P R E C I S I O N M I N I AT U R E L E A D S C R E W A S S E M B L I E S
1st Edition
w w w . h e l i x l i n e a r . c o m
TM
HELIX Linear Technologies, a subsidiary of With the release of our new NAB and AAB product lines,
Nook Industries, is the most high-tech lead screw HELIX has even more economical options in the 18"
manufacturing facility in the world. With the release of to 1" diameter range. We have also developed additional
our new precision lead screws, HELIX produces the custom anti-backlash nut designs, which are available
broadest product line of any lead screw manufacturer upon request.
globally. We offer precision rolled, milled, or ground
screws in diameters from 18" to 6", or 3mm to 150mm, HELIX services the expanding and evolving customer-
and leads from 0.024" to 3", or 3mm to 75mm. driven market for precision linear motion products.
When you need Acme, Trapezoidal, or Speedy (high
HELIX offers a complete line of nuts in standard and lead) lead screws with a precision low backlash nut, or
anti-backlash designs with centralizing threads to match a state-of-the-art anti-backlash design, we deliver the
our precision lead screws. Our lead screw assemblies highest quality and exceptional value to our customers.
have the lowest backlash of any nut on the market.
Partners
History Index
Nook Industries, Inc. was founded in 1969 by Joseph Lead Screw Materials & Manufacturing ................... 2-3
H. Nook Jr. and, over the course of the past forty years,
the company has grown to become one of the leading Glossary and Technical Data ...................................... 4-6
manufacturers of linear motion products in the world. End Machining / Mounting Definitions.................................... 7
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of HELIX
Linear Technologies products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
HELIX Linear Technologies manufactures precision Flanges For Bronze & Plastic Nuts
lead screws by thread rolling, thread milling, or thread
Made from carbon steel with black oxide finish. See page
grinding. HELIX lead screw products feature centralizing
8 for instructions on how to secure a flange to a thread
and custom thread forms for smooth, no-wedging
mount style nut.
performance.
THREAD ROLLING
HELIX offers the largest selection of rolled lead screw General Purpose Nut - NAB Series - Flange Mount Style
THREAD MILLING
Milled screws allow more variety in journal machining,
particularly where a design requires the journal O.D. to
be larger than the screw major diameter.
THREAD GRINDING
Anti-Backlash Nut - AAB Series - Flange Mount Style
Ground thread screws offer higher lead accuracy for
applications where positioning tolerances are extremely
critical.
Material: Bronze
Tensile Yield: 50,000 psi
General Purpose Nut - NAB Series - Flange Thread Style
Tensile Ultimate: 65,000 psi
Hardness: HB75
Dynamic co-efficient of friction: 0.125 with
HELIX Lubricant
2
Screw Type Material Thread Class Lead Accuracy Screw Dia. Screw Lengths
HELIX Centralizing .0003 in/in up to Limited only by
Alloy 1
8 to 6
2C or Stub 212 dia. material availability
Rolled
HELIX Centralizing .0003 in/in up to Limited only by
Stainless 1
8 to 112
2C or Stub 112 dia. material availability
HELIX Centralizing 1
2 to 3
Alloy .002/ft up to 96
2C or 3C (single starts)
Milled
HELIX Centralizing 1
2 to 3
Stainless .002/ft up to 96
2C or 3C (single starts)
HELIX Centralizing
Alloy .0005/ft 1
4 to 4 up to 120
3C or 4C
Ground
HELIX Centralizing
Stainless .0005/ft 1
4 to 4 up to 120
2C or 3C
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 3
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
ThreadTypes Definitions
The acme thread form, established over 100 years ago, Land (Major) Diameter - The outside diameter of
replaced square thread screws, which had straight-sided the screw.
flanks and were difficult to manufacture.
Pitch Diameter - On an acme screw, this diameter is
There are three main classes of acme thread forms: approximately halfway between the land diameter and
general purpose (G), centralizing (C), and stub acme. The the root diameter. It is the diameter at which the thread
General Purpose and Centralizing thread forms have a thickness is equal to the space between threads.
nominal depth of thread of 0.50 pitch and have a 29
included thread angle. Trapezoidal thread forms have a Root (Minor) Diameter - The diameter of the screw
30 included thread angle. HELIX precision lead screw measured at the bottom of the thread.
assemblies have a 40 angle.
