Table of Contents page

Features Before using the unit


INTELLIGENT LAUNDRY Recommended Ways of Using the Unit 2
DEO-DRY Features of this dehumidifier 3
BATHROOM MILDEW GUARD Precautions 4
DRYING INSIDE Warning 6
Names and Functions of Parts 6
Before using your dehumidifier 10

Operating
Tips on Drying Laundry 11
When you want to perform automatic
operation 12
EASY DEHUMIDIFYING (AUTO) INTELLIGENT LAUNDRY
When you want to perform manual
operation 13
AUTO 13 HIGH LOW LOW TEMP 14
Using Child Lock 14
Reducing Growth of Mildew in Bathroom
(Bathroom Mildew Guard) 15
Using Louvre 16
Using Timer 17
Removing Odor from Clothes
(Clothes Deodorant) 18
Drying Inside Operation 19
Draining 20
Continuous Drainage 21

Troubleshooting
In order to ensure correct usage, please read this
instruction manual carefully and retain it for future Maintenance 22
reference. Replacement Parts 23
Before accepting the Warranty at the time of purchase,
Storage and Disposal 23
please make sure that the date of purchase, place of
purchase and other items are correctly lled in the form. Troubleshooting 24
Keep the Instruction Manual and Warranty in a safe Specifications 26
place.

e_mj_e26cx_h.indb 1 2009/10/26 17:22:18


Recommended Ways of Using the Unit
When you want to dry laundry
When you want to perform automatic operation

INTELLIGENT LAUNDRY P. 12
When you want to perform continuous operation
Tips on Drying Laundry
HIGH P. 14 P.11

When you want to dehumidify


When you want to perform automatic operation

EASY DEHUMIDIFYING P. 12
When you want to perform continuous operation

HIGH P. 14
Reducing blowing sound and performing continuous operation

LOW P. 14

When you are worried about


mildew in the bathroom

BATHROOM MILDEW
GUARD
P.15

When you want to remove


odor from clothes

DEO-DRY P.18

e_mj_e26cx_h.indb 2 2009/10/26 17:22:19


Features of this dehumidier
z Room temperature may rise z The unit can operate in a room
2-4C during operation. temperature range of 1-35C.
The dehumidier does not have a cooler function. Due to However, if the room temperature exceeds 35C, the unit may
heat produced during operation, the room temperature operate in blower mode or increase the airow. This is because
the temperature within the unit rises causing the protection
may rise 2-4C. As a result, the unit may blow warm air, mechanism to operate. In order to lower the internal temperature
but this is not due to a malfunction. (During winter, the of the unit, use the unit with the swing stopped and louvre vertical.
air may not feel warm as the temperature is below body If the temperature is below 1C, the extracted water is close
temperature.) to freezing disabling the dehumidier, and only the blower
is operational.

E
How does the dehumidifier work?
If you pour cold water into a cup, the air around it z The defrosting operation is
becomes cold, causing water droplets to form on the performed when the room
surface of the cup. temperature falls to 15C or less.
The dehumidier takes advantage of this phenomenon In all modes, the defrosting operation is performed
to remove moisture from the air. automatically when the room temperature falls to 15C or less.
Approximately once every 40 minutes at its most frequent,
1 The unit draws air from the room, cools it with its indicates and airow (dehumidifying) stops automatically,

Before using the unit


cooling coil, causing the moisture to transform into and then the frost that has accumulated inside the unit will be
water droplets. melted and dropped into the tank.
Please wait a moment as operation will resume in around 5 minutes.
2 The water droplets fall into the water tank.
3 Dehumidified air is heated by the re-heating coil,
and then blown out. Louvre stops
Blowing (dehumidifying)
The humidity of the room is thus reduced by repeating
stops
steps 1, 2, and 3. The Operation sound changes
Dry (Warm) air

Cooling coil Re-heating coil z The amount of dehumidifying
Moist air
becomes less in winter.
When the temperature and humidity are low, the amount of
water collected is decreased.
In winter, because the temperature is lower than in summer, the effect
Compressor Water tank
of the dehumidier is greatly reduced as shown in the graph below.
Although only a little water collects in the tank, this is not a
malfunction.
Temp. Temp.

z The humidity reading on the unit


may differ from a hygrometer in
the same room. Summer (humidity) Winter (dampness)
Even in the same room, temperature and humidity levels
may differ from place to place. If the hygrometer and the Values obtained when operated with high humidity
unit are in different parts of the room, the humidity levels
Dehumidifying capacity (L/day)

25

are prone to differ. Moreover, humidity levels differ between 20


places that have good and no airow.
15
Use the reading on the unit as an estimate.
10

5
they diffe
are r
<Cause>
en
y

0 5 10 15 20 25 30
Wh

t?

Inconsistencies Room temperature (C)


in temperature
The values shown on the graph were measured
and humidity
at constant temperature and humidity and do not
Difference in
reect values obtained in actual usage conditions.
location
Difference in
When humidity is high as a result of snow or rain even though
hygrometer
the air temperature is low, the amount of dehumidification
precision
increases compared with HIGH mode if you perform operation
in LOW TEMP mode. P14

e_mj_e26cx_h.indb 3 2009/10/26 17:22:19


Precautions
The following diagrams indicate circumstances Meanings of the graphic symbols used in this manual and on
where danger can result from mishandling the unit. the unit are explained below.

WARNING CAUTION Do not Always


Forbidden follow the
disassemble instructions
Mishandling may result in Mishandling may result in
fatal or serious injuries. minor injuries or damage to Do not
Keep away subject to
your home or property, etc. from re water

WARNING
Do not damage or modify the power Do not attempt to repair,
cord or plug. Do not use power sockets disassemble, or modify the unit.
in which the plug fits loosely.
Do not modify, bundle, twist, bend or heat the
power cord. Do not place under objects or
use with the end close to the plug bent.
(Keep pets from biting the cord.)

This may result in fire and/or electric shock.


Refer servicing to your dealer or Mitsubishi Electric
Service Centre.
The cord may be damaged resulting in fire, Exclusively use 220 to 240 V AC
electric shock or heat generation. power sockets for the power supply.
Do not plug many power cords Failing to do so may result in a fire and/or
into one power socket. electric shock.
This may result in fire, electric shock or Use an extension cord by itself.
malfunctions.
Wipe dust off the power plug and
Do not start/stop the unit by insert the plug firmly.
plugging/unplugging the power
cord. If the plug is not fully inserted into the socket,
dust may gather on the connectors which may
This may result in fire and/or electric shock. cause fire and/or electric shock.
Do not put the unit near heat- Should abnormal symptoms occur
generating devices (such as stoves, (a burning smell, etc.), switch off
fan heaters, etc.). the unit and unplug it from the
socket.

