MODEL
MJ-E26CX-H
INSTRUCTION MANUAL
E
English
Operating
Tips on Drying Laundry 11
When you want to perform automatic
operation 12
EASY DEHUMIDIFYING (AUTO) INTELLIGENT LAUNDRY
When you want to perform manual
operation 13
AUTO 13 HIGH LOW LOW TEMP 14
Using Child Lock 14
Reducing Growth of Mildew in Bathroom
(Bathroom Mildew Guard) 15
Using Louvre 16
Using Timer 17
Removing Odor from Clothes
(Clothes Deodorant) 18
Drying Inside Operation 19
Draining 20
Continuous Drainage 21
Troubleshooting
In order to ensure correct usage, please read this
instruction manual carefully and retain it for future Maintenance 22
reference. Replacement Parts 23
Before accepting the Warranty at the time of purchase,
Storage and Disposal 23
please make sure that the date of purchase, place of
purchase and other items are correctly lled in the form. Troubleshooting 24
Keep the Instruction Manual and Warranty in a safe Specifications 26
place.
INTELLIGENT LAUNDRY P. 12
When you want to perform continuous operation
Tips on Drying Laundry
HIGH P. 14 P.11
EASY DEHUMIDIFYING P. 12
When you want to perform continuous operation
HIGH P. 14
Reducing blowing sound and performing continuous operation
LOW P. 14
BATHROOM MILDEW
GUARD
P.15
DEO-DRY P.18
E
How does the dehumidifier work?
If you pour cold water into a cup, the air around it z The defrosting operation is
becomes cold, causing water droplets to form on the performed when the room
surface of the cup. temperature falls to 15C or less.
The dehumidier takes advantage of this phenomenon In all modes, the defrosting operation is performed
to remove moisture from the air. automatically when the room temperature falls to 15C or less.
Approximately once every 40 minutes at its most frequent,
1 The unit draws air from the room, cools it with its indicates and airow (dehumidifying) stops automatically,
25
5
they diffe
are r
<Cause>
en
y
0 5 10 15 20 25 30
Wh
t?
WARNING
Do not damage or modify the power Do not attempt to repair,
cord or plug. Do not use power sockets disassemble, or modify the unit.
in which the plug fits loosely.
Do not modify, bundle, twist, bend or heat the
power cord. Do not place under objects or
use with the end close to the plug bent.
(Keep pets from biting the cord.)
Do not put your fingers Continuing to operate the unit may result in
or any long object, into fire, electric shock, or malfunctions.
the air intake/outlet. Contact your dealer or Mitsubishi Electric Service
Do not touch the swing Centre for consultation.
louvre.
Remove water that has collected in
The internal fan rotates at high speeds, the tank.
and such actions may result in injury or
malfunctions. Accidentally drinking the water or using it for
other purposes may cause illness and/or
unforeseen accidents.
E
electric shock and/or fire by short-
circuiting. Be especially careful when
using the unit where there
Do not use the unit in a is someone who is unable to adjust the
bathroom or other humidity (infant, child, or elderly person).
location where it is If air-ow is directed at the body for long
likely to come into periods, it may harm ones physical condition
contact with water, or wash it with and lead to dehydration.
water.
Exposure to water may result in fire or electric Do not stand on, sit on or lean
Warning The silver ion lter is supplied with the unit at the
time of purchase. Set before using the unit. P10
E
Pre-filter P22
Downward louvre P16
Installing your
dehumidifier
Make sure to leave some
At least 50 cm
space around the unit.
At least 20 cm
At least 20 cm
At least
<Operating noise>
20 cm
Use the unit on a mat or the
like. This reduces vibration and
noise. It also prevents leaving
depressions on carpets, etc. At least 20 cm
Control Panel
SWING LOUVRE Switch DRYING INSIDE lamp
Sets the swing louvre direction or Flashes during
locks it into position. the drying inside
operation.
P16
Lights when the drying
Tank FULL lamp inside operation is
Lights when the tank is full waiting to begin.
of water. DRYING INSIDE switch
Lights when the tank is not Use this to switch the
attached to the unit. internal drying operation
ON and OFF.
P20
P19
POWER lamp
Lamps ON/OFF TIMER Switch Lights during operation.
The lamp for the Sets the time of the timer. POWER switch
selected mode lights. P17 Turns the power ON/OFF.
