A 6m fy 320 Mpa H2 4
= Lny/Lnx
hmin = (Lny(0,8+(Fy/1400)))/(36+9)
hmax = (Lny(0,8+(Fy/1400)))/(36)
Ly 7000 fy 320
Lx 2000
3.5
hmin 106.6667 diambil h= 120 mm
hmax 200 Untuk h Lantai dan Atap di buat sama
Qu Panel Atap
Qu Panel Lantai
BJ
100 kg/m^2
250 kg/m^2
536.56 kg/m^2
776.56 kg/m^2
Perencanaan Balok Komposit
MMAX POSITIF (kgm) LINTANG POSITIF (kg) NORMAL (kg)
ATAP LANTAI ATAP LANTAI ATAP LANTAI
7015.17 9203.48 10278.56 14387 4886.54 2472.48
ATAP LANTAI
13022.87 18149.13
Desain Balok
Data data
Profil 350x150
d 300 mm E 200000 Mpa Lbalok 7
bf 150 mm F'c 24 Mpa Lantar balok 6
h 263 mm Fy 320 Mpa
t 18.5 mm
tw 10 mm
rx 12.33 cm 123.3 mm
ry 3.26 cm 32.6 mm
Sx 847 cm3 847000 mm3
Sy 118 cm3 118000 mm3
Ix 12700 cm4 127000000 mm4
Iy 886 cm4 8860000 mm4
rT 4.03 cm 40.3 mm
q 65.52 kg/m 0.6552 N/mm
As 83.47 cm2 8347 mm2
J 720829.1667 mm4
Zx 954085 mm3
Kontrol Lendutan
dipakai nilai batas max = L/250 28 mm
atap lantai
= (5.q.l4)/(384.E.I) 13.65528694 19.40249822 mm
be = L/4 1750 mm
be = b 6000 mm
Sayap
b/t 4.054054 CEK Penampang Kompak
0,38*(E/FY)^0,5 9.5
maka a = (Fy*As)/(0,85*Fc'*be)
a = 74.81904762 mm < T. Pelat = 120 mm
Yc = t 120 mm
Y2 = Yc - 0,5*a 82.59048 mm
Mn = Fy*As*(Y2+0,5*d)
621258466 Nmm
Mn = 559132619 Nmm
qu 7.06104 N/mm
Mupelat 43.24887 Nmm
Mnnetto = Mn - Mupelat Mubeban ATAP
559132576 Nmm 559.1325757 KNm LANTAI
Vn = *0,6*Fy*Aw*Cv
1602624 N Vukapasitas 93.1887626 KN
1602.624 KN Vubeban ATAP 102.7856
cek Vn>Vu LANTAI 143.87
ok
y0 Ayi/Ai
113.7904686 mm
Itr = I0+Ai*(y0-yi)2
156088000 + 273815001 =
36.30772512 % 63.6922749 %
Pada AISC 2010 dijelaskan bahwa tdak prakts membuat analisis akurat kekakuan balok
komposit. Pengukuran lendutan jangka pendek memperlihatkan bahwa momen inersia efektf
adalah sekitar 15%-30% lebih rendah dari teori elasts, inersia ekuivalen sama nilainya dengan
Itr . Oleh sebab itu agar hasilnya realistk maka I ef = 0,75Iekuiv
Pada AISC 2010 dijelaskan bahwa tdak prakts membuat analisis akurat kekakuan balok
komposit. Pengukuran lendutan jangka pendek memperlihatkan bahwa momen inersia efektf
adalah sekitar 15%-30% lebih rendah dari teori elasts, inersia ekuivalen sama nilainya dengan
Itr . Oleh sebab itu agar hasilnya realistk maka I ef = 0,75Iekuiv
Ief = 0,75*Itr
322427251 mm4
376.56 kg/m2
qD = 431.8335 kg/m 4.318334694 N/mm
D = 5.315125 mm aksi non komposit (beban hidup tdak diperhitungkan)
Konsekuensi dipilihnya strategu unshored-construction, maka balok harus dievaluasi juga sebagai struktur non-komp
Untuk itu diperhitungkan beban hidup konstruksi dan dicek terhadap momen nominal dengan faktor modifikasi.
atap lantai
Mu 70151700 92034800 Nmm
70.1517 92.0348 KNm
cek Lb terhadap Lp Lr
Lb 3.5 m dipasang penambatan lateral ditengah bentang
Lp 1434.4 mm
1.4344 m
Lr 5501.544 mm
5.501544 m
cek Lp<Lb<Lr
Mn = Cb*(*Mp-BF(Lb-Lp)) <= Mp
Mn 208424252.8 Nmm
208.4242528 KNm
Mp 274776480 Nmm
274.77648 KNm
atap Lantai
cek apakah Mn>Mu Ok Ok
L = 12.90817084 mm
TOTAL = D+L
18.2233 CEK TERHADAP BATAS LENDUTAN LENDUTAN OK
creep/rangkak
Ee = Eci/(1+vt)
vt = (t0,6/(10+t0,6))*vu
be/n = 61.87669882 mm
propert elasts transformasi
No b (mm) h (mm) Ai (mm2) yi (mm) Ai.yi (mm3) I0 (mm4)
1 61.8767 250 15469.1747 125 1933646.84 80568618.2496
2 Profil balok 8347 270 2253690 127000000
23816.1747 4187336.84 207568618.25
y0 Ayi/Ai
175.8190343 mm
Itr = I0+Ai*(y0-yi)2
207568618.2 + 205622391 =
50.23551181 % 49.7644882 %
Shrinkage/susut
Psh 967058.5505 N
967.0585505 KN
e 53.79046859 mm
sh = 3.855523293 mm
Asa 283.6429 mm
Rg 1
Rp 0.75
Qn = 105426.4 N 105.4263609 KN
nilai batas 110620.7 N 110.6207143 KN
CEK OK, maka nilai QN yang menentukan
T = V' = 2671040 N
2671.04 KN
19.512195122
70.1517 92.0348
Profil badan kompak maka penampang plasts!
