Anda di halaman 1dari 38

electRonic Fuel

manaGement sYstems

SiteSentinel iSite

SiteSentinel iTouch

but Remain in complete contRol, theRes opW.

From the most innovative tank gauging systems in the world to the

most reliable and accurate fuel control systems, there is no better or

more comprehensive solution on the market today to ensure that

you know exactly how much fuel you have and where it is going.

When it comes to complete fuel accountability, unparalleled Fuel Control Systems

protection against theft and total reconciliation,

OPW Fuel Management Systems is

Leading the Way in keeping you and your

assets covered both coming and going!

Phoenix Software

1-800-422-2525 | www.opwglobal.com

Leading The Way In Fueling


Innovation Worldwide

309
OPW Fuel
OPW FUEL MANAGEMENT SYSTEMS

Management
Systems
OPW Fuel Management Systems
delivers product excellence and a broad
line of fuel control and tank gauge
solutions to retail and commercial
fueling operations worldwide. OPW
Fuel Management Systems is part of
OPW Fueling Components, the global
leader in fueling solutions, offering
the most comprehensive line of fueling
equipment and global support in the
world for over 40 years.

NOTE: See OPW Fuel Management Systems Website at www.opwglobal.com for detailed
310 product literature, manuals and sales representative contact information for your area.
Electronic Fuel Management Systems

OPW FUEL MANAGEMENT SYSTEMS


uT
 ank Gauges
SiteSentinel iSite Console................... 314 - 315
The VSmart Module ......................................... 316 - 317
SiteSentinel iTouch Console ............ 318 - 319
924B Probe................................................................ 320 - 321
AST Flex Probe....................................................... 322 - 323
IntelliSense Sensor ....................................... 324 - 325
Density Measurement Sensor .............. 326 - 327

uF
 uel Controls
PetroLink Fuel Control System ......... 330 - 331
FIT500......................................................................... 332 - 333
C/OPT.......................................................................... 334 - 335
K800 Hybrid ......................................................... 336 - 337
K800 ............................................................................. 338 - 339
Phoenix..................................................................... 340 - 341
AFC ................................................................................ 342 - 343
Keegard .................................................................................... 344
Pulsers ........................................................................................... 345

Setting the industry


standard in retail and
commercial fueling
solutions worldwide
since 1892.

Leading The Way in Fueling Innovation Worldwide 311


311
SITESENTINEL ISITE

3 BeSt-in-ClaSS
line leak
DeteCtiOn
2 BeSt-in-ClaSS
BeSt-in-ClaSS SiteSentinel iSite VSMart 4 BeSt-in-ClaSS
1
Or itOuCh COnSOle MODule DenSity
MeaSureMent

7 BeSt-in-ClaSS
924B MagnetOStriCtiVe
PrOBe

6 BeSt-in-ClaSS
Mag SuMP
SenSOrS

5 BeSt-in-ClaSS 8 BeSt-in-ClaSS
intelliSenSe aSt FlexiBle
SMart SenSOrS PrOBe

9 k800 hyBriD, C/OPt & Fit500


Fuel COntrOl SySteMS

8
10 FSC3000 Fuel Site COntrOller
inSiDe the Fuel iSlanD terMinal
1

15 Color LCD 10
9
Touchscreen
Display

One-Wire
connection
or optional Up to 4 LLD sensors can
wireless be daisy-chained together
communication per IS Barrier
3

6 6

Up to 16 IntelliSense
Smart Sensors can be
daisy-chained together
per IS Barrier
Up to 4 probes
5 7
can be daisy-
chained together
per IS Barrier

Up to 4 Mag Sump Sensors 4


can be daisy-chained together
per IS Barrier

11 PhOenix SOFtWare

312
OPW Tank Gauges

OPW TANK GAUGES


SiteSentinel iSite Console ............................. 314 - 315
The VSmart Module......................................................... 316 - 317
SiteSentinel iTouch Console..................... 318 - 319
924B Probe ..................................................................................... 320 - 321
AST Flex Probe.......................................................................... 322 - 323
IntelliSense Sensor....................................................... 324 - 325
Density Measurement Sensor ....................... 326 - 327

Setting the industry


standard in retail and
commercial fueling
solutions worldwide
since 1892.