SELECTION Switch MODE Switch
Switches the operating P12
Switches between
mode. DEO-DRY lamp
EASY DEHUMIDIFYING
HUMIDITY SELECTION Lights during deodorizing clothes operation.
operating mode
Switch DEO-DRY Switch
and INTELLIGENT
Sets the humidity. Switches to deodorizing clothes operation.
LAUNDRY operating
mode. P13~15 P18
P12~13
CHILD LOCK
To set the child
lock, press the
mode button for
three seconds.
P14
HIGH
LOW
EASY DEHUMIDIFYING
BATHROOM MILDEW
INTELLIGENT DEO-DRY
GUARD
LAUNDRY
LOW TEMP
AUTO
You can select one of the above eight operating modes. It is not possible to use a
combination of two operating modes.
Operating Mode
Indicator
E
Indicates the selected
operating mode.
P13~15
Information Display
Indicates the dehumidier and room conditions.
Low Temperature Defrost Indicator High Humidity Warning
Indicator
If the room temperature drops When is indicated, blowing If the humidity in the room rises to
to approximately 15C or (dehumidifying) is stopped and the 75% or higher when the unit is OFF,
lower during operation, is frost that has accumulated inside ashes to notify you.
indicated to notify you. melts and drops into the tank . Please Dehumidifying is recommended
Activating LOW TEMP mode wait a while as operation will resume when is ashing.
is recommended when is in around 5 minutes.
indicated. P14 In DEFROST mode, blowing
(dehumidifying) and the louvre are
stopped and the sound coming
from the unit changes.
Defrosting starts automatically when the
room temperature drops to 15C or lower.
(This may be as often as once every For not using the high humidity warning,
approximately 40 minutes.) remove the power plug.
Tank
Make sure the tank is not broken or cracked
With the strips facing up, set the silver ion The current humidity
filter inside the tabs on the pre-filter. is indicated.
Strips
If the louvre is open, it closes automatically.
Tabs (4)
Carrying the Unit
The unit can be transported using the wheels on the bottom.
Check that the water tank is empty and the louvre
is shut before transporting.
4 Set the pre-filter.
Raise handle to transport
Insert the bottom
tabs into the unit The unit may become difcult
until they click.
to move depending on the
direction of the casters. Using
excessive force to move the unit
may cause the unit to fall over.
Do not hold the louvre when
moving the unit.
Do not attempt to carry the unit horizontally.
Make sure the silver ion lter is attached to the unit. Tilting the unit will result in the water spilling and
Note
If it is not, ne dust will enter inside the unit and cause a malfunction.
cause a malfunction. Use the wheels on hard at surface.
Note
10
E
easily come into contact with them.
Clothes placed close together will take time to dry.
Use the swing louvre to blow air onto all of the clothes P16
Clothes places in locations that are not exposed to the wind will
take time to dry.
When there are a lot of clothes
Change the hanging positions of the clothes during drying to
ensure air is blown onto all of the clothes.
About the Room for Hanging Clothes
Using the unit to dry clothes hung in a room is recommended on days such as
the following.
z Cloudy and rainy days z Days with a lot of pollen z Days you are unable
and dust in the air to bring in the washing
during daylight hours
Drying clothes hung outside takes Hanging clothes inside enables Dry clothes absorb dampness
a while on days with high humidity you to prevent pollen and dirt when the air cools outside after the
because it is difcult for water to getting on them. sun sets, meaning your efforts will
evaporate. have gone to waste.
11
2 1
Information
compressor.) Dehumidifying begins approximately
The POWER lamp lights. 3 minutes after you press the POWER switch.
The current humidity is displayed. When dehumidifying begins, the operational noise
The louvre opens and airflow starts. increases.
The unit remembers the operating mode. Even if the
plug is disconnected or the power turned off, the unit
restarts at the previous setting.
12
AUTO When you want to set the humidity and perform dehumidifying
E
2 1
1 Press P12
Operating
Guide on after you turn the power ON, regardless of the humidity
Up to approx. Up to approx. of the room.
Usage 2
17 m 6kg The humidity may not become lower when the door
Information
Keep usage within the ranges of the room is opened and closed frequently or
depending on the size and conditions of the room.
specied in Rough Guide on Usage
to ensure efcient drying. <Checking the set humidity and setting the humidity>
Press the
Press
switch again.
