Abstract
Little information on experimental investigations regarding the influence of the prestressing forces in the shear resistance of prestressed beams is
found in the technical literature. Thus, it was experimentally evaluated the shear resistance of six post-tensioned prestressed concrete beams with
cross section of (150 x 450) mm2, total length of 2400 mm and concretes compressive resistance of 30 MPa, with the variables of this work being
the layout of the prestressing cable, straight or parabolic, and the stirrups geometric rate. Verticals displacement, steel and concretes strains and a
comparison of the experimental loads with the estimates of ACI 318, EUROCODE 2 and NBR 6118: 2014 codes are presented and discussed. The
results showed that the cables parabolic layout increased the beams shear resistance in up to 16% when compared to beams with straight cables.
Resumo
Poucas informaes relativas s investigaes experimentais sobre a colaborao da protenso na capacidade resistente ao esforo cortante
dos elementos estruturais protendidos, so encontradas na literatura tcnica. Assim, foi avaliado experimentalmente o desempenho ao cisalha-
mento de seis vigas de concreto protendido com cordoalhas engraxadas, seo transversal de (150 x 450) mm2, comprimento de 2400 mm e
resistncia compresso do concreto de 30 MPa, sendo que as variveis do trabalho foram o traado do cabo de protenso, reto ou parablico, e
a taxa de armadura transversal. So apresentados os resultados para os deslocamentos verticais, deformao do ao e do concreto e as cargas
ltimas experimentais comparadas com as estimadas das normas ACI 318, EUROCODE 2 e NBR 6118: 2014. Os resultados mostraram que as
vigas com traado inclinado apresentaram aumento na resistncia ao cisalhamento em at 16 % quando comparadas s vigas com cabos retos.
a
Instituto Federal do Amap, Macap, AP, Brasil;
b
Universidade Federal do Par, Faculdade de Engenharia Civil, Belm, PA, Brasil.
Received: 30 Apr 2015 Accepted: 26 Apr 2016 Available Online: 23 Sep 2016
2016 IBRACON
O. A. SOUZA JUNIOR | D. R. C. OLIVEIRA
1. Introduo vertical que depende da fora total do cabo e que reduz o esforo
cortante solicitante. A Figura 1 mostra uma viga de concreto proten-
No dimensionamento das estruturas de concreto armado, a trao dido com uma seo dx e as componentes geradas pela protenso.
por flexo gerada pelo carregamento combatida exclusivamente A protenso tambm induz tenses de compresso que contribuem
pelo ao, retardando a fissurao do concreto. A armadura, cha- para a reduo das tenses principais de trao de modo que as
mada de armadura passiva, destina-se a receber os esforos de fissuras de cisalhamento apresentam menor inclinao. De acordo
trao no absorvidos pelo concreto, trabalhando somente quando com Leonhardte Monnig [2] a inclinao das bielas varia de 15 a
solicitada. Nas estruturas de concreto protendido a fora aplicada 30. Contudo, em trechos com cargas concentradas ou sobre apoios
nos cabos transmitida ao concreto, combatendo as tenses de intermedirios de vigas contnuas, por exemplo, surgem fissuras de
trao por flexo e auxiliando as armaduras passivas. A armadura cisalhamento que, inevitavelmente, atingem 45.
de protenso, chamada de armadura ativa, colocada na pea no Este artigo objetiva avaliar a contribuio da protenso na reduo
somente para comprimir e gerar as tenses de compresso neces- do esforo cortante solicitante em seis vigas, atravs da compo-
srias para que o concreto possa absorver as tenses de trao nente vertical gerada com a inclinao do cabo de protenso, sen-
gerada pelo carregamento, mas tambm para resistir aos carrega- do trs com traado do cabo reto e trs com traado do cabo para-
mentos externos atuantes, oferecendo muitas vantagens, como a blico, e para cada traado de cabo foram utilizadas trs taxas de
reduo do esforo cortante solicitante pela ao da componen- amarduras transversais (estribos verticais), sendo os resultados
te vertical gerada pela protenso, no caso de cabos inclinados, o experimentais paraas cargas ltimas comparados s estimativas
aumento das tenses de compresso e reduo das tenses de das normas ACI 318 [3], EUROCODE 2 [4] e NBR 6118 [5].
trao, reduo de flechas e da fissurao, com a estrutura perma-
necendo praticamente no Estdio I ao longo de sua vida til. 2. Reviso bibliogrfica
Segundo Naaman [1], a protenso longitudinal introduz nas peas
de concreto protendido com cabos inclinados uma componente Algumas pesquisas buscaram entender os parmetros que
l D bf bw fc w s Vu Mu Modo
Vigas a/d Tra.