Pitch - The axial distance between threads. Pitch is equal
Compared to general-purpose thread forms, centralizing to the lead in a single start screw.
threads are manufactured with tighter tolerances and
reduced clearance on the major diameter. Lead - The axial distance the nut advances in one
revolution of the screw. The lead is equal to the pitch
Normally Loaded Nut Side Loaded Conventional
NormallySingle
Loaded (Single
Nut Flank) Side Loaded
G Class NutConventional times the number of starts.
Flank
Single
ContactFlank)
(Single G Class Nut Direction
Double of Load
Clearance
Contact Direction
Contact Flank Double
Contact
Flank
Clearance of Load Clearance
Flank Contact
Direction
of Load
Direction
Contact NUT
NUT
NUT Clearance
PITCH STARTS = LEAD
NUT
of Load
4
Screw Starts - The number of independent threads on
the screw shaft; example one, two or four.
Single Start (Lead = Pitch) Double Start (Lead = 2 Pitch) Four Start (Lead = 4 Pitch)
Lead Lead
Pitch and Lead Pitch Pitch
Land
Dia. Root
Dia.
Single Start (Lead = Pitch) Double Start (Lead = 2 x Pitch) Four Start (Lead = 4 x Pitch)
Matched Lead - When multiple screws are used in Life - HELIX precision lead screws are manufactured
unison to move a load with precise synchronicity, screws from high quality materials with excellent dynamic
of similar lead accuracy can be factory selected and properties. Because of the variable effects of friction,
supplied as sets. Consult factory for matched lead set lubrication and cleanliness, a specific life cannot be
tolerances. predicted. Proper lubrication, regular maintenance, and
operation within specified limits will extend the life of
Straightness - Although HELIX precision lead screws lead screws.
are manufactured from straight, cylindrical material,
internal stresses may cause the material to bend or yield. Efficiency - Efficiency of HELIX precision lead screw
assemblies range from 15% to 85%. These efficiencies are
When ordering random lengths or cut material without dependent upon nut material, lubrication, lead and thread
end machining, straightening is recommended. Handling form. The efficiencies for each assembly are listed on the
or machining of screws can also cause the material to bend following pages.
or yield. Before, during and after machining, additional
straightening is required. When ordering screws with Backdriving - Normally, lead screws are used to convert
machined ends from HELIX Linear Technologies, the rotary motion into linear motion. Backdriving is the result
following straightness tolerances can be expected: of the load pushing axially on the screw or nut to create
rotary motion.
HELIX precision rolled and milled lead screws are
straight within 0.010 inch/foot and will not exceed 0.030 Generally, a nut with efficiency greater than 50% will
inch in any 6-foot section when shipped from the factory. have a tendency to backdrive. If a selflocking assembly is
required, select a nut with efficiency below 35%.
HELIX precision ground lead screws are straight within
0.001 inch/foot when shipped from the factory. If tighter CAUTION: Vibration can cause any lead screw assembly to
straightness tolerances are required, contact HELIX creep or backdrive. When using lead screws, applications
customer service. should be analyzed to determine the necessity of a brake,
especially when the possibility of injury may occur.
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 5
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Standard
FORCENut Tension Load - A load that tends to stretch the screw.
Nut A FORCE Nut B
Compression Load - A load that tends to squeeze the
screw.
FORCE
FORCE
Leadscrew
FORCE
Leadscrew
Load Load Load Load
FORCE FORCE
FORCE FORCE
Nut A Nut B
FORCE FORCE
Compression Load Tension Load
FORCE Leadscrew FORCE
Nut A
Compression Anti-BacklashNut
Nut B
Thrust Load - A load parallel to and concentric with the
FORCE FORCE axis of the screw.
FORCE FORCE
Leadscrew Overturning Load - A load that tends to rotate the nut
Nut A Nut B radially around the longitudinal axis of the screw.