Drain the tank before use. Press the switch once Pressing the
The unit may stop before the laundry to display SELECTION switch again while
dries because of a full tank.
and then the current SELECTION is
humidity setting. displayed allows you to
If this is used in conjunction with the set the humidity setting.
off timer, operation may stop before
Information
13
1 Press P12 If you lock the unit when the POWER is OFF.
The unit will not turn on, even if you press the
POWER button to turn it on. Only the CHILD
LOCK lamp will blink.
2 Press to select the
(Pressing the POWER button again will
operating mode cause the lamp to turn on solidly.)
Changes with every If you lock the unit when the POWER is ON.
press. The unit will not turn off, even if you press the
POWER button to turn it off. Only the CHILD
A border is
LOCK lamp will blink.
displayed around
(Pressing the POWER button again will
the selected
cause the lamp to turn on solidly.)
operating mode.
Only the CHILD LOCK switch can be operated while
Information
14
Preparation
Install the unit in the dressing room (entrance to
dressing room
the bathroom). Adjust the downward blowing louvre as desired.
(Do not install the unit inside the bathroom.) P16
E
Adjust the orientation of
the unit so that air ows
toward the whole room.
2 Press to select
BATHROOM MILDEW GUARD
Changes with every
press.
If water remains in the
bathtub, cover the bathtub. A border is
displayed around
the selected
operating mode.
Start operation
CAUTION
(Air is blown from the downward air outlet.)
Do not use the unit in a bathroom or other location where it is Operation stops
likely to come into contact with water, or wash it with water. after approximately 4 to 12 hours.
The unit does not have a drip-proof or water-proof
structure. Water coming into contact with the unit may The POWER lamp goes out and the
result in a re due to a short circuit, or an electric shock. operating mode indication disappears.
Rough Guide on Usage Air is blown from the downward air outlet
Location to be dehumidied Size automatically to dry the oor surface. When you
want to dry the walls and ceiling, change the
Bathroom (bathroom + Up to approximately 7m2 (size of direction of the swing louvre. P16
dressing room) bathroom + dressing room)
When you want to use other than the downward air
Room Up to 21m2 outlet, adjust the orientation of the unit.
For more effective operation, use the unit within the above ranges. The airow rate cannot be set because it is
changed automatically. It is also not possible to use
Operating
For effective use, keep the windows and doors of the room
closed and do not ventilate the room during operation. this in conjunction with another operating mode or
Operation may not be sufciently effective if the to set the humidity.
bathroom is spacious or because of the building
materials used for the oor and walls of the bathroom. <When you want to abort the operation>
Drops of water may remain in places where water collects easily.
Information
Mildew may grow depending on the room conditions When you want to end the operation
and the type of mildew. partway through:
Example: Where air circulation is poor such as beneath
a container or the like in the bathroom or at the back of Press the POWER switch (OFF).
a cupboard or behind furniture in the bathroom. When you want to switch to another
This operation cannot dry locations where the airow cannot
reach such as inside a bathtub and beneath a container. operation:
This operation cannot remove existing mildew and Press the MODE switch or SELECTION
water scale, or slime in the drain outlet.
If this operation is used in conjunction with the off switch.
timer, operation may stop before drying is complete.
Changes
Stop swing
with each
press the
swing
direction. Wide
During
operation,
Press to select the Upward
operating mode
The swing monitor indicates the range in Downward
which the louvre swings. (The movement of
the louvre and monitor do not match.)
Rear
To stop the Stop swing The louvre stops and the swing monitor disappears.
louvre at the Wait until the louvre stops and then adjust the angle by
desired angle hand.
Wide swing
The louvre swings so that air is blown over a wide area.
To cover the
The blowing range is approximately 135. (The moving range
entire room of the louvre is approximately 120)
Rear swing The louvre will swing so as to blow air toward the backside of
To dehumidify the unit.
The blowing range is approximately 60.
closets Depending on the angle of the louvre, some air may also blow out
from the downward outlet.
The swing operation stops when the power cord is unplugged.
Information
The level of noise emitted from the unit varies according to the angle of the air-ow.
The louvre may stop for up to about 8 seconds to adjust its position, but will start moving again afterwards.
If the louvre is knocked out of the desired angle because the louvre is touched by a hand or object, press the SWING
LOUVRE switch again to readjust the position.
If air is blown directly onto a wall, the wall may become dirty because of dust in the air being blown onto the wall.
When you want to dry training shoes, place them at a position that is a little higher than the oor.
