Anda di halaman 1dari 24

Natural Gas Regulators

Pressure Regulators Relief Valves Slam Shuts Remote Operations Control

Fisher-Francel Regulators
ON THE COVER
Fisher-Francel Natural Gas products shown are
Types 627, 299 (center), 399A-161EB, FloBoss 500
and OSE with slam shut.
Our pledge to you...
Since the birth of the natural gas industry, Fisher Controls has been a leader in regulator
product design, engineering applications support, value for the dollar and customer
satisfaction. Today, no other regulator manufacturer in the world offers more products and
services dedicated to the natural gas industry than Fisher.

With the most complete line of pressure regulators and a worldwide distribution network,
Fisher has the products you need in stock locally, ready for delivery or shipment directly
from a Fisher factory. Our global capabilities include an experienced sales and support
team consisting of more than 2,000 technical experts available to serve you from nearly
200 offices throughout the world. Wherever you are, you can count on the Fisher
commitment to product integrity, reliability, safety and performance and a level of
support that no other supplier can equal.

Call on Fisher to help you enhance your asset management strategy by reducing inventory
and other cost-effective measures. Even your toughest natural gas regulation challenges
are no match for Fisher equipment, local service and support. At any time, anywhere in
the world, Fisher can help you manage your process better.

Fisher-Francel Regulators

1
Table of Contents

Information
Whats New . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3 S200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Y600 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
Premier products from wellhead to pilot light . . . . . . . . .4 Y690 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12
67 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1301F/G Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Delivery . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
64 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
1367 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
A worldwide network of sales support
and supplies . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5 Slam Shuts
299SO . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
Certification and the Quality standards of S208/S209 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
ISO 9001, DVGW, CEN and Fisher . . . . . . . . . . . . . . . . . . . . .5
Relief
Cost-effective training 252 Filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
289 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14
for cost-effective solutions . . . . . . . . . . . . . . . . . . . . . . . . . .6
289P-6358 or 289P-6365 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
1805 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Flow measurement and control . . . . . . . . . . . . . . . . . . . . . .6 1805P-6358 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
1808 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Fisher-Francel, world leaders in regulators . . . . . . . . . . .7 H100/H200 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
63EG Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
66R & 66RR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
414 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Regulators and Products
Pressure
Francel
299 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
ASOFLEX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
1098-EGR . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
B Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
99 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
CMAX . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
399A-161EB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
DRPN . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
627 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
OSE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
627F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
MPS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
310-32A . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
ROD AGNI . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
630 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
REGAL 2 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .18
133 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Transmission Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
133HP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Distribution Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
66 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Cabinets / Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
S402 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Service Pits . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
S102C . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
S252/S254 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
Regulator/Relief Selection Table . . . . . . . . . . . . . . . . . . . .20
399A-6365/6358 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
S300 Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
S301F/D Series . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12

2
Whats New
299 SERIES 399A-161EB

These pressure reducing regulators This new, high performance


are especially suited for fixed factor pressure reducing regulator
or PFM applications requiring high provides increased accuracy as
accuracy. well as higher setpoints.
(page 8) (page 8)

133HP S102C

This direct-operated regulator is A direct-operated, spring loaded


ideal for district regulator use, regulator which provides higher
monitors, and industrial and relief capacity in a variety of
commercial applications. residential, commercial and
(page 10) industrial applications.
(page 11)

299SO S208/S209

This regulator is the same as the Quick reacting pressure reducing


299 Series with the addition of VSX regulators with the Type VSX Slam-
Slam-Shut technology. Shut module. They are typically
(page 14) used for industrial or commercial
applications where use of relief
valves is not an option.
(page 14)

252 FILTER OSE

Available in stainless steel or The OSE Slam-Shut is used to


aluminum construction to provide totally and rapidly cut the gas flow
micron filtration for various when network pressure is too high
applications in the natural gas and/or too low.
industry. (page 18)
(page 14)

3
Premier products
from wellhead to pilot light

From the industrys premier supplier. Delivery.


Fisher Controls offers more regulators and relief valves than any For the right regulator at the right time, Fisher delivers. At any
other manufacturer in the world. From regulators that handle given time, the Fisher Controls Representative Network has
high pressure gas flows to low pressure house service more regulators in stock than most regulator manufacturers can
applications, you can trust that Fishers resources, engineering ship in a total year. Fisher will also supply any product (up to 80
expertise, industry experience and dedication to quality ensure percent of our product line) on an overnight basis if youre
maximum profitability for gas utility customers. needing it in an emergency. For streamlining or reducing
inventory, rely on Fisher to establish monthly or even more
As a Fisher customer, you will find that our natural gas frequent shipments. Because our people and systems are
regulators and relief valves incorporate only the latest in geared to meeting your requirements on time, your best source
high-tech engineering technology. Many of our regulators, such for natural gas regulators is your local Fisher Representative.
as the 630 Series, 99 Series and Type 61 pilot have become
industry standards for performance and extended service life.