THRUST LOAD
SIDE LOAD
6
End Machining / Mounting Definitions
EZZE-MOUNT- EZZE-MOUNT bearing blocks contain End Fixity - End fixity refers to the method by which
precision anti-friction bearings and are designed to the ends of the screw are supported. The degree of end
be used with both acme ball screws and lead screws. fixity is related to the amount of restraint of the ends of
Single and double bearing base mount and flange mount the screw.
versions of EZZE-MOUNT bearing blocks are available.
The three basic types of end fixity are:
Standard Ends - For each screw size, HELIX has
designed a family of standard machined ends applicable Free No support
to a variety of bearing arrangements.
Simple Shaft restrained against radial and/or
The use of standard machined end designs offer quick axial loads
deliveries. See page 26-27 for details. Fixed Shaft rigidly restrained against radial,
axial and moment loads
Land Diameter - Land diameter is the outside diameter
of the screw. The difference between the land diameter See page 10 for a more detailed definition of end fixity.
and the bearing journal is the resulting bearing shoulder.
Locknut Threads - Locknut threads are machined to
Root Diameter - The diameter of the screw measured allow the bearing retention on the screw shaft by means
at the bottom of the thread. This diameter is used for of a locknut. The thread used on standard machined ends
determining journal sizes. If the bearing journal diameter follows American National Form NS Class 3. Precision
is larger than the root diameter, thread tracings may be ground locknuts are available on special order.
visible. Generally, these tracings do not have an effect on
bearing performance. Undercuts and Radii - Whenever a shaft changes
diameter, an undercut or a radius is machined into the
Journal - A smooth diameter machined on the end transition to minimize stress concentration. Undercuts
of the screw used as a mounting surface for bearings, are preferred for bearing shoulders because they allow
couplings, pulleys, gears, etc. clearance for the corner of the bearing.
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 7
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Design Considerations
Mounting and Pinning of Flanges Torque
The preferred method of locking a flange to a nut is a pin The required motor torque to drive a lead screw assembly
or set screw parallel to the screw which intersects the is the sum of three components: inertial torque, drag
flange/nut mounting thread. Because of the dissimilarity torque and torque-to-move load. It must be noted that this
of materials, the hole may need to be milled, not drilled. is the torque necessary to drive the lead screw assembly
alone. Additional torque when driving frictional bearings,
Alternatively, the flange may be drilled and tapped
motor shafts, moving components and drag due to
radially for a set screw. After assembly of the flange to
general assembly misalignment must also be considered.
the nut, spot drill the nut threads through the flange and
install a dog point set screw from the flange O.D. into Inertial Torque
the nut O.D. threads. Avoid getting metal chips in the nut
when drilling. Tj = I
WHERE:
I = screw inertia
= angular acceleration
Drilled and
Pin or
Set Screw
Tapped with Drag Torque - HELIX anti-backlash assemblies are
Set Screw
typically supplied with drag torque of 1 to 7 oz.-in.
Diameter Description Qty The magnitude of the drag torque is dependent on the
standard factory settings or settings specified by the
.25 to .625 1
8 14 Slotted Spring Pin 1
customer. Generally, the higher the preset force, the
.75 to 1.0 #10 - 24 4 Set Screw
1
1 better the anti-backlash characteristics.
Temperature
With proper lubrication, HELIX Lead screws with bronze
nuts operate efficiently between 15F and 350F, and
plastic nuts between 15F and 175F.
8
Custom Lead screw Assemblies
Custom nuts
At HELIX, we mold and machine a wide array of lead screw
nuts and actuator components from standard polymers
such as PEEK, Torlon, Acetal, Polypropylene, Turcite,
and custom engineered polymers that include PTFE,
PFPE, silicone, carbon fibers, graphite, glass fibers and
molybdenum disulfide. Should cost or design constraints
require a more integrated package; our engineering staff
can help you simplify your design by combining several
different components into a molded nut. Custom Turcite Nuts
Custom Machining
We offer extensive machining services on our lead screws
and nuts. Journals, keyways, flats, centers, snap ring
grooves and counterbores are common dimensions for
us to machine on the ends of lead screws. Simply email
us your sketch, drawing, or 3D model and we will provide
a quotation in 24 hours.