(mm) (mm) (mm) (mm) (MPa) (%) (mm) (kN) (kN.m) ruptura
B1 72,4 1,61 R 0,17 250 840,2 892 Cisalh.
B2 74,5 1,61 R 0,95 178 1040,8 1106 alma
influenciam na resistncia ao cisalhamento de vigas de concreto Flexo-Cisalhamento (Flexure Shear) e Cisalhamento na Alma (Web
protendido. Laskar e Hsu [6], estudaram o comportamento ao cisa- Shear). As vigas que romperam em cisalhamento na alma apre-
lhamento de cinco vigas de concreto protendido, com 7620 mm de sentaram ruptura frgil, enquanto que as vigas que romperam em
comprimento, fc mdio de 70,5 MPa, seo transversal e altura til flexo-cisalhamento apresentaram ruptura dctil. As vigas com rela-
de 568 mm, tendo como variveis a taxa de armadura transversal, o a/d de 4,29 apresentaram ruptura dctil quando comparadas s
o traado do cabo de protenso e a relao vo altura til (a/d). As vigas com a/d de 1,61, mostrando a forte influncia deste parmetro
vigas B1, B2 e B4 apresentaram traado reto e foram projetadas na resistncia ao cisalhamento de vigas protendidas. As vigas B1 e
para o modo de ruptura por cisalhamento, com relao a/d (1,61), e B2, que apresentaram como variveis apenas a taxa de armadura
as vigas B3 e B5, com traado parablico, tambm com ruptura por transversal, apresentaram ruptura frgil devido baixa relao a/d,
cisalhamento, apresentaram relao a/d (4,29). A taxa de armadura sendo que a resistncia da viga B1 foi 30% maior que da viga B2.
transversal das vigas variou de w = 0,17% para as vigas B1, B4 e MacGREGOR [7] avaliou a influncia do traado do cabo de pro-
B5 e de w = 0,95% para as vigas B2 e B3. A Tabela 1 apresenta os tenso na resistncia ao cisalhamento de vinte e duas vigas de
parmetros de ensaio, alm das cargas ltimas experimentais e os concreto protendido, com ngulo de inclinao medido do centro
modos de ruptura. geomtrico da armadura de protenso, na seo central, at o eixo
Observou-se que as tenses de fissurao foram maiores para as longitudinal da viga, variando de zero a dez graus. A Tabela 2 apre-
B1 e B2, com traado do cabo reto, quando comparadas com as senta as caractersticas das vigas ensaiadas por MacGREGOR [7].