New products to meet your changing needs.


In order to best meet customers needs, Fisher is always
updating and expanding its regulator line. On page three of this
brochure youll find our Whats New section, featuring several
new products for a variety of applications.

4
A worldwide network of sales support and supplies
With over 2,000 technical experts to serve you from nearly 200
locations throughout the world, the Fisher sales and service
network is one of the largest in the industry. Whether you need
an emergency replacement regulator or are working on a
utilitys long-range plan for growth and expansion, our
Representatives respond quickly and professionally. This kind of
sales support, combined with a dedication to pursuing the latest
in advanced technology for all our products, makes Fisher the
recognized leader in regulator supplies by the natural gas
industry.

No matter what type of application problem or question you


have, Fisher is your regulator resource. The majority of our
applications personnel are degreed engineers, specialists in
specifying pressure regulator solutions. Our Representatives are
dedicated to providing the products and services that help you
reach your goals, including a comprehensive training program
available locally or at Fisher facilities. Total support before Product schematics and other technical documentation for all
and after the sale is what youll find at Fisher. the products listed in this brochure are available in electronic
form on the Fisher Controls Regulator Division Literature
CD-ROM. For your free copy of the CD or printed copies of
State-of-the-art products. Individually tested. technical documentation, call 1-800-558-5853. You can also
Fisher regulator and relief valve manufacturing facilities are e-mail your request to fisher.regulators@frco.com.
equipped with the latest in technology. Excellence in
engineering is the hallmark of our manufacturing procedures. Fisher Controls Regulator Division
Marshalltown IA 50158 USA
Each Fisher regulator or relief valve is individually tested prior to (515) 754-3741 (515) 754-3081 (fax)
shipment to ensure that it will perform exactly to customer www.fisher.com/regulators (Internet)
specifications. We continuously improve our ability to produce fisher.regulators@frco.com (e-mail)
the highest quality regulators available on the market today.
And Fisher probably has the items you need in local stock or
ready for immediate shipment from a Fisher factory.

The quality standards of Fisher


CertificationISO 9001.
Improving the quality of our products while increasing customer Currently all Fisher regulator manufacturing and design facilities
satisfaction has always been the priority at Fisher. Thats why are ISO 9001 Certified.
we are proud to bring our customers products that consistently
meet the rigorous standards of quality assuranceISO 9001
Certification. ISO 9001 standards require that: DVGW, CEN and Fisher.
an effective quality assurance system is in place, In Europe, Fisher is presently involved in and has received DVGW
equipment is properly calibrated and maintained, registration and is pursuing CEN approval for various regulator
proper records are kept, products. DVGW registration signifies that registered products
product handling and storage systems are adequate, meet common Natural Gas Industry standards. This registration
and personnel training and experience are up to par. is also recognized by users outside the European gas industry.

5
Cost-effective training for cost-effective solutions
Fisher-Rosemount Educational Services works closely with the
gas utilities industry, providing extensive know-how and natural
gas regulator application training.

The range of training includes an annual Gas Industry Conference,


regularly scheduled factory training relative to natural gas regulator
installation and maintenance, Remote Operations Controllers
(ROC), FloBoss and on-site training. The course instruction
covers product application and regulation, as well as measurement
instrumentation and studies on PROVOX Distributed Control
Systems and other process and application topics.

Training for natural gas regulation topics and more is available at


all of our North America Regional Training Centers, or on-site at
your facility. In addition, self-training programs including videos,
Because we at Fisher take training so seriously, certified workbooks, tests and computer-based training are available to
instructors in our Fisher-Rosemount Educational Services division keep your staff as current and proficient as possible in all new
offer a variety of courses to gas industry personnel. and mature technologies.

Flow measurement and control for the gas industry


Fishers family of Remote Operations Controllers (ROCs) and To make field automation projects easier, Fisher and its
FloBoss Flow Computers are designed to meet the wide- Representatives have teamed to create the ROC Integration
ranging measurement and control needs of the natural gas Network. The Network has access to hundreds of proven field
industry. These powerful products are ideally suited to automation solutions, developed from a worldwide installed base
applications at wellheads, meter runs, custody transfer stations, of over 10,000 FAS products serving a wide range of applications.
compressor stations and gate stations. They provide on-site,
round-the-clock monitoring, measurement, totalizing, alarming,
communications and control.

Using the latest microprocessor technology, these products stand


alone or network to a data gathering system. Monitored values
are processed and stored for easy access by personnel in the
field, or can be relayed through telephone, radio, or satellite
transmissions to supervisors and managers at regional and
corporate offices. System integration is simplified because they
are designed to operate with many popular host software
packages.

Both ROC and FloBoss product families feature advanced


hardware and software that make them simple to configure and
operate, easy to customize to the application, modular for faster
upgrading and expansion, and versatile for better integration into
host systems. Built into each unit are AGA flow calculations, PID
control and logic/sequencing control to meet almost any
measurement and control need.