Leading The Way in Fueling Innovation Worldwide 313


313
SiteSentinel iSite iSite Console Components
SITESENTINEL ISITE CONSOLE

Console
Part of the

The SiteSentinel iSite provides


complete tank monitoring, inventory
management and environmental
family of products
compliance that incorporates the latest
Windows-based technology to allow
users to view data remotely from
anywhere in the world, or via a 15" color
LCD touch screen display at the site.
The SiteSentinel iSite lowers
installation costs by allowing probes,
Features
sensors and leak detection devices to
be connected via its VSmart module Convenience u Provides real-time, accurate inventory
for wireless or single wire interface to The SiteSentinel iSite console information
the console. In addition, all devices are can be accessed from anywhere there is u Displays gross and/or net-corrected
automatically detected and configured internet access: back office, front of store, tank volume, product level, water level
by the push of a button, making it the wall mount, desktop, at home or thousands and temperature for individual tanks
easiest ATG system in the industry to of miles away its your choice.
u Certified automatic or on-demand leak
install, configure and use.
B detection capabilities meet and/or
U
S
intuitive exceed U.S. Environmental Protection
SiteSentinel iSite is one of Agency regulatory requirements
the easiest tank gauges to use, requiring
u International user-friendly icons
the least amount of training and menu
B
MIL STD - 1472F
U
S
navigation for accessing critical data.
u Monitors up to 256 probes and/or
Connectivity 1,024 devices
The SiteSentinel iSiteconsole u One system handles a mix of horizontal
is the only console designed for connectiv- and vertical tanks utilizing rigid
ity now and in the future. Available ports and flexible magnetostrictive probe
include: Ethernet, USB, Serial (RS232, technologies
RS485), modem communication ports.
u Large, color touchscreen display gives
B one-touch access to real-time inventory
Savings
S

data, delivery status, alarm conditions,


U

SiteSentinel iSite, when used and leak detection information, all


with IntelliSense Smart Sensors and/or accessible from a single cockpit view
wireless option, results in the least amount
u USB and shared network printer
of conduit and wiring for installations.
interface

B NOTE: See OPW Fuel Management Systems


U
S
Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
314
additional Features Specifications

SITESENTINEL ISITE CONSOLE


u SQL database, FTP available for u System provides 2 output and 2 input
Dimensions: 13" W, 16" H, 6" D,
report data contact sets to connect external devices
(330 mm x 406 mm x 152 mm)
u An optional advanced leak-testing like overfill alarms
Weight: 20 lbs. (9.07 kg)
technology, SLD (Segmented Leak u Available output module provides multi-
Detection), provides continuous automatic purpose relays, which can be used Operating Temperature: 32 F to 122 F
in-tank leak-detection operation, with no for outputs such as overfill alarms or (0 C to 50 C)
need to schedule test times sensor alarms Humidity: Non-Condensing (Max 95%)
u Programmable Automatic Leak u Internal power supply automatically Typical Mounting Location: Indoor,
Detection (ALD) can be set to perform switches between 120- and 240-volt Non-Hazardous Area
daily, weekly, monthly, and annually power systems
Power Requirements: 120/240 VAC
required static leak tests when the u Density measurement capability can 10%, 50/60 Hz.
system detects a quiet time be used to more accurately calculate
Communication Ports: 2 x Ethernet,
u System provides programmable net-corrected volumes and leak test
2 x 485, 4 x 232, 2 x USB, 2 internal USB,
correction factors for restrapping tanks performance
modem and wireless
(450 points) consistent with the u System can send text messages to
iTouch console Up to 16 relays max., 4 output relays per
cell phone or automatically fax and/or
module, 4 modules per system
u Can be configured to meet localized e-mail alarms and events
settings (date/time formats and u Reconciliation
Metric/English units)
u Address book
u Software is downloadable for
u Schedule reports to run at specific
easy updates
times, automatically
u System interfaces with many
u Non-volatile memory for event storage
POS devices
up to 10 years
u Provides 4 soft programmable RS-232
u Compliance calendar Tank Threshold Screen
communication ports
u Provides 2 soft programmable RS-485
communication ports

