Anda di halaman 1dari 12

The Worlds Most Complete

Line of Medium Voltage


Vacuum Circuit Breakers

CIRCUIT BREAKERS
MEDIUM VOLTAGE VACUUM
Type VCP-W Vacuum Circuit Breakers The leading value-added modular
approach for assembling metal-clad
ANSI 5/15 kV at 1200-3000 Amperes switchgear featuring Cutler-Hammer
250-1500 MVA, 60-95 kV BIL medium voltage vacuum circuit
IEC 3.6/17.5 kV at 630-2000 Amperes breakers, structures and accessories.
25-40 kA, 40-95 kV BIL

OEM
SWITCHGEAR
COMPONENT
PRODUCTS

Breaker Type Voltage Class Insulation BIL Interrupting Ratings Continuous Current Application

VCPW-ND ANSI 5 kV 60 kV 250 MVA 1200A 26" Wide New Metal-Clad Switchgear
or Upgrades to Existing Airbreak Switchgear
IEC 3.6-7.2 kV 40-60 kV 25-31.5 kA 630-1250A
VCP-W ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A 36" Wide New Metal-Clad Switchgear
or Upgrades to Existing Switchgear
IEC 3.6-17.5 kV 40-95 kV 25-40 kA 630-2000A
VCPW-SE ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A 36" Wide Special Environment Metal-Clad
Switchgear Featuring Breakers with Cycloaliphatic
IEC 3.6-17.5 kV 40-95 kV 25-40 kA 630-2000A Epoxy Insulation for Harsh Industrial Environments
VCP-W ANSI 27 kV 125 kV 16-40 kA 600-2000A 36" Wide Metal-Clad Switchgear
or Upgrades to Existing Switchgear
IEC 24 kV 125 kV 16-25 kA 630-2000A
VCP-W ANSI 38 kV 170 kV 16-40 kA, 600-2500A 42" Wide Metal-Clad Switchgear
1500 MVA
VCP-W (Outdoor) ANSI 15.5 kV 110 kV 16-31.5 kA 600-1200A Outdoor Station Distribution Breakers
W-VAC IEC 3.6-17.5 kV 40-95 kV 16-40 kA 630-2000A 600-750 mm Wide IEC Medium Voltage Switchgear
W-VAC IEC 3.6-17.5 kV 40-95 kV 31.5-50 kA 2500-3150A 1000 mm Wide IEC Medium Voltage Switchgear
W-VAC IEC 36 kV 170 kV 16-31.5 kA 630-2000A 42" Wide IEC Metal-Clad Switchgear
DHP-VR ANSI 5-15 kV 60-95 kV 250-1000 MVA 1200-3000A DHP Metal-Clad Switchgear Technology Upgrades
with the DHP-VR Direct Roll-in Vacuum Replace-
ment Breakers from the Original Manufacturer
VCP-WR ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A Modular Fixed Vacuum Circuit Breakers in 18", 20",
Series 18, 20, and 29 and 29" Widths for Conversions/Retrofits, Metal
Enclosed Switchgear and Mining Switchgear
VCP-WC ANSI 5-17.5kV 95kV 25-63kA 1200-3000A 36" wide Metal-Clad Switchgear
VCP-WG ANSI 5-15kV 95kV 50-63kA 1200-3000A 36" wide Metal-Clad Switchgear
VCP-T ANSI 5-15kV 95kV 16-25kA 800-1200A Smaller frame breaker
VCP-TR IEC 3.6-17.5kV 95kV 16-25kA 630-1250A Smaller frame breaker

Eaton Corporation 2003 EATON CORPORATION


Cutler-Hammer business unit
1000 Cherrington Parkway ALL RIGHTS RESERVED
Moon Township, PA 15108 PRINTED IN USA
United States
FORM NO. BR01301006E
tel: 1-800-525-2000
www.cutler-hammer.com SEPTEMBER 2003
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
The Industry Leader 5/15 kV Medium Voltage Breaker
in Vacuum Circuit Breakers Rating Chart

VacClad-W, the Cutler-Hammer vacuum The OEM Value-Added Approach to Circuit Protection ANSI Standards Type VCP-W Vacuum Circuit Breaker Rated on Symmetrical Current Rating Basis
switchgear family, has been engineered Identification Rated Values Weight
to feature a standardized design, inter-
Flexibility that Exceeds the Customers Requirements Circuit Nominal Nominal Voltage Insulation Level Current Interrupting Permissible Maximum Current Values
Breaker Voltage 3-Phase Time Tripping Voltage
changeable parts, slot and tab construction, Type Class MVA Maximum Voltage
Voltage Range
Withstand
Test Voltage
Continuous
Current
Short
Circuit
Delay Divided Maximum Closing and
Symmetrical Latching
Closing and
Latching
and industry-leading vacuum interrupter Type VCP-W Vacuum Circuit Breakers Class
Factor at 60 Hz Current
by K
Interrupting Capability Capability
(at Rated Capability Momentary
technology. This world class switchgear Industry Leading Vacuum Technology Power Impulse
Maximum kV)
K Times 2.7 K 1.6 K
includes the Type VCP-W Vacuum Circuit in ANSI 5/15 kV or IEC 3.6/17.5 kV Frequency Rated Short Times Rated Times Rated
Breaker which meets both ANSI and IEC Type VCP-W.
(1 Minute) Circuit Short Circuit Short Circuit
Current Current Current
electrical standards.
Type VCPW-SE.
E K I Y E/K
Type VCPW-ND. kV MVA kV rms kV rms kV Peak Amperes kA rms Cycles Seconds kV rms kA rms kA Peak kA rms lbs.
Industry-Leading Vacuum Technology
50VCPW-ND250 4.16 250 4.76 1.24 19 60 1200 29 5 2 3.85 36 97 58 345
Provides Unequaled Reliability 50VCP-W250 4.16 250 4.76 1.24 19 60 1200 29 5 2 3.85 36 97 58 350
2000 132 78 410
Cutler-Hammer now provides the industrys 3000 525
most complete family of technologically Power Modules 50VCP-W350 4.16 350 4.76 1.19 19 60 1200 41 5 2 4.00 49 132 78 460
advanced vacuum circuit breakers at 5 kV, 2000 490
Complete Structures 3000 525
15 kV, 27 kV, and 38 kV. Type VCP-W Including Fully Equipped Breaker 75VCP-W500 7.2 500 8.25 1.25 36 95 1200 33 5 2 6.60 41 111 66 375
Vacuum Circuit Breakers incorporate many Compartment and Auxiliary Provisions 2000 410
3000 525
design features which have been field
150VCP-W500 13.8 500 15.00 1.30 36 95 1200 18 5 2 11.50 23 62 37 350
proven with more than 25 years of vacuum 2000 97 58 410
interrupter design and manufacturing 3000 525
experiencecoupled with over 70 years 150VCP-W750 13.8 750 15.00 1.30 36 95 1200 28 5 2 11.50 36 97 58 350
2000 130 77 410
of power circuit breaker design and manu- 3000 525
facturing experience. 150VCP-W1000 13.8 1000 15.00 1.30 36 95 1200 37 5 2 11.50 48 130 77 460
2000 490
Type VCP-W Vacuum Circuit Breakers are 3000 525
available in a complete range of ANSI and 150VCP-W1500 13.8 1500 15.00 1.00 36 95 1200 63 5 2 15.00 63 170 101 525
2000 530
IEC ratings: 3000 550