6
World Leaders in Regulation Equipment
Fisher-Francel Regulators
With over 130 combined years of expertise, Fisher Controls and
Francel are the worlds leading providers of pressure regulation
equipment for the natural gas industry for both industrial and
residential use. The addition of Francel to the Fisher team has
expanded Fishers total product line and provided additional
manufacturing, training and service facilities in more parts of the
world than ever before. This broad line of products, from
transmission through distribution, includes regulators, relief
valves, skids and cabinets, and remote operations controllers in
a variety of sizes, materials and configurations to match almost
any application.

Francel expertise, including slam shut technology, innovations in


natural gas skid design and experience with state-owned utilities Fisher and Francel products have been engineered and
in many countries, is the perfect complement for Fisher manufactured to meet and exceed the highest international
Controls. In addition to product reliability and local service standards, providing a wide diversity of regulator products for
throughout the world, Fisher-Francel products are manufactured natural gas applications such as power generation, primary fuel
in facilities certified to ISO 9001 standards, and selected for major industries, heating large facilities such as schools and
products are DVGW-certified for European applications. hospitals, and service to homes, just to name a few.

In addition to traditional Fisher service, support, education and


training, Francel also provides educational opportunities at its in-
house training center in Gallardon, France. There, customers
increase their knowledge and learn more about utilizing products
through a combination of theoretical and practical work under
the close supervision of highly trained course leaders.

7
Pressure
D C/I FF DF C D C/I FF DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299 TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1098-EGR


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/2, 2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6, 8 x 6, 12 x 6-inch
Reduced Pressure Ranges (8) . . . . .3-1/2-inches wc - 35 psig (9 mbar - 2,4 bar) Reduced Pressure Ranges (10) . . . . . 2-inches wc - 300 psig (5 mbar - 20,7 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .400 psig (28 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:299 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:1098-EGR
The Type 299 pressure reducing regulator has a wide variety of applications, For accurate control of high capacity gas flow applications, the 1098-EGR has a
including natural gas distribution systems, gas supply to industrial boilers, Type 1098 diaphragm actuator and spring-to-close Design EGR main valve.
furnaces, ovens, mixers, plant air service and has PFM and fixed factor Trim parts can be changed without having to remove the body or actuator
capabilities. The Type 299 is not an adaptation of existing regulators; instead, it from the line. Excellent choice for low-pressure drop applications.
has a new design of integrated cases and internal registration ports. Now
available with token relief (Type 299TR).

T C D C/I FF T C D F C/I DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .99 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .399A-161EB


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .(16 sizes) from 1-12 x 6-inch
Reduced Pressure Ranges (9) . . . . . . .2-inches wc - 100 psig (5 mbar - 6,9 bar) Reduced Pressure Ranges (8) . . . . .5-inches wc - 700 psig (12 mbar - 48,3 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1,000 psig (69 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,050 psig (72,4 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:99 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:399A-161
For accurate control over widely varying flow rates and supply pressure, the The Type 399A-161EB, shown with the Type 252 filter, is a pressure reducing
pilot-operated Type 99 eliminates the need for pressure-compensating meters regulator commonly used in city or district gates and low-pressure commercial
by holding a steady pressure from the high-pressure gas main to the meter meters. Top entry design allows for in-line inspection and maintenance. The
inlet and offers versatile pressure ranges at flow capacity. Type 161EB pilot is similar to the Type 161, but has a taller spring case which
provides higher accuracy.

8
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED
F FARM TAP A INSTRUMENT AIR

T F C/I DF D F C/I FF DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .627F


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 1, 2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 1, 2-inch
Reduced Pressure Ranges (6) . . . . . . . . . . . . . . . . . .5 - 500 psig (0,34 - 34,5 bar) Outlet Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . 5 - 100 psig (0,34 - 6,9 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,000 psig (138 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 250 psig (17,2 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:627 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:627F
The Type 627 Series of Farm Tap regulators offer easy in-line maintenance and For accurate pressure control, the Type 627F has a factory-installed Type 6351F
installation. A rubber cap relief operation indicator pops off when the internal pilot. The regulator spring case can be rotated in any of four positions and is
relief valve opens, indicating that the valve has opened since the last inspection. an excellent choice for fixed-factor applications.

T C D C/I DF T F

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .310A-32A TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .630


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4 x 6-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2-inch
Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . .10 - 600 psig (0,69 - 41,4 bar) Reduced Pressure Ranges (10) . . . . . . . . . . . . . . . . .3 - 500 psig (0,21 - 34,5 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,480 psig (102 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,500 psig (103 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:310A Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:630
This pilot-operated regulator includes a Type 32A pilot assembly for pressure- The Type 630 Big Joe direct-operated regulators are available in either spring-
reducing or wide-open monitoring applications, or two pilots for working loaded or pressure-loaded constructions. A main feature is a wide range of
monitor usage on main gas pipelines. Fast response and accurate enough for flow capabilities. Main uses are in farm tap and first-stage reduction on high
turbine start-up and fuel supply applications. pressure transmission lines.