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 9
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
10
Critical Speed Column Strength
Once the load, speed, length and end fixity are identified, When a screw is loaded in compression (see compression
the next factor to consider is the critical speed. The load definition on page 6), its limit of elastic stability can
speed that excites the natural frequency of the screw is be exceeded and the screw will fail through bending
referred to as the critical speed. Resonance at the natural or buckling.
frequency of the screw will occur regardless of the screw
orientation (vertical, horizontal etc.) or if the system is The theoretical formula to calculate the column strength
designed so the nut rotates about the screw. The critical in pounds is:
speed will vary with the diameter, unsupported length, 14.03 106 Fc d4
end fixity and rpm. Since critical speed can also be Pcr =
L2
affected by shaft straightness and assembly alignment,
it is recommended that the maximum speed be limited WHERE:
to 80% of the calculated critical speed. The theoretical Pcr = Maximum Load (lb)
formula to calculate critical speed in rpm is: Fc = End Fixity Factor
0.25 for one end fixed, one end free
N = Cs 4.762 10 d
6
1.00 for both ends supported
L 2.00 for one end fixed, one end simple
4.00 for both ends rigid
WHERE:
d = Root Diameter of Screw (inch)
N = Critical Speed (rpm)
d = Root Diameter of Screw (inch) L = Distance between nut and load carrying
L = Length Between Bearing Supports (inch) bearing (inch)
Cs = 0.36 for one end fixed, one end free
1.00 for both ends simple If the selected screw does not meet compression load
1.47 for one end fixed, one end simple criteria, consider the following options:
2.23 for both ends fixed
a) Change end fixity (e.g. simple to fixed)
If the selected lead screw does not meet critical speed b) Design to use screw in tension
criteria, consider the following options: c) Increase screw diameter
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 11
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
OD
ANTI-BACKLASH NUTS
AAB Series
Flange Mount Style
A
HELIX Engineered Acetal
Zero Backlash Up To Preload Weight
Excellent Lubricity
Low Wear
BCD F
Dynimic
Diameter A Bmin Bmax F OD K BCD Preload Load2 Static
Diameter Code in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) in (mm) Force1 (lb) (lb) Load (lb)