The plastic parts may melt and cause fire.

Do not put your fingers Continuing to operate the unit may result in
or any long object, into fire, electric shock, or malfunctions.
the air intake/outlet. Contact your dealer or Mitsubishi Electric Service
Do not touch the swing Centre for consultation.
louvre.
Remove water that has collected in
The internal fan rotates at high speeds, the tank.
and such actions may result in injury or
malfunctions. Accidentally drinking the water or using it for
other purposes may cause illness and/or
unforeseen accidents.

e_mj_e26cx_h.indb 4 2009/10/26 17:22:19


CAUTION
Do not cover an air outlet or Do not use the unit for special
air intake with laundry, cloth, purposes, such as
curtain, etc. preservation of food,
This results in poor ventilation and art or scientific works.
may cause heat generation/fire. This may negatively
affect the quality of the items stored.
Do not put vases or any other
objects filled with water on the unit. Do not point airflow from the
Water may leak into the unit adversely unit directly at the body for
affecting electric insulation and cause a prolonged period of
time.

E
electric shock and/or fire by short-
circuiting. Be especially careful when
using the unit where there
Do not use the unit in a is someone who is unable to adjust the
bathroom or other humidity (infant, child, or elderly person).
location where it is If air-ow is directed at the body for long
likely to come into periods, it may harm ones physical condition
contact with water, or wash it with and lead to dehydration.
water.
Exposure to water may result in fire or electric Do not stand on, sit on or lean

Before using the unit


shock caused by an electric leak. against the unit. Do not pull the
unit by the downward air outlet.
Do not use the unit As the unit is on wheels, it may move, tip
where it may be exposed over, or fall causing personal injury.
to direct sunlight or other
weather conditions. Do not remove the
Styrofoam from the
(This unit is for indoor floating element.
use only.) The oating element will not
This may cause overheating, electric shock be able to detect a full tank
and/or fire caused by an electric leak. resulting in water leakage,
which may damage surrounding
Do not use the unit in objects or cause electric shock and/or
narrow, enclosed places an electric leak.
such as inside closets,
between pieces of Do not drain water continuously
furniture, etc. if there is a possibility that
temperature around the hose
This results in poor ventilation and may
could drop to freezing point.
cause heat generation and/or fire.
Water inside the hose may freeze and
Do not use combustion prevent the water in the tank from owing
appliances in the path of out. The water may leak from the unit and
damage surrounding objects.
the air outlet.
This may cause Install the unit in a location where
incomplete combustion the floor is flat and stable.
in the appliance. If the unit falls over, the water collected
in the water tank may leak damaging
Do not use the unit in places that surrounding objects and in turn result
may be subject to oil or flammable in fire or electric shock caused by an
gas leakage. electrical leak.
Such a leak around the unit may cause
combustion and fire. Before moving the unit always
switch it off, unplug it and remove
Do not use the unit in places water from the water tank.
where chemicals are used Moving the unit with water in its tank may
(such as hospitals, factories, cause the water to leak and damage the
laboratories or beauty salons). surrounding objects and in turn result
in electric shock and/or an electric leak.
Chemicals and solvents evaporated in
the air may harm the unit and cause After emptying the tank, transport the
water in the tank to leak, resulting in unit by grasping the handle firmly.
damage to property. Losing your footing while carrying the
unit may cause personal injury or
damage to the floor.

e_mj_e26cx_h.indb 5 2009/10/26 17:22:19


Precautions (Cont.)

CAUTION Names and Funct


Grasp the plug and remove
from the power socket. Front
When removing the plug from
the power socket, do not pull
on it diagonally or by the cord as this
may cause the projections/wiring to be
damaged resulting in a short circuit,
electric shock or fire.

Switch the unit off and


unplug from the power
source when cleaning it.
When the unit is on, the internal
fan rotates at high speeds and may
cause injury.

Unplug the unit from the power


source when not using the unit
for an extended period of time.
Otherwise it may cause fire and/or
electric shock caused by an electric
leak.

When draining water


continuously or left unattended
for long periods, inspect the unit
every two weeks.
Do not allow debris to clog the lter/
hose as this may cause overheating/
leakage.

When using the continuous


drainage outlet, make sure
to position the hose so that
the water drains without Sensor
obstruction. Do not cover
The water in the tank may leak and
damage surrounding objects.

Use the unit with caution in Accessory


rooms where the walls, furniture
and art work are vulnerable to Silver ion sterilizing and deodorizing
dry air, as it may cause cracks filter
and warping. (Hereafter referred to as simply sliver ion lter.)

Warning The silver ion lter is supplied with the unit at the
time of purchase. Set before using the unit. P10

Keep the unit always in an upright position.


Inclining the unit may cause water in the tank to leak What is silver ion filter?
into the unit, resulting in malfunction. Should you The silver ion lter has a tow-layer construction consisting
incline the unit accidentally, contact the place of of a white particle lter and a blue air-freshener lter.
purchase for advice. <Particle lter>
Do not carry the unit horizontally. The ne particle lter removes pollen* and dust particles.
* Diameter of pollen: approx. 10-100m
This may result in malfunctions.
<Silver ion lter>
Such malfunctions are NOT A special deodorant and anti-bacterial agent (anti-
covered under warranty. allergen, anti-virus and sterilization) are contained in the
bres of the silver ion lter.
Cigarette smoke and toxins found in smoke, such as
carbon monoxide, cannot be removed with this lter.

e_mj_e26cx_h.indb 6 2009/10/26 17:22:20


ctions of Parts
Back
Louvre P16 Handle P10
Main Air Outlet Rear Air Intake

Silver ion filter P22~23


Control panel

E
Pre-filter P22
Downward louvre P16

Downward Air Outlet

Tank lid P1020

Before using the unit


Tank Guard P1020
Storage Hook

Floating Element P20 Cord Tie


Remove during operation
Water Tank P1020
Level window Power plug

The water tank may contain water


residue at time of purchase. This Continuous
Wheel (4) P10
is from nal product testing at drainage outlet
the factory and is not due to a P21
defect.

Installing your
dehumidifier
Make sure to leave some
At least 50 cm
space around the unit.

At least 20 cm
At least 20 cm

At least
<Operating noise>
20 cm
Use the unit on a mat or the
like. This reduces vibration and
noise. It also prevents leaving
depressions on carpets, etc. At least 20 cm

e_mj_e26cx_h.indb 7 2009/10/26 17:22:20


Names and Functions of Parts (cont.)