leak test Certification


u EPA Continuous Leak Test (SLD) u EPA Static Leak Test Certified:
Certified: 35,000-gallon tank 20,000-gallon tank (76,000 liters)
(132,475 liters) u 0.2 gph (0.76 lph) Static Leak Test
u EPA Continuous Leak Test (SLD) 99.3% Pd, 0.07% Pfa
Certified: Manifold tank configuration, 98.18% Pd, 1.82 Pfa, time test 30 hours Compliance Calendar
two tanks equaling the sum of
96.5%, 3.5% time test 1.5 hours
35,000-gallon tank (132,475 liters)
u 0.1 gph (0.38 lph) Static Leak Test
u 0.2 gph (0.76 lph) Continuous Leak
97.25% Pd, 1.25% Pfa
Test (SLD) 99.1% Pd, .9% Pfa

315
the VSmart Module the VSmart Module Components
THE VSMART MODULE

VSmart module provides for wireless


or single-wire interface of all system
components probes, sensors, line
leak devices to the SiteSentinel
iSite console for ease of installation. Part of the
All devices are connected directly to the
VSmart module, making installation quick
and easy. Using exclusive, proprietary
IntelliSense Technology for probes family of products
and sensors, the VSmart automatically
detects the type of device connected and the VSmart Module Features
sends the device information directly from
the VSmart module to the SiteSentinel Wireless installation
iSite console!
The VSmarts single wireless Interfaces probes and sensors
The VSmart Module with a NEMA
radio antenna is installed above ground to the SiteSentinel iSite console by
4-rated enclosure can be located
and does not use batteries,
B ensuring a daisy-chaining through a single
outside near the tank area, reducing or U
S

higher power signal and the best possible IS channel.


eliminating direct wiring runs back to
connection available.
the SiteSentinel iSite console.
B
Savings
S
U
automated Lowers installation costs by
The VSmart can automatically eliminating multiple wiring (home runs)
detect the presence of attached devices for probes or sensors, back to the
including
S
B probes, sensors and density console in the building.
U
floats, on any IS channel.

B
S
U

listings and
Certifications

316
the VSmart Module Specifications

THE VSMART MODULE


u NEMA 4-rated VSmart enclosure u Probe inputs intrinsically safe Dimensions: 11.3" W, 5.6" H, 5.8" D,
magnetostrictive 1 or 2 floats (28.7 cm x 14.2 cm x 14.7 cm)
u NEMA 4-rated wireless modem
u Operating Temperature: -40 F to UL, NEMA 4-rated VSmart enclosure
u Number of Probes: Up to 32 924B
probes and/or 8 flex probes per VSmart 158 F (-40 C to 70 C) RS-485 Twisted pair - 5,000 feet
module, up to 8 VSmart Modules per u Data Cable: 250' (75 m) or less use Ethernet (CAT5) - 500 feet
SiteSentinel iSite Console Belden 88760, from 251'1,000'
Wireless - Recommended up to 1,500 feet
(77 m to 304 m) use Belden 9182
maximum with free line of sight.
Power Requirements: 120/240 VAC
10%, 50/60 Hz.

VSmart Module
VSmart Module Capabilities
2 4-channel IS Modules per VSmart Module
Maximum of 8 IS Channels per VSmart Module
Maximum of 8 VSmart Modules per console
Maximum of 8 AST Flex Probes per VSmart Module
Maximum of 32 model 924B Probes per VSmart Module
Maximum of 128 Active or Passive Sensors per VSmart Module
(Intellisense Sensors)

1 2 3 4

IS

Up to 4 Multi-Drop Probes
OR
1 AST Flex Probe

Up to 4 LLD Sensors Up to 4 MAG Sump Sensors

Any combination of up to
16 IntelliSense Smart Sensors

317
SiteSentinel itouch itouch Console Components
SITESENTINEL ITOUCH CONSOLE

Console Part of the

OPWs SiteSentinel iTouch is a multi-


function, high-quality tank-monitoring
system that provides real-time, accurate family of products
inventory information for up to 16
underground storage tanks. The enhanced
performance of the SiteSentinel iTouch
improves data processing, allows for
future system expansion and can be
customized to meet each users needs.