3 16 " 018 45 225
5mm 020 0.563 0.950 1.100 0.188 1.000 0.144 0.750 0.5 - 1.5 50 250
6mm 024 (14.3) (24.1) (27.9) (4.8) (25.4) (3.7) (19.1) 1 - 3.25 70 350
1 4" 025 75 375
5 16 " 031 80 400
8mm 032 0.688 1.210 1.398 0.188 1.125 0.144 0.875 1 - 2.5 82 410
3 8" 037 (17.5) (30.7) (35.5) (4.8) (28.6) (3.7) (22.2) 1.75 - 5.25 85 425
10mm 039 100 500
7 16 " 043 150 750
0.875 1.750 2.000 0.250 1.500 0.203 1.125 1.75 - 4
12mm 047 175 875
(22.2) (44.5) (50.8) (6.4) (38.1) (5.2) (28.6) 3.75 - 9.5
1 2" 050 200 1000
14mm 055 210 1050
9 16 " 056 220 1100
5 8" 062 250 1250
1.125 2.030 2.343 0.250 1.750 0.221 1.438 1.75 - 4
16mm 063 (28.6) (51.6) (59.5) (6.4) (44.5) (5.6) (36.5) 3.75 - 9.5 260 1300
18mm 071 300 1500
3 4" 075 330 1650
20mm 079 370 1850
22mm 087 400 2000
7 8 " 088 400 2000
1.500 2.300 2.675 0.313 2.250 0.257 1.875 3-5
5 16 " 093 (38.1) (58.4) (67.9) (7.9) (57.2) (6.5) (47.6) 5.5 - 10.5 500 2500
24mm 094 500 2500
1" 100 460 2300
1. Range in preload force available from Low Force Spring and High Force Spring, respectively.
2. AAB-Series Nuts are only as axially stiff as the spring force in one direction.
12
THD
ANTI-BACKLASH NUTS
AAB Series
Thread Mount Style
HELIX Engineered Acetal A
HEX B
8mm 032 0.688 1.210 1.398 0.250 0.188 1 - 2.5 122 610
11
16 5
8-18UNF
3 8" (17.5) (30.7) (35.5) (6.4) (4.8) 1.75 - 5.25
037 125 625
10mm 039 145 725
7 16 " 043 200 1000
0.875 1.750 2.000 0.375 0.250 1.75 - 4
12mm 047 1 15
16-16UN 245 1225
(22.2) (44.5) (50.8) (9.5) (6.4) 3.75 - 9.5
1 2 " 050 290 1450
14mm 055 325 1625
9 16 " 056 335 1675
5 8" 062 350 1750
1.125 2.030 2.343 0.375 0.250 3.25 - 6.5
118 1116-16UN
16mm 063 (28.6) (51.6) (59.5) (9.5) (6.4) 6 - 12 360 1775
18mm 071 400 2000
3 4" 075 440 2200
20mm 079 480 2400
22mm 087 530 2650
7 8 " 088 530 2650
1.500 2.300 2.675 0.375 0.313 5.5 - 10.5
1716 138-16UN
15 16 " 093 (38.1) (58.4) (67.9) (9.5) (7.9) 10 - 20 660 3300
24mm 094 660 3300
1" 100 600 3000
1. Range in preload force available from Low Force Spring and High Force Spring, respectively.
2. AAB-Series Nuts are only as axially stiff as the spring force in one direction.
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 13
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
OD OD
BC BC F
(2) "K" Dia (3) "K" Dia
Slots Slots B
(For 012-020 only)
14
GENERAL PURPOSE NUTS THD
NAB Series
Thread Mount Style
HELIX Engineered Acetal A
Excellent Lubricity and Low Friction
Precision Positioning to 0.0002"/inch
H
HEX
B C
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 15
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
* Range in Theoretical Efficiency based on plastic nut and alloy steel screw, unlubricated and lubricated. An increase in
efficiency of 4 to 5 percentage points can be expected with Teflon coated screws.
16
Lead screw Size List (continued)
Precision Rolled to 0.0002"/inch Lead Accuracy
300 Series Stainless Steel Outside Root
Diameter Diameter
Optional PTFE Teflon Coating
* Range in Theoretical Efficiency based on plastic nut and alloy steel screw, unlubricated and lubricated. An increase in
efficiency of 4 to 5 percentage points can be expected with Teflon coated screws.
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 17
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
18
Lead screw Size List (continued)
Precision Rolled to 0.0002"/inch Lead Accuracy
300 Series Stainless Steel Outside Root
Diameter Diameter
Optional PTFE Teflon Coating
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 19
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
20
Miniature Lead Assemblies
Reference Number System
DIAMETER CODE
Example:
025 = 1/4 Diameter
LEAD CODE
Example
062 = 0.0625 Lead
HELIX/MATERIAL
RA
R = Right Hand Thread A= Alloy Steel, Rolled
L = Left Hand Thread B= Alloy Steel, Milled
C= Alloy Steel, Ground
NOTE: S= Stainless Steel, Rolled
Not all threads/materials are T = Stainless Steel, Milled
available for all sizes. U= Stainless Steel, Ground
MODIFIER LIST
F (Optional) = Round Flange (with Thread Mount Style only)
T (Optional) = Teflon coating
S or M Required
ONLINE
S = Standard. no additional description required
M = Modified, additional description required
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 21
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
OAL
LH THREAD SIDE RH THREAD SIDE
**
INCOMPLETE THREAD ** Consult chart for incomplete thread length
22
Miniature TWIN-LEAD ASSEMBLIES
Reference Number System
Diameter Lead First End Second End Left Hand Right Hand Left Hand Right Hand
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 23
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Lubricants Benefits
Sheer Stability
Proper lubrication is the key to continued
High Temperature Resistant
performance and reliability of lead screw
assemblies. Use E-100 spray and PAG-1 Corrosion Protection
grease lubricants to maximize life of your Separation Resistant
acme screw assembly.