vigas com traado parablico, B3 e B5, devido a componente ho- O comportamento das vigas aps a formao da fissura inicial (es-
rizontal dos cabos. As vigas com traado parablico se mostraram tado de descompresso), foi alterado de acordo com a inclinao
mais eficientes em relao as vigas com traado reto no combate dos cabos. Para vigas com maiores inclinaes dos cabos ocorreu
ao esforo cortante reduzindo em torno de 10% o cortante solicitan- um ganho mdio de resistncia de 25%, da formao da primei-
te das vigas em relao as vigas com traado reto. Os resultados ra fissura at a ruptura, quando comparada com as demais vigas
experimentais mostraram tambm que as vigas apresentaram dois de menores inclinaes. Para as vigas com menores inclinaes
modos de ruptura, segundo a norma norte americana ACI 318/2011: no houve aumento significativo de carga, da formao da primeira
fc bf bw d p
Vigas N cabos
(MPa) (mm) (mm) (mm) (MPa) (Grau)
AD.14.37 22.5 152 742 6.45 11
B.14.34 18.2 805 0.00 12
B.14.41 20.0 805 0.00 12
BD.14.18 43.0 861 2.70 13
BD.14.19 43.0 784 5.00 12
BD.14.23 26.6 693 10.00 11
BD.14.26 24.0 812 10.00 11
BD.14.27 24.0 777 2.22 11
BD.14.28 23.0 826 1.53 11
BD.24.32 18.6 80 770 1.88 11
BD.14.34 18.0 770 6.28 11
152 254
BD.14.35 20.0 770 2.38 11
BD.14.42 26.0 567 6.45 11
BV.14.30 28.0 861 3.25 11
BV.14.32 26.0 784 3.25 12
BV.14.34 25.0 868 2.70 12
BV.14.35 23.5 805 5.36 12
BV.14.42 20.0 840 6.80 13
CD.13.23 26.5 840 0.00 12
CD.13.24 25.0 784 3.40 12
45
CD.13.25 24.0 826 2.85 12
CD.14.34 17.5 735 1.88 11
A capacidade resistente ao cisalhamento de uma viga de concreto Segundo o ACI 318 [3], a resistncia ao cisalhamento de vigas de
protendido pode ser dividida em duas parcelas, uma resistida pelo concreto protendido baseada no modelo de analogia de trelia
concreto e seus mecanismos auxiliares descritos a diante, e outra modificada, onde Vn resistncia nominal ao cisalhamento, obe-
resistida pela armadura transversal. Uma viga, mesmo sem arma- decendo a condio de ser maior que o esforo cortante de clculo
dura transversal apresenta capacidade de resistir a uma determi- na seo considerada Vu ,sendo apresentada nas equaes 1 e 2.
nada fora cortante. A Figura 2 mostra as vrias componentes dos
mecanismos de resistncia ao cisalhamento de vigas sem arma-
dura transversal, exceto a componente relativa ao efeito de arco,
segundo o ACI-ASCE Comittee 426 [8].
fVn Vu (1)
Para estruturas de concreto armado submetidas a foras cortantes,
a parcela de resistncia devida ao concreto a soma de diversos
esquemas capazes de transmitir esforos entre as sees como o
efeito do concreto no fissurado (cantilever action), sendo que este
mecanismo ocorre em trechos no fissurados da viga (entre duas
fissuras consecutivas) ou em partes no fissuradas de elementos
Vn = f nVc + f nVs (2)
fissurados (zona de compresso de uma seo fissurada); o en-
Onde:
: fator de reduo: 0,75;
Figura 3 Padro de fissurao para vigas Vc: parcela proveniente do concreto;
de concreto armado (ACI 318[3]) Vs: parcela proveniente da armadura transversal.
O clculo da parcela Vc baseado no padro de fissurao mos-
trado na Figura 3, onde o esforo Vci responsvel pelo surgi-
mento de fissuras de flexo e o esforo Vcw pelo surgimento das
fissuras de cisalhamento na alma, sendo calculados segundo as
equaes 3 e 4. O valor da parcela Vc ser o menor entre os dois.
V n Mcre
Vci = 0.05nl n f c nbw nd p + Vd + i >
M max
(3)
(0.14n f c nbw nd )
( )
Vcw = 0.29nl n f c + 0.3nf pc nbw nd + V p (4) da armadura de protenso at a fibra mais comprimida, em mm;
Asw: a rea da seo transversal da armadura de cisalhamento;
s: espaamento dos estribos;
z:brao de alavanca, 0.9 d, com d em mm;
Onde: fywd: tenso de escoamento de clculo da armadura de cisalha-
: fator de modificao das propriedades mecnicas do concreto, mento;
igual a 1; v: 0,5 para MPa e 0,6 para MPa, desde que a tenso na armadura
fc: resistncia compresso do concreto; de cisalhamento seja menor ou igual a 80% da tenso de escoa-
bw:largura do elemento; mento caracterstica.