9
Pressure
D C/I D C/I

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .133HP


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch
Reduced Pressure Ranges (9) . . . . . . . 2-inches wc - 10 psig (5 mbar- 0,69 bar) Reduced Pressure Ranges (7) . . . . . . . . . . . . . . . . . . . .2 - 60 psig (0,14- 4,1 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .60 psig (4,1 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:133 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:133
The Type 133 Series offers a balanced single port design which eliminates the The Type 133HP self-operated regulator is ideal for the high-pressure, large
necessity for seat-to-seat adjustments for bubble-tight shutoff. The valve seat, capacity loads of district regulator use and for industrial and commercial
disc and cage can be easily removed for inspection without having to remove applications supplying gas to furnaces, burners, and ovens. A balancing
the body from the service line. Applications include supplying gas to furnaces, system enables the regulator to control gas pressure accurately for maximum
burners and other appliances. combustion efficiency despite varying inlet pressure.

C/I C/I FF H

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .66 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S402


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3- to 4-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . .34 x 3/4, 3/4 x 1, 1 x 1-inch
Reduced Pressure Ranges (6) . . . . . . . . . . .2-inch wc - 5 psig (4.98 - 345 mbar) Reduced Pressure Ranges (6) . . . .4-1/2-in. wc - 2.5 psig (11,2 mbar - 0,17 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 psig (0,69 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Cast Iron
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:66 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S402
The direct-operated Type 66 Series offers precise control of low-pressure The control accuracy of the Type S402 Series provides fixed-factor billing
industrial gases, as well as a broad range of downstream demand situations. capabilities throughout the available spring ranges and is specifically
The Series is available in both vacuum regulator and vacuum breaker applicable for use in piping systems within the natural gas industry.
constructions. Flow capacities range up to 187,000 Scfh [5,012 m3/h(n)].
Applications include burner control and tank blanketing.

10
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED
F FARM TAP A INSTRUMENT AIR

H C/I H

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S102C TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . .S252/S254 SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4, 1, 1-1/4, 1-1/2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 1-inch
Reduced Pressure Ranges (5) . . . . . .3-1/2 -in. wc - 2.5 psig (8 mbar - 0,17 bar) Reduced Pressure Ranges (6) . . . . . . .3-1/2-in. wc - 2.5 psig (9 mbar - 0,17 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S100C Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S250
The Type S102C is a self-operated, spring loaded regulator that provides Designed primarily as a house service regulator for domestic gas installations,
economical pressure-reducing control in a variety of residential, commercial the S252/S254 Series is available in versions with high capacity relief. Easy
and industrial applications. The Type S102C has internal relief across the access to the orifice and valve disc allows for easy maintenance and
diaphragm to help minimize overpressure. combines well with 175 and 250 meters. Available in either angle or meter bar
body style. Diaphragm and valve disc are made of Nitrile.

C/I DF C/I FF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . .399A-6365/6358 TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .S300 SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .(16 sizes) from 1-12 x 6-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-14, 1-12, 2-inch
Relief Set Pressure Ranges (5) . . . . . . . . . . . . . . . . . . .20 - 300 psig (1,4 - 21 bar) Reduced Pressure Ranges (7) . . . . .3-1/2-inches wc - 8 psig (9 mbar - 0,55 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360 psig (25 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:399A-6365/6358 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S300

This pilot-operated pressure relief valve offers elastomer boot-style design, These compact size, spring-loaded regulators offer internal relief and relief
reliable performance and easy maintenance. In-line maintenance with top monitoring constructions available for compliance with code requirements.
entry allows for easy removal of trim for inspection and replacement. The diaphragm and valve disc are constructed of Nitrile.

11
Pressure
C/I FF C/I FF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . .S301F/D SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .S200 SERIES


End Connection Size . . . . .3/4 x 3/4, 1 x 1, 1-1/4 x 1-1/4, 1-1/2 x 1-1/2, 2 x 2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-12, 2-inch
Reduced Pressure Range (5) . . . . . . . . . . . . . . . .4 - 125 psig (0,27 bar - 8,6 bar) Reduced Pressure Range (7) . . . . . . . .2-inches wc - 10 psig (5 mbar - 0,69 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:S301 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S200
This compact pilot-operated regulator has a factory-installed Type 6351 pilot The S200 Series are high-capacity, accurate regulators that respond to quick
with pre-piped tubing. It has the capacity for small industrial and commercial load changes and are available with or without internal relief, integral monitor
meter set applications. It is used in fixed-factor applications where high and monitor constructions. First choice for commercial and industrial service
accuracy is required. Both external and internal downstream pressure applications.
registration constructions.

