Approximate sign locations are shown on Drawing Numbers HT 4.02 to HT 419. Sign locations should be
fixed on site in accordance with the Kuwait Traffic Signs Manual and agreed with the Engineer.
Page 1
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
1 201-022 3 40 205-060 40
2 201-023 4 41 205-063 41
3 201-025 5 42 205-066 42
4 201-026 6 43 205-069 43
5 201-027 7 44 205-072 44
6 201-028 8 45 205-075 45
7 201-029 9 46 205-078 46
8 201-034 78
9 201-035 79 47 207-052 47
10 202-001 26 48 208-053 48
11 202-002 10
12 202-003 11 49 212-043 49
13 202-004 12 50 212-058 50
14 202-005 13 51 212-061 51
15 202-006 27 52 212-067 52
16 202-007 28 53 212-073 53
17 202-008 14 54 212-076 54
18 202-009 29
19 202-010 15 55 213-040 55
20 202-014 30 56 213-041a 56
21 202-015 16 57 213-041b 57
22 202-016 31 58 213-046 58
23 202-017 17 59 213-048 59
24 202-018 18 60 213-051 60
25 202-019 19 61 213-054 61
26 202-020 20 62 213-055 62
27 202-021 21 63 213-056 63
28 202-024 22 64 213-059 64
29 202-030 23 65 213-062 65
30 202-031 32 66 213-064 66
31 202-032 24 67 213-065 67
32 202-033 25 68 213-068 68
69 213-071 69
33 203-081 33 70 213-074 70
71 213-077 71
34 205-042 34 72 213-079 73
35 205-045 35 73 213-080 72
36 205-047 36
37 205-049 37 74 DP--82 74
38 205-050 38 75 DP--83 75
39 205-057 39 76 DP--84 76
77 DP--85 77
Page 2
Sign Facia Sign Reference: 201-022
Sign Information
x-height: 200 mm Location Description: 40 - approaching junction with FRR. Left turn panel (2 no.)
50 n/b - approaching junction with FRR. Left turn panel (1 no.)
Quantity: 3
Colour: Green No of Lanes: 2
Sign Size
Page 3
Sign Facia Sign Reference: 201-023
Sign Information
x-height: 200 mm Location Description: 40 - junction with FRR. Left turn panel
Sign Size
Page 4
Sign Facia Sign Reference: 201-025
Sign Information
x-height: 200 mm Location Description: 40 - FRR. Left turn panel on junction gantry
Sign Size
Page 5
Sign Facia Sign Reference: 201-026
Sign Information
x-height: 200 mm Location Description: 40 - FRR. Straight ahead panel on junction gantry
Sign Size
Page 6
Sign Facia Sign Reference: 201-027
Sign Information
x-height: 200 mm Location Description: FRR c/w - 40 exit slip. Ahead panel on gantry
Sign Size
Page 7
Sign Facia Sign Reference: 201-028
Sign Information
Sign Size
Page 8
Sign Facia Sign Reference: 201-029
x-height: 200 mm Location Description: 50 n/b - approaching junction with FRR. Ahead panel.
Sign Size
Page 9
Sign Facia Sign Reference: 202-002
Salhiya 1
Dasman
Sign Information
Sign Size
Page 10
Sign Facia Sign Reference: 202-003
Hawally
1
Mirqab & Ahmadi
Sign Information
x-height: 200 mm Location Description: FRR - 50 exit anti c/w - ahead panel
Sign Size
Page 11
Sign Facia Sign Reference: 202-004
50
Salhiya
Airport
Sign Information
x-height: 200 mm Location Description: FRR - 50 exit anti c/w - exit panel (advance sign)
Sign Size
Page 12
Sign Facia Sign Reference: 202-005
50
Salhiya
Airport
Sign Information
x-height: 200 mm Location Description: FRR - 50 exit anti c/w - exit panel (at junction)
Sign Size
Page 13
Sign Facia Sign Reference: 202-008
85
Blue Replaces existing sign
Shuwaikh
Airport Green
50
Salhiya
Sign Information
Sign Size
Page 14
Sign Facia Sign Reference: 202-010
Qibla
Sign Information
x-height: 200 mm Location Description: FRR-Shuhada St exit c/w - exit panel (2 no.)
JA Nasser to FRR c/w - right fork at decision point (1 no.)
Quantity: 3
Colour: Blue No of Lanes: 1
Sign Size
Page 15
Sign Facia Sign Reference: 202-015
Qibla
Sign Information
x-height: 200 mm Location Description: FRR - Shuhada St exit anti c/w - exit panel
Sign Size
Page 16
Sign Facia Sign Reference: 202-017
Shuwaikh 85
Jahra
Sign Information
x-height: 200 mm Location Description: FRR - JA Nasser St exit anti c/w - exit panel (2 no.)
50 to FRR c/w & JA Nasser - right fork at decision point (1 no.)
Quantity: 3
Colour: Blue No of Lanes: 1
Sign Size
Page 17
Sign Facia Sign Reference: 202-018
Sief 1
City Centre
Sign Information
x-height: 200 mm Location Description: JA Nasser to FRR c/w - left fork at decision point
Sign Size
Page 18
Sign Facia Sign Reference: 202-019
Qibla 1
City Centre
Sign Information
x-height: 200 mm Location Description: 50 to FRR c/w & JA Nasser - Left fork at decision point.
Sign Size
Page 19
Sign Facia Sign Reference: 202-020
1
Dasman
Sign Information
x-height: 200 mm Location Description: Shuhada St to FRR c/w - left fork at decision point
Sign Size
Page 20
Sign Facia Sign Reference: 202-021
Justice Palace
Sign Information
x-height: 200 mm Location Description: Shuhada St to FRR c/w - right fork at decision point
Sign Size
Page 21
Sign Facia Sign Reference: 202-024
Sign Information
x-height: 200 mm Location Description: 40 - approach to FRR junction. Left turn panel
Sign Size
Page 22
Sign Facia Sign Reference: 202-030
Sign Information
x-height: 200 mm Location Description: 50 n/b - approach to FRR junction. Left turn panel.
Sign Size
Page 23
Sign Facia Sign Reference: 202-032
Sign Information
x-height: 200 mm Location Description: 50 s/b - approach to FRR junction. Left turn panel.
Sign Size
Page 24
Sign Facia Sign Reference: 202-033
Sign Information
x-height: 200 mm Location Description: 50 s/b - approach to FRR junction. Right turn panel.
Sign Size
Page 25
Sign Facia Sign Reference: 202-001
1
Qibla & City Centre
Sign Information
Sign Size
Page 26
Sign Facia Sign Reference: 202-006
Sign Information
x-height: 200 mm Location Description: FRR - 40 exit anti c/w ahead panel
Sign Size
Page 27
Sign Facia Sign Reference: 202-007
Sign Information
x-height: 200 mm Location Description: FRR - 50 exit c/w - ahead panel on advance sign
Sign Size
Page 28
Sign Facia Sign Reference: 202-009
1
Sief & City Centre
Sign Information
x-height: 200 mm Location Description: FRR - Shuhada St exit c/w - ahead panel
Sign Size
Page 29
Sign Facia Sign Reference: 202-014
1
Shuwaikh & Jahra
Sign Information
x-height: 200 mm Location Description: FRR - Shuhada St anti c/w ahead panel
Sign Size
Page 30
Sign Facia Sign Reference: 202-016
1
Airport & Salhiya
Sign Information
x-height: 200 mm Location Description: FRR - JA Nasser St anti c/w - ahead panel
Sign Size
Page 31
Sign Facia Sign Reference: 202-031
Sign Information
x-height: 200 mm Location Description: 50 n/b - junction with FRR. Ahead panel
Sign Size
Page 32
Sign Facia Sign Reference: 203-081
1
Qibla
400
Green Blue
Sign Information
x-height: 150 mm Location Description: Advance direction sign for Shuhada St exit ac/w - for temp tie-in
Sign Size
Overall size
Width Height
1866 x 2257.5
Page 33
Sign Facia Sign Reference: 205-042
1
Fahaheel
Sign Information
x-height: 100 mm Location Description: Entry slip to FRR from 40 (anti c/w)
Sign Size
Overall size
Width Height
1755 x 1995
Page 34
Sign Facia Sign Reference: 205-045
Replaces existing sign
85 Blue
Shuwaikh
50
Green
Airport
Blue
Salhiya
Safat
Sign Information
Sign Size
Overall size
Width Height
2236 x 2535
Page 35
Sign Facia Sign Reference: 205-047
Replaces existing sign
85
Blue
Shuwaikh
1 Green
City Centre
Green
50
Airport
Sign Information
Sign Size
Overall size
Width Height
2362 x 1995
Page 36
Sign Facia Sign Reference: 205-049
Blue
Salhiya
Safat
50 Green
Airport
Sign Information
x-height: 100 mm Location Description: Exit slip from FRR to 50 (anti c/w)
Sign Size
Overall size
Width Height
2236 x 1995
Page 37
Sign Facia Sign Reference: 205-050
Replaces existing sign
Green
Ahmadi
1
Dasman
Blue
Salhiya
Safat
Sign Information
Sign Size
Overall size
Width Height
1728 x 2435
Page 38
Sign Facia Sign Reference: 205-057
Arabian Gulf Street
Qibla
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR c/w
Sign Size
Overall size
Width Height
2912 x 1355
Page 39
Sign Facia Sign Reference: 205-060
Blue
Shuwaikh
Green
1
Dasman
Sign Information
Sign Size
Overall size
Width Height
2712 x 1995
Page 40
Sign Facia Sign Reference: 205-063
1 Green
Shuwaikh
Blue
Qibla
Blue
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR anti c/w
Sign Size
Overall size
Width Height
2912 x 1995
Page 41
Sign Facia Sign Reference: 205-066
Qibla Blue
1
Dasman Green
1
Shuwaikh Green
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from Arabian Gulf St
Sign Size
Overall size
Width Height
1996 x 1995
Page 42
Sign Facia Sign Reference: 205-069
Souk
Sief
Qibla
Sign Information
x-height: 100 mm Location Description: FRR - Temp Tie-in - approach from FRR
Sign Size
Overall size
Width Height
1465 x 1995
Page 43
Sign Facia Sign Reference: 205-072
Blue
Sief
1 Green
Shuwaikh
Souk Blue
Sign Information
x-height: 100 mm Location Description: FRR - Temp Tie-in - approach from Qibla
Sign Size
Overall size
Width Height
2046 x 1995
Page 44
Sign Facia Sign Reference: 205-075
1 Green
Shuwaikh
Blue
Qibla
Blue
Sief
Sign Information
Sign Size
Overall size
Width Height
1384.5 x 1496.25
Page 45
Sign Facia Sign Reference: 205-078
Blue
Qibla
Blue
Souk
Green
1
Shuwaikh
Sign Information
x-height: 100 mm Location Description: FRR - Temp Tie-in - approach from Sief
Sign Size
Overall size
Width Height
2046 x 1995
Page 46
Sign Facia Sign Reference: 207-052
1 85
Qibla Shuwaikh
City Centre Jahra
Green Blue
Sign Information
Sign Size
5.87 7.58
5.02 8.96
14.12 7.75
10.63 5 1.25 2 26.33
Overall size
Width Height
2633 x 2230
Page 47
Sign Facia Sign Reference: 208-053
Fahd Al-Salem Street
Soor Street Soor Street
West East
Shamiya
Sign Information
Sign Size
12.59 12.59
6.9 7.92 Overall size
10.86 10.86 Width Height
4.7 4.21 3013.5 x 1698.75
7.74
7.87
1 12 2 40.18
Page 48
Sign Facia Sign Reference: 212-043
Sign Information
x-height: 100 mm Location Description: Entry slip to FRR from 40 (anti c/w). Left fork at decision point.