System Features
applications
Compliance u Graphic touchscreen display uses
u Provides real-time, accurate inventory international user-friendly icons
The certified leak detection
information
meets or exceeds U.S. EPA regulatory u Monitors up to 16 probes and/or
u Displays gross- or net-corrected tank requirements, protecting the environment sensors that can be connected in
volume, product level, water level, in and around storage tanks. any combination
and temperature for individual tanks
u Touchscreen provides one-touch
u Available output module provides easy-to-use access to real-time inventory data,
multi-purpose relays, which can The graphic display gives delivery status, alarm conditions
be used for outputs such as one-touch access to real-time inventory and leak detection information
overfill or sensor alarms data, delivery status, alarm conditions
u SiteConnect software, a Windows-
and leak-detection information.
u Third-Party certified automatic or U
S
B
based configuration utility, makes site
on-demand leak detection meets configuration easy
automated
and/or exceeds U.S. Environmental u Compatible with SmartTalk software
Programmable Automatic Leak
Protection Agency regulatory for enhanced business management
Detection (ALD) can be set to perform
requirements and compliance reporting
routine required leak tests. The system
can automatically e-mail alarms u Automatic Leak Detection (ALD)
and events. can be programmed to perform
daily, weekly, monthly and
Connectivity annually required leak tests. Once
Monitors up to 16 probes or programmed, the iTouch system will
sensors that can be connected in any automatically look for the appropriate
combination. Reports can be printed on quiet time over the course of the day
to conduct a static leak test without
the external printer or from SiteConnect
operator intervention.
on the PC printer.
u System provides over 400
U
S
B
programmable correction factors
guaranteeing the most accurate
tank chart

listings and
Certifications

318
itouch additional System Features Power requirements

SITESENTINEL ITOUCH CONSOLE


u Meets weights and measures standards Input Power: 100-250 VAC, 50/60 Hz, 0.5 A
System alarms
in countries where required. Input Contact: 12 VDC, 40 mA max.
u Low-Low Product (shutdown) Output Contact: 30 V-AC/DC, 2A
u Supports international time, date and u Low Product (reorder) Output Module Contact: 2A @ 120/240
decimal formats u High Product (alarm) AC, 2A @ 24VDC
u Software is downloadable (Flash RAM) u High-High Product (overfill) PC Software: SiteConnect on CD-ROM
for easy updates u High Water (warning) is included
u High-High Water (alarm) Minimum PC Requirements: Pentium
u System interfaces with most POS
u Sensor processor, 32 MB RAM, 20 MB available
devices, supporting standard industry hard disk space, recommended PC screen
u Leak Detection
protocols resolution (800 x 600), Windows 98,
reports Windows NT (version SP4 and above),
u PV4 POS protocol can be modified to
Windows 2000, Windows XP,
meet the needs and requirements of u System uses international icons to
Windows Vista
the user. create Inventory, Delivery, System
Printer: System-powered, graphics
Alarm, and Leak Test reports 40-column thermal printer includes wall-
u Provides 3 dedicated RS-232 serial
communication ports u Reports in Metric or English units mounted bracket and a 6 ft (1.8 m) cable.
of measurement Intrinsically Safe Barrier is ATEX approved.
u System provides 1 output and 1 input
to connect external devices like overfill u Reports can be printed on the external SiteConnect Software
alarms and line leak detectors printer or from SiteConnect on the u Easy to set up and configure your entire
PC printer site from your PC
u Internal power supply automatically
switches between 120- and 240-volt Probes and Sensors u Configure your system to monitor the
quality of your fuel deliveries (density
power systems u All probes and sensors are third party measurement sensor is required)
u Output module (up to 2 modules max.) certified to meet and/or exceed U.S.
u Refresh feature allows you to stay
adds 4 output relays per module to Environmental Protection Agency current with product inventory levels at
control external devices regulatory requirements a glance. Inventory changes in your
tanks are dynamically updated.
u Density measurement ensures that you Management reports
receive the expected fuel quality with u View and print inventory, delivery,
u Inventory, Delivery, Alarm and Leak alarm, leak test, set-up and system
each delivery
Reports are available at a touch diagnostic reports directly from your PC
u System can automatically e-mail alarms
u Reports can be configured to meet u Address book keeps emergency e-mail
and events via TCP/IP and fax numbers organized
localized settings (date/time formats
u Fax-out capability with external modem and Metric/English units) u POS protocols selectable through
u TCP/IP interface allows easy pull-down menus
Specifications
communications using your local u Available in different languages.
Operating Temperature Range: Pull-down menu allows you to
network
14 F to 122 F (-10 C to 50 C) easily select languages.
u Increased memory size allows for Printer Operating Temperature Range:
u Provides the ability to manage fuel
future system expansion 32 F to 104 F (0 C to 40 C) inventory locally or remotely from
Normal Cabinet Dimensions: a centralized office
9.3" H x 12.3" W x 5.2" D u Multiple password levels provide
(23.5 cm H x 31.1 cm W x 13.3 cm D) security for data access