ANSI 5 kV through 38 kV, Mini Modules


IEC-56 Standards Type VCP-W Vacuum Circuit Breaker Rated on Symmetrical Current Rating Basis
continuous currents from A Simple Building Block Approach Identification Rated Values Weight
600 through 3000 amperes. Easily Configured to Any Project Specification Circuit Voltage Insulation Level Normal Short Short Short Cable
IEC 3.6 kV through 36 kV, Mini Modules Configured as:
Breaker
Type
Class
Power Impulse
Current Circuit
Breaking
Time
(3 Second)
Circuit
Making
Charging
Breaking
Frequency Withstand
continuous currents from Current Current Current Current
A One-High Fully Equipped Breaker
630 through 2000 amperes. kV rms kV Peak kV Peak Amperes kA rms kA rms kA Peak Amperes kg
Compartment for 1200, 2000, 36VCPW-ND25 3.6 10 40 630, 1250 25 25 63 25 159
or 3000 Amperes. 36VCPW-ND32 3.6 10 40 630, 1250 31.5 31.5 79 25 159
ISO Certified Facilities 72VCPW-ND25 7.2 20 60 630, 1250 25 25 63 25 159
72VCPW-ND32 7.2 20 60 630, 1250 31.5 31.5 79 25 159
Type VCP-W Vacuum Circuit Breakers, 36VCP-W25 3.6 10 40 630, 1250, 2000 25 25 63 25 188
including the vacuum interrupter, are as- 36VCP-W32 3.6 10 40 1250, 2000 31.5 31.5 79 25 188
36VCP-W40 3.6 10 40 1250, 2000 40 40 100 25 225
sembled by Cutler-Hammer in ISO 9002
72VCP-W25 7.2 20 60 630, 1250, 2000 25 25 63 25 188
certified facilities. The breakers are fully Circuit Breaker Compartment Kits 72VCP-W32 7.2 20 60 1250, 2000 31.5 31.5 79 25 188
tested to ANSI and IEC standards and 72VCP-W40 7.2 20 60 1250, 2000 40 40 100 25 225
each is provided with its unique Quality Provide the Opportunity to Add the Most 120VCP-W25 12 28 75 630, 1250, 2000 25 25 63 25 195
Assurance Certificate that documents all Value and Include All Key Breaker/Cell 120VCP-W32 12 28 75 1250, 2000 31.5 31.5 79 25 195
120VCP-W40 12 28 75 1250, 2000 40 40 100 25 225
tests and inspections performed. Interfacing Parts Necessary to Build
175VCP-W25 17.5 38 95 1250, 2000 25 25 63 31.5 195
a Breaker Compartment 175VCP-W32 17.5 38 95 1250, 2000 31.5 31.5 79 31.5 195
175VCP-W40 17.5 38 95 1250, 2000 40 40 100 31.5 225
Assembly Flexibility
Applicable ANSI standards C37.04 - 1979, C37.09 - 1979, and C37.06 - Consult Application Data 32-265 for further information.
Assembly flexibility is provided with a
Auxiliary Drawer Compartment Kits 1987. Operating duty cycle CO-15 seconds-CO. Operating time values: Optional interrupting time of 3 cycles is available.
variety of industry leading value-added opening 30-45 ms, closing 45-60 ms and reclosing 18 cycles (300 ms).
approaches for assembling premier All Parts Necessary for Building Potential Also 3 second short time current carrying capability.
Nonstandard circuit breakers with High Close and Latch (momentary)
metal-clad switchgear. Customers have Transformer, Control Power Transformer, rating for special applications. Interrupting time is 3 cycles at 50/60 Hz. Rated operating sequence:
the unique opportunity to select the appro- or Fuse Drawer Compartments O-3 minutes-CO-3 minutes-CO.
priate building block approach to match
their manufacturing capabilities with those
of Cutler-Hammer.

Tools and Accessories


A Complete Selection of Standard
and Optional Tools and Accessories

2 11
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
The Industry Leader 5/15 kV Medium Voltage Breaker
in Vacuum Circuit Breakers Rating Chart

VacClad-W, the Cutler-Hammer vacuum The OEM Value-Added Approach to Circuit Protection ANSI Standards Type VCP-W Vacuum Circuit Breaker Rated on Symmetrical Current Rating Basis
switchgear family, has been engineered Identification Rated Values Weight
to feature a standardized design, inter-
Flexibility that Exceeds the Customers Requirements Circuit Nominal Nominal Voltage Insulation Level Current Interrupting Permissible Maximum Current Values
Breaker Voltage 3-Phase Time Tripping Voltage
changeable parts, slot and tab construction, Type Class MVA Maximum Voltage
Voltage Range
Withstand
Test Voltage
Continuous
Current
Short
Circuit
Delay Divided Maximum Closing and
Symmetrical Latching
Closing and
Latching
and industry-leading vacuum interrupter Type VCP-W Vacuum Circuit Breakers Class
Factor at 60 Hz Current
by K
Interrupting Capability Capability
(at Rated Capability Momentary
technology. This world class switchgear Industry Leading Vacuum Technology Power Impulse
Maximum kV)
K Times 2.7 K 1.6 K
includes the Type VCP-W Vacuum Circuit in ANSI 5/15 kV or IEC 3.6/17.5 kV Frequency Rated Short Times Rated Times Rated
Breaker which meets both ANSI and IEC Type VCP-W.
(1 Minute) Circuit Short Circuit Short Circuit
Current Current Current
electrical standards.
Type VCPW-SE.
E K I Y E/K
Type VCPW-ND. kV MVA kV rms kV rms kV Peak Amperes kA rms Cycles Seconds kV rms kA rms kA Peak kA rms lbs.
Industry-Leading Vacuum Technology
50VCPW-ND250 4.16 250 4.76 1.24 19 60 1200 29 5 2 3.85 36 97 58 345
Provides Unequaled Reliability 50VCP-W250 4.16 250 4.76 1.24 19 60 1200 29 5 2 3.85 36 97 58 350
2000 132 78 410
Cutler-Hammer now provides the industrys 3000 525
most complete family of technologically Power Modules 50VCP-W350 4.16 350 4.76 1.19 19 60 1200 41 5 2 4.00 49 132 78 460
advanced vacuum circuit breakers at 5 kV, 2000 490
Complete Structures 3000 525
15 kV, 27 kV, and 38 kV. Type VCP-W Including Fully Equipped Breaker 75VCP-W500 7.2 500 8.25 1.25 36 95 1200 33 5 2 6.60 41 111 66 375
Vacuum Circuit Breakers incorporate many Compartment and Auxiliary Provisions 2000 410
3000 525
design features which have been field
150VCP-W500 13.8 500 15.00 1.30 36 95 1200 18 5 2 11.50 23 62 37 350
proven with more than 25 years of vacuum 2000 97 58 410
interrupter design and manufacturing 3000 525
experiencecoupled with over 70 years 150VCP-W750 13.8 750 15.00 1.30 36 95 1200 28 5 2 11.50 36 97 58 350
2000 130 77 410
of power circuit breaker design and manu- 3000 525
facturing experience. 150VCP-W1000 13.8 1000 15.00 1.30 36 95 1200 37 5 2 11.50 48 130 77 460
2000 490
Type VCP-W Vacuum Circuit Breakers are 3000 525
available in a complete range of ANSI and 150VCP-W1500 13.8 1500 15.00 1.00 36 95 1200 63 5 2 15.00 63 170 101 525
2000 530
IEC ratings: 3000 550