Control Panel
SWING LOUVRE Switch DRYING INSIDE lamp
Sets the swing louvre direction or Flashes during
locks it into position. the drying inside
operation.
P16
Lights when the drying
Tank FULL lamp inside operation is
Lights when the tank is full waiting to begin.
of water. DRYING INSIDE switch
Lights when the tank is not Use this to switch the
attached to the unit. internal drying operation
ON and OFF.
P20
P19

POWER lamp
Lamps ON/OFF TIMER Switch Lights during operation.
The lamp for the Sets the time of the timer. POWER switch
selected mode lights. P17 Turns the power ON/OFF.
SELECTION Switch MODE Switch
Switches the operating P12
Switches between
mode. DEO-DRY lamp
EASY DEHUMIDIFYING
HUMIDITY SELECTION Lights during deodorizing clothes operation.
operating mode
Switch DEO-DRY Switch
and INTELLIGENT
Sets the humidity. Switches to deodorizing clothes operation.
LAUNDRY operating
mode. P13~15 P18
P12~13
CHILD LOCK
To set the child
lock, press the
mode button for
three seconds.
P14

HIGH
LOW
EASY DEHUMIDIFYING
BATHROOM MILDEW
INTELLIGENT DEO-DRY
GUARD
LAUNDRY
LOW TEMP
AUTO

You can select one of the above eight operating modes. It is not possible to use a
combination of two operating modes.

e_mj_e26cx_h.indb 8 2009/10/26 17:22:20


LCD Display
All of the indicators on the LCD display are shown for explanation purposes.

Operating Mode
Indicator

E
Indicates the selected
operating mode.
P13~15

Before using the unit


Humidity Indicator Swing Monitor Timer Display
Indicates the approximate Indicates the swing Indicates the time of
humidity. direction. the ON/OFF timer.
P16 P17
Indicates the current humidity
(within the range of 30% to 80%). Child Lock Indicator
When the humidity is 30% or lower, Indicates the child
30% is indicated. lock is activated.
When the humidity is 80% or
higher, 80% is indicated. P14

Indicates the set humidity (only in


AUTO MODE).

Information Display
Indicates the dehumidier and room conditions.
Low Temperature Defrost Indicator High Humidity Warning
Indicator

If the room temperature drops When is indicated, blowing If the humidity in the room rises to
to approximately 15C or (dehumidifying) is stopped and the 75% or higher when the unit is OFF,
lower during operation, is frost that has accumulated inside ashes to notify you.
indicated to notify you. melts and drops into the tank . Please Dehumidifying is recommended
Activating LOW TEMP mode wait a while as operation will resume when is ashing.
is recommended when is in around 5 minutes.
indicated. P14 In DEFROST mode, blowing
(dehumidifying) and the louvre are
stopped and the sound coming
from the unit changes.
Defrosting starts automatically when the
room temperature drops to 15C or lower.
(This may be as often as once every For not using the high humidity warning,
approximately 40 minutes.) remove the power plug.

e_mj_e26cx_h.indb 9 2009/10/26 17:22:21


Before using your dehumidier
Set the silver ion lter Inserting the water
The silver ion lter is supplied with the unit at time of tank correctly
purchase. Please t before using the unit.
Check the tank and tank guard,
1 Remove the silver ion filter
from the polyethylene bag.
and insert the tank all the way in.
Tank lid
Tank guard
Make sure the tank
2 Remove the pre-filter. is inserted correctly

Pull the pre-filter


toward you, and
then remove it.

Tank
Make sure the tank is not broken or cracked

Performance is unaffected even if the metal ns


Plug the power cord
inside the main unit are slightly bent. into the power socket
Use a 220-240V AC
Set the silver ion filter into the
3 pre-filter.
power socket only.

With the strips facing up, set the silver ion The current humidity
filter inside the tabs on the pre-filter. is indicated.
Strips
If the louvre is open, it closes automatically.

Tabs (4)
Carrying the Unit
The unit can be transported using the wheels on the bottom.
Check that the water tank is empty and the louvre
is shut before transporting.
4 Set the pre-filter.
Raise handle to transport
Insert the bottom
tabs into the unit The unit may become difcult
until they click.
to move depending on the
direction of the casters. Using
excessive force to move the unit
may cause the unit to fall over.
Do not hold the louvre when
moving the unit.
Do not attempt to carry the unit horizontally.
Make sure the silver ion lter is attached to the unit. Tilting the unit will result in the water spilling and
Note

If it is not, ne dust will enter inside the unit and cause a malfunction.
cause a malfunction. Use the wheels on hard at surface.
Note

Lift over doorsills and steps. Refrain from using


the wheels on thick-pile carpet, as this may
damage the carpet.
Do not let the power cord get tangled in the
wheels. Additionally, do not let the power cord
drag, as this may damage the cord.

10

e_mj_e26cx_h.indb 10 2009/10/26 17:22:21


Tips on Drying Laundry
To dry laundry quickly and neatly

How to Hang Clothes

Fully extend the clothes to remove any wrinkles.


Leave space between clothes to allow air to easily pass
through them (Guideline for spacing: Approximately 5 cm)
Hang any difficult to dry items in positions where wind can

E
easily come into contact with them.
Clothes placed close together will take time to dry.

<Drying takes a long time in the following cases>


When there are a lot of clothes
When the room temperature is low P3
The drying time required at a low temperature (approximately 10C)
is around twice that at a normal temperature (approximately 20C).

Before using the unit


When the room is large P12~13

How to Blow Air at Clothes

Use the swing louvre to blow air onto all of the clothes P16
Clothes places in locations that are not exposed to the wind will
take time to dry.
When there are a lot of clothes
Change the hanging positions of the clothes during drying to
ensure air is blown onto all of the clothes.
About the Room for Hanging Clothes

Hanging the clothes in a small enclosed room and


dehumidifying.
It allows for very efcient dehumidifying and quick drying.
When the room temperature is low such as during the winter
Drying becomes easier if you also use a heater to raise the room
temperature to approximately 16C or more.

Using the unit to dry clothes hung in a room is recommended on days such as
the following.

z Cloudy and rainy days z Days with a lot of pollen z Days you are unable
and dust in the air to bring in the washing
during daylight hours

Drying clothes hung outside takes Hanging clothes inside enables Dry clothes absorb dampness
a while on days with high humidity you to prevent pollen and dirt when the air cools outside after the
because it is difcult for water to getting on them. sun sets, meaning your efforts will
evaporate. have gone to waste.

11

e_mj_e26cx_h.indb 11 2009/10/26 17:22:21


When you want to perform automatic
The unit performs operation automatically while monitoring the temperature and humidity in the room, thus alleviating
the need for advanced operation settings.
Use EASY DEHUMIDIFYING when you want to dehumidify the room and INTELLIGENT LAUNDRY when you want to
dry laundry.