Sign Size
Overall size
Width Height
1255 x 1880
Page 49
Sign Facia Sign Reference: 212-058
Qibla
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR c/w
FRR - temp tie-in - approach from FRR
Quantity: 2
Colour: Blue No of Lanes: 2
Sign Size
Overall size
Width Height
787 x 1240
Page 50
Sign Facia Sign Reference: 212-061
Dasman
1
Sign Information
Sign Size
Overall size
Width Height
1000 x 1240
Page 51
Sign Facia Sign Reference: 212-067
Shuwaikh
1
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from Arabian Gulf Street
Sign Size
Sawaber
Name 1 Total Name Arrow Arrow Pos'n Route No Airport Tile Borders Spaces Total
1 - Diagonal Below 1 No
7.58 7.58
8.96 8.96
0 0
0 0 4.5 3 0 1 1 10.96
Overall size
Width Height
1096 x 1240
Page 52
Sign Facia Sign Reference: 212-073
Souk
Sign Information
x-height: 100 mm Location Description: FRR - temp tie-in - approach from Qibla
Sign Size
Overall size
Width Height
847 x 1240
Page 53
Sign Facia Sign Reference: 212-076
Sief
Sign Information
Sign Size
Overall size
Width Height
686.25 x 930
Page 54
Sign Facia Sign Reference: 213-040
Sign Information
Sign Size
Overall size
Width Height
2351 x 1355
Page 55
Sign Facia Sign Reference: 213-041a
Sign Information
x-height: 100 mm Location Description: 40 s/b -FRR junction (positioned on same post as 213-041b)
Sign Size
Overall size
Width Height
1309 x 715
Page 56
Sign Facia Sign Reference: 213-041b
Sign Information
x-height: 100 mm Location Description: 40 s/b -FRR junction (positioned on same post as 213-041a)
Sign Size
Overall size
Width Height
2013 x 715
Page 57
Sign Facia Sign Reference: 213-046
Salhiya
Safat
Sign Information
x-height: 100 mm Location Description: 50-FRR junction - approach from FRR c/w
Sign Size
Overall size
Width Height
1517 x 1355
Page 58
Sign Facia Sign Reference: 213-048
Sign Information
Sign Size
Overall size
Width Height
1815 x 1355
Page 59
Sign Facia Sign Reference: 213-051
x-height: 100 mm Location Description: 50-FRR junction - approach from FRR anti c/w
Sign Size
Overall size
Width Height
1517 x 1355
Page 60
Sign Facia Sign Reference: 213-054
Shamiya
Sign Information
Sign Size
Overall size
Width Height
2017 x 1073
Page 61
Sign Facia Sign Reference: 213-055
Arabian Gulf Street
Sign Information
Sign Size
Overall size
Width Height
4079 x 1073
Page 62
Sign Facia Sign Reference: 213-056
80
Jahra
Sign Information
Sign Size
Overall size
Width Height
2693 x 1073
Page 63
Sign Facia Sign Reference: 213-059
Arabian Gulf Street
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR c/w
Sign Size
Overall size
Width Height
2720 x 715
Page 64
Sign Facia Sign Reference: 213-062
1
Shuwaikh
Sign Information
Sign Size
Overall size
Width Height
1854 x 715
Page 65
Sign Facia Sign Reference: 213-064
Arabian Gulf Street
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR anti c/w
Sign Size
Overall size
Width Height
2720 x 715
Page 66
Sign Facia Sign Reference: 213-065
Qibla
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from FRR anti c/w
Sign Size
Overall size
Width Height
1145 x 715
Page 67
Sign Facia Sign Reference: 213-068
1
Dasman
Sign Information
x-height: 100 mm Location Description: Shuhada St junction - approach from Arabian Gulf Street
Sign Size
Overall size
Width Height
1707 x 715
Page 68
Sign Facia Sign Reference: 213-071
Sief
Sign Information
x-height: 100 mm Location Description: FRR - temp tie-in - approach from FRR
Sign Size
Overall size
Width Height
1273 x 715
Page 69
Sign Facia Sign Reference: 213-074
1
Shuwaikh
Sign Information
x-height: 100 mm Location Description: FRR - temp tie-in - approach from Qibla
Sign Size
Overall size
Width Height
1854 x 715
Page 70
Sign Facia Sign Reference: 213-077
Qibla
Sign Information
Sign Size
Overall size
Width Height
858 x 536
Page 71
Sign Facia Sign Reference: 213-080
Souk
Sign Information
x-height: 100 mm Location Description: FRR - temp tie-in - approach from Sief
Sign Size
Overall size
Width Height
1205 x 715
Page 72
Sign Facia Sign Reference: 213-079
1
Shuwaikh
Sign Information
x-height: 100 mm Location Description: FRR - temp tie-in - approach from Sief
Sign Size
Overall size
Width Height
1854 x 715
Page 73
Sign Facia Sign Reference: DP-082
400
Sign Information
x-height: 200 mm Location Description: Distance Plate with Advance sign for Shuhada St exit c/w -
Sign Support SS3
Sign Size
Width (in terms of x-height): Text 6.19 Depth (in terms of x-height): Text 3.4
Borders 1 Borders 1
Spaces 1 Spaces 0.75
Total 8.19 Total 5.15
Page 74
Sign Facia Sign Reference: DP-083
450
Sign Information
x-height: 200 mm Location Description: Distance Plate with Advance sign for 50 junction ac/w -
Sign Support SS2
Sign Size
Width (in terms of x-height): Text 6.08 Depth (in terms of x-height): Text 3.4
Borders 1 Borders 1
Spaces 1 Spaces 0.75
Total 8.08 Total 5.15
Page 75
Sign Facia Sign Reference: DP-084
150
Sign Information
x-height: 200 mm Location Description: Distance Plate with Advance sign for FRR on JA Nasser St -
Sign Gantry OH1
Sign Size
Width (in terms of x-height): Text 5.55 Depth (in terms of x-height): Text 3.4
Borders 1 Borders 1
Spaces 1 Spaces 0.75
Total 7.55 Total 5.15
Page 76
Sign Facia Sign Reference: DP-085
350
Sign Information
x-height: 200 mm Location Description: Distance Plate with Advance sign for JA Nasser St exit ac/w -
Sign Support SS4
Sign Size
Width (in terms of x-height): Text 6.03 Depth (in terms of x-height): Text 3.4
Borders 1 Borders 1
Spaces 1 Spaces 0.75
Total 8.03 Total 5.15
Page 77
Sign Facia Sign Reference: 201-034
1
Replaces existing sign
Qibla & City Centre
Sign Information
x-height: 200 mm Location Description: FRR c/w - 50 interchange. 1st advance sign
Sign Size
Page 78
Sign Facia Sign Reference: 201-035
50
Salhiya
Sign Information
x-height: 200 mm Location Description: FRR c/w - 50 interchange. 1st advance sign
Sign Size
Page 79
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
APPENDIX B
1400 General
The lighting and electrical works shall be in accordance with the requirements
of Section XIV, Lighting and Electrical Works of the General Specifications,
Section 14 of Division II of Document III-2 and as modified in this Appendix.
Should there be any difference between the General Specifications, Division II
of Document III-2 or Contract Drawings and this Appendix, then the
requirements of the Appendix shall prevail.
14.00.03 Penalty for Failure to Complete Electrical Rectification Works
The Contractor shall complete all lighting works, including all rectification works within
90 days of Substantial Completion. In the event the Contractor fails to complete such
rectification works to the Engineer's approval within the above specified time, he shall
incur a penalty of Kuwait Dinars One Hundred and Fifty (KD.150/-) per day until the
Works are completed to the Engineer's satisfaction.
The Contractor shall submit the name of the sub-contractor he proposes to use for
lighting and electrical works to the Engineer for approval.
and Bros.
The Contractor shall submit in duplicate the following Submittal Schedules which are
incorporated herein, fully, completed and signed for the Ministry of Electricity & Water
approval at Approval Stage B - Materials Approval, as required by Clause 1401.09 of
the General Specifications.