319
924B Magnetostrictive
924B MAGNETOSTRICTIVE PROBE

Probe

Trouble-free accuracy with proven


magnetostrictive probe technology.
Highly accurate, easy-to-use
performance for inventory Part of the
management and in-tank leak
detection. Unlike competitive probes
that have to be upgraded to handle
different liquids, the 924B Probe comes family of products
standard in stainless steel and can be
used with most petroleum products. System Features
The probe also measures water
level, providing information to accurate
Five-point temperature sensing u All stainless steel construction
ensure product quality.
element provides exact temperature
u Welded construction eliminates
compensation for product volume
potential leak points
contraction and expansion, allowing for
accurate inventory management and in-tank u Level 1 probe - 1 probe for all
leak detection. applications

u Easy Installation: Can daisy-chain


easy-to-use up to 4 probes on one IS channel
Automatically transmits probe (SiteSentinel iSite only) which
profile to SiteSentinel iSite on start-up, makes installation easier and
eliminating programming errors. less time consuming

installation u Optional Density Float provides


Adjustable probe head a measure of even the slightest
centering disks provide a tight fit inside changes in product quality within
risers with diameters ranging from 2" the specified API density range.
(5.1 cm) to 4" (10.2 cm).

Compliance
Supports programmable
ALD (Automatic Leak Detection) to
perform daily, weekly, monthly and
annually required leak tests as well as
Segmented Leak Detection (SLD) for
24-hour continuous monthly leak tests
B
U
S
(for SiteSentinel iSite only).

listings and
Certifications
1180

320
Compliance

924B MAGNETOSTRICTIVE PROBE


u The system is certified to meet or exceed U.S. Environmental
Probe Specifications
Protection Agencys performance standards for 0.1 gph (0.38 Type: Magnetostrictive/float
lph) volumetric tank tightness testing and 0.2 gph (0.76 lph) Material: Stainless steel body, aluminum cap
monthly monitoring Location: Hazardous, Class 1, Division 1, Group D
u Supports ALD with SiteSentinel ATG family and supports SLD Temperature: 5 RTDs
with SiteSentinel iSite Temperature Range: -40 F to 140 F (-40 C to 60 C)
Data Cable: 1,000' (300 m) Belden 88760
Magnetostrictive Probe Data
500' (150 m) max. Belden 88761
u Measures product level changes to a resolution of
0.0005" (0.0127 mm)
Probe length
u Measures product temperature changes to Part No. Description
a resolution of 0.001 F (0.0005 C) 30-B053 53" (135 cm)
u Measures water level changes to a resolution of 30-B069 69" (175 cm)
0.01" (0.254 mm) 30-B077 77" (196 cm)
u Linearity over the entire probe length is 0.04" (1 mm) 30-B089 89" (226 cm)
30-B101 101" (257 cm)
leak test Performance
30-B105 105" (267 cm)
u Third-party certified to meet U.S. EPA leak detection 30-B113 113" (287 cm)
requirements (static and SLD) in tanks up to 20,000 gallons
30-B125 125" (317 cm)
(76,000 liters)
30-B137 137" (350 cm)
u 0.2 gph (0.76 lph) Static Leak Test: 98.18% Pd, 1.82% Pfa
30-B149 149" (376 cm)
u 0.1 gph (0.38 lph) Static Leak Test: 96.5% Pd, 3.5% Pfa
u 0.2 gph (0.76 lph) Automatic Leak Detection (ALD) Probe Float kits
Part No. Description
u 0.1 gph (0.38 lph) Automatic Leak Detection (ALD)
30-1509-02 2" (5.1 cm) Gas/Water Nitrophyl Float Kit
u Third-party certified to meet US EPA leak detection 30-1509-01 2" (5.1 cm) Diesel/Water Nitrophyl Float Kit
requirements (SLD) in tanks up to 35,000 gallons
30-3232 2" (5.1 cm) Density Measurement Kit
(132,475 liters)
30-1508-02 4" (10.2 cm) Gas/Water Nitrophyl Float Kit
u 0.2 gph (0.76 lph) Continuous Leak Test (SLD), 99.1% Pd,
0.9% Pfa Certified Probe 35,000-gallon tank (132,475 liters) 30-1508-01 4" (10.2 cm) Diesel/Water Nitrophyl Float Kit
4" Float Kit required for SLD feature
Stainless steel floats available upon request
Note: No leak testing available with stainless steel floats