Extreme Pressure Properties
Shelf Stable
Water Resistant
OIL VISCOSITY
Nlgi Net
Product Grade Penetration Dropping Gelling CST CST Temp. Contents Total
Name Number (Worked) Point Agent @40C @100C Range Per Unit Part No. Weight
Coating Properties
Thickness 0.4 - 0.8 MIL
Color Black
Tensile Strength (ASTM D1708) 3000-12000 PSI
Hardness (ASTM D2240) 60 HB (Shore D)
Abrasion Resistance (ASTM D4060) Excellent
Adhesion (ASTM D4145) OK (A)
Coefficient of friction (ASTM D1894) 0.15 static
Chemical Resistance (ASTM D543) Excellent
Salt Spray Resistance (ASTM B117-73) >168hr at 5% solution, 35 C (95 F)
Dielectric Strength (ASTM D149) 100 volts per mil
Use Temperature 260 C (500 F) max
Teflon coated HELIX lead screws
24
Machined Ends and Bearing Supports
End Code
Type Universal Mounts Flange Mounts
Nominal
Dia-Lead 1,2,3 4 Double Single Double Single
025-050 3 2
025-250 3 2 Contact HELIX Contact HELIX
025-333 3 2 Sales Engineers for Sales Engineers for
031-250 5 2 custom solutions. custom solutions.
031-500 5 2
037-062 7 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-083 7* 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-100 7 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-125 7 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-166 7* 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-200 7* 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-250 7 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-500 7 4 EZM-1007 EZM-4007 EZF-1007 EZF-4007
037-999 6 4*
050-100 9 6* EZM-1009 EZM-4009 EZF-1009 EZF-4009
050-200 9 6 EZM-1009 EZM-4009 EZF-1009 EZF-4009
050-250 8 4 EZM-1008 EZM-4008 EZF-1008 EZF-4008
050-500 10 6 EZM-3010 EZM-4010 EZF-3010 EZF-4010
050-999 9 6 EZM-1009 EZM-4009 EZF-1009 EZF-4009
062-100 12 8 EZM-3012 EZM-4012 EZF-3012 EZF-4012
062-125 10 6 EZM-3010 EZM-4010 EZF-3010 EZF-4010
062-200 12 6 EZM-3012 EZM-4012 EZF-3012 EZF-4012
062-375 10 6 EZM-3010 EZM-4010 EZF-3010 EZF-4010
075-100 15 8 EZM-3015 EZM-4015 EZF-3015 EZF-4015
075-166 12 8 EZM-3012 EZM-4012 EZF-3012 EZF-4012
075-200 12 8 EZM-3012 EZM-4012 EZF-3012 EZF-4012
075-333 12 8 EZM-3012 EZM-4012 EZF-3012 EZF-4012
075-500 12 8 EZM-3012 EZM-4012 EZF-3012 EZF-4012
087-166 15 10 EZM-3015 EZM-4015 EZF-3015 EZF-4015
100-100 20 12 EZM-2020 EZM-4020 EZF-2020 EZF-4020
100-166 17 10 EZM-3017 EZM-4017 EZF-3017 EZF-4017
100-200 17 10 EZM-3017 EZM-4017 EZF-3017 EZF-4017
100-250 17 10 EZM-3017 EZM-4017 EZF-3017 EZF-4017
100-500 17 10 EZM-3017 EZM-4017 EZF-3017 EZF-4017
100-999 20 12 EZM-2020 EZM-4020 EZF-2020 EZF-4020
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 25
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Specifying standard machined ends results in quicker requirements for either simple or fixed bearing support.
deliveries. The machined ends shown below represent These standard ends may be machined and ground to
designs that are compatible with common application finish size.
A
A A B F C
B F C B F C
D D D
G
G G .016
.016 .016 .032
.032 .032
E
E E
(with4K
Type 4KType keyway)
(with keyway) Type 4NType 4N
Type 4K
4L(with
(without
Type 4LType keyway) keyway)
(without
keyway)
Type 4L (without keyway) Type 4
pe 1N Type 1N Type 2N Type 2N
Type 2N Type 2N Type
Type3N3N Type 3N Type 3N A A B B
Type 1N
B B B B B B B B F F
D D D D D D D D D D D D
G G
016 .016 .016 .016 .016 .016 .016 .016 .016
032 .032 .032 .032 .032 .032 .032 .032 .032
E E E E E E E E
Non-Driven Support End Non-Driven Support End Non-Driven Support End Standard Journal for Pillow Block Standard Journal for
Single Bearing Double Bearing Double Bearing Single Bearing Pillow Block
Double Bearing
End Types
1K, 2K, 3K and 4K are designed with a shaft Double bearing supports use a Type 3N, 3L and 3K.
extension and keyway for square keys. Single bearing supports use Type 1N.