The Ministry of Electricity & Water shall be notified at least four (4) weeks in advance
before any field performance tests or inspection works on the permanent lighting
works are to be carried out. The Contractor shall provide to the Ministry of Electricity &
Water Engineer as-built working drawings and all current, voltage, insulation
resistance and earth resistance readings in three (3) complete sets before he will
proceed for any inspection. He shall make available all tools, test equipment including
luxmeter, luminance meter, theodolites, necessary transport and ladder vehicles,
labourers, etc. to the M.E.W. Engineer during carrying out of the inspection works.
14.01.13.1 General
All existing lighting units, lighting control cabinets/feeder pillars and underground
cabling being replaced by new work on this Contract shall be removed and salvaged
for later reuse by the Employer, unless otherwise directed by the Engineer or shown
on the Drawings. The Contractor shall obtain the Engineers approval prior to the
removal of any such existing work.
All materials designated for reuse in this Contract shall be stored off the ground and
adequately protected to the satisfaction of the Engineer. The method and location of
storage of such materials shall be to the approval of the Engineer.
All recovered materials designated for returning to MEW store shall be salvaged,
temporarily stored, loaded, hauled, unloaded and stored where directed by the MEW.
All materials shall be stored off the ground and adequately protected to the satisfaction
of the MEW.
All foundations of existing lighting masts, poles and control cabinets/feeder pillars
which are to be removed and not replaced by refurbished units shall be removed and
disposed of in accordance with Section II of the Specifications.
The Contractor shall refurbish and relocate the existing lighting masts and poles as
indicated on the drawings and as specified herein. All existing 30 metre high masts
and 16m and 10m light poles shall be carefully dismantled and transported to
contractor's workshop for refurbishing.
The refurbishing work of the existing lighting units shall include, but not be limited to
the following:
1. Thorough cleaning of the exterior and interior of each lighting unit and
components therein.
4. Furnishing and installing of new lamps for all resited lighting units.
6. Rewiring the installation of new component parts where specified and/or when
directed and the rectification of all deteriorated and damaged parts.
7. Furnishing and installing new cable for resited units as well as for connections, if
any, between resited units and the existing units.
8. Furnishing and installing new grounding and lightning protection systems for
30m masts.
9. Furnishing new grounding systems for 16m and 10m lighting units.
11. Furnishing and replacing locking arrangements on mast and pole doors.
The Contractor shall refurbish and relocate the existing lighting control cabinets/feeder
pillars as indicated on the drawings and as specified herein. All existing control
cabinets/feeder pillars shall be carefully dismantled and transported to contractor's
workshop for refurbishing.
The refurbishing work of the existing lighting control cabinets/feeder pillars shall
include, but not be limited to the following:
1. Thorough cleaning of the exterior and interior of each cabinet and all
components therein.
4. Rewiring the installation of new component parts where specified and/or when
directed and the rectification of all deteriorated and damaged parts.
6. Furnishing and installing new cable for resited control cabinets/feeder pillars as
well as for connections, if any, between resited units and the existing units.
14.01.13.4 New Foundations for Lighting Masts, Poles and Control Cabinets/Feeder
Pillars
The Contractor shall construct new foundations at each relocated lighting unit and
control cabinet/feeder pillar location. All such foundations shall conform with the
requirements of Clause 1403 of the General Specifications. The Contractor shall
furnish and install new anchor bolts, to match existing anchor bolts being removed.
New bolts shall be of the same material, diameter, dimensions and configuration of the
existing bolts and shall be as approved by the Engineer. The new foundations for
refurbished units shall be the same size as those being provided for new installations.
The Contractor shall install new cable and reset the existing lighting units and control
cabinets/feeder pillars on new foundations. The Contractor shall install all new
underground cable and complete all connections and terminations for electrification of
these relocated units.
The Contractor shall remove the redundant street lighting units and feeder pillars in
accordance with the requirements of Clause 1401.13.2 of the Specifications.
As part of his obligations the Contractor shall make all necessary arrangements with
the Ministry of Electricity & Water for the disconnection of power supply to the lighting
units and feeder pillars.
Upon completion of the installation of the new cable and final connection of the same
and/or when directed by the Engineer and the MEW, the Contractor shall hand
excavate, remove and salvage existing redundant underground cables under the
supervision of and to the satisfaction of the Ministry of Electricity and Water and as
directed by the Engineer.
The Contractor shall furnish and utilize pulleys or other approved devices to prevent
any damage to existing cables being removed and salvaged. The Contractor shall
recover intact each full length of existing redundant cable unless otherwise directed by
the Engineer. Salvaged cables shall be cut at either end of the length removed and no
intermediate cuts will be permitted unless approved by the Engineer. The Contractor
shall furnish drums upon which he shall wind the salvaged cable. Each reel shall be
tagged or marked to identify the cable voltage, type and length wound on their
respective drums.
The Contractor shall carefully handle the salvaged cable, cable cover tiles and all
other appurtenances and other materials to prevent any damage to same.
All excavation and backfill in removal and salvage of existing electrical material shall
comply with the applicable requirements of Section II of the General Specifications.
14.02.03 Underground Cable Installation in UPVC Cable Ducts in Areas Outside of Median
Barriers.
All street lighting cables within the limits of works of the contract except those in the
median barriers only, shall be installed in UPVC cable ducts, all as specified in clause
1402.03 of the Amendment No.1 to Section XIV. The Contractor shall prepare and
submit detailed drawings for the cable ducts and handholes layout for the Engineer's
approval and no works shall be started at site until and unless the layout drawings are
approved by the M.E.W. Engineer.
The locations shown on the Drawings for all high masts and conventional lighting units
are indicative only. The Engineer will provide setting out details of all installations at
the appropriate time.
14.03.04 Positioning and Aligning of Lighting Masts and Poles on Concrete Foundations
The high lighting masts installed along the median of the motorways shall have their
head frame assembly fixed in such a way that for the 6-lantern configuration, 2 nos. of
lanterns are at right angles to the carriageways and the remaining 4 nos. at 60
degrees, 2 nos. on either side. Installations with lanterns positioned along the centre
line of the median, whether for 6-lantern or 4-lantern configurations, will not be
accepted.
The doors of the lighting masts and poles installed along the medians shall be directed
towards Northward or Eastward except where the existing lighting installation at the
interfaces in having a different arrangement. In all cases, however, the M.E.W.
Engineer's approval must be obtained before erecting any lighting mast or pole along
the medians.
All lighting masts and poles erection and before any grouting is performed shall be
vertically aligned. The Contractor shall have in his possession two theodolites for this
purpose which he shall simultaneously employ to have bearings from two right-
angled directions while correcting the vertical alignment of the masts and the poles.
The Ministry of Electricity and Water reserves the right to reject part or whole of the
installation in case masts and poles are not aligned properly.
Where refurbished units are to be relocated in their original position, new cables shall
be installed between the units and the control cabinets/feeder pillars, all in complete
lengths without any joint.
14.05.01 General
Earth continuity conductors for conduit wiring systems shall be of the same type as
specified under Clause 1404.03 of the General Specifications and shall be sized in
accordance with the relevant Ministry of Electricity and Water Regulations.
New earth bonding and grounding and lightning protection system shall be installed to
all refurbished lighting masts and poles.
Each individual section of a high mast shall be one piece only and sections jointed by
welding will not be acceptable. The masts shall be hot-dip galvanized, both internally
and externally to BS EN ISO 1461: 1999. All brackets and foundation bolt frames shall
be hot-dip galvanized.
The base compartments shall be fitted with an over-lapping type hinged doors and
high heat resistant silicon rubber gaskets having a minimum thickness of 4 mm. shall
be provided all around for weather-proofing to comply with the protection category of
minimum IP 33 to IEC: 529. The door openings shall be stiffened by minimum 80 mm.
wide and 10 mm. thick substantial steel frame all around projected inside and outside
and continuously welded throughout. The galvanized steel hinges shall be minimum 3
mm. thick and 3 Nos. of 80 mm. long hinges shall be provided for each door. The dia.
of the hinge pin shall be minimum 5 mm. and the hinge leaves shall be continuously
welded all around to the body of the mast and the door in an aesthetic manner subject
to Engineer's approval. The centre hinge shall be reversed to make the doors non-
removable The manufacturer shall submit a guarantee stating that the galvanized steel
hinges will not break within a period of twenty-five (25) years and if any hinge breaks
within this period, the same will be replaced free of charge.
Stainless steel hinges may be considered by the Engineer provided they are of a very
high quality and the Contractor is ready to submit a guarantee stating that the hinges
will not corrode in 25 (twenty-five) years time and if any corrosion occurs or any hinge
breaks within this period at whatever site conditions it may be, they
will replace and re-fix all hinges at no extra cost whatsoever. The stainless steel hinges
shall be of the same dimensions and thickness as stated above for the galvanized
steel hinges and shall be fitted to the body of the mast and the door by at least 2 nos.
of 6 mm. high quality stainless hexagonal socket head steel bolts, two nuts and
necessary plane and spring washers.
App B -Ra106 Street Lighting Dec03 Page 15
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
Alternative design for door hinges which meet the above requirements as a minimum
may be submitted for the M.E.W. Engineer's approval.
The flange plate of the 38 metre, 35 metre and 30 metre high masts shall be
continuously welded to the mast from inside and outside in an approved manner.
Adequate number of suitably dimensioned gusset plates shall be fixed to the flange
plates of the high masts. The Manufacturer's name, date of manufacture and the
Contract No. shall be marked at the front side of the flange plates with minimum 1 mm.
deep engraving or punching.
The masts shall be provided with an additional earth terminal same as the grounding
system terminal for connecting the lightning protection conductor.
The Contractor shall submit a guarantee from the manufacturer stating that the
designed life time of the high lighting masts is for minimum twenty-five (25) years at
Kuwaits extreme weather and wind conditions stipulated and if any lighting mast fails
within this period, the same will be replaced free of charge. Without the guarantee,
the high lighting masts will not be accepted.
All the 38, 35 and 30 metre masts shall be American, European or Japanese
manufactured only.