GROUND LEVEL GROUND LEVEL

6 in. (15 cm) 20 in. 6 in. (15 cm) 20 in.


minimum (50 cm) minimum (50 cm)
Standard Riser Standard Riser
4 in. (10 cm) inside diameter 4 in. (10 cm) inside diameter
13 in. (33 cm) 13 in. (33 cm)

MANHOLE HEIGHT

TANK PROBE TANK PROBE


DIAMETER LENGTH DIAMETER LENGTH

TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH
* (Top of Tank to Top of Manhole Cover) * (Top of Tank to Top of Manhole Cover)

321
SiteSentinel iSite aSt Flex Probe Components
SITESENTINEL ISITE AST FLEX PROBE

aSt Flex Probe Part of the

Until now, monitoring of products in


above ground storage tanks has been
inaccurate at best. Many AST tank- family of products
gauging devices are available, but none
have the precision and accuracy of
OPWs SiteSentinel iSite.
The 7100V series flexible probe,
using field proven magnetostrictive
technology, allows greater precision
and reliability. This probe is ideal for aSt Flex Probe Features
liquid level monitoring of product and
water levels in a wide variety of liquids integrated installation
in above ground storage tanks, including All probe electronics are The flexible PVDF probe
gasoline, diesel, ethanol, biodiesel, integrated into the sensing tube, eliminating comes coiled with a threaded fitting on
lubricants and some chemicals. the bulky enclosure at the top of the probe the end of the probe, which allows for
and offering greater options for installation easy installation.
and mounting in above ground
storage tanks. innovative
B
U
S
OPWs new water float can
accurate detect a minimum of 2-1/2" of water in the
OPWs NEW SiteSentinel iSite bottom of a tank, ensuring product quality.
B
uses proven magnetostrictive technology
S
U
that accurately measures product level
changes to a resolution of .010".

B
S
U

B
S
U

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
322
Probe length availability Specifications

SITESENTINEL ISITE AST FLEX PROBE


The flexible AST magnetostrictive probe Input Voltage: 23-28 VDC
is available in lengths from 24" to 600" Tank Probe: Flexible PVDF to a max.
Reference the following for ordering of 50' (15.24 m)
information:
Enclosure: Material PVDF
Resolution: 0.010" Inventory Mode
Linearity: +/- 0.01% of full scale,
+/- 0.010" (.254 mm), whichever is greater