2 1

The compressor does not activate immediately


1 Press after turning the unit off, or after plugging the unit
into the power socket. (This is in order to protect the

Information
compressor.) Dehumidifying begins approximately
The POWER lamp lights. 3 minutes after you press the POWER switch.
The current humidity is displayed. When dehumidifying begins, the operational noise
The louvre opens and airflow starts. increases.
The unit remembers the operating mode. Even if the
plug is disconnected or the power turned off, the unit
restarts at the previous setting.

2 Press to select the EASY DEHUMIDIFYING


The unit operates intermittently controlling the
operating mode airow to remove the damp feeling in the air. When
the room temperature is high, the blower operates
Changes with every press. to reduce the rise in room temperature.
Select this when you want to maintain a
comfortable humidity level
Once the set humidity level is reached the airow
and louvre operations will stop.
INTELLIGENT LAUNDRY Operation
Use the swing louvre and make sure that air is Rough Guide
Size of room Up to approx. 21 m2
on Usage
blowing onto all of the clothes P16
EASY DEHUMIDIFYING Operation Keep usage within the ranges specied in Rough
Use the swing louvre as desired. Guide on Usage to ensure efcient drying.
Press the HUMIDITY SELECTION switch If the room is large, the humidity level may not
Information

during operation in EASY DEHUMIDIFYING or fall to the set humidity level.


Set Humidity Level (%)

INTELLIGENT LAUNDRY mode to switch to the


60
AUTO operation. P13
50
<To stop operation> Room
20 27 30
Temperature
Press (C)
If the room temperature is below
27C, the unit changes the set
The POWER lamp goes out.
humidity level according to the
The operating mode indicator
room temperature, and starts
disappears.
dehumidifying.
If the drying inside operation (auto) is
Information
set, it starts after operation stops. P19
If the room temperature is above 27C, the unit
dehumidies until the humidity level reaches 50%,
and then activates the blower. The dehumidier is
reactivated when the humidity level rises to 60%.

12

e_mj_e26cx_h.indb 12 2009/10/26 17:22:22


operation When you want to
perform manual operation
You can select from ve operating modes: HIGH, LOW, BATHROOM
MILDEW GUARD, LOW TEMP, and AUTO. (HIGH, LOW, and LOW
TEMP: P14 , BATHROOM MILDEW GUARD: P15 )

AUTO When you want to set the humidity and perform dehumidifying

E
2 1

1 Press P12

2 Press to select the operating mode


A border is
displayed around
AUTO.
INTELLIGENT LAUNDRY
Operations in which the unit controls
the airow while monitoring the
humidity of the room, and estimates Information You can also switch to AUTO with the MODE switch.
when the laundry will dry, and
stops the unit automatically. These AUTO
The unit changes the airow rate automatically and
operations are performed for a period operates intermittently to maintain the set humidity.
of time ranging from approximately 1 If the current humidity becomes lower than the set
hour to 12 hours. humidity, the unit stops dehumidifying (blowing and the
louvre are stopped). If the current humidity becomes
Amount of higher than the set humidity, the unit resumes operation.
Rough Size of room Operation is performed for approximately 6 minutes
laundry

Operating
Guide on after you turn the power ON, regardless of the humidity
Up to approx. Up to approx. of the room.
Usage 2
17 m 6kg The humidity may not become lower when the door
Information

Keep usage within the ranges of the room is opened and closed frequently or
depending on the size and conditions of the room.
specied in Rough Guide on Usage
to ensure efcient drying. <Checking the set humidity and setting the humidity>

Press the
Press
switch again.
Drain the tank before use. Press the switch once Pressing the
The unit may stop before the laundry to display SELECTION switch again while
dries because of a full tank.
and then the current SELECTION is
humidity setting. displayed allows you to
If this is used in conjunction with the set the humidity setting.
off timer, operation may stop before
Information

Each time the switch is


the clothes are dry. P17 After 3 Sec. pressed, the humidity
When the room temperature is setting changes.
The indication changes to
approximately 5C or less, operation the current humidity after 70 65 60 55 50
stops after about 1 hour because the approximately 3 seconds.
evaporation of moisture becomes
difficult and the clothes will not dry.
In such a case, use the unit with <To stop operation>
dehumidifying set to HIGH.
Press P12

13

e_mj_e26cx_h.indb 13 2009/10/26 17:22:22


When you want to perform
manual operation (cont.)
Using Child Lock
You can lock the switches.
You can select from ve operating modes: HIGH, LOW, Use this function when you want to stop children
BATHROOM MILDEW GUARD, LOW TEMP, and AUTO. operating the unit.
(AUTO: P13 , BATHROOM MILDEW GUARD: P15 )

HIGH LOW LOW TEMP

Press for 3 or more seconds


2 1 Child Lock Indicator

1 Press P12 If you lock the unit when the POWER is OFF.
The unit will not turn on, even if you press the
POWER button to turn it on. Only the CHILD
LOCK lamp will blink.
2 Press to select the
(Pressing the POWER button again will
operating mode cause the lamp to turn on solidly.)
Changes with every If you lock the unit when the POWER is ON.
press. The unit will not turn off, even if you press the
POWER button to turn it off. Only the CHILD
A border is
LOCK lamp will blink.
displayed around
(Pressing the POWER button again will
the selected
cause the lamp to turn on solidly.)
operating mode.
Only the CHILD LOCK switch can be operated while
Information

HIGH the child lock is set. The other switches become no


The unit operates continuously with a HIGH longer operable, so deactivate the child lock to use
airow rate. Select this when you want to the other switches when you want to operate them.
The child lock is switched off when the power cord is
dehumidify at a high level.
unplugged and plugged again.
LOW
The unit operates continuously with a LOW <When you want to release the child lock>
airow rate. Select this when you want a
reduced blowing sound during dehumidifying.
LOW TEMP Press for 3 or more seconds
The unit changes the airow rate according
to the room temperature, and performs The child lock indicator disappears.
continuous operation. The airow
rate becomes the maximum when the
temperature is approximately 15C or lower.
Activating the LOW TEMP mode is
recommended when is indicated. P9
Even if the LOW TEMP mode is activated, Preventing condensation on
Information

condensation may form on window glass windows and dehumidifying


that comes into contact with the outside the inside of closets or
air when the air temperature is low.
shoeboxes
The humidity cannot be set in the HIGH, Use the swing louvre to blow
Information
LOW, and LOW TEMP modes. air at the location you want to
dehumidify.
<To stop operation>
<Recommended Operating Modes>
Press P12 LOW TEMP, HIGH

14

e_mj_e26cx_h.indb 14 2009/10/26 17:22:22


Reducing Growth of Mildew in Bathroom (Bathroom Mildew Guard)
This operation is for reducing the growth of mildew by drying the inside of a bathroom to remove any humidity and droplets that
remain inside after, for example, you take a bath. This operation can also be used as a measure for tackling mildew in rooms.