The lighting poles including all base compartment doors, brackets, anchor bolts,
frames, etc., shall be fabricated from high quality structural steel equivalent to or better
than Euronorm 25-72 Grade Fe 510B. The Grade of steel as per BS:4360 shall be
minimum 50B and the steel shall have a minimum tensile strength of 490 N/sq.mm.
and yield strength, 355 N/sq.mm. All poles shall be hot-dip galvanized, both internally
and externally to BS EN ISO 1461: 1999. All brackets and foundation bolt frames shall
be hot-dip galvanized.
The base compartments shall be fitted with an over-lapping type hinged doors and
high heat resistant silicon rubber gaskets having a minimum thickness of 4 mm. shall
be provided all around for weather-proofing to comply with the protection category of
minimum IP 33 to IEC: 529. The door openings shall be stiffened by minimum 80 mm.
wide and 10 mm. thick substantial steel frame all around projected inside and outside
and continuously welded throughout. The galvanized steel hinges shall be minimum 3
mm. thick and 3 Nos. of 80 mm. long hinges shall be provided for each door. The dia.
of the hinge pin shall be minimum 5 mm. and the hinge leaves shall be continuously
welded all around to the body of the pole and the door in an aesthetic manner subject
to Engineer's approval. The centre hinge shall be reversed to make the doors non-
removable The manufacturer shall submit a guarantee stating that the galvanized steel
hinges will not break within a period of twenty-five (25) years and if any hinge breaks
within this period, the same will be replaced free of charge.
Stainless steel hinges may be considered by the Engineer provided they are of a very
high quality and the Contractor is ready to submit a guarantee stating that the hinges
will not corrode in 25 (twenty-five) years time and if any corrosion occurs or any hinge
breaks within this period at whatever site conditions it may be, they will replace and re-
fix all hinges at no extra cost whatsoever. The stainless steel hinges shall be of the
same dimensions and thickness as stated above for the galvanized steel hinges and
shall be fitted to the body of the pole and the door by at least 2 nos. of 6 mm. high
quality stainless hexagonal socket head steel bolts, two nuts and necessary plane and
spring washers.
Alternative design for door hinges which meets the above requirements as a minimum
may be submitted for the Ministry of Electricity & Water Engineer's approval.
The flange plate shall be continuously welded to the pole from inside and outside in an
approved manner and adequate number of suitably dimensioned gusset plates shall
be fixed to the flange plates of the 22 metre lighting poles. The size of the gusset
plates for 16 metre lighting poles shall be 180 mm x 90 mm x 10 mm (Th) which shall
be continuously welded to the body of the pole and the flange plate. The
Manufacturer's name, date of manufacture and the Contract No. shall be marked at the
front side of the flange plates with minimum 1 mm. deep engraving or punching.
The 22 metre lighting poles shall be provided with an additional earth terminal same as
the grounding system terminal for connecting the lightning protection conductor.
The Contractor shall submit a guarantee from the manufacturer stating that the
designed life time of the lighting poles is for minimum twenty-five (25) years at Kuwaits
extreme weather and wind conditions stipulated and if any lighting column fails within
this period, the same will be replaced free of charge. Without the guarantee, the
lighting poles will not be accepted.
14.09.03 10 Metre Lighting Pole with Brackets - Single arm and Double Arm
The pole shall be ten (10) metres in length, conical in shape, circular in cross section,
having spigot at the top and substantial flange plate at the bottom with a foundation
bolt frame. The shaft of the pole shall not be more than one section and the pole shall
be complete with one demountable bracket intended to hold 1 No. (for single arm) or 2
Nos (for double arms) 400 watts cut-off lanterns.
The lighting poles including all base compartment doors, brackets, anchor bolts,
frames, etc., shall be fabricated from high quality structural steel. The Grade of steel
as per BS:4360 shall be minimum 50B and the steel shall have a minimum tensile
strength of 490 N/sq.mm. and yield strength, 355 N/sq.mm. All columns shall be hot-
dip galvanized, both internally and externally to BS EN ISO 1461: 1999. All brackets
and foundation bolt frames shall be hot-dip galvanized.
The base compartments shall be fitted with flush or over-lapping type hinged doors
with a continuously welded 25 mm. by 8 m steel frame all around the door opening.
High heat resistant silicon rubber gaskets having a minimum thickness of 4 mm. shall
be provided all around for weather-proofing to comply with the protection category of
App B -Ra106 Street Lighting Dec03 Page 17
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
minimum IP 33 to IEC:529. The galvanized steel hinges shall be minimum 3mm. thick
and 3 Nos. of 80 mm. long hinges shall be provided for each door. The dia. of the
hinge pin shall be minimum 5 mm. and the hinge leaves shall be continuously welded
all around to the body of the pole
and the door in an aesthetic manner subject to the Engineers approval. The centre
hinge shall be reversed to make the doors non-removable. The manufacturer shall
submit a guarantee stating that the galvanized steel hinges will not break within a
period of twenty-five (25) years and if any hinge breaks within this period, the same
will be replaced free of charge.
Stainless steel hinges may be considered by the Engineer provided they are of a very
high quality and the Contractor is ready to submit a guarantee stating that the hinges
will not corrode in 25 (twenty-five) years time and if any corrosion occurs within this
period they will replace and re-fix all hinges at no extra cost whatsoever. The stainless
steel hinges shall be of the same dimensions and thickness as stated above for the
galvanized steel hinged and shall be fitted to the body of the pole and the door by at
least 2 Nos. high quality stainless hexagonal socket head steel bolts, two nuts and
necessary plane and spring washers.
Alternative design for door hinges which meets the above requirements as a minimum
may be submitted for the M.E.W. Engineer's approval.
The flange plate shall be continuously welded to the pole from inside and outside in an
approved manner and four (4) Nos. of gusset plates shall be provided. The size of the
gusset plates shall be 150 mm x 90 m x 10 mm. (Th.), which shall be continuously
welded to the body of the pole and the flange plate. The Manufacturers name,
Contract No. and date of manufacture shall be marked at the front side of the flange
plates with minimum 1 mm. deep engraving or punching.
The Contractor shall submit a guarantee from the manufacturer stating that the
designed life time of the lighting poles is for minimum twenty-five (25) years at Kuwaits
extreme weather and wind conditions stipulated and if any lighting pole fails within this
period, the same will be replaced free of charge. Without the guarantee, the lighting
poles will not be accepted.
The Contractor shall submit a guarantee from the manufacturer stating that the lantern
is well designed for proper heat dissipation at Kuwait's extreme ambient temperature
conditions of 52 degrees average and the glass cover is made from high heat resistant
tampered glass. There will be no undue temperature rise inside during operation of
the lantern leading to breaking of the glass cover, loosening/softening/melting of the
gasket and any silicon paste used for the sealing purposes of the optical assembly,
failure of degree of protection, shortening of the lamp life, damage of any other parts
of the lantern and so on. Any lantern that will undergo any such problem within a
period of five (5) years will be replaced free of charge. Without the Guarantee, the
lantern will not be accepted.
App B -Ra106 Street Lighting Dec03 Page 18
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
The Ministry of Electricity & Water reserves its full right to ask the Contractor to
provide M/s. GE, USA manufactured 1000W high pressure sodium high mast
lantern, Type-HMAA01SYA 1GSC3 for the 38m, 35m and 30m high mast lighting
units under the project and he must provide this lantern for all the high mast
units without raise of any question.
The 1000 watt high pressure sodium lamps for the 38 metre, 35 metre and 30 metre
high lighting masts shall be suitable for operation in conjunction with an auto-regulator
ballast manufactured by General Electric (G.E.) U.S.A., having the following operating
characteristics.
1000 Watts
HPS
The Contractor shall submit a guarantee from the lamp manufacturer stating that the
offered lamps will correctly and fully satisfactorily operate with an auto-regulator ballast
(GE Make) having operating characteristics as specified above.
The lamps shall be manufactured to the best modern practice and shall fully comply
with the latest relevant ANSI specifications.
The Contractor shall submit a guarantee from the manufacturer of the lamps to state
that any lamp that will fail or burn out within a period of two (2) years of operation will
be replaced free of charge. Without the guarantee, the lamps will not be accepted.
The Ministry of Electricity & Water reserves its full right to ask the Contractor to
provide M/s. GE, USA manufactured 1000W high pressure sodium lamp, Type-
LUCALOX LU1000 for the 38m, 35 m and 30m high masts under the project and
he must provide this lamp for all the high mast lighting units without raise of any
question.
14.11.01 400 Watt High Pressure Mercury Vapour Fluorescent Discharge Lanterns, Arm
Mounted
The overall dimensions of a 400 watt rated lantern must not be less than 850 mm (L) x
350 mm (W). The lanterns shall have bowl or dish type covers from glass material as
specified in Clause 14.11.01 of the Amendment No.1 to Section XIV and flat glass
covers are not acceptable.
The Contractor shall submit a guarantee from the manufacturer stating that the lantern
is well designed for proper heat dissipation at Kuwait's extreme ambient temperature
conditions of 52 degrees average and the glass cover is made from high heat resistant
tampered glass. There will be no undue temperature rise inside during operation of
the lantern leading to breaking of the glass cover, loosening/softening/melting of the
gasket and any silicon paste used for the sealing purposes of the optical assembly,
failure of degree of protection, shortening of the lamp life, damage of any other parts
of the lantern and so on. Any lantern that will undergo any such problem within a
period of five (5) years will be replaced free of charge. Without the Guarantee, the
lantern will not be accepted.
The thickness of the aluminium plate for the tripple type control gear assemblies shall
be minimum 4mm and the capacitor mounting supports for all panels shall be from
minimum 2mm thick aluminium plates.
The overall dimensions of a 400 watt rated lantern must not be less than 850 mm (L) x
350 mm (W). The lanterns shall have bowl or dish type covers from glass material as
specified in Clause 14.11.01 of the Amendment No.1 to Section XIV and flat glass
covers are not acceptable.