C/I H C/I H DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Y600 TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .Y690 SERIES


End Connection Size . . . . . .3/4 x 3/4, 3/4 x 1, 1 x 1, 1 x 1-1/4, 1-1/4 x 1-1/4-inch End Connection Sizes . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4, 1-inch
Reduced Pressure Ranges (5) . . . . . . . . . . .1-inch wc - 7 psig (2 mbar - 0,5 bar) Reduced Pressure Ranges (7) . . . . . . . . . 1-inch wc - 7 psig (2,5 mbar - 0,5 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:Y600 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:Y690
The Type Y600 is a self-operated, spring-loaded regulator that provides The Type Y690 is a direct operated regulator used for accurate pressure control
economical pressure-reducing control in a variety of residential, commercial on very low-pressure systems. Downstream pressure is sensed through a pilot
and industrial applications. The pressure settings and the pilot tube of the tube, thus no external control line is required.
Type Y600 also creates a dynamic boost that helps provide greater capacity.

12
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED
F FARM TAP A INSTRUMENT AIR

A A

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .67 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . .1301F/G SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14-inch
Reduced Pressure Ranges (4) . . . . . . . . . . . . . . . . . . .3 - 100 psig (0,21 - 6,9 bar) Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . . . .10 - 225 psig (0,69 - 16 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 psig (17,2 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6,000 psig (414 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Stainless Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass or Stainless Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:67 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:1301
This compact, easy-to-maintain regulator has an optional handwheel for easy These direct-operated regulators are used for applications requiring reduction
adjustment of set point. The 67 Series offers accurate and reliable regulation of high-pressures for small capacity flow and feature a durable stainless steel
with high stability. A token capacity internal relief valve provides overpressure diaphragm. They can be installed in any positon.
protection. Applications include use on airsets in instrument systems.

A A

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .64 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1367


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .12-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4-inch
Reduced Pressure Ranges (7) . . . . . . . . . . . . . . . . . . .3 - 150 psig (0,2 - 10,3 bar) Outlet Pressure Range . . . . . . . . . . . . . . . . . . . . . . . . . . .5 - 35psig (0,34 - 2,4 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .250 psig (17,2 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2,000 psig (138 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Relief Valve
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:64 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:1367
Spring-loaded, self-operated regulators for constant reduced pressure. Body The Type 1367 is a high-pressure instrument supply system designed for
side connection for plugged or unplugged control pressure registration or tap regulation and overpressure protection in one complete package. The system
for a pressure gauge. The Type 64R comes with internal relief. provides installation flexibility and is capable of continuous moisture removal.

13
Slam Shuts/ Reliefs
D C/I FF S DF C/I FF S DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .299SO TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .S208/S209


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1-1/4, 1-1/2, 2-inch End Connection Size . . . . . . . . . .1-1/4 x 1-1/4, 1-1/2 x 1-1/2, 1-1/2 x 2, 2 x 2-inch
Reduced Pressure Ranges . . . . . . . .3-1/2-inches wc - 35 psig (9 mbar - 2,4 bar) Reduced Pressure Ranges (13) . . . .3-1/2 inches wc - 5 psig (9 mbar - 0,34 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10, 3 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .125 psig (8,6 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot with Slam Shut Option Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct with Slam Shut Option
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Ductile Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Ductile Iron
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.2:299 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:S208

A new product from Fisher, the Type 299SO has a wide variety of applications The quick reacting Types S208 and S209 pressure reducing regulators with the
for distribution of natural gas, fuel gas and air. The regulator is the same as the Type VSX shutoff module are typically used in an industrial or commercial
Type 299 Series with the addition of VSX Slam-Shut technology. installation to minimize the shock effect of sudden downstream load changes.
The Type 299 is not an adaptation of existing regulators; instead, it has a new
design of integrated cases and internal registration ports.

C/I R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .252 FILTER TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . .289 SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .14, 34, 1, 2-inch
Maximum Working Pressure (Aluminum) . . . . . . . . . . . . . . 2,120 psig (148 bar) Relief Set Pressure Ranges (13) . . . . . . 3-inches wc -75psig (7,5 mbar - 5,2 bar)
Maximum Working Pressure (Stainless Steel) . . . . . . . . . . . .2,750 psig (190 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .100 psig (6,9 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Filter Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Stainless Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Aluminum or Cast Iron
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .90.1:252 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:289
Designed for high or low pressure pilot supply and general filtering This relief valve provides smooth throttling action to minimize pressure surges
applications, the Type 252 Filter is engineered to provide filtration through the during emergency operation. Its small size allows for easy installation in limited
filter and where the filter cartridge is supported. Standard construction spaces, and high flow rates can be achieved with minimum pressure buildup.
includes 316 SST, making the Type 252 Filter resistant to sour gas and
compliant with NACE as standard.