Installing the Dehumidifier Install the dehumidifier in the

Preparation
Install the unit in the dressing room (entrance to
dressing room
the bathroom). Adjust the downward blowing louvre as desired.
(Do not install the unit inside the bathroom.) P16

Set air to be blown from


the downward air outlet. 1 Press P12

E
Adjust the orientation of
the unit so that air ows
toward the whole room.

2 Press to select
BATHROOM MILDEW GUARD
Changes with every
press.
If water remains in the
bathtub, cover the bathtub. A border is
displayed around
the selected
operating mode.
Start operation

CAUTION
(Air is blown from the downward air outlet.)

Do not use the unit in a bathroom or other location where it is Operation stops
likely to come into contact with water, or wash it with water. after approximately 4 to 12 hours.
The unit does not have a drip-proof or water-proof
structure. Water coming into contact with the unit may The POWER lamp goes out and the
result in a re due to a short circuit, or an electric shock. operating mode indication disappears.
Rough Guide on Usage Air is blown from the downward air outlet
Location to be dehumidied Size automatically to dry the oor surface. When you
want to dry the walls and ceiling, change the
Bathroom (bathroom + Up to approximately 7m2 (size of direction of the swing louvre. P16
dressing room) bathroom + dressing room)
When you want to use other than the downward air
Room Up to 21m2 outlet, adjust the orientation of the unit.
For more effective operation, use the unit within the above ranges. The airow rate cannot be set because it is
changed automatically. It is also not possible to use

Operating
For effective use, keep the windows and doors of the room
closed and do not ventilate the room during operation. this in conjunction with another operating mode or
Operation may not be sufciently effective if the to set the humidity.
bathroom is spacious or because of the building
materials used for the oor and walls of the bathroom. <When you want to abort the operation>
Drops of water may remain in places where water collects easily.
Information

Mildew may grow depending on the room conditions When you want to end the operation
and the type of mildew. partway through:
Example: Where air circulation is poor such as beneath
a container or the like in the bathroom or at the back of Press the POWER switch (OFF).
a cupboard or behind furniture in the bathroom. When you want to switch to another
This operation cannot dry locations where the airow cannot
reach such as inside a bathtub and beneath a container. operation:
This operation cannot remove existing mildew and Press the MODE switch or SELECTION
water scale, or slime in the drain outlet.
If this operation is used in conjunction with the off switch.
timer, operation may stop before drying is complete.

About Bathroom Mildew Guard Operation Humidity 50%


After dehumidifying is performed until the humidity reaches 50%,
operation is performed for approximately 4 hours and then stopped Varies depending on the
Operation time temperature and humidity 4 hours
automatically. The operation time varies depending on the temperature
and humidity, but the minimum time is approximately 4 hours Swing direction Downward
(approximately 6 hours when the room temperature is 20C or less) and Start of End of
the maximum time is approximately 12 hours. operation operation
How is mildew growth suppressed? Identication of Black Mold
Mildew is unable to produce new spores if dried as mycelia. The Mildew Guard feature applies [Research paper by Dr.K.Abe of the
this principle. (However, the spores themselves are resilient to dry conditions.) Environmental Biology Research Center]
15

e_mj_e26cx_h.indb 15 2009/10/26 17:22:23


Using Louvre
The louvre can be made to swing. Select from the 5 possible settings to suit the purpose.

Changes
Stop swing
with each
press the
swing
direction. Wide

During
operation,
Press to select the Upward

operating mode
The swing monitor indicates the range in Downward
which the louvre swings. (The movement of
the louvre and monitor do not match.)
Rear

Objective Recommended swing mode Explanation of swing

To stop the Stop swing The louvre stops and the swing monitor disappears.
louvre at the Wait until the louvre stops and then adjust the angle by
desired angle hand.

Wide swing
The louvre swings so that air is blown over a wide area.
To cover the
The blowing range is approximately 135. (The moving range
entire room of the louvre is approximately 120)

Swing speed is automatically controlled to send air to clothes


Upward swing from the angles.
The blowing range is approximately 90.
For drying 60
30
clothes, etc.
The louvre moves slowly through the last 30 of the swing,
as the time taken to traverse the rear arc is shorter than
that for the upward arc when moving at a constant speed.

Air is blown from the downward swing


To dehumidify outlet. The louvre does not swing.
carpets and Downward Move the downward louvre by hand to
beds, adjust the angle. (Can be adjusted to
three positions)
To dry training The louvre may open slightly to adjust the Hold the edge of the
shoes direction of blowing, so do not close the downward louvre and
louvre if this occurs. move it.

Rear swing The louvre will swing so as to blow air toward the backside of
To dehumidify the unit.
The blowing range is approximately 60.
closets Depending on the angle of the louvre, some air may also blow out
from the downward outlet.
The swing operation stops when the power cord is unplugged.
Information

The level of noise emitted from the unit varies according to the angle of the air-ow.
The louvre may stop for up to about 8 seconds to adjust its position, but will start moving again afterwards.
If the louvre is knocked out of the desired angle because the louvre is touched by a hand or object, press the SWING
LOUVRE switch again to readjust the position.
If air is blown directly onto a wall, the wall may become dirty because of dust in the air being blown onto the wall.
When you want to dry training shoes, place them at a position that is a little higher than the oor.
16

e_mj_e26cx_h.indb 16 2009/10/26 17:22:23


Using Timer
When using the timer, drain the water from the tank before beginning operation. When the tank becomes full of water,
dehumidifying cannot be performed because operation stops.

OFF Timer Operation ON Timer Operation


You can set an operating time between 1 to 9 hours. You can set an operating start time between 1 to 9
Set the time when you turn the power ON. hours. Set the time when you turn the power OFF.