The Contractor shall submit a guarantee from the manufacturer stating that the lantern
is well designed for proper heat dissipation at Kuwait's extreme ambient temperature
conditions of 52 degrees average and the glass cover is made from high heat resistant
tampered glass. There will be no undue temperature rise inside during operation of
the lantern leading to breaking of the glass cover, loosening/softening/melting of the
gasket and any silicon paste used for the sealing purposes of the optical assembly,
failure of degree of protection, shortening of the lamp life, damage of any other parts
of the lantern and so on.
Any lantern that will undergo any such problem within a period of five (5) years will be
replaced free of charge. Without the Guarantee, the lantern will not be accepted
The 400W high pressure sodium lamps shall be manufactured to the European
standard practice. The lamps shall comply with the IEC Publication No. 662 and shall
be fully suitable for operation in conjunction with a Ballast having operating
characteristics as specified in this IEC, and/or IEC Publication No. 923 except that the
Rated Voltage shall be 240 volts instead of 220 volts. The lamps shall be tubular in
shape with E-40 cap and clear type. The H.P.S. lamps shall operate in conjunction with
an external ignitor and lamps with built-in ignitors will not be accepted.
The Average Rated Life or the Life Expectancy of the lamps shall be considered as
the number of burning hours at 10 hours/start which have elapsed when 50 (fifty) per
cent of lamps from a large batch have failed.
The Contractor shall submit a guarantee from the manufacturer of the lamps to state
that any lamp that will fail or burn out within a period of two (2) years of operation will
be replaced free of charge. Without the guarantee, the lamps will not be accepted.
The thickness of the aluminium plate for the tripple type control gear assemblies shall
be minimum 4mm and the capacitor mounting supports for all panels shall be from
minimum 2mm thick aluminium plates.
The performance requirements for lighting systems installed under the Contract shall
be as follows:
The above levels of lighting are the maintained values of the average road surface
luminance and illuminance. In order to maintain these levels, a depreciation
(maintenance factor) of 0.6 shall be used.
Where existing sign gantries are to be retained but the sign face panels replaced, the
Contractor shall disconnect the existing lanterns and shall install new lanterns in the
locations indicated on the Drawings. The Contractor shall include for the provision of
all necessary trunking, junction boxes, conduit, cabling etc. from the existing safety
switch to provide a complete lighting installation for the new sign face panels.
The Contractor shall inspect and test, in the presence of the Engineer, the existing
electrical circuitry to be retained and shall carry out any required repair work to the
existing installations.
The Contractor shall prepare, for the approval of the Engineer, the necessary
drawings, indicating all components, fixing details and cabling arrangements etc. All
proposals and materials shall be in accordance with the requirements of the relevant
Clauses of the Specifications.
Any damage to the galvanized finish of the sign gantries resultant from the
Contractor's operation shall be made good by the Contractor in accordance with
Clause 1401.13.3 of the Specifications.
The existing installations (lanterns, conduit, etc.) shall be abandoned unless their
removal is necessitated by installation of the new lighting facilities.
The overall dimensions of the control cabinets without canopy shall be 1700 mm (H) x
1000 mm (W) x 500 mm (D) and the sloping type canopy shall have a minimum depth
of 100 mm. at the centre. The enclosure shall be in one piece without any joint from
outside and a substantial base frame shall be provided at the bottom with all welding
from inside only. All four sides of the canopy shall be bent inside and welded
continuously with the body in an aesthetic manner. Any stitch welding for this
will not be accepted.
The control cabinet shall be provided with mounting panel and inside the feeder pillar,
a full length second door from minimum 1.5 mm. thick galvanized or electroplated
sheet steel with necessary slots for the operating knobs of the MCCBs and MCBs, to
prevent any accidental contact with bus-bars or other live material during
maintenance. The single leaf door shall be hinged to the body on its left hand side by
at least 4 Nos. of substantial stainless steel hinges and shall be closed on the right by
galv. steel captive screws.
The incoming and outgoing moulded case circuit breakers shall comply in all respects
to the IEC Publication No.947-2 and the value of the Breaking Capacities specified
shall be the Rated Service Short Circuit Breaking Capacity as per this IEC. The
electro-magnetic contactor shall fully comply to the IEC Publication No.947-4-1.
A high quality 13 Amp. power socket for maintenance and test equipment shall be
installed at an accessible location and shall be wired and connected together with a
single pole, 15 Amp. rated circuit breaker for protecting from overload. Also, one (1)
No. of 15 Amp. single pole and one (1) No. of 15 Amp. triple pole miniature circuit
breakers (MCB's) shall be provided for 24-hour power supply.
Each control cabinet shall be provided with a 120 mm. x 50 mm. non-corrosive metal
name plate at the front of the left had side door, engraved with details, like Type,
Rating, No. of outgoing ways etc. and Manufacturers Name, Ref. No. for easy
App B -Ra106 Street Lighting Dec03 Page 22
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
identification. Additionally, two (2) Nos. of 200 mm. x 150 mm. electrical danger signs
of approved type, also from non-corrosive metal plates shall be fixed on the control
cabinets, one on the right hand side door and the other at the back side of the control
cabinet.
The protective crush barrier for the control cabinets shall be constructed with steel
bollards as shown in the Contract Drawings.
As-built drawings shall be prepared with AutoCAD and submitted as indicated in the
Standard Specifications (One mother print of diaze polyester film and three white
paper prints) to the same scale as the working drawings. The Contractor shall also
submit the drawings in three (3) sets of Compact Discs. He should maintain a
continuous record of all the field deviations from the working drawings, if any, as
approved by the Engineer and shall incorporate these into the as-built drawings. The
locations of all handholes, road
ducts, routing of cables/cable ducts, their distance from the kerbsides as well as
feeding details of the feeder pillars, like Sub-station No., LT feeder, etc. shall be all
clearly indicated on the drawings. The drawings of all major items of equipment shall
also be provided together with a schedule detailing make, type rating etc. of all the
equipment and components therein. The Contractor shall also provide as-built
drawings to scale 1:2000 when asked by the Engineer.
14.25.05 Micro-Film
The Contractor shall supply the Ministry of Electricity and Water, with three (3) sets of
35 mm. Silver Halide micro-film aperture cards made from (as fitted or built) original
drawings. The front face of these aperture cards should be left blank and on the
reverse face, details like, Contractor's Name, Contract No., Project and Drawing Titles,
Drawing No., Reduction Ratio and Date shall be printed or typed directly on the cards.
Two samples of processed micro-film aperture card shall be submitted to the Ministry
for approval prior to final submission.
App B -Ra106 Street Lighting Dec03 Page 23
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
The Contractor shall prepare a complete and fully detailed inventory of each and every
item of street lighting equipment, accessories, drawings, etc. employed for the lighting
installation of the project and provide these information on computer diskettes in three
(3) complete sets.
The Contractor shall maintain the entire permanent lighting installations under the
Contract for period of TWO (2) YEARS AS A WARRANTY TO HIS WORKS from the
date of completion of the project. The maintenance works will be supervised by and
will be under the full control of the Ministry of Electricity & Water.
The Contractor shall carry out all repair works including attending to and rectifying all
faults and damage, howsoever they be caused and shall be responsible for the
replacement of all wear and tear items of all equipment. Any parts, accessories,
cables, control gears, control cabinet/feeder pillar components, lamps, fuses etc.,
which have been put out of service or otherwise damaged due to the contractors
negligence or which have failed or become defective due to material or manufacturing
faults shall be rectified and/or replaced by the contractor at no extra cost whatsoever.
The Contractor shall dismantle and transport to the Ministry of Electricity & Water store
any accidented lighting mast, pole or control cabinet/feeder pillar and collect from its
store and erect replacement mast, pole or control cabinet/feeder pillar complete with
all accessories as directed by the Engineer, all at his own expense.
Payment shall be at the rates inserted in the Bill of Quantities which rates shall include
for the reconditioning of the hoist assemblies and control equipment,
galvanization/paint repairs, cleaning of lanterns wiring and installation of new
component parts, rectification of all damage to existing equipment and thorough
cleaning of all component parts of the installation.
Reinstallation of the masts will be measured and paid off under Clause 1426.08 of the
Specifications.
Measurement for the removal of electrical cables shall be by the metre run for each
type of cable.
App B -Ra106 Street Lighting Dec03 Page 24
Particular Specification Contract RA/ 106
Construction and Maintenance of Roads, Bridges, Drainage, Sewer and other Services
for Completion of First Ring Road, Jahra Gate Roundabout - Package 1
Payment shall be at the rate inserted in the Bill of Quantities and shall include for
excavation, backfilling, provision of pulleys or other approved devices, provision of
cable drums, cutting cables, tagging and marking, delivery to the Ministry of Electricity
and Water depot and disposal or re-use of any cable tiles.
Measurement for the removal of the existing control cabinets/feeder pillars shall be by
number and payment shall be at the rate inserted in the Bill of Quantities and shall
include for all work as specified in Clause 14.01.13.6
Payment shall be at the rate inserted in the Bill of Quantities and shall include for all
work as specified in Clause 14.01.13.3.
14.26.06 Earth Bonding and Grounding
There shall be no separate measurement and/or payment for grounding of masts and
structures for lighting protection, earth bonding jumpers and earth continuity
conductors. The cost of such items of work shall be incidental to the respective
related items.
Payment shall be at the rates inserted in the Bill of Quantities which rates shall include
for conduit, junction boxes, wiring, connections and all other items necessary to
provide a complete, safe and functional installation.
The cost of cable between the circuit breaker at the pole base and lanterns shall be
incidental to that of the light mast and there shall be no separate payment for this item.
There shall be no separate measurement or payment for the PVC conduit or metal
pipe sleeves embedded in foundations and other structures at cable crossings, which
shall be incidental to the cost of the related works.
Hot dip galvanized junction boxes and those designated concrete junction boxes,
installed in bridge structures for undercrossing or sign lighting shall not be measured
or paid for separately. Cost of such boxes shall be incidental to that of related
structures.