dp: distncia da fibra extrema mais comprimida ao centro de gravi-
dade da armadura de protenso, mas no menor que 0,8h; 2.4 NBR 6118
Vd: cortante na seo considerada devido ao peso prprio;
Vi: cortante na seo considerada devido ao carregamento exter- A NBR 6118 [5] apresenta dois modelos de clculo baseados na
no ocorrendo simultaneamente com Mmax; analogia em modelo de trelia, de banzos paralelos, associados
Mmax: momento mximo na seo devido ao carregamento; a mecanismos resistentes complementares desenvolvidos no in-
Mcre: momento que gera fissuras de flexo na seo devido ao terior do elemento estrutural e traduzidos por um a componente
carregamento; adicional Vc. O modelo I, considera a verificao da diagonal com-
fpc: tenso de compresso do concreto, no centroide da seo primida VRd2 (Equao 8) e da diagonal tracionada VRd3 (Equao
transversal, que resiste ao carregamento externo; 9). A inclinao da biela de =45 em relao ao eixo longitudinal
Vp: componente vertical da fora de protenso. do elemento estrutural.
2.3 EUROCODE 2
O EUROCODE 2 [4] especifica dois mtodos de clculo para a VRd 2= 0.27navnfcdnbwnd (8)
resistncia ao cisalhamento como funo da presena ou no de
armadura transversal. Para elementos sem armadura de cisalha-
mento (Equao 5) a resistncia expressa em termos de Vc.
Para elementos com armadura de cisalhamento, a resistncia o
maior valor entre VRds eVRd,max, apresentados nas Equaes 6 e 7.
VRd 3 = Vc +Vsw (9)
1
VRd ,c = CRd ,c nk n (100nrl nfck )3 + k1 ns cp nbwnd (5) Onde:.
v = (1-fck/250);
Vsw = (Asw/s)0,9dfywd(sen + cos );
Vc= 0 nos elementos estruturais tracionados quando a linha neutra
se situa fora da seo;
Asw
V Rd , s =
s
nz nf ywd ncot q (6) Vc = Vc0 na flexo simples e na flexo-trao com a linha neutra
cortando a seo;
Vc = Vc0(1+ M0/ MSd,mx) 2 Vc0 na flexo-compresso;
Vc0= 0,6fctdbw d
fctd= fctk,inf/c
O modelo II, tambm considera a verificao da diagonal compri-
acwnbwnznnnfcd
VRd,max =
cotg q + tg q
(7) mida VRd2 (Equao 10) e da diagonal tracionada VRd3 (Equao
11). Neste caso, a inclinao da biela varia entre 30 e 45.
Onde:
VRd,c: resistncia ao cisalhamento de clculo de elementos sem
VRd 2 = 0,54na v 2 nf cd nbwnd n sin 2 q (cot a + cot q ) (10)
armadura de cisalhamento;
VRd,s: parcela proveniente da armadura transversal;
VRd,max: valor mximo limite do esmagamento da diagonal compri-
mida;
CRd,c: fator com valor recomendado de (0,18/c);
, com d em mm;
VRd 3 = Vc + Vsw (11)
l: taxa de armadura longitudinal;
k1: fator com valor recomendado de 0,15;
d ep As Ap cs cp fck Es Ep
Viga Tr
(mm) (mm) (mm) (mm) (mm) (mm) (MPa) (GPa) (GPa) (Grau)
VCPR-0 0 R
VCPP-0 16 P
VCPR-250 0 R
361 180 942 101 20 45 30 210 195
VCPP-250 16 P
VCPR-150 0 R
VCPP-150 16 P
dp altura til da viga; ep excentricidade do cabo de protenso no meio do vo; cs cobrimento do cabo de protensono meio do vo; R traado do cabo reto;
P traado do cabo parablico; inclinao do cabo de protenso
Os valores mdios das tenses de escoamento e de ruptura, da Fora mxima de protenso (kN) 150,0
deformao de escoamento e do mdulo de elasticidade das seis Fora na ancoragem (kN) 131,0
amostras de barras de ao com dimetro 20,0 mm e 5,0 mm das
armaduras de flexo e transversal, respectivamente, so apre-
CIA Siderrgica Belgo Mineira e so apresentados na Tabela 6.