E
2 1 2 3 1

1 Turn the power ON P12 1 Turn the power OFF P12

Set the desired operating mode and swing

2 Press to select the


direction. P12~16

operating start time


2 Press to select the If you press the switch once, the POWER
operating time lamp, operating mode indication, and
flash, and is displayed.
If you press the switch once, and Each press changes the indication
are displayed. in the order of 1 to 9 hours (the
Each press changes the indication in the indication changes automatically if
order of 1 to 9 and no indication (cancel) you continue pressing the switch).
(the indication changes automatically if you
continue pressing the switch).
Off Timer Operation Starts
<Display example> 3 Press to confirm the
Humidity setting operating start time
(set to 60%)
Swing WIDE The POWER lamp and time indication flash
Off timer is set On Timer Reservation Completes
to 2 hours
The time indication and operating mode
The remaining operation time indication indication ash and an alarm sounds to

Operating
is reduced by 1 as each hour elapses. notify if you forget to press the switch.
When the set time elapses, operation (The alarm (pipi...) sounds for one minute.)
stops and the louvre closes automatically.
The POWER lamp goes out and the <Display example>
operating mode indication disappears. Humidity setting
(set to 60%)
When the drying inside operation (AUTO) is set, Swing WIDE
the drying inside operation is performed. P19 On timer is set
to 5 hours

<When you want to cancel the timer


The remaining time until operation
before the set time elapses> indication is reduced by 1 as each
When you want to end operation hour elapses.
Press the POWER switch (POWER OFF). When the set time elapses, operation
When you want to cancel the off timer starts.
and continue operation
Press the ON/OFF TIMER switch repeatedly <When you want to cancel the timer
until the remaining time indication before the set time elapses>
disappears (returns to continuous operation).
Press the POWER switch (POWER OFF).
The off timer and on timer cannot be set at the same time.
If you set the on timer during the drying inside operation,
Information

If you use INTELLIGENT LAUNDRY or BATHROOM


Information

the drying inside operation is cancelled.


MILDEW GUARD in conjunction with the off timer, the
The on timer operation cannot be performed with a
operation may stop before drying is complete.
commercially available power socket that has a timer.
The off timer cannot be set while the drying inside
operation is being performed.
17

e_mj_e26cx_h.indb 17 2009/10/26 17:22:23


Removing Odor from Clothes (Clothes Deodorant)
The unit operates for approximately 1 hour to remove odor from clothes. <Use for odor from the following>
Use this operation when you want to remove odor from clothes that are not
frequently washed, such as suits and sweaters. Cigarettes and grilled meat

Preparation
How to Hang Clothes Hang the hangers on which the
clothes are hung, and then place
Secure hangers so they will Space out
not be moved by airow. laundry to the dehumidifier beneath them.
improve airow.

1 Press P12

2 Press
The DEO-DRY lamp lights.

The airow rate cannot be set because it is


Fasten the buttons changed automatically. Do not use this operation
in conjunction with other operations.
on suits, coats,
and the like.
Allow 3 Press to select the
pants When odor is louvre swing direction. P16
to hang absorbed into
unfolded. the fabric, allow The odor will not be removed from parts not
blown by the wind. Select a swing direction
air to blow inside that enables a good amount of wind to
the hanging blow the clothes.
garment.
Operation stops after approximately 1
Do not use for leather and silk goods. hour.
Note

Drain the water tank before operating. The POWER lamp and DEO-DRY lamp
Ensure ventilation during operation.
go out.
The odor cannot be removed in the following cases.
When the temperature and humidity inside the <When you want to abort the operation>
room are low Pressing the DEO-DRY switch does not abort
When there are many clothes the operation.
The odor will not be removed from parts not blown by (The deodorant dry operation starts again.)
Information

the wind.
The sharp odor such as perfumes and chemicals When you want to end the operation
cannot be removed. partway through:
The odor of oil and dirt on clothes cannot be removed. Press the POWER switch (OFF).
If the operation has little effect, try the operation
again, or wash or clean the clothes.
When you want to switch to another
The humidity in the room may rise as a result of the operation:
discharging of moisture that builds up inside the unit. Press the MODE switch or SELECTION switch
Discharged moisture may appear white depending to change to the dehumidifying operation.
on the temperature and humidity in the room.

<Details on Clothes Deodorant Operation> This operation takes approximately one hour.
CLOTHES DEODORANT switch (ON)

Clothes deodorant operation (Approx. one hour.)


Dehumidifying Airflow stops and the compressor operates Blowing Dehumidifying
Auto Stop

operation The heat exchanger is The moisture on operation


Moisture is collected on heated ( is displayed the heat exchanger The moisture is vaporized
Operating
the heat exchanger while during compressor is discharged and and the odorants are
sound
deodorizing is performed operation). the odorants on removed by blowing
the clothes are
by the lter of the unit. warm air.
absorbed.
Approx. 15 minutes Approx. 20 minutes Approx. 25 minutes

18

e_mj_e26cx_h.indb 18 2009/10/26 17:22:24


Drying Inside Operation
The inside of the unit can be dried to suppress mildew growth on the cooler.
On days the dehumidier is used, internal drying is recommended.

Automatic operation Manual operation


To activate internal cleaning after every use.
Press the to activate internal cleaning while
the unit is OFF.

Press while

E
the power is ON. Press while
the power is
Drying inside operation standby OFF.
(The DRYING INSIDE lamp lights)
The drying inside operation starts
The DRYING INSIDE lamp ashes and
the current humidity indicator turns off
The operation ends the louvre stops in the vertical position
The drying inside operation starts
Drying inside operation
The DRYING INSIDE lamp ashes, the
current humidity indicator turns off, and The drying inside operation ends
the louvre stops in the vertical position The DRYING INSIDE lamp turns off and
the louvre closes
Drying inside operation
The drying inside operation ends
The DRYING INSIDE lamp turns off and <When you want to abort the drying inside
the louvre closes operation>
When you want to end the operation
<When you want to deactivate automatic partway through:
operation> Press the DRYING INSIDE switch.
Press the DRYING INSIDE switch (The DRYING INSIDE lamp turns off)
while the unit is ON When you want to switch to another
(The DRYING INSIDE lamp goes out) operation:
Press the POWER switch.

Operating
Connecting/disconnecting the power plug deactivates automatic operation.
This function does not remove existing mildew. Also, aborting drying inside operation may cause the benets to diminish.
Information

Do not close the louvres while drying inside operation as this causes noise.
The moisture expelled from inside the unit may cause the humidity level of the room to rise.
The air leaving the unit may appear white depending on the humidity or temperature of the room.
The moisture expelled from inside the unit may smell due to odorants* that were not caught by the lter dissolving in the water.
* The silver ion lter is mainly for absorbing ammonia.
The OFF timer cannot be set during drying inside operation.

<Details on drying inside operation> This operation takes approximately one hour. However, when
the room temperature is below 1C, drying time is shored to
protect the compressor.
OFF

Drying inside operation (approx. one hour.)


Regular Airflow Airflow stops; compressor activated
Operating
Compressor Airflow Unit stops
Drying is performed Drying is performed by heating stops Drying is performed
Operation by blowing wind the heat exchanger sound by blowing wind automatically
Approx. 30min. Approx. 20min. (Varies according to the room temperature) Approx. 10min.