The Contractor shall reinstate power supplies to any existing lighting installations
which are interrupted by the removal of redundant installations. This work, which shall
include the installation of through joints and the extension of existing cables as
required, shall not be measured or paid for separately but will be considered as a
subsidiary obligation of the Contractor.
14.28 Spares
Additional items for supply of spare parts for electrical equipment are enumerated in
the Bill of Quantities for Section XIV. All spare parts and units shall be suitably boxed
or crated and placed in storage with adequate protection from adverse weather, where
directed by the Employer, in Kuwait. All spare parts and units shall be identical to and
by the same manufacturer as the units approved by the Engineer for use under this
Contract.
The Contractor shall provide all labour, tools, equipment and appurtenances to
carefully load, transport, unload and place all spares in storage and ultimately to hand
over to the Ministry of Electricity and Water. No materials boxes or crates shall be
stored directly on the ground or similar horizontal surface. The Contractor shall
provide all wood or concrete blocks as approved by the Engineer under all materials,
boxes or crates. All materials, crates or boxes shall be suitably identified as spares for
Contract No. RA/106 First Ring Road.
SCHEDULE-A1
2. Shaft
a) No. of sections 4 max.
b) Length of each section
c) Overlap at joints 1.5 x dia. of
female section
5. Base plate
a) Diameter
b) Thickness 50 mm min.
* Not specified
SCHEDULE-A2
2. Shaft
a) No. of sections 4 max.
b) Length of each section
c) Overlap at joints 1.5 x dia. of
female section
5. Base plate
a) Diameter
b) Thickness 50 mm min.
* Not specified
SCHEDULE - A3
2. Shaft
a) No. of sections 3 max.
b) Length of each section
c) Overlap at joints 1.5 x dia. of
female section
5. Base plate
a) Diameter *
b) Thickness 50 mm min.
* Not specified
SCHEDULE-A4
2. Shaft
a) No. of sections 2 max.
b) Length of each section *
c) Overlap at joints 1.5 x dia. of
female section (min.)
3. Top spigot
a) Arm length 600 mm
b) External diameter of arm 60 mm
c) Arm tilt 50, 100, 150,or 200
6. Base plate
a) Size 580 mm x 580 mm
a) Thickness 40 mm
b) Foundation bolt-holes diameter 44 mm
* Not specified
SCHEDULE-A5
2. Shaft
a) No. of sections 2 max.
b) Length of each section *
c) Overlap at joints 1.5 x dia. of
female section (min.)
3. Top spigot
a) Arm length 600 mm
b) External diameter of arm 60 mm
c) Arm tilt Consistent with
rigid pole
4. Internal diameter at the
top of the pole 98 mm
6. Base plate
a) Size 370 mm x 370 mm
a) Thickness 30 mm
b) Foundation bolt-holes diameter 30 mm
d) Bolt circle diameter 380 mm
* Not specified
SCHEDULE-A6
7. Flange plate
a) dimensions 500mm x 500mm
b) thickness 30 mm
c) foundation bolt-holes 34mm x 40mm
diameter (Ellipsoidal)
9. Base-compartments ( 2 nos.)
a) Clear openings 640mm x 135mm
b) Doors 660mm x 160mm
* Not specified
SCHEDULE-B1
SCHEDULE-B2
SCHEDULE-B3
SCHEDULE B4
4. Elongation (min.)
SCHEDULE B5
4. Elongation (min.)
SCHEDULE B6
4. Elongation (min.)
SCHEDULE - C1
Item No.
SCHEDULE C2
Item No.
SCHEDULE C3
Item No.
SCHEDULE C4
Item No.
SCHEDULE C5
Item No.
SCHEDULE C6
Item No.
SCHEDULE - D1
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE - D1 (CONTD)
SCHEDULE D2
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE D2 (CONTD)
SCHEDULE D3
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE D3 (CONTD)
SCHEDULE D4
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE D4 (CONTD)
SCHEDULE D5
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE D5 (CONTD)
SCHEDULE D6
11. Total flux in the zone 60o to 70o of complete unit Lumens
SCHEDULE D6 (CONTD)
SCHEDULE - G
LAMPS
SCHEDULE H
CHOKES
1. Type
2. Wattage
3. Voltage
4. Phase
5. Voltage of Tappings
8. Name of manufacturer
and address
SCHEDULE I
CAPACITORS
1. Type
3. Type of Container
6. Name of Manufacturer
And address
SCHEDULE J
IGNITORS
1. Type
2. Wattage
6. Type of container
SCHEDULE K
Particulars
Ser. Description Unit 24-Way, 18-Way,
No. 400A 300A
1. Main MCCB
a) Make
a) Make
SCHEDULE K (CONTD)
Particulars
Ser. Description Unit 24-Way, 18-Way,
No. 400A 300A
3. Contactor:
a) Make
e) Class of duty
4. Bus-Bars:
K.A.
5. Photo-Cell:
a) Make
SCHEDULE K (CONTD)
Particulars
Ser. Description Unit 24-Way, 18-Way,
No. 400A 300A
Contactor closes in case of failure of photo-cell or not. Yes / No. Yes / No.
b) Size
c) Material
b) Terminal Material
9. Control Wires:
a) Make / Size
b) Insulation Type
c) Voltage Grade
SCHEDULE K (CONTD)
Particulars
Ser. Description Unit 24-Way, 18-Way,
No. 400A 300A
a) Housing Material
b) Overall length MM
c) Overall width MM
d) Overall depth MM
g) 350 mm (H) x 200 mm (W) empty space for Yes / No. Yes / No.
future installation of a kilowatt-hour Meter
provided?
Yes / No. Yes / No.
h) Power Socket provided?
Yes / No. Yes / No.
i) 24-hour MCBs provided?
Yes / No. Yes / No.
j) M20X400 Anchor bolts as specified provided?
C2 Setting-out Reports
APPENDIX C1
SETTING-OUT REPORTS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 12 496134 249034 499721 252046 240142 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 497404.996 249045.093 8.969 -78.788 267 58 29.7 INFINITY 0.01010 0.00000 PBT 1
2 497110.424 249034.677 11.740 215.969 267 58 29.7 2000.000 -0.00164 -3.33333 PC 2
3 496671.260 249067.668 7.370 657.265 280 37 1.6 INFINITY -0.02664 -3.84615 PT 3
4 496460.471 249107.181 -0.571 871.726 280 37 1.6 INFINITY -0.02356 3.33333 TS00 3
5 496355.651 249132.680 -1.723 979.726 289 47 4.0 337.500 -0.00674 0.00000 SC00 4
6 496171.358 249607.693 3.703 1557.119 27 48 20.7 337.500 0.03676 -3.84615 CS00 4
7 496215.960 249676.365 5.424 1639.083 36 26 25.2 1400.000 0.00524 -3.84615 SC00 5
8 496440.435 249915.661 0.581 1967.942 49 53 56.6 -907.776 -0.02812 3.33333 PRC 6
9 496627.157 250131.576 5.086 2254.586 31 48 25.3 10000.000 0.04000 0.00000 PRC 7
10 496706.099 250256.782 8.016 2402.602 32 39 18.3 INFINITY -0.00500 0.00000 PT 8
11 496866.569 250507.172 6.529 2700.000 32 39 18.3 INFINITY -0.00500 0.00000 PT 9
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 5 496134 249034 499721 252046 240142 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 7 496134 249034 499721 252046 240142 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 20 496134 249034 499721 252046 240142 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 10 496134 249034 499721 252046 240142 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 7 496134 249034 499721 252046 240142 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC00 MC00 777712 8 496134 249034 499721 252046 240142 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC02 MC02 777712 6 496304 249835 496699 250126 289177 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496698.057 249835.656 8.442 0.000 306 23 12.6 INFINITY 0.01199 -14.28571 PBT 1
2 496528.932 249960.286 7.493 210.086 306 23 12.6 -135.000 -0.00500 0.00000 PC 2
3 496528.906 249960.305 7.493 210.118 306 22 23.3 INFINITY -0.00500 0.00000 PT 3
4 496441.010 250025.044 6.827 319.282 306 22 23.3 135.000 -0.01627 3.33333 PC 4
5 496440.793 250025.204 6.823 319.551 306 29 14.4 INFINITY -0.01618 3.33333 PT 5
6 496304.542 250125.977 6.146 489.020 306 29 14.4 INFINITY 0.01111 0.00000 PAT 5
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC02 MC02 777712 4 496304 249835 496699 250126 289177 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC02 MC02 777712 2 496304 249835 496699 250126 289177 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC02 MC02 777712 6 496304 249835 496699 250126 289177 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC02 MC02 777712 2 496304 249835 496699 250126 289177 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC10
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 6 496258 249605 496453 249819 289151 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496272.240 249605.053 7.902 0.000 322 20 27.4 70.000 -0.02564 0.00000 PBC 1
2 496266.834 249682.473 6.684 82.260 29 40 17.8 400.000 -0.00126 3.33333 PCC 2
3 496305.259 249738.314 6.965 150.126 39 23 33.8 1102.400 0.00500 0.00000 PCC 3
4 496371.694 249812.162 7.508 249.492 44 33 25.8 35.000 0.01219 5.55556 PCC 4
5 496430.183 249797.576 8.763 322.119 163 26 56.1 -500.000 0.01765 0.00000 PRC 5
6 496452.280 249737.573 9.986 386.105 156 7 0.0 -500.000 0.00922 0.00000 PAC 5
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 7 496258 249605 496453 249819 289151 1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 5 496258 249605 496453 249819 289151 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 9 496258 249605 496453 249819 289151 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 6 496258 249605 496453 249819 289151 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 1 496258 249605 496453 249819 289151 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC10 MC10 777712 4 496258 249605 496453 249819 289151 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC20
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 5 496261 249703 496532 249959 289193 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 6 496261 249703 496532 249959 289193 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 4 496261 249703 496532 249959 289193 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 7 496261 249703 496532 249959 289193 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 1 496261 249703 496532 249959 289193 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC20 MC20 777712 3 496261 249703 496532 249959 289193 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC30
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 3 496474 249895 496573 249921 289200 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 4 496474 249895 496573 249921 289200 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 2 496474 249895 496573 249921 289200 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 4 496474 249895 496573 249921 289200 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 3 496474 249895 496573 249921 289200 1
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 1 496474 249895 496573 249921 289200 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC30 MC30 777712 1 496474 249895 496573 249921 289200 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC50
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 4 496311 249806 496493 249987 240868 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496492.768 249986.922 6.900 0.000 225 6 10.3 1000.000 0.00500 0.00000 PBC 1
2 496421.280 249922.249 6.554 96.438 230 37 42.2 -600.000 -0.03381 -9.09091 PRC 2
3 496335.873 249836.348 -999.000 217.779 219 2 28.5 INFINITY 0.00000 0.00000 PT 3
4 496311.745 249806.597 -999.000 256.083 219 2 28.5 INFINITY 0.00000 0.00000 PAT 3
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 4 496311 249806 496493 249987 240868 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 2 496311 249806 496493 249987 240868 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 4 496311 249806 496493 249987 240868 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 4 496311 249806 496493 249987 240868 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 2 496311 249806 496493 249987 240868 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC50 MC50 777712 2 496311 249806 496493 249987 240868 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC60
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC60 MC60 777712 3 496534 249956 496676 250191 289229 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC60 MC60 777712 1 496534 249956 496676 250191 289229 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC60 MC60 777712 4 496534 249956 496676 250191 289229 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC60 MC60 777712 4 496534 249956 496676 250191 289229 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC60 MC60 777712 2 496534 249956 496676 250191 289229 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC70
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 4 496492 249986 496660 250201 289244 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 4 496492 249986 496660 250201 289244 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 2 496492 249986 496660 250201 289244 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 4 496492 249986 496660 250201 289244 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 4 496492 249986 496660 250201 289244 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 2 496492 249986 496660 250201 289244 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC70 MC70 777712 2 496492 249986 496660 250201 289244 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
MC90