14
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED
F FARM TAP A INSTRUMENT AIR

R R

TYPE NUMBER . . . . . . . . . . . . . . . . . . .289P-6358 OR 289P-6365 TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1805 SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34, 1, 1-12, 2-inch
Relief Set Pressure Ranges (3) . . . . . . . . . . . . . . . . .0.5 - 100 psig (0,03 - 6,9 bar) Relief Pressure Ranges (3) . . . . . . . . . . . . . . . . . . . . . .5 - 125 psig (0,34 - 8,6 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 psig (7,6 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Aluminum or Cast Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:289P-6358 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1805
This pilot-operated valve offers accurate flow and pressure regulation when Used in farm tap applications, this economical relief valve is needed between
coupled with a high gain pilot. High flow rates are achieved with only a small first- and second-stage regulators. It allows for tight shutoff, easy
increase in buildup pressure. maintenance, simple adjustment and complete venting.

R R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1805P-6358 TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .1808 SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2-inch
Reduced Pressure Ranges (3) . . . . . . . . . . . . . . . . . .10 - 100 psig (0,69 - 6,9 bar) Relief Set Pressure Range . . . . . . . . . . . . . . . . . . . . . . . 5 - 125 psig (0,3 - 8,6 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .110 psig (7,6 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .150 psig (10,3 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron or Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1805P-6358 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:1808
This throttle valve gives accurate, low-cost relief and consists of a Type 1805P An economical, compact design relief valve, the Type 1808 is offered with
main valve and a Type 167AFR pilot. The relief pressure settings are adjusted either a Type 6358 or Type 6365 pilot and is available in either a globe style or
by rotating the pilot spring adjustment screw. angle style. Upstream control line construction is available to provide wide-
open relief flow capacity.

15
Relief
R R DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . .H100-H200 SERIES TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .63EG SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1/4, 34, 1-inch End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6, 8 x 6, 12 x 6-inch
Fixed Relief Set Pressures (16) . . . . . . . . . . . . . . . . . . .25 - 350 psig (1,7 - 24 bar) Relief Set Pressure Ranges (5) . . . . . . . . . . . . . . . . . . .10-300 psig (0,69 - 21 bar)
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .420 psig (29 bar) Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .360 psig (25 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Brass Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron, Steel or Stainless Steel
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:H120, 71.4:H200 Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:63EG

This direct-operated pop relief valve comes with preset and pinned spring This pilot-operated throttling pressure relief valve offers high capacity flow
retainers. Simply operated with wide spring selection, it is used mainly on capabilities. Available with the Type 6365 and 6358 pilots.
pneumatic control lines of air drills, jackhammers and other similar
equipment.

R R

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . .66R & 66RR


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2, 3, 4-inch
Relief Set Pressure Ranges (6) . . . . . . . . . .2-inch wc - 3psig (5 mbar - 0,21 bar)
TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .414
End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 2, 3, 4, 6-inch
Maximum Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 psig (0,69 bar)
Relief Set Pressure Ranges (3) . . . . . . . . . . . . . . .100 - 1,200 psig (6,9 - 82,7 bar)
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Maximum Allowable Pressure . . . . . . . . . . . . . . . . . . . . . . . .1440 psig (99,3 bar)
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . .Cast Iron, Steel or Stainless Steel
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.1:66R
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel
The 66R and 66RR are low-pressure, high-capacity throttling relief valves for Fisher Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.4:414-6305
overpressure protection or inlet back pressure control. Higher set pressure ranges
This pilot-operated backpressure regulator or relief valve provides high-
are available with optional springs, diaphragm plates and other internal parts.
pressure capability for both liquids and gases. The construction is suitable
where pressures on the valve outlet will be essentially atmospheric.

16
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED

Pressure/Francel F FARM TAP A INSTRUMENT AIR

D S DF C/I H S

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ASOFLEX TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .B SERIES


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25, 50, 80,100, 150 End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .3/4 x 1-1/4-inch
Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10 mbar-16 bar Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9 mbar - 4 bar
Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 - 25 bar Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,1 - 5 bar
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Zinc Aluminum
Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NT ASOFLEX 9704 Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA B 9604
ASOFLEX is a silent pilot pressure regulator with built-in slam shut shut-off Spring loaded two-stage domestic regulator design maintains constant outlet
valve. Silent operation range is <75/80dBA. pressure. Used in residential, commercial or industrial applications.

D S DF F S

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .CMAX TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DRPN


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25, 80, 150 End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .DN 25
Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 4 bar Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .2 - 4 bar
Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,7 - 25 bar Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .up to 25 bar
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB
Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA C MAX 9607 Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . NTA DRPN 9604
CMAX is a medium range pilot operated regulator with slam shut shut-off DRPN is a direct operated pressure regulator for natural gas distribution
capability suitable for natural gas distribution networks and commercial networks and transmission applications. Incorporates slam shut shut-off
applications such as boiler room natural gas pressure regulation. technology.