1L, 2L, 3L and 4L are designed with a shaft extension Where standard ends do not satisfy the application
without a keyway. requirements, special ends may be machined to customer
1N, 2N, 3N and 4N are designed to be a non-driven specifications. Please submit a print for a prompt and
support end. competitive quotation.
26
Machined Ends: Drawings and Codes (continued)
TYPE 4 (K, L, N)
Machined Typical Journal for Pillow Block
End Code A B D F G
2 .75 .25 .1251 / .1248 N/A N/A
4 1.38 .50 .2501 / .2498 .063 .63
6 1.50 .75 .3751 / .3748 .125 .75
8 2.63 1.00 .5000 / .4995 .125 1.50
10 2.63 1.25 .6250 / .6245 .188 1.50
12 2.72 1.50 .7500 / .7495 .188 1.50
16 2.84 1.50 1.0000 / .9995 .250 1.50
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 27
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Ref. Nema
Part No. Code Frame Ref. AA BB T U S Y W AK AJ TAP R
EZM-1008-17 U1 17 1.75 0.25 3.35 0.25 0.094 1.75 0.52 .868/.871 1.725 #8-32 0.19
EZM-1009-23 U2 23 2.50 0.19 4.10 0.38 0.125 2.50 0.38 1.503/1.506 2.625 #10-32 0.26
EZM-3010-23 U2 23 2.50 0.19 4.10 0.38 0.125 2.50 0.38 1.503/1.506 2.625 #10-32 0.26
EZM-3012-23 U2 23 2.50 0.19 4.48 0.38 0.125 2.50 0.38 1.503/1.506 2.625 #10-32 0.10
EZM-3012-34 U3 34 3.25 0.16 4.92 0.50 0.125 2.50 0.81 2.878/2.882 3.875 #10-32 0.10
EZM-3015-23 U2 23 2.50 0.19 4.69 0.38 0.125 2.50 0.38 1.503/1.506 2.625 #10-32
EZM-3015-34 U3 34 3.25 0.16 5.13 0.50 0.125 2.50 0.81 2.878/2.882 3.875 #10-32 0.19
EZM-3017-34 U3 34 3.25 0.16 5.56 0.50 0.125 3.12 0.81 2.878/2.882 3.875 #10-32 0.13
EZM-3017-42 U4 42 4.50 0.19 6.31 0.63 0.188 3.12 1.56 2.504/2.508 5.000 1
4"-20 0.13
EZM-2020-34 U3 34 3.44 0.16 5.96 0.50 0.125 3.44 0.81 2.878/2.882 3.875 #10-32 0.10
EZM-2020-42 U4 42 4.50 0.19 6.71 0.63 0.188 3.44 1.56 2.504/2.508 5.000 1
4"-20 0.10
AA Sq. Tap
4 Holes
S on AJ Bolt Circle Dia.
SECTION A-A Keyway
45
Y
U AK
B
R A
G BB
0.020 T
W
A
NOTE:Note:
For For
complete
complete EZZE-MOUNT measurements
EZZE-MOUNT measurements , see chartsee chart
on page 30. on page xxx.
28
EZZE-MOUNT: Flange Mount Bearing Support With Motor Mount
Flange Mount with motor mount includes an EZZE-MOUNT
block with a motor mount for easy, accurate installation
of acme screw assemblies.