70.1517 KNm
92.0348 KNm
KN
KN
Ai.(y0-yi)2 (mm4)
70136367.7544 25.61451 %
203678633.565 74.38549 %
273815001.32 100 %
429903001.32 mm4
100 %
413191009.219 mm4
100 %
4.375
269 mm
Dimensi 250000 mm2 Beban beton sebelum mengeras
Pu 69371.89 Kg 693.7189 KN Lkolom das 17041.311 N 17.04131
MA 10667.94 Kgm 106.6794 KNm Lkolom lan 136.878 N 0.136878
MB 8880 Kgm 88.8 KNm
Data profil
d 400 mm E 200000 MPa Lkolom dasar 3m
bf 400 mm F'c 24 MPa Lkolom lantai 4m
h 358 mm Fy 320 MPa
t 21 mm Ec 23025.2 MPa
tw 13 mm
rx 17.45 cm 174.5 mm
ry 10.12 cm 101.2 mm
Sx 3330 cm3 3330000 mm3
Sy 120 cm3 120000 mm3
Ix 66600 cm4 666000000 mm4
Iy 22400 cm4 224000000 mm4
rT 11.05 cm 110.5 mm
q 171.68 kg/m 1.7168 N/mm
As 218.7 cm2 21870 mm2
J 2731775 mm4
Zx 3600133 mm3 1152042560 1152.043
Badan
h/tw < 1,49*(E/Fy)0,5 cek Web tak langsing
27.53846 37.25
Sayap
b/t < 0,56*(E/Fy)0,5 cek Flens tak langsing
9.52381 < 14
K L rx ry KL/rx KL/ry
K. Dasar 0.5 3000 174.5 101.2 8.595989 14.822134 Yang menentukan adalah sum
K. Lantai 0.5 4000 174.5 101.2 11.46132 19.762846
c. Cek terhadap nilai batas
d. Menghitung Fcr
cek terhadap Pu
K. Dasar Ok
K. Lantai Ok
Menentukan w
c CEK
K dasar 1.433051 w=1,25ac^2
K lantai 1.910735 w=1,25ac^2
w
K dasar 2.567045
K lantai 4.563636
menghitung fcr
fcr
K dasar 200.1147 Mpa
K lantai 112.5645 Mpa
Nn Nu
K dasar 3720033 N 3720.03271 KN 710.7602 KN
K lantai 3720033 N 3720.03271 KN 693.8558 KN
g. Menghitung Mn
Karena pada saat pengecekkan kolom, kolom tak termasuk tak langsing maka tdak perlu dilakukan pembesaran momen
Nu Nn
K dasar 710.7602 3720.03271 Nu/Nn 0.191063
K lantai 693.8558 3720.03271 Nu/Nn 0.186519
0.19775472 <= 1
Ok!!!!
KN Vu 4887.34 48873.4 N
KN
Rn Tumpu Pelat
Rn 195624 N
195.624 KN
1. DATA SAMBUNGAN
1.1. BAUT
a x
h
a
a
a/2 h-x
b b' 3
MPa 326
mm
mm
bh
baris
MPa
MPa
mm
mm
bh
mm
mm
mm
mm
pers. (1)
pers. (2)
pers. (3)
MPa
MPa
MPa
MPa
MPa
N
N
mm2
N
N
N
mm2
N
N
N
mm
mm
MPa
N
N
MPa
MPa
MPa
MPa
N
N
MPa
MPa
PERHITUNGAN SAMBUNGAN AKSIAL LENTUR DAN GESER
1. DATA SAMBUNGAN
ht a 0.95 ht a
h
Pu
f f
Mu B I
f f
Vu
L
J
1. DATA TUMPUAN
2. EKSENTRISITAS BEBAN
Eksentrisitas beban,
ht e = Mu / Pu = 47.97 mm
h
L/6= 90.00 mm
Pu
e<L/6
f e
ec h = ht - tf = 379 mm
et = f + h / 2 = 410 mm
ec = f - h / 2 = 30.5 mm
t
et Y/3
Pu + Pt
Y
Pt
L
Y/3
Pu + Pt
Y
Pt
L
a 0.95 ht a
B I
f f
L
J
4. KONTROL DIMENSI PLAT TUMPUAN
B I
B I