sentados na Tabela 5. Adicionalmente, todas as amostras aten-
deram aos critrios de ductilidade da NBR 7480 [12], que admite
que a tenso de ruptura fu do ao utilizado seja, no mnimo, igual 3.4 Execuo das vigas
a 1,10 fys. Os dados das propriedades mecnicas das monocor-
doalhas engraxadas foram obtidos do catlogo da fabricante Aps a confeco das frmas de madeira e aplicao de
desmoldante, as armaduras passivas e ativas receberam espaa- 50 mm do ponto central do cabo ao fundo das vigas. As vigas
dores e foram posicionadas cuidadosamente visando a padroni- e os corpos-de-prova foram ento concretados simultaneamen-
zao dos cobrimentos das armaduras e, consequentemente, das te utilizando-se o mesmo concreto, da mesma betonada, sendo
alturas teis das vigas. Tanto para as vigas com cabo reto quanto lanado e adensado com vibradores de imerso com dimetro da
para as vigas com cabo parablico foi adotado um cobrimento de agulha de 32 mm para as vigas e 25 mm para os corpos-de-prova
e, aps 4 horas, iniciou-se o processo de cura com sacos de ania- 3.6 Sistema de ensaio
gem umedecidos, tanto das vigas quanto dos corpos-de-prova. A
desforma aconteceu 7 dias aps a concretagem. A Figura 5 mos- O ensaio das vigas foi realizado no Laboratrio de Engenharia
tra o processo executivo das vigas. Civil da Universidade Federal do Par. O primeiro passo foi mon-
tar o sistema de ensaio de quatro pontos (ensaio de Stuttgart),
3.5 Instrumentao posicionando as vigas em apoios de primeiro e segundo gnero
montados em blocos de concreto, que por sua vez foram apoiados
Para monitoramento do comportamento das vigas ao longo sobre a laje de reao do laboratrio. Em seguida o sistema de
do ensaio, foram utilizados extensmetros eltricos de resis- aquisio de dados, ALMEMO 5690-2M, da Ahlborn, compatvel
tncia no concreto e nas armaduras de flexo e transversal. com o software AMR WinControl, foi conectado a todos os exten-
Foram utilizados 28 extensmetros eltricos no ao, incluindo smetros da viga, seguido da montagem do macaco e da clula
armadura passiva e transversal, 06 extensmetros eltricos de carga no prtico de reao e na ancoragem passiva da viga.
no concreto e 06 extensmetrosno porta estribo, totalizando O ensaio inicia com a trao do cabo. A protenso foi realizada por
40 extensmetros, alm de 01 deflectmetro por viga, para meio de um macaco hidrulico monocordoalha com capacidade
a observao da evoluo das flechas geradas pela proten- de 200 kN, em incrementos de 10 kN at atingir a fora final de
so e pelo carregamento. A Figura 6 mostra a instrumentao 120 kN, aps todas as perdas. Inicialmente o cabo foi tracionado
das vigas. at 150 kN, j prevendo as perdas devido ao tamanho reduzido
Figura 9 Deformaes na
Figura 8 Deformaes no concreto
armadura passiva
Os cabos que mais apresentaram variaes nas foras de pro- 4.3 Deformaes da armadura longitudinal
tenso foram os cabos com perfil parablico (vigas VCPP-0 ,
VCPP-250 e VCPP-150) devido aos desvios no cabo, com perda No houve escoamento da armadura passiva de flexo em nenhuma
imediata mdia de 41,4 %, sendo maior que os cabos com perfil das seis vigas, apesar das elevadas cargas de ruptura das vigas. Isso
reto (VCPR-0, VCPR-250 e VCPR-150), que apresentaram perdas se deve a contribuio da armadura ativa na resistncia flexo das
imediatas mdias na ordem de 29,9 %. As perdas chegaram a vigas, visto que o ao das cordoalhas so aos especiais com valor
este valor devido ao tamanho reduzido das vigas, a elevada fora de resistncia trao de 187 kN. As maiores deformaes de trao
no cabo e o mtodo manual de cravao da cunha (acomodao nas barras de armadura passiva dispostas na direo longitudinal na
da cunha). O tamanho reduzido e a elevada trao no cabo fez seo do meio do vo foram de 1,8, 1,94, 2,2, 2,1, 2,34,
com que o esforo nas ancoragens ficasse muito elevado necessi- 2,48, para as vigas VCPR- 0, VCPP- 0, VCPR- 250, VCPP- 250
tando de um maior trabalho das cunhas, aumentando sua acomo- VCPR- 150, VCPP- 150, respectivamente. A Figura 9 mostra o dia-
dao. Na reprotenso o valor mdio das perdas ficou entre 23% grama carga x deformao para as armaduras de flexo.