Ref. Nema
Part No. Code Frame Ref. AA BB T U S Y W AK AJ TAP
EZF-1008-17 Y1 17 1.75 0.25 2.84 0.25 0.094 2.2 0.52 .868/.871 1.725 #8-32
EZF-1009-23 Y2 23 2.50 0.19 3.41 0.38 0.125 2.1 0.88 1.503/1.506 2.625 #10-32
EZF-3010-23 Y2 23 2.50 0.19 3.41 0.38 0.125 2.1 0.88 1.503/1.506 2.625 #10-32
EZF-3012-23 Y2 23 2.50 0.19 3.70 0.38 0.125 1.81 0.88 1.503/1.506 2.625 #10-32
EZF-3012-34 Y3 34 3.25 0.16 4.14 0.50 0.125 1.81 1.31 2.878/2.882 3.875 #10-32
EZF-3015-23 Y2 23 2.50 0.19 3.84 0.38 0.125 1.98 0.88 1.503/1.506 2.625 #10-32
EZF-3015-34 Y3 34 3.25 0.16 4.61 0.50 0.125 1.98 1.31 2.878/2.882 3.875 #10-32
EZF-3017-34 Y3 34 3.25 0.16 4.62 0.50 0.125 2.25 1.67 2.878/2.882 3.875 #10-32
EZF-3017-42 Y4 42 4.50 0.19 5.37 0.63 0.188 2.25 2.41 2.504/2.508 5.000 1
4"-20
EZF-2020-34 Y3 34 3.44 0.16 4.92 0.50 0.125 2.37 1.67 2.878/2.882 3.875 #10-32
EZF-2020-42 Y4 42 4.50 0.19 5.67 0.63 0.188 2.37 2.41 2.504/2.508 5.000 1
4"-20
SECTION A-A
G
J D Mounting Holes Tap
S Keyway
M on C Bolt Circle Dia, 4 Holes
45 on AJ Bolt
Y
Circle Dia.
~0.020
A
L U AK
BB A
W
T AA Sq.
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 29
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
EZZE-Mount
Universal Mount Single And Double Bearing Support
Universal-Mount Double
Double Angular Contact Bearing - use with Type 3 Standard Ends
Universal
Double
Part No. A B C D E F
SECTION A-A A
P EZM-1007 2.00 1.38 1.50 1.94 0.88 0.25
H C
K EZM-1008 2.00 1.38 1.50 2.00 0.88 0.25
Universal-Mount Single
Single Radial Bearing - use with Type 1 Standard Ends
30
P
L
G H J K Shaft Dia. Thru M Bolt Size Thru CBore P1 Q End Code
1.06 0.50 0.46 0.187 0.186 0.22 0.687 1
4 1 8
3
0.28 0.41 0.41 7
P
L
G H J K Shaft Dia. Thru M Bolt Size Thru CBore P1 Q End Code
1.06 0.50 0.22 0.687 1
4 1 8
3
0.28 0.41 0.41 0.19 7
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 31
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
TM
Ezze-Mount
Flange-Mount Single And Double Bearing Support
Flange-Mount Double
Double Angular Contact Bearing - use with Type 3 Standard Ends
Flanged
E
F Double Counter-
G Part No. A B C D Thru bore
H EZF-1007 1.88 2.44 1.875 0.266 0.44
J D
R 0.03 MAX A EZF-1008 1.88 2.44 1.875 0.266 0.44
0.020 45o
K EZF-1009 2.00 2.60 2.000 0.266 0.44
Flange-Mount Single
Single Radial Bearing - use with Type 1 Standard Ends
Flanged
G Single Counter-
J Part No. A B C D Thru bore
D 1.88 2.44 1.875
Q Ref. EZF-4007 0.266 0.44
R 0.03 MAX 45 o
EZF-4008 1.88 2.44 1.875 0.266 0.44
A
EZF-4009 2.00 2.60 2.000 0.266 0.44
L A
EZF-4010 2.00 2.60 2.000 0.266 0.44
32
E F G H J K Shaft Dia. L M P Q End Code
1.94 1.44 1.06 0.82 0.50 0.187-0.186 1.3775-1.3770 0.188 0.063 7
ONLINE
helixlinear.com
The specifications and data in this publication are believed to be accurate and reliable. However, it is the responsibility of the product user to determine the suitability of 33
Helix Linear Technologies, Inc. products for a specific application. While defective products will be replaced without charge if promptly returned, no liability is assumed beyond such replacement.
Our products make us industry leaders.
Our people make us world class.
Christopher M. Nook
CEO
H E L I X L i n e a r Te c h n o l o g i e s , I n c .
TM
2 3 2 0 0 C o m m e r c e Pa r k R o a d | B e a ch w o o d , O H 4 4 1 2 2 U S A | 1- 8 5 5 - H E L I X LT | w w w . h e l i x l i n e a r. c o m