17
Pressure/Francel
T C/I S DF D S DF

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .OSE TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .MPS


End Connection Size . . . . . . . . . . . . . . .1, 2, 3, 4, 6-inch (DN 25, 50, 80, 100, 150) End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . DN 25, 50, 80,100
Release Point Range . . . . . . . . . . . . . 4-inch wc - 1,044 psig (0,10 mbar - 72 bar) Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,3 - 60 bar
Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1,450 psig (100 bar) Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .7 - 70 bar
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Pilot
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .A216WCB
Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .71.6:OSE Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA MPSE 9604
The OSE Slam Shut valve is used to protect transmission and distribution The MPS is a low-noise pilot operated gas pressure regulator for natural gas
networks and gas mains in the industrial sector. Slam shut features internal transport lines. Its design is suitable for compact installations. Diaphragm is
bypass for simple manual startup. only moving part.

C/I H C/I H S

TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .ROD AGNI TYPE NUMBER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .REGAL 2


End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Meter End Connection Size . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .1, 1-1/4 x 1-1/4-inch
Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(Connection) 19 - 39 mbar Outlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .8 mbar - 0,34 bar
Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,5 bar Inlet Pressure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .0,5 - 10 bar
Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Limit Flow Valve Operation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Direct
Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel Body Material . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .Steel
Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .(M) ROD 0 12 Bulletin Number . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .NTA REG2 9605
ROD AGNI is natural gas solution for residential service. ROD AGNI replaces REGAL 2 is a direct operated, spring loaded regulator with a built-in slam shut
the combination of a gas meter and regulator for customers with limited gas shut-off valve. Typically used in natural gas supply applications in apartments,
flow requirements. After a predetermined flow rate is passed, the regulator commercial and municipal buildings.
shuts off gas flow automatically. The regulator can be reset manually.

18
T TRANSMISSION C/I COMMERCIAL/INDUSTRIAL R RELIEF VALVE
C CITY GATE FF FIXED FACTOR/PFM S SLAM SHUT
D DISTRICT GATE H RESIDENTIAL SERVICE DF DIN FLANGED

Pressure/Francel F FARM TAP A INSTRUMENT AIR

T D

TRANSMISSION STATIONS DISTRIBUTION STATIONS


Fisher and Francel regulators, gas metering and pressure reducing stations are Francel distribution stations feature silent pressure regulators and slam shut
specified and used in natural gas transmission lines throughout the world. technology. Francel manufactures and assembles complete Offtake Stations
Our engineers design transmission skids to meet customer specifications with or District Regulating Stations to customer specifications. These stations are
complete gas control systems including pressure regulation, filtration, gas shipped as skids ready for installation. A typical District Regulating Station is
heating, odorization and monitoring. A typical double line Offtake Station is capable of reducing pressure from 19 bar to 4 bar at a flow of 2,000 SCMH.
capable of reducing 70 bar pressure to 4 bar at a flow rate of 1,500 SCMH.

D C/I H T D C C/I H

CABINETS / MODULES SERVICE PITS


Francel designs and manufactures a wide range of fitted, painted metal Domestic or commercial end users may require compact regulator service
cabinets and modules in various sizes. Cabinets typically enclose regulators pits or vaults to contain and protect natural gas service assemblies consisting
and related pressure reducing components. Cabinets and modules may be of regulator, vent, and piping. Service pits are buried underground but are
specified for aesthetic, environmental, or security reasons. accessible for necessary utility maintenance.

19
Fisher-Francel Natural Gas Regulator Selection Table
Transmission
City Gate
Typical Applications
District Gate
* Reduced Pressure Ranges, Relief Set Points and
Farm Tap
Maximum Inlet Pressures are expressed in psig/bar
Commercial/Industrial or water column (wc) and millibar (m).
Fixed Factor
Residential Service ** Please request our free literature CD-ROM to view
full details of products. See page 5 of this brochure
Instrument Air
for ordering information.
Relief Valve
Slam Shut

