VIOLATION: EXPOSED WIRING OF A LIGHTING SYSTEM CHAPTER 5: SPECIAL OCCUPANCIES ARTICLE 547 AGRICULTURAL BUILDINGS 547.5 WIRING METHODS (E) PHYSICAL PROTECTION ALL ELECTRICAL WIRINGS AND EQUIPMENTS SUBJECT TO PHYSICAL DAMAGE SHALL BE PROTECTED. RECOMMENDATION: FIX IT TO IMMEDIATELY TO AVOID THE DANGER IT MIGHT FELL ONTO OTHERS. WRONG RIGHT
LOCATION: 6127 ACES CODE UGONG, VALENZUELA CITY
VIOLATION: LIVE PARTS UNGUARDED ELECTRICAL CODE OF THE PHILIPPINES CHAPTER 1.10.2.2 (B) LIVE PARTS GUARDED AGAINTS ACCIDENTAL CONTACT, EXCEPT AS ELSEWHERE REQUIRED OR PERMITED BY THIS CODE, LIVE PARTS OF THE ELECTRICAL EQUIPMENT OPERATING AT 50V OR MORE SHALL BE GUARDED AGAINTS ACCIDENTAL CONTACTS BY APPROVED ENCLOSURES OR BY ANY OF THE FOLLOWING MEANS. RECOMMENDATION: FIX IT/ GUARD IT IMMEDIATELY FOR THE SAFETY OF EVERYONE. WRONG RIGHT
LOCATION: 6127 ACES CODE UGONG, VALENZUELA CITY
VIOLATION: DAMAGE FLOORING NATIONAL BUILDING CODE OF THE PHILIPPINES SECTION1205 FLOOR RECONSTRUCCTION (B) ALL FLOORS SHALL BE SO FRAMED AND TIED INTO THE FRAMEWORK ANF SUPPORTING WALLS AS TO FORM AN INTEGRAL PART OF THR WHOLE BUILDING. RECOMMENDATION: FIX THE DAMAGE FLOOR TO PREVENT ACCIDENTS WRONG RIGHT
LOCATION: 6127 ACES CODE UGONG, VALENZUELA CITY
VIOLATION: 590.6 GROUND-FAULT FOR PERSONNEL. (A) RECEPTACLE OUTLETS. RECEPTACLE OUTLETS NOT PART OF PERMANENT WIRING. ALL 125-VOLT, SINGLE PHASE, 15-, 20-, AND 30 AMPERE RECEPTACLE OUTLETS THAT ARE NOT A PART OF THE PERMANENT WIRING OF THE BUILDING OR STRUCTURE AND THAT ARE IN USE BY PERSONNEL SHALL HAVE GROUND-FAULT CIRCUIT- INTERRUPTER PROTECTION FOR PERSONNEL. IN ADDITION TO THIS REQUIRED GROUND-FAULT CIRCUIT-INTERRUPTER PROTECTION. LISTED CORD SETS OR DEVICES INCORPORATING LISTED GROUND-FAULT CIRCUIT- INTERRUPTER PROTECTION FOR PERSONNEL IDENTIFIED FOR PORTABLE USE SHALL BE PERMITTED. RECOMMENDATION: FIX IT TO AVOID THE DANGER IT MIGHT CAUSE GROUND TO A PERSON. WRONG RIGHT
LOCATION: 6127 ACES CODE UGONG, VALENZUELA CITY
VIOLATION: DAMAGE FLOORING OF ROOFTOP NATIONAL BUILDING CODE OF THE PHILIPPINES SECTION 1295 FLOOR CONSTRUCTION (B) ALL FLOORS SHALL BE SO FRAMED AND TIED INTO THE FRAMEWORK AND SUPPORTING WALLS AS TO FORM AN INTEGRAL, PART OF THE WHOLE BUILDING RECOMMENDATION: COVERED IT FOR THE BEAUTY OF HOUSE. WRONG RIGHT
LOCATION: 6127 ACES CODE UGONG, VALENZUELA CITY
VIOLATION: BROKEN DOOR KNOB NATIONAL BUILDING CODE OF THE PHILIPPINES SECTION 2.2 2.2.1.1 OBJECTIVES; SAFETY RESISTANCE TO AN UNWANTED ENTRY OS4.1 AN OBJECT OF THIS CODE IS TO LIMIT THE PROBABILITY THAT, AS A RESULT OF A DESIGN OF A CONSTRUCTION OF A BUILDING, A PERSON IN THE BUILDING WILL BE EXPOSED TO AN ACCEPTABLE RISK OF INJURY DUE TO THE BUILDINGS LOW LEVEL RESISTANCE TO UNWANTED ENTRY CAUSED BY INTRUDERS BEING ABLE TO FORCE THEIR WAY THROUGH LOCKED DOORS OR WINDOWS. RECOMMENDATION: INSTALLED A DOOR KNOB OR OTHER LOCKED FOR IT. PAMANTASAN NG LUNGSOD NG VALENZUELA POBLACION II, MALINTA, VALENZUELA CITY COLLEGE OF ENGINEERING CIVIL ENGINEERING DEPARTMENT SAFETY MANAGEMENT (EE 17)