ANSI 5 kV through 38 kV, Mini Modules


IEC-56 Standards Type VCP-W Vacuum Circuit Breaker Rated on Symmetrical Current Rating Basis
continuous currents from A Simple Building Block Approach Identification Rated Values Weight
600 through 3000 amperes. Easily Configured to Any Project Specification Circuit Voltage Insulation Level Normal Short Short Short Cable
IEC 3.6 kV through 36 kV, Mini Modules Configured as:
Breaker
Type
Class
Power Impulse
Current Circuit
Breaking
Time
(3 Second)
Circuit
Making
Charging
Breaking
Frequency Withstand
continuous currents from Current Current Current Current
A One-High Fully Equipped Breaker
630 through 2000 amperes. kV rms kV Peak kV Peak Amperes kA rms kA rms kA Peak Amperes kg
Compartment for 1200, 2000, 36VCPW-ND25 3.6 10 40 630, 1250 25 25 63 25 159
or 3000 Amperes. 36VCPW-ND32 3.6 10 40 630, 1250 31.5 31.5 79 25 159
ISO Certified Facilities 72VCPW-ND25 7.2 20 60 630, 1250 25 25 63 25 159
72VCPW-ND32 7.2 20 60 630, 1250 31.5 31.5 79 25 159
Type VCP-W Vacuum Circuit Breakers, 36VCP-W25 3.6 10 40 630, 1250, 2000 25 25 63 25 188
including the vacuum interrupter, are as- 36VCP-W32 3.6 10 40 1250, 2000 31.5 31.5 79 25 188
36VCP-W40 3.6 10 40 1250, 2000 40 40 100 25 225
sembled by Cutler-Hammer in ISO 9002
72VCP-W25 7.2 20 60 630, 1250, 2000 25 25 63 25 188
certified facilities. The breakers are fully Circuit Breaker Compartment Kits 72VCP-W32 7.2 20 60 1250, 2000 31.5 31.5 79 25 188
tested to ANSI and IEC standards and 72VCP-W40 7.2 20 60 1250, 2000 40 40 100 25 225
each is provided with its unique Quality Provide the Opportunity to Add the Most 120VCP-W25 12 28 75 630, 1250, 2000 25 25 63 25 195
Assurance Certificate that documents all Value and Include All Key Breaker/Cell 120VCP-W32 12 28 75 1250, 2000 31.5 31.5 79 25 195
120VCP-W40 12 28 75 1250, 2000 40 40 100 25 225
tests and inspections performed. Interfacing Parts Necessary to Build
175VCP-W25 17.5 38 95 1250, 2000 25 25 63 31.5 195
a Breaker Compartment 175VCP-W32 17.5 38 95 1250, 2000 31.5 31.5 79 31.5 195
175VCP-W40 17.5 38 95 1250, 2000 40 40 100 31.5 225
Assembly Flexibility
Applicable ANSI standards C37.04 - 1979, C37.09 - 1979, and C37.06 - Consult Application Data 32-265 for further information.
Assembly flexibility is provided with a
Auxiliary Drawer Compartment Kits 1987. Operating duty cycle CO-15 seconds-CO. Operating time values: Optional interrupting time of 3 cycles is available.
variety of industry leading value-added opening 30-45 ms, closing 45-60 ms and reclosing 18 cycles (300 ms).
approaches for assembling premier All Parts Necessary for Building Potential Also 3 second short time current carrying capability.
Nonstandard circuit breakers with High Close and Latch (momentary)
metal-clad switchgear. Customers have Transformer, Control Power Transformer, rating for special applications. Interrupting time is 3 cycles at 50/60 Hz. Rated operating sequence:
the unique opportunity to select the appro- or Fuse Drawer Compartments O-3 minutes-CO-3 minutes-CO.
priate building block approach to match
their manufacturing capabilities with those
of Cutler-Hammer.

Tools and Accessories


A Complete Selection of Standard
and Optional Tools and Accessories

2 11
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Metering, Protection, Industry Leading Vacuum
and Communications Technology Enhances Breaker
and Switchgear Reliability

Cutler-Hammer Power Management Products PROTECTIVE RELAYS COMMUNICATIONS Type VCP-W Vacuum Circuit Breakers
provide the solutions to monitor and manage
all aspects of an electrical distribution system. The highly dependable performance of
These innovative meters, relays and com- Cutler-Hammer vacuum circuit breakers
MP-3000 PowerNet results from our commitment to a continu-
munications software applications make it Award-Winning Flexible Power
possible to realize greater reliability, increased ing research and development program.
Motor Protection Management System World-class VCP-W Vacuum Circuit
productivity and significant cost savings. Beginning with early research in 1929, we Breakers designed with a patented
The MP-3000, winner PowerNet software is have been a leader in the vacuum inter- V-Flex nonsliding current transfer
of a Plant Engineering designed to manage the rupter field. Production was launched in system.
METERS magazine Product of power distribution system. Its ideal for managing the mid-1960s, and since that time hun-
the Year award, pro- energy usage and costs, troubleshooting power dreds of thousands of vacuum interrupters
tects three-phase in- quality problems and ensuring the reliability and
duction motors of any integrity of the electrical distribution system. A
have been in reliable operation worldwide.
IQ Analyzer 6400/ size and voltage. In- PowerNet Power Management System consists of Cutler-Hammer experience has resulted
tegral Intel-I-Trip PowerNet software networked with meters, relays,
6600 Series overload protection trip units, motor protectors, starters and transfer in many significant vacuum interrupter
The Premier Power develops protection switch controllers. PowerNet has an extensive li- breakthroughs including:
Quality Meter curves based on mo- brary of third-party interfaces, facilitating integration
tor data and adaptive characteristics based on mea- with other manufacturers devices and building man-
Copper chrome contact materials
sured RTD temperatures. The MP-3000 records agement systems. that provide longer life.
The IQ Analyzer pro-
vides comprehensive
motor history and time-stamped event logging in A smaller envelope size with
nonvolatile memory. This device is available in a higher performance.
diagnostic capabilities
quick-release drawout case model.
with over 150 metered
PowerPort Lower chop currents.
values. This device as-
sists in preventing pro- Single Device Monitoring and Configuration Software Improved dielectric strength.
cess disruptions and Consequently, Cutler-Hammer vacuum
equipment damage by PowerPort is free software downloadable from http:/
storing trends, analyz- interrupters are maintenance freeand
FP-5000 /www.ch.cutlerhammer.com/pmp/PowerPort.html. It is provide increased service life and opti-
ing harmonics and capturing waveforms. Historical a scaled-down version of Power Net. PowerPort
data captured by the IQ Analyzer helps to identify Integrated mum operator safety.
simplifies the setup and configuration of select Cut-
problems in an electrical distribution system. Energy Protection,
ler-Hammer devices, including the IQ Analyzer, MP-
usage and costs are controllable through highly Metering and 3000 and FP-5000, by enabling the user to enter the V-Flex System
accurate energy measurement, on-board energy Control for Electric Type VCP-W Vacuum Circuit Breakers Unique swaged design benefits include:
device setpoints via a user-friendly PC interface. Are Designed with the Patented
value storage and time-of-use energy registers. Power Distribution Then the information can be downloaded to the Improved current flow because
Optional graphical waveform and harmonic spec- V-Flex Nonsliding, Nonrolling
device, eliminating the need to scroll through the the multipoint contact offers very
trum display available on the 6600 series. device menu at the faceplate. A single device can be Current Transfer System
The FP-5000 provides low electrical and thermal resistance.
advanced protection monitored via PowerPort.
The current transfer system consists of a Unlike sliding or rolling designs,
for mains, tiers and
feeder circuits of any
series of tin-plated, high-conductivity cop- there are no moving parts to wear
voltage level. This de- per leaf conductors that are swaged onto outtherefore, no maintenance.
IQ DP-4000 vice provides com- the movable interrupter stem. Longer circuit breaker service life.
plete three-phase and ground protection, time GENESIS32
Metering and Voltage
Protection
overcurrent protection with 11 user-selectable char- Web-Based HMI
acteristic curve shapes, three custom curves, over Software
and under voltage and frequency protection, phase
The IQ DP-4000 provides sequence voltage protection, current unbalance pro-
tection and breaker failure protection. It provides GENESIS32 is Cutler-Hammers graphical solution Arcing and Interruption Phenomena of Relevance
complete electrical me- Current
complete metering and advanced data logging ca- and includes GraphWorx, TrendWorx, AlarmWorx Path to AC Switching
tering and system voltage
protection. This device pabilities. The FP-5000 is available in a quick- and Web HMI software. The basic bundle also High
measures and displays release drawout case model. includes an integrators tool of Modbus to OPC to Arc Current Current
facilitate the communications with Modbus devices Driving Initiation Arc Mode Zero
over 74 electrical system Force
values. It measures % total harmonic distortion in your network. These applications provide custom- on the
(%THD) for both current and voltage to help find the ized graphical displays, ease of integration and Columnar Fault
portability of data throughout the enterprise network, Current
source of problems. The IQ DP-4000 keeps track of Arc
total energy used along with the maximum demand even via a web browser thin client. This bundle Contact Interrupter
to aid in energy management. Optional digital I/O Digitrip 3000 provides the flexible and powerful graphic applica- Segments Stem Time, ms Time, s
tions that are easily deployed.
available on the 4100 series. Increased Protection
Recovery
for Medium Voltage GENESIS32 is a trademark of ICONICS. Arc Voltage
Circuit Breakers