Reduced Pressure Ranges Fisher/Francel End Connection Sizes Maximum Further Reference
and Relief Set-Points* Type or Series Inlet
Number within ( ) indicates Pressure* Page Product
spring ranges. No. Bulletin**
(8) 3-1/2"wc-35 / 9(m)-2,4 299 1-1/2", 2" 150 / 10,3 8 71.2:299
(10) 2"wc-300 / 5(m)-20,7 1098-EGR 7 sizes from 1" to 12"x6" 400 / 27,6 8 71.2:1098-EGR
(9) 2"wc-100 / 5(m)-6,9 99 2" 1,000 / 69 8 71.2:99
(8) 5"wc-700 / 0,34-48,3 399A-161EB/161Y 16 sizes from 1" to 12"x6" 1,050 / 72,4 8 71.2:399A-161
(6) 5-500 / 0,34-34,5 627 3/4", 1", 2" 2,000 / 138 9 71.1:627
5-100 / 0,34-6,9 627F 3/4", 1", 2" 100 / 6,9 9 71.1:627F
(3) 10-600 / 0,69-41,4 310A-32A 1", 2", 3", 4"x6" 1,480 / 102 9 71.2:310A
(10) 3-500 / 0,21-34,5 630 1", 2" 1,500 / 103 9 71.1:630
(9) 2"wc-10 / 5(m)-0,69 133 2" 60 / 4,1 10 71.1:133
(7) 2-60 / 0,14-4,1 133HP 2" 150 / 10,3 10 71.1:133
(6) 4"wc-5 / 10(m)-0,34 66 2", 3", 4" 25/ 1,7 10 71.1:66
(6) 4-1/2"wc-2.5 / 11(m)-0,17 S402 3/4"x3/4", 3/4"x1", 1"x1" 125 / 8,6 10 71.1:S402
(5) 3-1/2"wc-2.5 / 9(m)-0,17 S102C 3/4", 1", 1-1/4", 1-1/2" 150 / 10,3 11 71.1:S100C
(6) 3-1/2"wc-2.5 / 9(m)-0,17 S252/S254 3/4", 1" 125 /8,6 11 71.1:S250
(5) 20-300 / 1,4-20,7 399A-6365/6358 16 sizes from 1 to 12"x6" 360 / 25 11 71.1:399A-6365
(7) 3-1/2"wc-8 / 9(m)-0,55 S300 1-1/4", 1-1/2", 2" 150 / 10,3 11 71.1:S300
(5) 2-20 / 0,14-1,4 S301F/D 3/4", 1", 1-1/4", 1-1/2", 2" 125 / 8,6 12 71.2:S301
(7) 2"wc-10 / 5(m)-0,69 S200 1-1/2", 2" 150 / 10,3 12 71.1:S200
(5) 1"wc-7 / 2(m)-0,5 Y600 5 sizes from 3/4"x3/4" to 1-1/4"x1-1/4" 150 / 10,3 12 71.1:Y600
(7) 1"wc-7 / 2(m)-0,5 Y690 3/4", 1" 150 / 10,3 12 71.1:Y690
(4) 3-100 / 0,21-6,9 67 1/4" 250 / 17,2 13 71.1:67
(3) 10-500 / 0,69-34,5 1301F/G 1/4" 6,000 / 414 13 71.1:1301
(7) 3-200 / 0,21-13,8 64 1/2" 250 / 17,2 13 71.1:64
5-35 / 0,34-2,4 1367 1/4" 2,000 / 138 13 71.1:1367
(8) 3-1/2"wc-5 / 9(m)-0,34 299SO 1-1/4", 1-1/2", 2" 150 / 10,3 14 71.2:299
(13) 3-1/2"wc-5 / 9(m)-0,34 S208/209 4 sizes from 1-1/4"x1-1/4" to 2"x2" 125 / 8,6 14 71.1:S208
(13) 3"wc-75 / 7(m)-5,17 289 1/4", 3/4", 1", 2" 100 / 6,9 14 71.4:289
10-100 / 0,69-6,9 289P-6358 or 6365 1", 2" 110 / 7,6 15 71.4:289P-6358
(3) 5-125 / 0,34-8,6 1805 3/4", 1", 1-1/2", 2" 150 / 10,3 15 71.4:1805
(3) 10-100 / 0,69-6,9 1805P-6358 2" 110 / 7,6 15 71.4:1805P-6358
5-125 / 0,34-8,6 1808 2" 150 / 10,3 15 71.4:1808
(16) 25-300 / 1,7-24 H100-H200 1/4", 3/4", 1" 420 / 29 16 71.4:H120 / H200
(5) 3-300 / 0,69-20,7 63EG 7 sizes from 1" to 12" x 6" 360 / 25 16 71.4:63EG
(6) 2"wc-3 / 5(m)-0,21 66R & 66RR 2", 3", 4" 10 / 0,69 16 71.1:66R
(3) 100-1,200 / 6,9-82,7 414 1", 2", 3", 4", 6" 1,440 / 99 16 71.4:414-6305
10(m)-16 bar ASOFLEX DN 25, 50, 80, 100,150 0,7-25 bar 17 NT ASOFLEX 9704
9(m)-4 bar B SERIES 3/4" x 1-1/4" 0,1-5 bar 17 NTA B 9604
2-4 bar CMAX DN 25, 80,150 0,7-25 bar 17 NTA C MAX 9607
2-4 bar DRPN DN 25 up to 25 bar 17 NTA DRPN 9604
(11) 0.3-1,045 / 0,02-72 OSE 1", 2", 3", 4", 6" 1,450 / 100 18 71.6:OSE
0,3-60 MPS DN 25, 50, 80 100 7-70 bar 18 NTA MPSE 9604
19 (m)-39 (m) bar ROD AGNI meter 0,5 bar 18 (M) ROD 0 12
8 (m)- 0,34 bar REGAL 2 1", 1-1/4" x 1-1/4" 0,5-10 bar 18 NTA REG2 9605

20
Relief Valves Regulators

Remote Operations Controller


Remote Drive ROC

Service Fisher Solutions Delivery

Sales Support Training


ISO 9001
D350358X012 Fisher Controls International, Inc. All rights reserved.