u 193" (16') to 216" (18') 490 cm (4.84 m) to 548 cm (5.45 m) Repeatability: +/- 0.001% of full scale,
+/- 0.00025" (.00635 mm), whichever
u 217" (18') to 240" (20') 551 cm (5.45 m) to 609 cm (6.06 m)
is greater
u 241" (20') to 264" (22') 612 cm (6.06 m) to 670 cm (6.66 m)
Temperature Accuracy: Absolute +/- 2 F
u 265" (22') to 288" (24') 673cm (6.66 m) to 731 cm (7.27 m) (1.11 C)
u 289" (24') to 312" (26') 734 cm (7.27 m) to 792 cm (7.87 m) Temperature Measurement Resolution:
u 313" (26') to 336" (28') 795 cm (7.87 m) to 853 cm (8.48 m) +/- 0.01 F (.02 C)

u 337" (28') to 360" (30') 855 cm (8.48 m) to 914 cm (9.09 m) Temperature Sensing Range: -40 F to
+150 F (-40 C to +65 C)
u 361" (30') to 384" (32') 916 cm (9.09 m) to 975 cm (9.69 m)
Operating Temperature Range: -40 F to
u 385" (32') to 396" (33') 977 cm (9.69 m) to 1005 cm (10 m)
+160 F (-40 C to +71 C)
u 397" (33') to 408" (34') 1008 cm (10 m) to 1036 cm (10.3 m) Distance to VSmart Module: Up to 1,000'
u 409" (34') to 420" (35) 1038 cm (10.3 m) to 1066 cm (10.6 m) using twisted-pair wire
u 421" (35') to 432" (36') 1069 cm (10.6 m) to 1097 cm (10.9 m) Environment: NEMA 4
u 433" (36') to 444" (37') 1099 cm (10.9 m) to 1127 cm (11.21 m) Listings: UL, Intrinsically Safe

u 445" (37') to 456" (38') 1130 cm (11.21 m) to 1158 cm (11.51 m) Maximum Tank Capacity: 99,999,999
gallons (approx. 378,541,176 liters)
u 457" (38') to 468" (39') 1160 cm (11.51 m) to 1188 cm (11.81 m)
Water Float Liftoff: 2-1/2" (6.35 cm)
u 469" (39') to 480" (40') 1191 cm (11.81 m) to 1219 cm (12.12m)
at 70 F (21 C)
u 481" (40') to 492" (41') 1221 cm (12.12 m) to 1249 cm (12.42 m)
u 493" (41') to 504" (42') 1252 cm (12.42 m) to 1280 cm (12.72 m)
u 505" (42') to 516" (43') 1282 cm (12.72 m) to 1310 cm (13.03 m)
u 517" (43') to 528" (44') 1313 cm (13.03 m) to 1341 cm (13.33 m)

323
intelliSense intelliSense System Components
INTELLISENSE TECHNOLOGY

technology
Delivers the ability to monitor all areas
of the fuel site tank interstice, piping
sumps, STP containment sumps,
dispenser sumps/pans and monitoring
Part of the
wells. IntelliSense technology allows
for interfacing all sensors through a
single 3-core cable connection. This
propriety technology is designed so
family of products
that the SiteSentinel iSite controller,
regardless of the type or place of
installation, will know immediately
intelliSense Features Sensors
what type of sensor is connected and innovative Discriminating Dispenser Pan Sensor -
the model number, name and location. IntelliSense makes innovative provides the ability to detect a low and high
sensor technology even smarter by liquid level and distinguish whether the
fluid is water or hydrocarbons. Detection
communicating the connection status and
low Cost of installation of fuel or water will result in an alarm
sensor type to the SiteSentinel iSite.
condition at the console. Detection of a fuel
The SiteSentinel iSites IntelliSense
or high-water condition is useful to disable
technology enables sensors to be Maintenance dispenser power to ensure protection of the
daisy-chained together during IntelliSense technology and the environment. This feature assures that an
installation, eliminating a wiring SiteSentinel iSite System keep track of alarm is sounded if the cable to the sensor
home-run for each sensor back replaced sensors by recording the sensors breaks or if the sensor malfunctions.
to the console in the building. serial number, alongBwith the date and time Part Number: 30-0232-DH-10
S
of its replacement.U Application: Dispenser pans
Detects: Fuel, water high and low level
Compliance Differentiates: Fuel vs. water
OPW provides a full line of Product Detection: 1.25" (3.17 cm) fuel
discriminating and non-discriminating only - 1.25" (3.17 cm) fuel on water
sensors to monitor the environment of Operating Temp: -40 F to 150 F
(-40 C to 65 C)
a fueling facility.

