Preliminary Site Survey Report

1. General Details of Site and Google Image.


Address G-18 ,Pushpanjali Farmhouse , Brijwasan , New
Delhi.
Coordinates 28 32 19.0 , 77 03 56.7
Survey Team Representatives Deborshi and Sunil Singh
Contact Person from Client Mr Pankaj - 0985956404
Date and Time 24 / 05 /2017 , 13.00 HRS

2. Roof Details
Type of Roof RCC Roof with Tiles covering
Height of the Bundary Wall Approx 900 mm
Building height Approx 10 to 12 m
Can Inverter Be placed on the roof Yes but may canopy have to be provided
Is roof Accessible Yes direct access to roof is possible through stairs
Area Pics Area 1

Height of the mumty 2 meters and its situated on north side.

Parapet wall is situated on south and the height is 0.9 Meter.

Area 2 Height of Parapet wall is 0.9 Meters .

There is a Group of OUTDOOR ac unit installed on the North- East side of roof , with height upto 2 meters . shadow will
fall till half of the area 2 . Same has been shown in module layout .
Area 3-
No potential Shadow. Height of parapet wall 0.9 meter.

3. Electrical Details
Sanctioned Load There are two type of load which is operated at the client
end.One is 20 kW load and another is 17 kW load due to
which 2 tye of Electricity bills are generated and 2 type of
meter are installed
No of Servo meters 2
No of DG 2
Feasibility of SPV Syatem A single plant of 30 kW can be installed but in that case two
different Bi-Directional meter have to be provided with 2
differenr Bus Bar Chamber box or only one single plant of 15
to 17 kW

Power Tapping at LT and HT LT before Servo for which Bus Bar Chamber Box is required
No of Bi-directional Meter to Be Installed 1 or 2 depending upon the overall capacity of the plant
Pannel Details
4. Module Layout
As mentioned there can be 2 options for the type of connection exist and they are as follows:

1. One Single plant of 15 to 17 kW in which we are ready to install one Bi-Directional Meter
2. A complete plant of 30 kW to cater the total load but in that case 2 Bi-Directional meter
have to be installed along with certain changes in the AC Distribution Box which will entirely
depend on commercial closure.
3. Presently we offer one single plant of 15 to 17 kW module layouts.