4.4 Deformaes da armadura transversal isso monitorados, sendo assim monitoras apenas as vigas VCPR
250, VCPP - 250, VCPR - 150 e VCPP 150. A Figura 10 mostra
importante reforar que as vigas VCPR 0 e VCPP 0 apre- as curvas carga x deformao para as armaduras transversais.
sentaram armadura transversal apenas no apoio e pontos de Em todas as vigas no foram verficiadas deformaes maiores
aplicao de carga para evitar ruptura localizado, no sendo por que a de escoamento de ys=4,6 . Os estribos mais solicitados
foram os estribos mais prximos ao carregamento, indicando que obtidos segundo as normas ACI 318[3], EUROCODE 2 [4] e NBR
a trajetria de tenses ocorreu em um fluxo de inclinao menor 6118 [5] e os resultados experimentais obtidos nos ensaios das
de acordo com Leonhardt e Monnig [2], a protenso longitudinal seis vigas protendidas, e a Tabela 10 apresenta a relao entre
introduz nas peas de concreto armado tenses de compresso a carga ltima experimental (PU) e a carga ltima estimada (PE).
que contribuem para a reduo das tenses de trao (que ficam O mtodo do ACI 318 [3] baseado na mdia das tenses de
mais inclinadas com relao ao eixo da pea), de modo que as cisalhamento e na profundidade total da seo transversal bw.d. A
fissuras de cisalhamento configuram-se com menor inclinao, fi- parcela Vc na protenso, deve ser o menor valor entre Vci e Vcw que
cando a inclinao das bielas reduzidas valores entre 15 e 30. so, respectivamente, runa por flexo-cisalhamento (ACI FS) e ru-
na por cisalhamento na alma (ACI WS). Alm da contribuio do
4.5 Deslocamentos verticais concreto, tambm levado em considerao a parcela referente
armadura de cisalhamento Vs. Para as vigas com cabo reto (VCPR
Os deslocamentos verticais das vigas protendidas foram medidos 0, VCPR 250 e VCPR 150), os resultados da estimativa para
por meio de deflectmetros localizados na parte inferior da viga, o mtodo ACI FS, apresentaram relao Pu/PEigual a 1,08, 1,01,
no centro do vo, e so mostrados na Figura 11. A reduo das 1,04, e para as vigas com traado parablico (VCPP 0 VCPP
flechas foi, tambm, obtida com a contra flecha gerada pela ex- 250 e VCPP 150), com relao PU/PE igual a 0,91, a 0, 92 e 0,98,
centricidade da fora de protenso. No ato da protenso, foram respectivamente. O mtodo no considera, diretamente, a con-
medidas contra flechas mximas de valores -0,32 mm, -0,20 mm, tribuio da componente horizontal Vp. A protenso levada em
-0, 35 mm, -0, 43 mm, -0, 32 mm, -0, 37 mm, para as vigas VCPR- considerao por meio de um momento que anula o momento soli-
0, VCPP-0, VCPR-250, VCPP-250 VCPR-150, VCPP-150. citante de clculo, que depende da excentricidade do cabo de pro-
tenso em relao linha neutra. J o mtodo baseado no modo
4.6 Cargas ltimas e modos de ruptura
de ruptura por cisalhamento na alma (ACI WS), o efeito favorvel na alma (ACI WS), pode estar associadas impreciso terica e/
da componente vertical levado em considerao na equao. ou experimental na considerao da inclinao da biela (30) e
Por este mtodo, as vigas com traado reto apresentaram relao da componente vertical da protenso, respectivamente. Entretan-
Pu/PE igual a 0,72, 0,74, 0,92, e as vigas com traado parablico to, estas normas recomendam que sejam adotados os menores
apresentaram relao Pu/PE igual a 0,84 0,86, 0,79. Como o ACI valores, resultando que as suas estimativas foram precisas, ou
recomenda que seja adotado o menor valor entre Vci e Vcw, para a seja, o Modelo I da NBR 6118 e as consideraes para o flexo-
parcela do concreto na resistncia ao cisalhamento, em todas as -cisalhamento da ACI (ACI FS).
vigas o valor usado foi o Vci.