IQ 200 The Digitrip 3000 provides ACCESSORIES Nonsliding Current Transfer System Arcing and Interruption in Vacuum Arcing and Interruption Phenomena
three-phase and ground
Switchboard Metering Connecting each leaf conductor to the vacuum Inside the vacuum bottle, the spiral contact design of Relevance to AC Switching
overcurrent instantaneous EZC Minalites interrupter stem initiates a flattening operation of the configuration provides a self-induced magnetic The important arcing and interruption phenomena
protection in a single, cost-
effective package. It also segments which are, in turn, swaged into contact effect that moves the arc root around the contact that occur during fault current interruption in a vacuum
The IQ 200 family is a group of with the stem. Each leaf, therefore, provides a are depicted above. These phenomena influence
provides current and moni- periphery. This type of arc control prevents hot spot
revenue accurate ANSI the design of the interrupter, particularly its size,
toring capability. Optional multipoint connection. As the stem moves up and formations and minimizes electrode erosion. The
C12.16 meters that provide big
zone selective interlocking is an alternative to high down, the V-Flex system flexes, eliminating the low resistance of the spiral design results in less configuration, and material of the contacts. Full
features in a small and flexible sliding action to provide a minimal wear and main- dielectric strength is re-established to withstand
bus cost differential protection. The selectable long heat to dissipate, providing the smallest possible
package. They are ideal for transient recovery voltage (TRV) within a few micro-
time curve slope (ANSI: Moderately inverse, very tenance-free system. envelope size.
panelboard and switchboard applications where
inverse, and extremely inverse and thermal curves: seconds, the fastest available.
panel space is at a premium. Energy management
information is provided by direct reading of metered It, T2t, T4t, flat) provides protection for a wide range
values. With built-in communications the IQ 200 of protection capability in a single device.
base can be used as a metering transducer for Compact indicating lights for general indicating or
submetering applications. signaling. They are quickly and easily mounted on
panels up to and including 1/4 inch in thickness.
Round and rectangular designs are available.

10 3
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Metering, Protection, Industry Leading Vacuum
and Communications Technology Enhances Breaker
and Switchgear Reliability

Cutler-Hammer Power Management Products PROTECTIVE RELAYS COMMUNICATIONS Type VCP-W Vacuum Circuit Breakers
provide the solutions to monitor and manage
all aspects of an electrical distribution system. The highly dependable performance of
These innovative meters, relays and com- Cutler-Hammer vacuum circuit breakers
MP-3000 PowerNet results from our commitment to a continu-
munications software applications make it Award-Winning Flexible Power
possible to realize greater reliability, increased ing research and development program.
Motor Protection Management System World-class VCP-W Vacuum Circuit
productivity and significant cost savings. Beginning with early research in 1929, we Breakers designed with a patented
The MP-3000, winner PowerNet software is have been a leader in the vacuum inter- V-Flex nonsliding current transfer
of a Plant Engineering designed to manage the rupter field. Production was launched in system.
METERS magazine Product of power distribution system. Its ideal for managing the mid-1960s, and since that time hun-
the Year award, pro- energy usage and costs, troubleshooting power dreds of thousands of vacuum interrupters
tects three-phase in- quality problems and ensuring the reliability and
duction motors of any integrity of the electrical distribution system. A
have been in reliable operation worldwide.
IQ Analyzer 6400/ size and voltage. In- PowerNet Power Management System consists of Cutler-Hammer experience has resulted
tegral Intel-I-Trip PowerNet software networked with meters, relays,
6600 Series overload protection trip units, motor protectors, starters and transfer in many significant vacuum interrupter
The Premier Power develops protection switch controllers. PowerNet has an extensive li- breakthroughs including:
Quality Meter curves based on mo- brary of third-party interfaces, facilitating integration
tor data and adaptive characteristics based on mea- with other manufacturers devices and building man-
Copper chrome contact materials
sured RTD temperatures. The MP-3000 records agement systems. that provide longer life.
The IQ Analyzer pro-
vides comprehensive
motor history and time-stamped event logging in A smaller envelope size with
nonvolatile memory. This device is available in a higher performance.
diagnostic capabilities
quick-release drawout case model.
with over 150 metered
PowerPort Lower chop currents.
values. This device as-
sists in preventing pro- Single Device Monitoring and Configuration Software Improved dielectric strength.
cess disruptions and Consequently, Cutler-Hammer vacuum
equipment damage by PowerPort is free software downloadable from http:/
storing trends, analyz- interrupters are maintenance freeand
FP-5000 /www.ch.cutlerhammer.com/pmp/PowerPort.html. It is provide increased service life and opti-
ing harmonics and capturing waveforms. Historical a scaled-down version of Power Net. PowerPort
data captured by the IQ Analyzer helps to identify Integrated mum operator safety.
simplifies the setup and configuration of select Cut-
problems in an electrical distribution system. Energy Protection,
ler-Hammer devices, including the IQ Analyzer, MP-
usage and costs are controllable through highly Metering and 3000 and FP-5000, by enabling the user to enter the V-Flex System
accurate energy measurement, on-board energy Control for Electric Type VCP-W Vacuum Circuit Breakers Unique swaged design benefits include:
device setpoints via a user-friendly PC interface. Are Designed with the Patented
value storage and time-of-use energy registers. Power Distribution Then the information can be downloaded to the Improved current flow because
Optional graphical waveform and harmonic spec- V-Flex Nonsliding, Nonrolling
device, eliminating the need to scroll through the the multipoint contact offers very
trum display available on the 6600 series. device menu at the faceplate. A single device can be Current Transfer System
The FP-5000 provides low electrical and thermal resistance.
advanced protection monitored via PowerPort.
The current transfer system consists of a Unlike sliding or rolling designs,
for mains, tiers and
feeder circuits of any
series of tin-plated, high-conductivity cop- there are no moving parts to wear
voltage level. This de- per leaf conductors that are swaged onto outtherefore, no maintenance.
IQ DP-4000 vice provides com- the movable interrupter stem. Longer circuit breaker service life.
plete three-phase and ground protection, time GENESIS32
Metering and Voltage
Protection
overcurrent protection with 11 user-selectable char- Web-Based HMI
acteristic curve shapes, three custom curves, over Software
and under voltage and frequency protection, phase
The IQ DP-4000 provides sequence voltage protection, current unbalance pro-
tection and breaker failure protection. It provides GENESIS32 is Cutler-Hammers graphical solution Arcing and Interruption Phenomena of Relevance
complete electrical me- Current
complete metering and advanced data logging ca- and includes GraphWorx, TrendWorx, AlarmWorx Path to AC Switching
tering and system voltage
protection. This device pabilities. The FP-5000 is available in a quick- and Web HMI software. The basic bundle also High
measures and displays release drawout case model. includes an integrators tool of Modbus to OPC to Arc Current Current
facilitate the communications with Modbus devices Driving Initiation Arc Mode Zero
over 74 electrical system Force
values. It measures % total harmonic distortion in your network. These applications provide custom- on the
(%THD) for both current and voltage to help find the ized graphical displays, ease of integration and Columnar Fault
portability of data throughout the enterprise network, Current
source of problems. The IQ DP-4000 keeps track of Arc
total energy used along with the maximum demand even via a web browser thin client. This bundle Contact Interrupter
to aid in energy management. Optional digital I/O Digitrip 3000 provides the flexible and powerful graphic applica- Segments Stem Time, ms Time, s
tions that are easily deployed.
available on the 4100 series. Increased Protection
Recovery
for Medium Voltage GENESIS32 is a trademark of ICONICS. Arc Voltage
Circuit Breakers

