Application
Release 1.0
Page 1 of 30
Contents
Page 2 of 30
1. Download SITOP DC UPS Software
Page 3 of 30
2. Installation of Application
2.1. Basic Installation
Execute file Setup_Sitop_3.x.2.x.exe.
Installation is started.
Page 4 of 30
Accept the license agreement.
Page 5 of 30
Select the program components required.
For installation as application the components Application and Driver (when using a
USB connection) are required.
Page 6 of 30
Choose the destination folder in which to instal the program packages.
Page 7 of 30
Select a start menu folder, if you would like to create an entry there.
Page 8 of 30
Typical settings of the SITOP software can be preset here:
Communication interface
Page 9 of 30
Completion of installation.
Page 10 of 30
2.2. Installation USB Drivers
The installation of drivers is only required for versions with USB interface.
Before starting the installation please make sure that the SITOP DC UPS software
(freeware download under www.siemens.de/sitop) is installed completely. Then connect
the SITOP DC UPS module with a free USB interface. The SITOP DC UPS module is
now identified automatically, the hardware wizard opens:
Page 11 of 30
Select Install software from a list or specific location.
Click Next to continue.
In the next window you choose the location from where the driver will be installed,
normally: C:\Program Files\Sitop\DRIVER.
If you have installed the SITOP DC UPS software in a different location, please enter it
in the browse field. Click Next to continue.
Page 12 of 30
Please acknowledge the following warning with a click on Continue Anyway.
In the next window you complete the driver installation with a click on Finish.
Page 13 of 30
Following the same steps, the driver for a new serial COM port is installed.
In this window you complete the driver installation with a click on Finish. The driver for
the SITOP DC UPS module is now installed successfully.
Yon can control in the device manager whether the SITOP DC UPS module has been
identified correctly:
Page 14 of 30
2.3. Update USB Drivers
For the correct function of the SITOP DC UPS software it is necessary to install an
up-to-date USB driver. From driver version 2.2.4.0 upwards this is guaranteed.
If an older driver is installed already, an update of the USB driver has to be made.
Before starting the driver update please make sure that the SITOP DC UPS software
(freeware download on www.siemens.de/sitop) is installed completely.
Search the entry SITOP xx in the folder USB controllers of the device manager.
Mark the entry and by clicking the right mouse button open the context menu
Properties. Here you can check the driver version.
Page 15 of 30
If the driver version is less than 2.2.4.0, an update has to be made. In order to do this
please activate the button Update Driver.
Page 16 of 30
3. Program Operation
Page 17 of 30
3.2. Configuration
Option for display of monitoring window on status change (optionally after a time
that can be set)
Page 18 of 30
Option for starting an application after a set time when buffering
(example: *.exe, *.bat, *.vbs or *.js)
Option for PC shutdown after a set time when buffering (note: if the mains
voltage returns during the set time, the PC will NOT shut down)
Page 19 of 30
Option for starting an application after a set time at ALARM (buffer not ready),
(example: *.exe, *.bat, *.vbs or *.js)
Page 20 of 30
Option for starting an application after a set time at recommended battery
replacement depending on aging (example: *.exe, *.bat, *.vbs oder *.js)
Page 21 of 30
Option for starting an application after a set time at reaching battery charge
>85% (battery fully charged), (example: *.exe, *.bat, *.vbs oder *.js)
Option for starting an application after a set time at falling below battery charge
>85% (battery not fully charged), (example: *.exe, *.bat, *.vbs oder *.js)
Page 22 of 30
3.3. SITOP DC UPS Monitoring
Display of operating states in accordance with the LEDs on the SITOP DC UPS module
DC o.k.
Alarm
Normal mode / buffer mode
Battery charge condition
Buttons:
Page 23 of 30
3.4. Protocol Window
The protocol window opens after clicking the button Protocol.
Display protocol file, all events are registered here with timestamp.
Button:
Page 24 of 30
3.5. Logfile
In the logfile all events are registered and made available for later evaluation.
Page 25 of 30
3.6. Further Settings
Page 26 of 30
4. OPC Server
The SITOP DC UPS software Application has an integrated OPC server interface. This
software interface allows access to information sent by the SITOP DC UPS module out
of own applications.
On clicking the Windows buttons Start -> Run... the following window opens:
As destination the path has to be selected where the program file SITOP_DC_UPS.exe
unpacked in step Basic Installation - is located.
The OPC server can be removed by following the same steps, using the parameter
-unregserver.
Page 27 of 30
4.2. Description of OPC Server Interface
Addressing the OPC server interface implicates an automatic start of the SITOP DC
UPS software Application.
Note: On starting the program a stable data connection to the SITOP DC UPS module is
built up. This process may last a few seconds. A resulting possible delay of data
availability at the OPC server interface must be taken into account.
Table1:
Page 28 of 30
Table 2: Coding status word
The status word consists of 2 bytes, always 4 bits belonging to a LED of the SITOP
UPS.
Page 29 of 30
Note: The information provided in these user instructions contains descriptions or characteristics of performance which in
case of actual use do not always apply as described or which may change as a result of further development of the
products. Technical specifications are subject to change without prior notice, errors excepted.
Page 30 of 30