O procedimento do EUROCODE 2 [4] considera vigas com arma- 6. Concluses
dura de cisalhamento, onde a resistncia baseada no modelo
de trelia, com variao do ngulo de inclinao da biela, e vigas Vrios aspectos do desenvolvimento do sistema protendido foram
sem armadura de cisalhamento, somente com a contribuio do discutidos neste artigo, como a contribuio da protensoe do tra-
concreto. Para as vigas com armadura de cisalhamento a norma ado do cabo na resistncia ao cisalhamento de vigas, a influncia
europeia define a resistncia como sendo o menor valor entre a da protenso na reduo de flechas e fissuras, as deformaes
parcela proveniente da armadura, VRds e o valor mximo limite do das armaduras transversais, longitudinais e no concreto alm de
esmagamento da diagonal comprimida, VRd,max, sem a contribui- comparaes dos resultados experimentais com os resultados es-
o do concreto na resistncia. Para elementos sem armadura de timados pelas normas ACI 318 [3], EUROCODE 2 [4] e da NBR
cisalhamento, a protenso considerada por meio da tenso de- 6118 [5]. Para os resultados experimentais apresentados possvel
vido a protensocp. A relao PU/PE para as vigas com cabo reto concluir que o traado parablico do cabo elevou em at 16% a
(VCPR -0, VCPR -250, VCPR -150), foi de 1,07, 2,09 e 1,51, res- resistncia ao cisalhamento das vigas, com ou sem estribos. J as
pectivamente, e para as vigas com traado parablico (VCPP -0, estimativas normativas divergiram entre si com alguns resultados
VCPP -250, VCPP -150), a relao PU/PE foi de 0,91, 1,55 e 1,31. contra a segurana, mas ainda prximos e coerentes com os resul-
A NBR 6118 [5] considera duas formulaes de clculo baseado tados experimentais obtidos nesta pesquisa, exceto os resultados
no modelo de trelia e no esgotamento das diagonais tracionadas do EUROCODE 2 para as vigas com estribos, onde as estimativas
e comprimidas. O Modelo I considera a inclinao da biela de 45 e foram demaisadamente conservadoras. Ressalta-se a necessidade
inclinao dos estribos entre 45 e 90. O Modelo II considera a in- de mais experimentos e anlises criteriosas (computacional, banco
clinao da biela variando entre 30 e 45 e a mesma variao da de dados, etc.) para viabilizar o melhor entendimento do problema e
inclinao dos estribos para o modelo I. O efeito favorvel da pro- uma avaliao mais justa das estimativas normativas.
tenso levado em considerao na relao entre o momento fletor
que anula as tenses normais de compresso na borda da seo 7. Agradecimentos
(M0), e o momento fletor de clculo, mximo no trecho em anlise,
que pode ser tomado como o maior valor do semitramo conside- Os autores agradecem ao CNPq, IPEAM e CAPES pelo apoio
rado. A relao PU/PE, para o modelo I, nas vigas com cabo reto financeiro em todas as etapas desta pesquisa.
(VCPR -0, VCPR -250, VCPR -150), foi de 1,10, 1,05 e 1,09, res-
pectivamente, e para as vigas com traado parablico (VCPP -0, 8. Referncias bibliogrficas
VCPP -250, VCPP -150), a relao PU/PE foi de 0,93, 0,95 e 1,02,
respectivamente. Para o modelo II, nas vigas com traado reto, a [1] NAAMAN, A. E. Prestressed Concrete. Analysis and Design:
relao PU/PE foi de 1,10, 0,89 e 086, e para as vigas com traado Fundamentals. 2 Edio, 2004.
parablico, a relao PU/PE foi de 0,93, 0,83e 0,84. [2] LEONHARDT, F., MONNIG, E. Construes de concreto
A tendncia contra a segurana das estimativas das normas NBR Vol. 3, princpios bsicos sobre armao de estruturas de
6118 e ACI, ou seja, empregando o Modelo II da NBR 6118 e a concreto armado. So Paulo SP. Intercincia Ltda., 1977,
equao da ACI que considera a predominncia do cisalhamento impresso 2007.