IQ 200 The Digitrip 3000 provides ACCESSORIES Nonsliding Current Transfer System Arcing and Interruption in Vacuum Arcing and Interruption Phenomena
three-phase and ground
Switchboard Metering Connecting each leaf conductor to the vacuum Inside the vacuum bottle, the spiral contact design of Relevance to AC Switching
overcurrent instantaneous EZC Minalites interrupter stem initiates a flattening operation of the configuration provides a self-induced magnetic The important arcing and interruption phenomena
protection in a single, cost-
effective package. It also segments which are, in turn, swaged into contact effect that moves the arc root around the contact that occur during fault current interruption in a vacuum
The IQ 200 family is a group of with the stem. Each leaf, therefore, provides a are depicted above. These phenomena influence
provides current and moni- periphery. This type of arc control prevents hot spot
revenue accurate ANSI the design of the interrupter, particularly its size,
toring capability. Optional multipoint connection. As the stem moves up and formations and minimizes electrode erosion. The
C12.16 meters that provide big
zone selective interlocking is an alternative to high down, the V-Flex system flexes, eliminating the low resistance of the spiral design results in less configuration, and material of the contacts. Full
features in a small and flexible sliding action to provide a minimal wear and main- dielectric strength is re-established to withstand
bus cost differential protection. The selectable long heat to dissipate, providing the smallest possible
package. They are ideal for transient recovery voltage (TRV) within a few micro-
time curve slope (ANSI: Moderately inverse, very tenance-free system. envelope size.
panelboard and switchboard applications where
inverse, and extremely inverse and thermal curves: seconds, the fastest available.
panel space is at a premium. Energy management
information is provided by direct reading of metered It, T2t, T4t, flat) provides protection for a wide range
values. With built-in communications the IQ 200 of protection capability in a single device.
base can be used as a metering transducer for Compact indicating lights for general indicating or
submetering applications. signaling. They are quickly and easily mounted on
panels up to and including 1/4 inch in thickness.
Round and rectangular designs are available.

10 3
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Type VCP-W Vacuum Circuit Breaker Tools and Accessories
A New Level of Standardization

All Type VCP-W Vacuum Circuit Breakers, VCP-W Vacuum Circuit


regardless of voltage or interrupting ca- Cutler-Hammer provides several standard and optional accessories including equipment used to transport
Breaker Compartment the breaker and lift and lever it into a compartment, as well as a manually operated ground and test device.
pacity, have the same time proven stored
energy mechanismand are significantly
smaller than conventional medium voltage 1
1 Metal shutters

drawout breakers in both size and weight.


2 Ground stab assembly The optional por- Optional accessories
Refer to weights table on page 11. table lifter is used include (clockwise):

3 Breaker position indicator to lift the breaker lifting yoke, test cabi-
from or onto the net, spin-free levering
Three Methods of Easy Installation
4 Levering mechanism
extension rails. crank, and test jumper.

Lower Compartment Installation


5 MOC/TOC switch location

1. A roll off the floor ramp.


6 Drawout type secondaries

2. A dockable dolly.
The floor ramp or dockable dolly is used
for quick lower cell installation or removal.
6
Upper and Lower Compartment Installation 5
3. A lifting yoke that is compatible with 2 4
any standard lifting device.
3
Since the breaker rides on extension rails,
Standard accessories
alignment problems are eliminated and include (top to bot-
installation time is reduced. Additionally, tom): manual charg-
a position indicator shows when the ing handle, left and
breaker is in the fully connected or dis- right removable exten-
connected position. VCP-W Vacuum sion rails, rail clamps,
and levering crank.
Circuit Breaker
Designed for Operator Safety

7 Vacuum interrupter
Two dead front shields are provided to
isolate the operator from high voltage
8 Patented V-Flex nonsliding, non-
rolling current transfer system
when the breaker is energized.
During levering, safety interlocks render

9 Direct reading contact
7 erosion indicator
the breaker mechanically trip free and the
breaker is grounded throughout its travel. 9
10 Breaker wheels
11
The T handle latch which engages and
11 Removable glass polyester
disengages the breaker is at the bottom insulating barriers
of the breaker, far from energized parts. 8
When the breaker is withdrawn, steel shut-
ters automatically rotate to cover the pri-
mary disconnect supportsand a current
transformer barrier is located in front of the
shutters. This prevents the operator from
accidental contact with primary voltage
parts and controls.
10

A dockable dolly
for transporting the

12 Front panel controls and indicators lower breaker to or
from the lower com-

13 Removable dead front cover partment.

13
14 T handle latch


15 Drawout type secondaries

12

Optional ground and test devices,


include manually operated, Bail
A roll off the floor ramp is used to Type manually operated, electrically
move the lower breaker from the operated, and Consolidated Edison
floor to the bottom compartment. user type (shown). Dummy elements
are also available.
14
15

4 9
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Type VCP-W Vacuum Circuit Breaker Tools and Accessories
A New Level of Standardization

All Type VCP-W Vacuum Circuit Breakers, VCP-W Vacuum Circuit


regardless of voltage or interrupting ca- Cutler-Hammer provides several standard and optional accessories including equipment used to transport
Breaker Compartment the breaker and lift and lever it into a compartment, as well as a manually operated ground and test device.
pacity, have the same time proven stored
energy mechanismand are significantly
smaller than conventional medium voltage 1
1 Metal shutters

drawout breakers in both size and weight.


2 Ground stab assembly The optional por- Optional accessories
Refer to weights table on page 11. table lifter is used include (clockwise):

3 Breaker position indicator to lift the breaker lifting yoke, test cabi-
from or onto the net, spin-free levering
Three Methods of Easy Installation
4 Levering mechanism
extension rails. crank, and test jumper.

Lower Compartment Installation


5 MOC/TOC switch location

1. A roll off the floor ramp.


6 Drawout type secondaries

2. A dockable dolly.
The floor ramp or dockable dolly is used
for quick lower cell installation or removal.
6
Upper and Lower Compartment Installation 5
3. A lifting yoke that is compatible with 2 4
any standard lifting device.
3
Since the breaker rides on extension rails,
Standard accessories
alignment problems are eliminated and include (top to bot-
installation time is reduced. Additionally, tom): manual charg-
a position indicator shows when the ing handle, left and
breaker is in the fully connected or dis- right removable exten-
connected position. VCP-W Vacuum sion rails, rail clamps,
and levering crank.
Circuit Breaker
Designed for Operator Safety

7 Vacuum interrupter
Two dead front shields are provided to
isolate the operator from high voltage
8 Patented V-Flex nonsliding, non-
rolling current transfer system
when the breaker is energized.
During levering, safety interlocks render

9 Direct reading contact
7 erosion indicator
the breaker mechanically trip free and the
breaker is grounded throughout its travel. 9
10 Breaker wheels
11
The T handle latch which engages and
11 Removable glass polyester
disengages the breaker is at the bottom insulating barriers
of the breaker, far from energized parts. 8
When the breaker is withdrawn, steel shut-
ters automatically rotate to cover the pri-
mary disconnect supportsand a current
transformer barrier is located in front of the
shutters. This prevents the operator from
accidental contact with primary voltage
parts and controls.
10

A dockable dolly
for transporting the

12 Front panel controls and indicators lower breaker to or
from the lower com-

13 Removable dead front cover partment.

13
14 T handle latch


15 Drawout type secondaries

12

Optional ground and test devices,


include manually operated, Bail
A roll off the floor ramp is used to Type manually operated, electrically
move the lower breaker from the operated, and Consolidated Edison
floor to the bottom compartment. user type (shown). Dummy elements
are also available.
14
15

4 9
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Auxiliary Drawer Compartment Kits for Cutler-Hammer Vacuum Circuit Breakers
Power Modules, Mini Modules, or Breaker Are Convenient to Operate, Simple
Compartment Kit Value Added Approaches to Inspect, and Easy to Maintain