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 4 496631 250095 496900 250485 289264 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 4 496631 250095 496900 250485 289264 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 2 496631 250095 496900 250485 289264 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 9 496631 250095 496900 250485 289264 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 7 496631 250095 496900 250485 289264 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 4 496631 250095 496900 250485 289264 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC90 MC90 777712 5 496631 250095 496900 250485 289264 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496265.742 249193.659 -2.666 0.000 316 58 13.4 INFINITY -0.00888 0.00000 PBT 1
2 496253.317 249206.970 -2.828 18.209 316 58 13.4 310.000 -0.00888 0.00000 PC 2
3 496196.748 249292.375 -3.742 121.122 335 59 28.5 360.000 -0.00888 0.00000 PCC 3
4 496208.399 249609.092 6.078 449.299 28 13 20.3 INFINITY -0.01147 0.00000 PT 4
5 496230.528 249650.324 5.541 496.094 28 13 20.3 INFINITY -0.01147 0.00000 PAT 4
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 4 496165 249193 496266 249651 289054 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 2 496165 249193 496266 249651 289054 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 6 496165 249193 496266 249651 289054 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 4 496165 249193 496266 249651 289054 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 2 496165 249193 496266 249651 289054 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC14 MC14 777712 2 496165 249193 496266 249651 289054 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC24 MC24 777712 5 495712 248941 496459 249122 240739 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC24 MC24 777712 3 495712 248941 496459 249122 240739 1
VTPS
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC24 MC24 777712 7 495712 248941 496459 249122 240739 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC24 MC24 777712 4 495712 248941 496459 249122 240739 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
END OF REPORT-------------------------------------------------------------------
MC34
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 3 497086 249011 497275 249025 289129 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 3 497086 249011 497275 249025 289129 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 1 497086 249011 497275 249025 289129 1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 4 497086 249011 497275 249025 289129 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 4 497086 249011 497275 249025 289129 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 1 497086 249011 497275 249025 289129 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC34 MC34 777712 2 497086 249011 497275 249025 289129 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC44
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 7 495730 248982 497381 249218 240759 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 5 495730 248982 497381 249218 240759 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 3 495730 248982 497381 249218 240759 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 15 495730 248982 497381 249218 240759 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 10 495730 248982 497381 249218 240759 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 3 495730 248982 497381 249218 240759 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC44 MC44 777712 8 495730 248982 497381 249218 240759 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC54
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 8 496428 249009 497177 249090 289139 1
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 6 496428 249009 497177 249090 289139 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 4 496428 249009 497177 249090 289139 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 8 496428 249009 497177 249090 289139 1
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 6 496428 249009 497177 249090 289139 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 1 496428 249009 497177 249090 289139 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC54 MC54 777712 4 496428 249009 497177 249090 289139 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC64
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 8 495472 248793 496119 249458 288977 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 3 495472 248793 496119 249458 288977 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 3 495472 248793 496119 249458 288977 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 5 495472 248793 496119 249458 288977 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 4 495472 248793 496119 249458 288977 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 2 495472 248793 496119 249458 288977 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC64 MC64 777712 2 495472 248793 496119 249458 288977 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC74
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 9 495477 248787 496261 249719 289000 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 3 495477 248787 496261 249719 289000 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 3 495477 248787 496261 249719 289000 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 11 495477 248787 496261 249719 289000 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 7 495477 248787 496261 249719 289000 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 4 495477 248787 496261 249719 289000 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC74 MC74 777712 5 495477 248787 496261 249719 289000 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC84
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC84 MC84 777712 3 496887 249052 497137 249071 289122 1
1 497136.724 249070.626 11.770 0.000 264 21 34.0 INFINITY -0.00535 0.00000 PBT 1
2 497027.192 249059.807 11.181 110.066 264 21 34.0 1500.000 -0.00535 0.00000 PC 2
3 496887.577 249052.565 9.340 249.919 269 42 5.2 1500.000 -0.00829 0.00000 PAC 2
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC84 MC84 777712 3 496887 249052 497137 249071 289122 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC84 MC84 777712 1 496887 249052 497137 249071 289122 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC84 MC84 777712 5 496887 249052 497137 249071 289122 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC84 MC84 777712 2 496887 249052 497137 249071 289122 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC94
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 4 496090 249254 496262 249704 289011 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 2 496090 249254 496262 249704 289011 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 6 496090 249254 496262 249704 289011 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 4 496090 249254 496262 249704 289011 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 2 496090 249254 496262 249704 289011 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC94 MC94 777712 2 496090 249254 496262 249704 289011 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
END OF REPORT-------------------------------------------------------------------
MC09
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 4 496341 249092 496445 249197 241911 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496362.999 249196.389 6.636 0.000 206 53 12.3 INFINITY -0.00580 0.00000 PBT 1
2 496341.263 249153.521 6.357 48.064 206 53 12.3 -47.008 -0.00580 0.00000 PC 2
3 496425.174 249111.118 6.650 195.872 26 43 50.2 INFINITY 0.00730 0.00000 PT 3
4 496444.729 249149.948 6.968 239.348 26 43 50.2 INFINITY 0.00730 0.00000 PAT 3
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 3 496341 249092 496445 249197 241911 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 1 496341 249092 496445 249197 241911 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 4 496341 249092 496445 249197 241911 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 3 496341 249092 496445 249197 241911 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 1 496341 249092 496445 249197 241911 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC09 MC09 777712 1 496341 249092 496445 249197 241911 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC04
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 2 496090 249384 496205 249494 242066 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496204.485 249384.152 6.717 0.000 313 42 32.2 75000.667 0.00357 0.00000 PBC 1
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 3 496090 249384 496205 249494 242066 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 1 496090 249384 496205 249494 242066 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 4 496090 249384 496205 249494 242066 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 3 496090 249384 496205 249494 242066 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 1 496090 249384 496205 249494 242066 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC04 MC04 777712 1 496090 249384 496205 249494 242066 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC11
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 4 496574 250100 496650 250260 241728 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 2 496574 250100 496650 250260 241728 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 4 496574 250100 496650 250260 241728 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 4 496574 250100 496650 250260 241728 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 1 496574 250100 496650 250260 241728 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC11 MC11 777712 2 496574 250100 496650 250260 241728 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC71
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 3 495858 248959 495918 249004 241855 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 495917.205 248959.436 4.690 0.000 317 35 14.3 INFINITY -0.00369 0.00000 PBT 1
2 495885.339 248994.318 4.515 47.246 317 35 14.3 -30.000 -0.00369 0.00000 PC 2
3 495858.443 249003.707 4.613 76.929 260 53 48.1 -30.000 0.01416 7.69231 PAC 2
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 3 495858 248959 495918 249004 241855 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 1 495858 248959 495918 249004 241855 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 3 495858 248959 495918 249004 241855 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 3 495858 248959 495918 249004 241855 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 1 495858 248959 495918 249004 241855 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC71 MC71 777712 1 495858 248959 495918 249004 241855 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MC91
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 4 495699 248911 495890 248988 241867 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 495889.874 248987.892 4.491 0.000 250 59 10.4 450.001 0.00500 0.00000 PBC 1
2 495854.960 248977.422 4.634 36.460 255 37 42.3 -400.000 0.00187 0.00000 PRC 2
3 495789.216 248954.310 4.764 106.237 245 38 1.0 -2000.000 0.00187 0.00000 PCC 3
4 495699.805 248911.109 4.693 205.547 242 47 18.9 -2000.000 -0.00418 0.00000 PAC 3
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 5 495699 248911 495890 248988 241867 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 3 495699 248911 495890 248988 241867 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 6 495699 248911 495890 248988 241867 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 4 495699 248911 495890 248988 241867 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 1 495699 248911 495890 248988 241867 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GC91 MC91 777712 2 495699 248911 495890 248988 241867 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
MCA0
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 6 495908 248920 496332 249105 241899 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 495955.379 248920.891 -999.000 0.000 318 38 57.3 750.000 0.00000 0.00000 PBC 1
2 495913.131 248973.487 4.648 67.486 323 48 17.1 25.000 0.00557 7.69231 PCC 2
3 495924.686 249011.717 4.671 113.747 69 49 42.0 1995.000 -0.00300 0.00000 PCC 3
4 496262.672 249103.149 5.899 464.333 79 53 49.3 180.000 0.00444 0.00000 PCC 4
5 496313.138 249104.946 6.124 514.998 96 1 27.5 30.000 0.00444 0.00000 PCC 5
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 7 495908 248920 496332 249105 241899 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 5 495908 248920 496332 249105 241899 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 7 495908 248920 496332 249105 241899 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 6 495908 248920 496332 249105 241899 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 4 495908 248920 496332 249105 241899 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCA0 MCA0 777712 4 495908 248920 496332 249105 241899 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