19

e_mj_e26cx_h.indb 19 2009/10/26 17:22:24


Draining
The unit automatically shuts down and lights the Tank full lamp when the tank is full.
Empty the tank.

When the tank becomes full, the FULL lamp lights.


After removing the water and replacing the
tank, the Tank full lamp will go off, and the

Information
unit will automatically return to operation
mode.
Tank full lamp lights. When the Tank full lamp is lit, no operation
(The unit beeps continuously). but ON/OFF is possible.
Blowing stops (louvre stops). When using the OFF timer, you are only
The operation indicator lamp turns off. notied by the FULL lamp lighting.

1 Remove the water tank. 3 Slide the tank lid to close the
tank.

Grasp handle and


slide out.

If you remove the


tank, the FULL lamp
lights.

Check the tank, and firmly


<Hold the tank this way> 4 push it all the way in.
Tank lid
Tank guard
Make sure it is
inserted correctly
Remove the tank lid, and pour
2 out the water.
Tank lid
Tank
Tank guard Make sure the tank is not
broken or cracked

A beep is heard and the lamp turns off.

Secure the lid and guard properly or else the tank


Information

may become stuck.


If the tank is not installed correctly, the tank full light
will come on, and the unit will not operate.
Floating element
Do not remove this. Do not remove or dismantle the oating element in the
Note

tank. If it is removed, the unit cannot detect when the


Pour the water tank is full, and this could result in leakage.
out as shown.

20

e_mj_e26cx_h.indb 20 2009/10/26 17:22:24


Continuous Drainage
If a drain is available, the unit can continuously drain excess water by attaching a commercially available hose
(internal diameter 15mm).
The unit can be operated for extensive periods without the need to empty the water tank.

Commercially available hose (I.D. 15mm)


Items to
prepare
Long enough to reach the drain. CAUTION
Pincers Do not drain water continuously if there is
a possibility that temperatures around the
How to set up the drainage hose hose could drop below freezing point.
Correctly Incorrectly hose immersed in water Water inside the hose may freeze and water may leak
from the unit and damage surrounding objects.

E
installed installed hose raised to a level
higher than the drainage When draining water continuously or left
outlet unattended for long periods, inspect the
The water will not unit once a fortnight.
drain. Foreign objects, etc. could clog the hose resulting in
overheating and/or leakage.

4 Insert hose onto the drainage


Preparation

Turn the POWER switch OFF, and


remove the power plug. outlet from the back.
1 Feed the commercially available hose (ID 15
Remove the mm) onto the drainage outlet while keeping
1 water tank. the stopper pressed.

2 Open the drainage outlet. 2 Firmly push the hose


through the drainage
Position of drainage outlet outlet of the unit.

Operating
221mm
Hose

114mm

Use pincers to cut away the three securing 3 Check for water
ribs of the continuous drainage outlet. Remove leakage.
carefully without letting any debris fall inside.

3 Press drain stopper.


Attach the tank and set the
5 end of the hose to the drain.
Drain If the tank is not reattached, the FULL lamp
remains on and operation is not possible.
Stopper

Push here

Conrm that the hose does not show signs of deterioration such as bending cracks and clogging.
Note

Inspect the hose every 2 weeks. Insects or dirt blocking the hose may cause leakage resulting in malfunctions.

21

e_mj_e26cx_h.indb 21 2009/10/26 17:22:24


Do not use detergents, cleaning agents for heat exchange equipment, abrasive

Maintenance powders, chemically treated dusters, gasoline, benzene, thinners or other solvents,
as they can damage the unit or the water tank, which may result in leakage.

Remove the power plug before you begin maintenance.

Cleaning Once Every Three Months


Water tank Main unit Silver Ion Filter
Wipe with a soft cloth. Soak the silver ion lter in water.
How to remove and attach P10

1 Remove the pre-filter.

2 Remove the silver ion filter.


Floating element
Do not remove or dismantle. Soak the silver ion filter in
The unit draws in dust present in the air, and this 3 water.
may cause the tank to gradually become dirty. If
the dirt does not come off easily, wash with cold
or warm water, then wipe with a soft, dry cloth. Soak in cool to
Mildew may form in the tank unless kept clean. lukewarm water for
After cleaning the tank, attach the tank guard and
then set the tank in the unit. about 30 minutes.

Once Every Two Weeks Do not use detergent or hot water. Also, do
not use a brush or the like to scrub the filter

Pre-lter and sensor part or rub the filter while soaking. This may
damage the filter.
Clogging with dust and the like reduces the Any yellow or dark stains may remain on the
effectiveness of dehumidifying. Clean about once lter, but should not affect performance.
every two weeks.
How to remove and attach P10 The lter can be soaked for a total of eight
times. After that, replace with a new lter.

1 Remove the pre-filter. 4 Dry the silver ion filter well.


2 Remove the silver ion filter. Dry the lter on a even
surface in the shade.
3 Clean the pre-filter. Do not hang with pegs or the like. This may
Use a vacuum cleaner damage the filter.
to suck up any dirt. Do not use the filter while wet.

When the lter is very dirty, wash it


in lukewarm water and dry it well. 5 Set the silver ion filter.
Clean the
4 sensor part. 6 Set the pre-filter.
Use a vacuum cleaner
to suck up any dirt.

5 Set the silver ion filter.


Make sure the silver ion filter is attached to
the unit. If it is not, fine dust will enter inside
the unit and cause a malfunction.

6 Set the pre-filter.


22

e_mj_e26cx_h.indb 22 2009/10/26 17:22:25


Replacement Parts Storage and Disposal
The silver ion filter is a consumable item. Storage
Replace this lter when it becomes time for replacement.
After switching the unit off, leave for one day until
any water inside has had time to settle. Then carry
Replacing the silver ion lter out the following steps.
Although the silver ion filter lasts roughly 2
years, replace it when: 1 Perform drying inside. P19

You have soaked the filter 8 times. Performing internal drying to prevent mildew
The silver ion filter has turned brown due to growth is recommended.

E
cigarette smoke or black with dust. Hang the power
2 cord on the
Filter life differs on usage and environmental
conditions cord hook.
Remove the pre-filter from the unit,
and replace the silver ion filter. Drain out the
Removing and setting the filter, see P10
3 water. P20

Drain the water from the


tank and wipe away any
remaining drops of water.

Parts sold separately

Silver ion filter for replacement


4 Clean the pre-filter. P22
Type: MJPR-18WXFT
Type code: 5C5 819
Use a vacuum cleaner to
For these items contact your nearest Mitsubishi suck up any dirt.
Electric dealer.

5 Store the unit.


When you are sure that all parts are dry, cover
it with a cloth to keep it from dust.
Store the unit in an upright position in a place
not exposed to direct sunlight.