These kits include all major parts used in assembling an auxiliary compartment. Each kit is shipped in a User-Friendly Operation
single carton with detailed instructions and drawings that include important dimensions, clearances and
configurations. Power Module B-Planes are prepunched to accommodate any auxiliary compartment kit. Type VCP-W Vacuum Circuit Breaker
controls and indicators are functionally
grouped on the front control panel and
Parts include: include: contact position indicator, closing
Potential Transformer Drawer Kit spring status, close and trip button, opera-
Left and right drawout rails.
tion counter, and a breaker T handle latch
PT truck assembly. (Potential transform-
(located at the bottom of the control panel).
ers and fuse mountings are not included.)
Primary and secondary contact assem- The simplified design includes just five
blies, standoff insulators, and cable major components: vacuum interrupter
supports. pole units, stored energy mechanism,
Shutter assembly. push rod assembly, primary disconnecting
Hardware for cell mountings and contacts, and removable glass polyester
alignment brackets. insulating barriers.
Horizontal sectioning barriers.
Drawings are provided for manufacturing Convenient Inspection
the back sheet. They also detail the clear-
ances and locations of integral parts. The breaker is withdrawn on removable
extension rails and no separate lifting
Detailed assembly instructions.
device is required. There is no need to
Available for 36 inch wide standard
remove the breaker from the switchgear.
and 26 inch wide narrow design switch-
With the breaker withdrawn, both the com-
UL Recognized gear configurations.
partment and contact erosion indicator,
and T cutout loading spring indicator can
be visually inspected.
Control Power Transformer Parts include:
Left and right drawout rails. Both stored energy mechanism and con-
Drawer Kit trol components are conveniently located
CPT truck assembly including glass
polyester barriers and secondary fuse behind the easily removed front panel.
mountings. (Control power transformers The current transformer barrier is easily
are not included.) removed for inspection and access to the
Primary and secondary contact assemblies. current transformers. Auxiliary drawers
Shutter assembly, standoff insulators, and
use extension rails to provide for easy
cable supports. inspection and fuse replacement.
Hardware for all configurations and align-
ments including mounting and alignment Easy Maintenance
brackets.
Type VCP-W Vacuum Circuit Breakers
Horizontal sectioning barriers. Stored energy mechanism is conven-
are easily maintained. The easy access iently located behind the removable front
Drawings are provided for manufacturing mechanism and control components can panel. The front mounting of the mecha-
the back sheet. They also detail the clear- be conveniently inspected and minor nism provides two dead front shields
ances and locations of integral parts. maintenance (such as lubricating the between the operator and high voltage
Detailed assembly instructions. mechanism and replacing control compo- when the circuit breaker is energized.
Available for 36 inch wide standard nents) is uncomplicated.
and 26 inch wide narrow design switch-
UL Recognized gear configurations. Simplified Maintenance through Visual Inspection of Indicators
A Standardized Line
Type VCP-W Vacuum Circuit Breakers
Fuse Drawer Kit Parts include: represent a standard line that utilizes com-
Left and right drawout rails. mon parts. Standardization provides for
Fuse truck assembly including fuse
fewer total parts which, in turn, reduces
holder assembly and various fuse and simplifies the spare parts inventory.
mountings. (Fuses are not included.) Type VCP-W Vacuum Circuit Breakers of Contact
the same ratings are totally interchange- Erosion
Primary contact assemblies. T
able between structures. Indicator Cutout
Shutter assembly, standoff insulators, and
Indicator
cable supports.
Hardware for all configurations and align-
ments including mounting and alignment
brackets.
Horizontal sectioning barriers.
Drawings are provided for manufacturing Easy-to-See Contact Erosion Indicator Convenient Loading Spring Indicator
the back sheet. They also detail the clear- The vacuum interrupter direct reading Visual inspection of the T cutout load-
ances and locations of integral parts. contact erosion indicator is clearly vis- ing spring indicator insures that when
Detailed assembly instructions. ible. Only periodic inspection of the closing the breaker, the loading springs
erosion indicator is required. are applying proper pressure to the
Available for 36 inch wide standard
contacts.
and 26 inch wide narrow design switch-
UL Recognized gear configurations.

8 5
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
Auxiliary Drawer Compartment Kits for Cutler-Hammer Vacuum Circuit Breakers
Power Modules, Mini Modules, or Breaker Are Convenient to Operate, Simple
Compartment Kit Value Added Approaches to Inspect, and Easy to Maintain

These kits include all major parts used in assembling an auxiliary compartment. Each kit is shipped in a User-Friendly Operation
single carton with detailed instructions and drawings that include important dimensions, clearances and
configurations. Power Module B-Planes are prepunched to accommodate any auxiliary compartment kit. Type VCP-W Vacuum Circuit Breaker
controls and indicators are functionally
grouped on the front control panel and
Parts include: include: contact position indicator, closing
Potential Transformer Drawer Kit spring status, close and trip button, opera-
Left and right drawout rails.
tion counter, and a breaker T handle latch
PT truck assembly. (Potential transform-
(located at the bottom of the control panel).
ers and fuse mountings are not included.)
Primary and secondary contact assem- The simplified design includes just five
blies, standoff insulators, and cable major components: vacuum interrupter
supports. pole units, stored energy mechanism,
Shutter assembly. push rod assembly, primary disconnecting
Hardware for cell mountings and contacts, and removable glass polyester
alignment brackets. insulating barriers.
Horizontal sectioning barriers.
Drawings are provided for manufacturing Convenient Inspection
the back sheet. They also detail the clear-
ances and locations of integral parts. The breaker is withdrawn on removable
extension rails and no separate lifting
Detailed assembly instructions.
device is required. There is no need to
Available for 36 inch wide standard
remove the breaker from the switchgear.
and 26 inch wide narrow design switch-
With the breaker withdrawn, both the com-
UL Recognized gear configurations.
partment and contact erosion indicator,
and T cutout loading spring indicator can
be visually inspected.
Control Power Transformer Parts include:
Left and right drawout rails. Both stored energy mechanism and con-
Drawer Kit trol components are conveniently located
CPT truck assembly including glass
polyester barriers and secondary fuse behind the easily removed front panel.
mountings. (Control power transformers The current transformer barrier is easily
are not included.) removed for inspection and access to the
Primary and secondary contact assemblies. current transformers. Auxiliary drawers
Shutter assembly, standoff insulators, and
use extension rails to provide for easy
cable supports. inspection and fuse replacement.
Hardware for all configurations and align-
ments including mounting and alignment Easy Maintenance
brackets.
Type VCP-W Vacuum Circuit Breakers
Horizontal sectioning barriers. Stored energy mechanism is conven-
are easily maintained. The easy access iently located behind the removable front
Drawings are provided for manufacturing mechanism and control components can panel. The front mounting of the mecha-
the back sheet. They also detail the clear- be conveniently inspected and minor nism provides two dead front shields
ances and locations of integral parts. maintenance (such as lubricating the between the operator and high voltage
Detailed assembly instructions. mechanism and replacing control compo- when the circuit breaker is energized.
Available for 36 inch wide standard nents) is uncomplicated.
and 26 inch wide narrow design switch-
UL Recognized gear configurations. Simplified Maintenance through Visual Inspection of Indicators
A Standardized Line
Type VCP-W Vacuum Circuit Breakers
Fuse Drawer Kit Parts include: represent a standard line that utilizes com-
Left and right drawout rails. mon parts. Standardization provides for
Fuse truck assembly including fuse
fewer total parts which, in turn, reduces
holder assembly and various fuse and simplifies the spare parts inventory.
mountings. (Fuses are not included.) Type VCP-W Vacuum Circuit Breakers of Contact
the same ratings are totally interchange- Erosion
Primary contact assemblies. T
able between structures. Indicator Cutout
Shutter assembly, standoff insulators, and
Indicator
cable supports.
Hardware for all configurations and align-
ments including mounting and alignment
brackets.
Horizontal sectioning barriers.
Drawings are provided for manufacturing Easy-to-See Contact Erosion Indicator Convenient Loading Spring Indicator
the back sheet. They also detail the clear- The vacuum interrupter direct reading Visual inspection of the T cutout load-
ances and locations of integral parts. contact erosion indicator is clearly vis- ing spring indicator insures that when
Detailed assembly instructions. ible. Only periodic inspection of the closing the breaker, the loading springs
erosion indicator is required. are applying proper pressure to the
Available for 36 inch wide standard
contacts.
and 26 inch wide narrow design switch-
UL Recognized gear configurations.