16
E
2 1 2 3 1
Operating
is reduced by 1 as each hour elapses. notify if you forget to press the switch.
When the set time elapses, operation (The alarm (pipi...) sounds for one minute.)
stops and the louvre closes automatically.
The POWER lamp goes out and the <Display example>
operating mode indication disappears. Humidity setting
(set to 60%)
When the drying inside operation (AUTO) is set, Swing WIDE
the drying inside operation is performed. P19 On timer is set
to 5 hours
Preparation
How to Hang Clothes Hang the hangers on which the
clothes are hung, and then place
Secure hangers so they will Space out
not be moved by airow. laundry to the dehumidifier beneath them.
improve airow.
1 Press P12
2 Press
The DEO-DRY lamp lights.
Drain the water tank before operating. The POWER lamp and DEO-DRY lamp
Ensure ventilation during operation.
go out.
The odor cannot be removed in the following cases.
When the temperature and humidity inside the <When you want to abort the operation>
room are low Pressing the DEO-DRY switch does not abort
When there are many clothes the operation.
The odor will not be removed from parts not blown by (The deodorant dry operation starts again.)
Information
the wind.
The sharp odor such as perfumes and chemicals When you want to end the operation
cannot be removed. partway through:
The odor of oil and dirt on clothes cannot be removed. Press the POWER switch (OFF).
If the operation has little effect, try the operation
again, or wash or clean the clothes.
When you want to switch to another
The humidity in the room may rise as a result of the operation:
discharging of moisture that builds up inside the unit. Press the MODE switch or SELECTION switch
Discharged moisture may appear white depending to change to the dehumidifying operation.
on the temperature and humidity in the room.
<Details on Clothes Deodorant Operation> This operation takes approximately one hour.
CLOTHES DEODORANT switch (ON)
18
Press while
E
the power is ON. Press while
the power is
Drying inside operation standby OFF.
(The DRYING INSIDE lamp lights)
The drying inside operation starts
The DRYING INSIDE lamp ashes and
the current humidity indicator turns off
The operation ends the louvre stops in the vertical position
The drying inside operation starts
Drying inside operation
The DRYING INSIDE lamp ashes, the
current humidity indicator turns off, and The drying inside operation ends
the louvre stops in the vertical position The DRYING INSIDE lamp turns off and
the louvre closes
Drying inside operation
The drying inside operation ends
The DRYING INSIDE lamp turns off and <When you want to abort the drying inside
the louvre closes operation>
When you want to end the operation
<When you want to deactivate automatic partway through:
operation> Press the DRYING INSIDE switch.
Press the DRYING INSIDE switch (The DRYING INSIDE lamp turns off)
while the unit is ON When you want to switch to another
(The DRYING INSIDE lamp goes out) operation:
Press the POWER switch.
Operating
Connecting/disconnecting the power plug deactivates automatic operation.
This function does not remove existing mildew. Also, aborting drying inside operation may cause the benets to diminish.
Information
Do not close the louvres while drying inside operation as this causes noise.
The moisture expelled from inside the unit may cause the humidity level of the room to rise.
The air leaving the unit may appear white depending on the humidity or temperature of the room.
The moisture expelled from inside the unit may smell due to odorants* that were not caught by the lter dissolving in the water.
* The silver ion lter is mainly for absorbing ammonia.
The OFF timer cannot be set during drying inside operation.
<Details on drying inside operation> This operation takes approximately one hour. However, when
the room temperature is below 1C, drying time is shored to
protect the compressor.
OFF
19
Information
unit will automatically return to operation
mode.
Tank full lamp lights. When the Tank full lamp is lit, no operation
(The unit beeps continuously). but ON/OFF is possible.
Blowing stops (louvre stops). When using the OFF timer, you are only
The operation indicator lamp turns off. notied by the FULL lamp lighting.
1 Remove the water tank. 3 Slide the tank lid to close the
tank.
20
E
installed installed hose raised to a level
higher than the drainage When draining water continuously or left
outlet unattended for long periods, inspect the
The water will not unit once a fortnight.
drain. Foreign objects, etc. could clog the hose resulting in
overheating and/or leakage.
Operating
221mm
Hose
114mm
Use pincers to cut away the three securing 3 Check for water
ribs of the continuous drainage outlet. Remove leakage.
carefully without letting any debris fall inside.