When disposing the unit


Dispose according to the garbage regulations in
your district.

Silver ion filter


Material: PET and PS
Troubleshooting

Unit
Do not disassemble. Dispose according to the
garbage regulations in your district.

23

e_mj_e26cx_h.indb 23 2009/10/26 17:22:25


Troubleshooting
For the symptoms listed below, refer to the remedies listed right.
Symptom Cause/Remedy
The unit blows out warm air because dehumidied air passes through
The unit blows warm air the reheater (there is no cooler function). This is not a malfunction. P3

Water does not collect in Check to see if the temperature/humidity is low.


the water tank (minimal Low room temperature/humidity reduces dehumidifying effectiveness.
dehumidifying results) This is not a malfunction. P3

Check to see if the power cord is correctly plugged.


Plug the power cord properly into the power socket. P10

The unit does not operate (No Check to see if anything is blocking the air intake or outlet.
Remove the obstruction. P5
air comes out and the louvre
Is operation being performed with the unit set to EASY DEHUMIDIFYING
does not swing) or AUTO?
The unit is automatically switching dehumidifying, blowing, and stopping. P12~13
The unit stops Is operation being performed with the unit set to Bathroom Mildew Guard?
Operation stops automatically if the humidity falls. Operation stops
after a minimum of 4 hours. P15
Check to see if the pre-lter is clogged.
Clean according to the maintenance procedures. P22
Is operation being performed with the unit set to INTELLIGENT LAUNDRY?
If the room temperature is approximately 5C or less, operation stops after
Stops after approximately 1 hour. If the room temperature is low, it becomes difcult for
P12~13
a short time water to evaporate from clothes because the humidity does not change.
Is operation being performed with the unit set to DEO-DRY?
This operation is designed to end after approximately 1 hour.
P18
Check to see if the water tank is full.
P20
Empty the water tank and return it to its original position.
Lights Check to see if the water tank is inserted properly.
Adjust the position of the water tank.
P10
Check to see if the unit is in defrosting mode. The unit activates
defrosting mode when the room temperature drops below 15C. The
dehumidier and blower functions stop during defrosting. P3
Indicates Is operation being performed with the unit set to DEO-DRY?
is displayed during compressor operation.
P18

The unit continues to operate Is the unit set to drying inside mode?
even though it is turned off This function activates automatically after ending operations. P19

Check to see if the room is not too large.


Check to see if the exits to the room are open.
The humidity level does not
Refrain from opening doors/windows during operation.
drop to the set level easily Check to see if steam producing appliances such as kerosene heaters are on
in the vicinity.

The hygrometer reading on


Hygrometer readings differ from place to place even if in the same room.
the unit differs from other Use the unit humidity reading as an estimate. P3
hygrometers in the room

The louvre does not move as


Press the Swing louvre switch again. P16
set

The water tank contains liquid The residue is from nal product testing at the factory. It is not a result of a
or white water residue malfunction.

There is black residue on the


The residue is from debris in the air.
inside of the water tank and Clean according to the maintenance procedures. P22
lid.

24

e_mj_e26cx_h.indb 24 2009/10/26 17:22:25


Symptom Cause/Remedy
Check to see if the unit is on a slope or uneven surface.
Move to a sturdy even surface. P5
The operating Check to see if the pre-lter is clogged.
noise is loud/ Clean according to the maintenance procedures. P22
reverberates Operating the unit in small rooms or in tight spaces sometimes causes
the sound to reverberate.
Place a mat underneath the unit. P7

E
The operating
sound suddenly The sound increases when the compressor activates (approximately 3 minutes
The unit increases in after turning on the unit or during EASY DEHUMIDIFYING or AUTO).
makes volume
noises The wind sound The volume of the sound differs depending on the angle of the louvre. P16
changes in volume
The unit produces This is the sound of the refrigerant. The sound can be heard while the refrigerant
a simmering sound stabilizes after the unit turns on, changes modes, or stops.

The unit produces This is the sound of the compressor. In modes that monitor the humidity
a buzz that sounds level or during drying inside, the compressor operates intermittently
intermittently (or causing the sound to be heard occasionally. The compressor does not
the compressor activate after turning the unit off, or for 3 minutes after plugging the unit
does not activate) into a power socket. (This is to protect the compressor from damage.) P12

When first used The heat converter heats rapidly causing an odour. This is not a malfunction.

The unit During internal


produces drying The moisture expelled from inside the unit may smell due to odorants that
an odour During were not caught by the silver ion lter dissolving in the water. This is not a
deodorizing malfunction.
clothes operation
The power plug or power
socket generates abnormal Stop operation and contact the place of purchase.
heat

Error message (Humidity indicator)

Digital display Cause/Remedy


, appears in the Check to see if the power cord is plugged into the power socket properly.
CURRENT HUMIDITY indicator Plug the power cord into the power socket properly. P10

Check to see if anything is blocking the air outlet.


Remove the obstruction, and plug the power cord into the power
appears in the CURRENT socket again. P5~10
HUMIDITY indicator Check to see if the pre-lter is clogged.
Clean according to the maintenance procedures. P22

, , ~ appears in the Malfunction


Take note of error message, unplug the power cord, and contact the
Troubleshooting

CURRENT HUMIDITY
indicator place of purchase.

If the symptoms persist even after following the prescribed remedies, or the error message does not
disappear, unplug the power cord, and contact the place of purchase.

25

e_mj_e26cx_h.indb 25 2009/10/26 17:22:25


Specications
Model MJ-E26CX-H
Power supply Single phase 220-240V 50Hz
Dehumidifying capacity 25.0 L/day
Power consumption 415W
Water tank capacity stops automatically at approx. 4.7L
Weight 15.5kg
Dimensions (h w d) 594mm 372mm 281mm

The dehumidifying capacity is a value obtained when the dehumidier is continuously run at a room
temperature of 30C and relative humidity of 80%. It indicates the amount of dehumidication per day (24
hours).
Standby power approximately 1.5W.

NOTE
It is impossible to remove the back
panel because the two spots shown
are fastened with two special screws.
If the unit malfunctions, contact your
Mitsubishi dealer.

Sole Agent in Hong Kong


Mitsubishi Electric Ryoden Air-Conditioning & Visual Information Systems (Hong Kong) Limited.
Ofce: Tel.: 2510 1505 Service Center: Tel.: 2427 8484

Fill in the following for your future reference.

Place of purchase: Telephone number:

Authorised Service Centre: Telephone number:

Date of purchase: Day Month Year

ZT936Z159H51

26

e_mj_e26cx_h.indb 26 2009/10/26 17:22:26

Anda mungkin juga menyukai