8 5
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
No More than You Want
No Less than You Need

A Modular Value-Added Approach to Circuit ProtectionExclusively from Cutler-Hammer


26-Inch Narrow Design 36-Inch Standard Design

5/15 kV Power modules are ideal for OEMs who The breaker can be inserted in the Power Module Ampere Ratings
supply standard through complex switch- upper or lower compartment.
Power Modules gear. The OEM provides value-added items
26" Narrow Design 1200A
Two auxiliary drawers (for PTs, CPT, 36" Standard Design 1200A, 2000A, 3000A
Provide OEMs such as doors, bus, cable area compart- or fuses) can be located in the upper
with a ments, instruments, relays and associated or lower blank auxiliary compartment. Available Configurations
Complete Structure wiring. The power module incorporates Auxiliary compartment kits can be
1200 1200
individual vertical sections which will en- easily installed into any blank auxiliary
Both Amp Amp
26" Narrow
close a maximum of two Type VCP-W power module compartment to suit and
Circuit Breakers or four auxiliary drawers any PT, CPT, or fuse drawer. 36" Standard 1200 1200
Design Amp Amp
or a combination of one Type VCP-W
All blank auxiliary B-Planes are
Circuit Breaker and two auxiliary drawers.
prepunched to accept a PT, CPT,

A complete structure including fully or fuse drawer kit. 36" Standard 1200
Amp
2000
Amp
2000
Amp
Design Only
equipped circuit breaker and blank aux- Exclusive 3,000 ampere breaker in the
iliary compartment, control compartment, upper compartment with a single aux- 2000 1200 2000
and main bus compartmentplus side iliary drawer in the lower compartment. Amp

Amp

Amp

and back sheets, roof assembly, door 4000 ampere forced air cooled power
hinges/stops, and ventilation chimney. modules are also available. 3000
Blank Amp
36 inch wide design available Available with glass polyester or
Breaker Compartment
in 10 configurations. porcelain insulating tubes for either Blank Blank Auxiliary
3000
26 inch wide narrow design available 41 kA, 50 kA, or 63 kA applications. Amp

UL Recognized in four configurations.

5/15 kV A simple building block approach in which Different bus terminal configurations Mini Module Ampere Ratings
Mini Modules the OEM provides value-added items such available for upper or lower com- 26" Narrow Design 1200A
as doors, bus, cable area compartment, partments.
36" Standard Design 1200A, 2000A, 3000A
Provide OEMs side sheets, instruments, relays, and as- Boxed frame, levering-in assembly,
with a More Value- sociated wiring. Easily configured to suit glass polyester or porcelain insulating
Added Approach many applications. Mini modules are avail- tubes for either 41 kA, 50 kA, or 63 kA
able as: applications, current transformer barrier,
1200, 2000, or 3000 ampere breaker and shutter assembly.
compartment designs.
UL Recognized

5/15 kV Circuit breaker compartment kits provide a Primary disconnect supports Compartment Kit Specifications
Circuit Breaker maximum value-added approach to building (upper and lower). Ampere Primary Disconnect Stab
switchgear, combining maximum design Current transformer barrier assembly. Rating Supports Arrangements
Compartment Kits flexibility with cost competitiveness. Each Shutter assembly. 26" Narrow Design
Provide OEMs circuit breaker compartment kit includes:
Glass polyester or porcelain insulating 1200A Glass Polyester Line and Load
with the Slot and tab design that assures all tubes for either 41 kA, 50 kA, 36" Standard Design
Opportunity critical breaker/structure interfaces are or 63 kA applications.
to Add the 1200A Glass Polyester Line and Load or Line/Line
maintained, eliminating the potential Drawings that include dimensions or Porcelain Line and Load or Line/Line
Most Value distortion problems that can occur and clearances are provided. B-Plane 2000A Glass Polyester Line and Load or Line/Line
with conventional weld/bend designs. sheets are provided by the OEM to or Porcelain Line and Load or Line/Line
Breaker levering-in assembly with maximize a staged production process. 3000A Glass Polyester Line and Load
UL Recognized left and right drawer drawout rails. or Porcelain Line and Load

5/15 kV Type VCPW-ND Type VCP-W / VCP-WC / VCP-WG Type VCPW-SE


Vacuum Medium Voltage Vacuum Circuit Breaker Medium Voltage Vacuum Circuit Breaker Medium Voltage Vacuum Circuit Breaker
Circuit Breakers The Type VCPW-ND Circuit Breaker offers As with all Cutler-Hammer vacuum circuit The Type VCPW-SE Vacuum Circuit
proven industry leading vacuum circuit breakers, reliability of the standard design Breaker is designed for 36 inch wide
breaker technology in a 26 inch wide Type VCP-W Vacuum Circuit Breaker has switchgear applications and includes
switchgear design, making it ideal for use been proven by over 25 years of vacuum cycloaliphatic epoxy insulation and cross
when the benefits of a vacuum breaker are circuit breaker design and manufacturing linked polyolefin insulated control wire,
required and installation space is limited. experience. The breaker is designed for making it ideal for use in harsh industrial
The breaker is ANSI rated at 5 kV and IEC 36 inch wide switchgear and is ANSI rated environments. The breaker is ANSI rated
rated at 3.6/7.2 kV.* at 5/15 kV and IEC rated at 3.6/17.5 kV.* at 5/15 kV, and IEC rated at 3.6/17.5 kV.*
Contact
Segments
Interrupter
Stem

Listed option is available Type VCPW-ND Type VCP-W / VCP-WC Type VCP-WG Type VCPW-SE

* Refer to page 11 for specific breaker ratings. UL listing, 3-cycle ratings, undervoltage release, and second shunt trip are optionally available.
6 7
Cutler-Hammer Products Cutler-Hammer 5/15 kV Medium Voltage Switchgear Components
No More than You Want
No Less than You Need

A Modular Value-Added Approach to Circuit ProtectionExclusively from Cutler-Hammer


26-Inch Narrow Design 36-Inch Standard Design

5/15 kV Power modules are ideal for OEMs who The breaker can be inserted in the Power Module Ampere Ratings
supply standard through complex switch- upper or lower compartment.
Power Modules gear. The OEM provides value-added items
26" Narrow Design 1200A
Two auxiliary drawers (for PTs, CPT, 36" Standard Design 1200A, 2000A, 3000A
Provide OEMs such as doors, bus, cable area compart- or fuses) can be located in the upper
with a ments, instruments, relays and associated or lower blank auxiliary compartment. Available Configurations
Complete Structure wiring. The power module incorporates Auxiliary compartment kits can be
1200 1200
individual vertical sections which will en- easily installed into any blank auxiliary
Both Amp Amp
26" Narrow
close a maximum of two Type VCP-W power module compartment to suit and
Circuit Breakers or four auxiliary drawers any PT, CPT, or fuse drawer. 36" Standard 1200 1200
Design Amp Amp
or a combination of one Type VCP-W
All blank auxiliary B-Planes are
Circuit Breaker and two auxiliary drawers.
prepunched to accept a PT, CPT,

A complete structure including fully or fuse drawer kit. 36" Standard 1200
Amp
2000
Amp
2000
Amp
Design Only
equipped circuit breaker and blank aux- Exclusive 3,000 ampere breaker in the
iliary compartment, control compartment, upper compartment with a single aux- 2000 1200 2000
and main bus compartmentplus side iliary drawer in the lower compartment. Amp

Amp

Amp

and back sheets, roof assembly, door 4000 ampere forced air cooled power
hinges/stops, and ventilation chimney. modules are also available. 3000
Blank Amp
36 inch wide design available Available with glass polyester or
Breaker Compartment
in 10 configurations. porcelain insulating tubes for either Blank Blank Auxiliary
3000
26 inch wide narrow design available 41 kA, 50 kA, or 63 kA applications. Amp

UL Recognized in four configurations.

