102 34.91 3.28 7.47 0.00
PLAN 103 32.60 0.00 3.69 3.78
A (BLDG) 104 29.95 15.30 3.78 3.78
301 37.85 0.00 7.56 0.00
THIRD
302 34.91 3.28 7.47 0.00
FLOOR PLAN
303 32.60 5.85 52.47 3.78
201 37.85 0.00 7.56 0.00
SECOND 202 34.91 3.28 7.47 0.00
FLOOR PLAN 203 32.60 0.00 3.69 3.78
204 29.95 15.30 3.78 3.78

Charges Details (Table 11)

Total Premium Calculation (Table 11a)


Premium Entity Factor/Area
Gross Plot Area 501.65
Special Use Premium Area 0.00
Lift Machine Area 9.92

Premium Calculation per Building (Table 11b)


Prop. FSI + Excess Lift +
Building Height Balcony
Balcony Staircase Passage Lift Terrace
/ Wing
- RESI. Comm. Ind. Spec. RESI. Comm. Ind. Spec. Mach.
A-1
9.00 491.04 0.00 0.00 0.00 46.28 0.00 0.00 0.00 62.73 7.29 13.16 0.00
(BLDG)
Total - 491.04 0.00 0.00 0.00 46.28 0.00 0.00 0.00 62.73 7.29 13.16 0.00

Detail Information (Table 12)

Coverage Details (Table 12a)


Building / Wing Coverage Area
A-1 (BLDG) 155.46

Other (Sub Structure, etc.) 0.00


Total 155.46

Other Details (Table 12b)


Balcony Calculation (15% of Total Lift
Building / Balcony Type
Builtup Area) Machine
Wing
Permissible Proposed Excess Enclosed Open Room Area
A-1
73.66 65.18 - 46.28 18.90 9.92
(BLDG)
Total 73.66 65.18 0.00 46.28 18.90 9.92

Summary (Table 13)

Name Perm./Reqd. Proposed Status


Plot Area 125.00 501.65 Ok
Plot Width 8.00 19.14 OK
Abutting Road(Including Shifted Road) 6.00 9.00 OK
Shifted Road NA 1.50 OK
Coverage Area 250.83 155.46 OK

Builtup Area 501.65 491.04 OK


Residential : 491.04
Commercial : 0.00
Industrial : 0.00
Special : 0.00
Existing : 0.00
Excess Balcony : 0.00
Sub Structure : 0.00
Refuge Area : 0.00
Tenement Density For Plot 250.00/Hec. 13 11 OK

