h) Minimum flue gas exit 50C above acid dew point of flue gas.
temperature (for complete
range of specified fuels)
i) Air leakage (at 100% 10% of the flue gas weight entering air-
TMCR load for complete heater.
range of coals)
ii) For meeting the requirement of rated coal/ air mixture temperatures at
burner inlet at part load operations of steam generator with coals of
excessive moisture and under conditions of low ambient temperatures,
economizer bypass duct may be provided along with necessary dampers,
expansion joints, structures etc. Even in case economizer bypass is
provided, the sizing of air preheaters shall ensure that the rated mill
outlet temperatures are achieved, for complete range of specified coals,
with economizer bypass fully closed.
iii) APH inlet/ outlet flue gas/ air ducts shall have aerodynamic design for
even distribution of air/ flue gas at all loads.