5/15 kV A simple building block approach in which Different bus terminal configurations Mini Module Ampere Ratings
Mini Modules the OEM provides value-added items such available for upper or lower com- 26" Narrow Design 1200A
as doors, bus, cable area compartment, partments.
36" Standard Design 1200A, 2000A, 3000A
Provide OEMs side sheets, instruments, relays, and as- Boxed frame, levering-in assembly,
with a More Value- sociated wiring. Easily configured to suit glass polyester or porcelain insulating
Added Approach many applications. Mini modules are avail- tubes for either 41 kA, 50 kA, or 63 kA
able as: applications, current transformer barrier,
1200, 2000, or 3000 ampere breaker and shutter assembly.
compartment designs.
UL Recognized

5/15 kV Circuit breaker compartment kits provide a Primary disconnect supports Compartment Kit Specifications
Circuit Breaker maximum value-added approach to building (upper and lower). Ampere Primary Disconnect Stab
switchgear, combining maximum design Current transformer barrier assembly. Rating Supports Arrangements
Compartment Kits flexibility with cost competitiveness. Each Shutter assembly. 26" Narrow Design
Provide OEMs circuit breaker compartment kit includes:
Glass polyester or porcelain insulating 1200A Glass Polyester Line and Load
with the Slot and tab design that assures all tubes for either 41 kA, 50 kA, 36" Standard Design
Opportunity critical breaker/structure interfaces are or 63 kA applications.
to Add the 1200A Glass Polyester Line and Load or Line/Line
maintained, eliminating the potential Drawings that include dimensions or Porcelain Line and Load or Line/Line
Most Value distortion problems that can occur and clearances are provided. B-Plane 2000A Glass Polyester Line and Load or Line/Line
with conventional weld/bend designs. sheets are provided by the OEM to or Porcelain Line and Load or Line/Line
Breaker levering-in assembly with maximize a staged production process. 3000A Glass Polyester Line and Load
UL Recognized left and right drawer drawout rails. or Porcelain Line and Load

5/15 kV Type VCPW-ND Type VCP-W / VCP-WC / VCP-WG Type VCPW-SE


Vacuum Medium Voltage Vacuum Circuit Breaker Medium Voltage Vacuum Circuit Breaker Medium Voltage Vacuum Circuit Breaker
Circuit Breakers The Type VCPW-ND Circuit Breaker offers As with all Cutler-Hammer vacuum circuit The Type VCPW-SE Vacuum Circuit
proven industry leading vacuum circuit breakers, reliability of the standard design Breaker is designed for 36 inch wide
breaker technology in a 26 inch wide Type VCP-W Vacuum Circuit Breaker has switchgear applications and includes
switchgear design, making it ideal for use been proven by over 25 years of vacuum cycloaliphatic epoxy insulation and cross
when the benefits of a vacuum breaker are circuit breaker design and manufacturing linked polyolefin insulated control wire,
required and installation space is limited. experience. The breaker is designed for making it ideal for use in harsh industrial
The breaker is ANSI rated at 5 kV and IEC 36 inch wide switchgear and is ANSI rated environments. The breaker is ANSI rated
rated at 3.6/7.2 kV.* at 5/15 kV and IEC rated at 3.6/17.5 kV.* at 5/15 kV, and IEC rated at 3.6/17.5 kV.*
Contact
Segments
Interrupter
Stem

Listed option is available Type VCPW-ND Type VCP-W / VCP-WC Type VCP-WG Type VCPW-SE

* Refer to page 11 for specific breaker ratings. UL listing, 3-cycle ratings, undervoltage release, and second shunt trip are optionally available.
6 7
The Worlds Most Complete
Line of Medium Voltage
Vacuum Circuit Breakers

CIRCUIT BREAKERS
MEDIUM VOLTAGE VACUUM
Type VCP-W Vacuum Circuit Breakers The leading value-added modular
approach for assembling metal-clad
ANSI 5/15 kV at 1200-3000 Amperes switchgear featuring Cutler-Hammer
250-1500 MVA, 60-95 kV BIL medium voltage vacuum circuit
IEC 3.6/17.5 kV at 630-2000 Amperes breakers, structures and accessories.
25-40 kA, 40-95 kV BIL

OEM
SWITCHGEAR
COMPONENT
PRODUCTS

Breaker Type Voltage Class Insulation BIL Interrupting Ratings Continuous Current Application

VCPW-ND ANSI 5 kV 60 kV 250 MVA 1200A 26" Wide New Metal-Clad Switchgear
or Upgrades to Existing Airbreak Switchgear
IEC 3.6-7.2 kV 40-60 kV 25-31.5 kA 630-1250A
VCP-W ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A 36" Wide New Metal-Clad Switchgear
or Upgrades to Existing Switchgear
IEC 3.6-17.5 kV 40-95 kV 25-40 kA 630-2000A
VCPW-SE ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A 36" Wide Special Environment Metal-Clad
Switchgear Featuring Breakers with Cycloaliphatic
IEC 3.6-17.5 kV 40-95 kV 25-40 kA 630-2000A Epoxy Insulation for Harsh Industrial Environments
VCP-W ANSI 27 kV 125 kV 16-40 kA 600-2000A 36" Wide Metal-Clad Switchgear
or Upgrades to Existing Switchgear
IEC 24 kV 125 kV 16-25 kA 630-2000A
VCP-W ANSI 38 kV 170 kV 16-40 kA, 600-2500A 42" Wide Metal-Clad Switchgear
1500 MVA
VCP-W (Outdoor) ANSI 15.5 kV 110 kV 16-31.5 kA 600-1200A Outdoor Station Distribution Breakers
W-VAC IEC 3.6-17.5 kV 40-95 kV 16-40 kA 630-2000A 600-750 mm Wide IEC Medium Voltage Switchgear
W-VAC IEC 3.6-17.5 kV 40-95 kV 31.5-50 kA 2500-3150A 1000 mm Wide IEC Medium Voltage Switchgear
W-VAC IEC 36 kV 170 kV 16-31.5 kA 630-2000A 42" Wide IEC Metal-Clad Switchgear
DHP-VR ANSI 5-15 kV 60-95 kV 250-1000 MVA 1200-3000A DHP Metal-Clad Switchgear Technology Upgrades
with the DHP-VR Direct Roll-in Vacuum Replace-
ment Breakers from the Original Manufacturer
VCP-WR ANSI 5-15 kV 60-95 kV 250-1500 MVA 1200-3000A Modular Fixed Vacuum Circuit Breakers in 18", 20",
Series 18, 20, and 29 and 29" Widths for Conversions/Retrofits, Metal
Enclosed Switchgear and Mining Switchgear
VCP-WC ANSI 5-17.5kV 95kV 25-63kA 1200-3000A 36" wide Metal-Clad Switchgear
VCP-WG ANSI 5-15kV 95kV 50-63kA 1200-3000A 36" wide Metal-Clad Switchgear
VCP-T ANSI 5-15kV 95kV 16-25kA 800-1200A Smaller frame breaker
VCP-TR IEC 3.6-17.5kV 95kV 16-25kA 630-1250A Smaller frame breaker

Eaton Corporation 2003 EATON CORPORATION


Cutler-Hammer business unit
1000 Cherrington Parkway ALL RIGHTS RESERVED
Moon Township, PA 15108 PRINTED IN USA
United States
FORM NO. BR01301006E
tel: 1-800-525-2000
www.cutler-hammer.com SEPTEMBER 2003