Rules

Topic Rule
Minimum Plot Area required is 250.0 sq. mt. for building height upto 21.0
Plot Area
mt.and required Width is 8 mt. {As per DCR, pg.35,36 cl.11.4}
Built-up Area Coverage is 50% of Plot Area. {As per DCR,[Page 145]}
FSI Area FSI area shall be 1.0 {As per DCR, pg.144-app.N}
Tenement Density Factor is 250 tenement/Ha for net plot area {As per
Tenements Density
DCR,[pg. 148, tbl 27]}
TDR
Name Rule
Internal Roads in layout for Residential Project, for One side development
can have minimum width of 6 m. Road width shall be min 6 m for 0 to 75 m
long road. Road width shall be min 7.5 m for 75 to 150 m long road. Road
width shall be min 9.0 m for 150 to 300 m long road. Road width shall be
Proposed Road
min 12.0 m for more than 300 m long road. {As per DCR - [pg 29-tbl 3a]}
Every internal road having dead end in layout shall have cal-de-sac (turning
Plot space) with area not less than 81 sq.m. area with no dimensions being less
than 9 mt. as per DCR - Pg. 39
Pathway
Minimum required OpenSpace area is 200 sq. mt. and minimum dimention is
COP 7.5m. {As per DCR, cl.54 - [Page 50,51]}
Open Space not Required
Amenity Amenity Space not required. {As per DCR,[Page 42,cl. 13.6]}
Compound Wall
Name Rule
Area of Balconys for Residential Project, should not be more than 15% of
Balcony Total FSI Area. Rest of Balcony area is in Excess and must be considered in
FSI {As per DCR, cl 80-ii - [Page 68] }
Width of Passages for Residential Project, should be more than 1.0 {As per
Lobby
Building DCR,[Page 106-151]}
BasementFloor Height Above GroundLevel Min - 0.90 and Max - 1.20 {As
Basement Floor
per DCR, pg. 73, 74 tbl 5}
Reqd Ht is 1.05 m. and Permissible Ht is 1.2 m. {As per DCR (pg.59,cl.
Floor Height
17.13)}
Bldg Height {As per DCR, pg 46,cl.13.5}
Name Rule
Sanitation
A (BLDG)
Name Rule
Minimum width 1.2 mts is required for bath room. {As per DCR, cl. 94 - Tbl.
BATH
7; Pg. 85}
Minimum 9.3 sq. mts. area with minimum width 2.4 mts and minimum depth
2.4 mts is required for ch.bed, bed, m.bed, m. bed, master bed, mbed, living,
BED ROOM
living/dining, living/din., liv./din., living/kit., living/kitchen. {As per DCR,
pg.51-cl 15.2}
Minimum 5.5 sq. mts. area with minimum width 1.8 mts and minimum depth
KITCHEN 1.8 mts is required for kitchen,kitchen/dining,kit./din,kit./dining,kitchen/din.
Rooms
{As per DCR, cl. 94 - Tbl. 7; Pg. 84}
Minimum 9.3 sq. mts. area with minimum width 2.4 mts and minimum depth
2.4 mts is required for ch.bed, bed, m.bed, m. bed, master bed, mbed, living,
LIVING
living/dining, living/din., liv./din., living/kit., living/kitchen. {As per DCR,
pg.51-cl 15.2}
Maximum 3.0 sq. mts. area Permissible for Store, Pooja, Cabin and Study.
STUDY
{As per DCR, cl. 94 - Tbl. 7; Pg. 81}
Minimum 1.1 sq. mts. area and Minimum width 0.9 mts is required for W.C.
WC
{As per DCR, cl. 94 - Tbl. 7; Pg. 81}
Name Rule
Min Car Parking Area - 12.50 and Dim - 2.5 x 5.0 {As per DCR, Page 47,
Car Parking
cl.14, table 6}
Loading/Unloading Min Loading/Unloading Parking Area - 27.0 and Dim - 3.6 x 7.5 {As per
Parking DCR, Page 47, cl.14, table 6}
Req. driveway of 3.0m. Around the building for all uses except assembly uses
Parking for all margin and for Assembly use Req. driveway of 6.0m for parking
Driveway Parking
provided in front margin and 3.0m for other margin. {As per DCR,
pg.49,note-1}
Min Car Parking Area - 12.50 and Dim - 2.5 x 5.0 {As per DCR, Page 47,
cl.14, table 6} Min Scooter Parking Area - 2.0 and Dim - 1.0 x 2.0 {As per
Parking DCR, Page 47, cl.14, table 6} Min Cycle Parking Area - 1.4 and Dim - 0.7 x
2.0 {As per DCR, Page 47, cl.14, table 6} Min Loading/Unloading Parking
Area - 27.0 and Dim - 3.6 x 7.5 {As per DCR, Page 47, cl.14, table 6}
Name Rule
Tank Factor
Sanitation
Overhead Tank
UnderGround Tank
Name Rule
Minimum Flight width is 1.0 m., Minimum Tread width is 0.25 m. and
Satir-Case
Stair Case Maximum Riser width is 0.19 m. {As per [(DCR-2,pg. 38 cl. 17.3.5 and
17.4.3) and (DCR-1,pg. 90, tbl. 19-B)]}
Name Rule
Passage Width of Passages for Residential Project, should be more than 1.0 {As per
Passage
DCR,[Page 106-151]}
Name Rule
Arch. Chhajja/Cornice width should be less than the Permissible value 0.75 mt{As
CHHAJJA/CORNICE
Projections per DCR, pg. 67, cl.80}
LOFT Loft Height should Min. Reqd. 2.10 mt{As per DCR, pg. 67, cl.80}
Name Rule
ArtiVShaft For Building with Height 0-12 ventilation shaft shall have minimum area of 3
ArtiVShaft
sq. m. and width of 1.5 mts. {As per DCR - [ pg.57,cl.15.13.5]}
Name Rule
Required Area for Chowk is (H/5)x(H/5) and If ventilation is taken, whose
Inner
minimum width shall be 3 m and area not less than square of one fifth of the
Chowk Inner Chowk
height of the highest wall abutting the chowk {As per DCR - [pg
42,cl.13.1.4]}
Name Rule
Lift For Low Rise Building with Building Height less than 15 m. Lift is not
Lift
required.{As Per DCR [pg.61,cl. 16.1]}
Name Rule
Terrace Maximum permissible Width of sitout/individual terrace is 2.4m. {As per
Terrace
DCR, (pg. 43,cl.13.4.1-c and d)}
Name Rule
RefugeArea For Building Height upto 24 mt. Refuge Area is not Required. {As per DCR,
RefugeArea
pg 68, cl. 17.4.8}
Name Rule
Sub
RAIN WATER For PlotArea > 300 sq.mt. there shall be one Rain Water Harvesting structure
Structures
HARVESTING is necessary in Non-Congested Area. {As per DCR, pg.78,cl.24.4}

Disclaimer : AutoDCR is an input based software tool used by Municipal Corporations but the final approval lies with concerned Officer /
Authority.

Anda mungkin juga menyukai