Push here
Conrm that the hose does not show signs of deterioration such as bending cracks and clogging.
Note
Inspect the hose every 2 weeks. Insects or dirt blocking the hose may cause leakage resulting in malfunctions.
21
Maintenance powders, chemically treated dusters, gasoline, benzene, thinners or other solvents,
as they can damage the unit or the water tank, which may result in leakage.
Once Every Two Weeks Do not use detergent or hot water. Also, do
not use a brush or the like to scrub the filter
Pre-lter and sensor part or rub the filter while soaking. This may
damage the filter.
Clogging with dust and the like reduces the Any yellow or dark stains may remain on the
effectiveness of dehumidifying. Clean about once lter, but should not affect performance.
every two weeks.
How to remove and attach P10 The lter can be soaked for a total of eight
times. After that, replace with a new lter.
You have soaked the filter 8 times. Performing internal drying to prevent mildew
The silver ion filter has turned brown due to growth is recommended.
E
cigarette smoke or black with dust. Hang the power
2 cord on the
Filter life differs on usage and environmental
conditions cord hook.
Remove the pre-filter from the unit,
and replace the silver ion filter. Drain out the
Removing and setting the filter, see P10
3 water. P20
Unit
Do not disassemble. Dispose according to the
garbage regulations in your district.
23
The unit does not operate (No Check to see if anything is blocking the air intake or outlet.
Remove the obstruction. P5
air comes out and the louvre
Is operation being performed with the unit set to EASY DEHUMIDIFYING
does not swing) or AUTO?
The unit is automatically switching dehumidifying, blowing, and stopping. P12~13
The unit stops Is operation being performed with the unit set to Bathroom Mildew Guard?
Operation stops automatically if the humidity falls. Operation stops
after a minimum of 4 hours. P15
Check to see if the pre-lter is clogged.
Clean according to the maintenance procedures. P22
Is operation being performed with the unit set to INTELLIGENT LAUNDRY?
If the room temperature is approximately 5C or less, operation stops after
Stops after approximately 1 hour. If the room temperature is low, it becomes difcult for
P12~13
a short time water to evaporate from clothes because the humidity does not change.
Is operation being performed with the unit set to DEO-DRY?
This operation is designed to end after approximately 1 hour.
P18
Check to see if the water tank is full.
P20
Empty the water tank and return it to its original position.
Lights Check to see if the water tank is inserted properly.
Adjust the position of the water tank.
P10
Check to see if the unit is in defrosting mode. The unit activates
defrosting mode when the room temperature drops below 15C. The
dehumidier and blower functions stop during defrosting. P3
Indicates Is operation being performed with the unit set to DEO-DRY?
is displayed during compressor operation.
P18
The unit continues to operate Is the unit set to drying inside mode?
even though it is turned off This function activates automatically after ending operations. P19
The water tank contains liquid The residue is from nal product testing at the factory. It is not a result of a
or white water residue malfunction.
24
E
The operating
sound suddenly The sound increases when the compressor activates (approximately 3 minutes
The unit increases in after turning on the unit or during EASY DEHUMIDIFYING or AUTO).
makes volume
noises The wind sound The volume of the sound differs depending on the angle of the louvre. P16
changes in volume
The unit produces This is the sound of the refrigerant. The sound can be heard while the refrigerant
a simmering sound stabilizes after the unit turns on, changes modes, or stops.
The unit produces This is the sound of the compressor. In modes that monitor the humidity
a buzz that sounds level or during drying inside, the compressor operates intermittently
intermittently (or causing the sound to be heard occasionally. The compressor does not
the compressor activate after turning the unit off, or for 3 minutes after plugging the unit
does not activate) into a power socket. (This is to protect the compressor from damage.) P12
When first used The heat converter heats rapidly causing an odour. This is not a malfunction.
CURRENT HUMIDITY
indicator place of purchase.
If the symptoms persist even after following the prescribed remedies, or the error message does not
disappear, unplug the power cord, and contact the place of purchase.
25
The dehumidifying capacity is a value obtained when the dehumidier is continuously run at a room
temperature of 30C and relative humidity of 80%. It indicates the amount of dehumidication per day (24
hours).
Standby power approximately 1.5W.
NOTE
It is impossible to remove the back
panel because the two spots shown
are fastened with two special screws.
If the unit malfunctions, contact your
Mitsubishi dealer.
ZT936Z159H51
26