MCD0
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 3 496126 249267 496214 249360 242004 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
1 496213.295 249359.735 6.340 0.000 231 3 54.9 INFINITY -0.00315 0.00000 PBT 1
2 496140.929 249301.270 6.330 93.032 231 3 54.9 -40.000 -0.00500 0.00000 PC 2
3 496126.187 249267.050 6.136 131.791 175 32 51.4 -40.000 -0.00500 0.00000 PAC 2
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 3 496126 249267 496214 249360 242004 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 1 496126 249267 496214 249360 242004 1
VTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 4 496126 249267 496214 249360 242004 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 2 496126 249267 496214 249360 242004 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCD0 MCD0 777712 2 496126 249267 496214 249360 242004 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
END OF REPORT-------------------------------------------------------------------
MCF0
HTPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 4 496014 249598 496135 249639 242027 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----B------ -----R------ -----G----- --M-VALUE--- HCOD HNAM
HIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 3 496014 249598 496135 249639 242027 1
HCEN
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 1 496014 249598 496135 249639 242027 1
VTPS
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
VIPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 4 496014 249598 496135 249639 242027 1
POINT -----X------ -----Y------ -----Z----- -----C------ Grad % Diff- ---Vert R--- --M-VALUE--- VCOD
VFPS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 2 496014 249598 496135 249639 242027 1
POINT -----X------ -----Y------ -----Z----- -----C------ ---Vert R--- --M-VALUE--- VCOD VNAM
VMOS
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
GCF0 MCF0 777712 2 496014 249598 496135 249639 242027 1
POINT -----X------ -----Y------ -----Z----- -----C------ -----G------ ---Vert R--- --M-VALUE--- VCOD VNAM
999
END OF REPORT-------------------------------------------------------------------
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MBJ1 7706 13 496628 250209 496636 250215 290053 73
999
END OF REPORT-------------------------------------------------------------------
MC19
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC19 GC19 7706 15 496331 249057 496359 249097 290237 1
999
END OF REPORT-------------------------------------------------------------------
MC21
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC21 GC21 7706 20 496693 250130 496709 250190 290058 1
END OF REPORT-------------------------------------------------------------------
MC29
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC29 GC29 7706 13 496391 249059 496413 249078 290242 1
999
END OF REPORT-------------------------------------------------------------------
MC39
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC39 GC39 7706 54 496320 249070 496452 249200 294302 1
999
END OF REPORT-------------------------------------------------------------------
MC41
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC41 GC41 7706 18 496935 248859 496943 249004 241754 1
999
END OF REPORT-------------------------------------------------------------------
MC51
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC51 GC51 7706 11 496707 249017 496728 249026 290109 1
999
END OF REPORT-------------------------------------------------------------------
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC52 GC52 7706 7 496700 249021 496708 249029 290113 1
999
END OF REPORT-------------------------------------------------------------------
MC53
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC53 GC53 7706 7 496691 249019 496696 249031 290117 1
999
END OF REPORT-------------------------------------------------------------------
MC54
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC54 GC54 7706 10 496672 249023 496687 249035 290121 1
999
END OF REPORT-------------------------------------------------------------------
999
END OF REPORT-------------------------------------------------------------------
MC62
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC62 GC62 7706 9 496588 249041 496603 249052 290129 1
999
END OF REPORT-------------------------------------------------------------------
MC63
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC63 GC63 7706 5 496607 249040 496611 249048 290133 1
999
END OF REPORT-------------------------------------------------------------------
MC64
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC64 GC64 7706 4 496611 249040 496617 249046 290137 1
999
END OF REPORT-------------------------------------------------------------------
MC82
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC82 GC82 7706 5 495544 248808 495545 248818 289044 1
999
END OF REPORT-------------------------------------------------------------------
MC83
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MC83 GC83 7706 5 495523 248799 495533 248804 289048 1
999
END OF REPORT-------------------------------------------------------------------
MCB0
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MCB0 GCB0 7706 8 496186 249063 496193 249094 290265 1
999
END OF REPORT-------------------------------------------------------------------
MCC0
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MCC0 GCC0 7706 12 496011 249077 496034 249087 290298 1
999
END OF REPORT-------------------------------------------------------------------
MCJ0
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MCJ0 GCJ0 7706 12 496624 250216 496645 250243 290051 1
999
END OF REPORT-------------------------------------------------------------------
MCK0
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MCK0 GCK0 7706 32 495980 249640 496020 249781 242060 1
999
END OF REPORT-------------------------------------------------------------------
MCX1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MCX1 GCX1 7706 32 496640 249760 496681 249860 240975 1
999
END OF REPORT-------------------------------------------------------------------
MR10
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR10 7706 64 496565 249939 496582 249995 289233 1
999
END OF REPORT-------------------------------------------------------------------
MR11
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR11 7706 15 496283 249702 496296 249706 289161 1
999
END OF REPORT-------------------------------------------------------------------
MR12
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR12 7706 13 496293 249710 496298 249720 289158 1
999
END OF REPORT-------------------------------------------------------------------
MR13
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR13 7706 15 496336 249769 496348 249773 289164 1
999
END OF REPORT-------------------------------------------------------------------
MR14
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR14 7706 11 496347 249774 496350 249784 289167 1
999
END OF REPORT-------------------------------------------------------------------
MR20
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR20 7706 73 496437 249947 496454 250010 289215 1
999
END OF REPORT-------------------------------------------------------------------
MR21
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR21 7706 19 496677 250158 496692 250163 290064 1
999
END OF REPORT-------------------------------------------------------------------
MR40
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR40 7706 41 496953 248978 496980 249003 290075 1
END OF REPORT-------------------------------------------------------------------
MR43
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR43 7706 33 496912 248984 496932 249006 290084 109
999
END OF REPORT-------------------------------------------------------------------
MR44
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR44 7706 8 496927 248979 496932 248985 290092 1
999
END OF REPORT-------------------------------------------------------------------
MR45
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR45 GR44 7706 9 497316 249092 497366 249102 240780 1
999
END OF REPORT-------------------------------------------------------------------
MR55
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR55 7706 27 496412 249077 496437 249082 290254 1
999
END OF REPORT-------------------------------------------------------------------
MR71
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR71 7706 21 496832 250387 496836 250406 290149 1
999
END OF REPORT-------------------------------------------------------------------
MR72
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR72 7706 21 496815 250377 496832 250383 290146 1
999
END OF REPORT-------------------------------------------------------------------
MR7A
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR7A 7706 19 496489 250006 496505 250011 289254 1
999
END OF REPORT-------------------------------------------------------------------
MR7X
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
999
END OF REPORT-------------------------------------------------------------------
MR7Z
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR7Z 7706 11 495720 248910 495724 248919 290209 25
999
END OF REPORT-------------------------------------------------------------------
MR81
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR81 7706 21 495513 248791 495532 248796 289036 1
999
END OF REPORT-------------------------------------------------------------------
MR82
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR82 7706 22 495551 248803 495558 248822 289039 1
999
END OF REPORT-------------------------------------------------------------------
MR9L
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR9L 7706 17 495871 248985 495877 248998 290191 1
999
END OF REPORT-------------------------------------------------------------------
MR9R
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MR9R 7706 16 495881 248977 495894 248982 290194 1
999
END OF REPORT-------------------------------------------------------------------
MRB1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRB1 7706 25 496168 249072 496187 249085 290268 1
999
END OF REPORT-------------------------------------------------------------------
MRB2
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRB2 7706 25 496194 249074 496206 249093 290272 1
999
END OF REPORT-------------------------------------------------------------------
999
END OF REPORT-------------------------------------------------------------------
MRD1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRD1 7706 23 496113 249256 496123 249275 290325 1
999
END OF REPORT-------------------------------------------------------------------
MRD2
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRD2 7706 18 496133 249279 496144 249289 290328 1
999
END OF REPORT-------------------------------------------------------------------
MRD3
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRD3 7706 11 496191 249346 496198 249354 290331 1
999
END OF REPORT-------------------------------------------------------------------
MRD4
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRD4 7706 39 496183 249331 496217 249346 290334 1
999
END OF REPORT-------------------------------------------------------------------
MRF1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRF1 7706 22 496005 249616 496023 249623 290352 1
999
END OF REPORT-------------------------------------------------------------------
MRFI
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRFI 7706 20 496020 249595 496026 249612 290355 1
999
END OF REPORT-------------------------------------------------------------------
999
END OF REPORT-------------------------------------------------------------------
MRH2
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRH2 7706 11 496126 249613 496136 249617 290358 1
999
END OF REPORT-------------------------------------------------------------------
MRJ1
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRJ1 7706 80 496947 250434 496994 250482 139135 1
999
END OF REPORT-------------------------------------------------------------------
MRJ2
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRJ2 7706 19 496999 250523 497012 250535 139140 1
999
END OF REPORT-------------------------------------------------------------------
MRJ3
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRJ3 7706 28 496904 250495 496918 250544 139155 1
999
END OF REPORT-------------------------------------------------------------------
MRJ4
NAME SUBREF CONTENTS NO.PTS X -MIN Y -MIN X -MAX Y -MAX RECORD LOC.
MRJ4 7706 35 496924 250509 496945 250544 139154 1
999
END OF REPORT-------------------------------------------------------------------