Discriminating STP Sensor - provides the


Savings
ability to detect a low and high-liquid level
The IntelliSense technology
and distinguish whether the fluid is water or
allows sensors to be daisy-chained during hydrocarbons. Detection of fuel or water will
an installation, eliminating a wiring home- result in an alarm condition at the console.
run for each sensor. Detection of a fuel or high-water condition
is useful to disable STP power to ensure
protection of the environment. This feature
B
U
S
assures that an alarm is sounded if
the cable to the sensor breaks or if the
sensor malfunctions.

listings and
Certifications
1180

324
Sensors (continued)

INTELLISENSE TECHNOLOGY
Part Number: 30-0232-DH-20 Hydrocarbon Vapor Sensor - designed and other containment locations. This
Application: STP Sumps for the early detection of the presence of feature assures that an alarm is sounded
Detects: Fuel, water high and low level hydrocarbon vapors in dry monitoring wells if the cable to the sensor breaks or if the
Differentiates: Fuel vs. water and interstitial spaces of a double-wall tank. sensor malfunctions.
Product Detection: 1.25" (3.17 cm) fuel The sensor is recoverable from detection Part Number: 30-0230-S
only - 1.25" (3.17 cm) fuel on water and will return to its normal state after Application: Interstitial space of
Operating Temp: -40 F to 150 F the vapors have dissipated. This feature double-wall tank
(-40 C to 65 C) assures that an alarm is sounded if the Detects: Fuel, water high and low level
cable to the sensor breaks or if the sensor Differentiates: Fuel vs. water
Discriminating Interstitial Sensor - Product Detection: 0.2" (0.50 cm) fuel
malfunctions.
utilizes a solid-state optical technology to only - 0.1" (0.25 cm) fuel on water
Part Number: 30-0235-V
detect the presence of fluid in the annular Operating Temp: -4 F to 176 F
Application: Dry monitoring wells, double
space of a tank and distinguish whether the (-20 C to 80 C)
wall tank interstice
fluid is water or hydrocarbons. Detection Differentiates: Fuel
of fuel or water will result in an alarm Discriminating Fuel/Water Monitoring
Product Detection: Hydrocarbon vapor
condition at the console. Detection of a fuel Well Sensor provides the ability to detect
Operating Temperature: -20 F to 104 F
or water condition in the tank interstice the presence of hydrocarbons floating on the
(-4 C to 40 C)
is useful to disable power to a STP and/ surface of water in a groundwater monitoring
or dispenser to ensure protection of the Interstitial Hydrocarbon Liquid with well. Its also able to detect when the water
environment. This feature assures that an Water Indicator - designed for use in a in the monitoring well has dropped below the
alarm is sounded if the cable to the sensor double-wall fiberglass tank to detect the sensor, making the detection of hydrocarbons
breaks or if the sensor malfunctions. presence of fluid and distinguish between no longer possible. The system will alarm
Part Number: 30-0236-LW fuel and water. This feature assures that an indicating that the monitoring well is dry
Application: Tank Interstice alarm is sounded if the cable to the sensor and environmental protection has been
Detects: Fuel, water high and low level breaks or if the sensor malfunctions. compromised. This sensor is used for
Differentiates: Fuel vs. water Part Number: 30-0234-HW-OL monitoring wells that are 6 to 20 feet deep.
Product Detection: Fuel or water 5/8" Application: Interstitial space of Part Numbers: 30-0234-HW-06 (6') (1.83 m),
Operating Temp: -40 F to 176 F double-wall fiberglass tank 30-024-MW-15 (15') (4.57 m),
(-40 C to 80 C) Differentiates: Fuel vs. water 30-0234-HW-20 (20') (6.09 m)
Product Detection: Requires min. 0.1" Application: Dispenser pans
Sump Sensor, Float Switch - designed to (0.25 cm) fuel to activate Detects: Fuel on water surface
detect the presence of fluid in a containment Operating Temp: -40 F to 150 F Differentiates: Fuel on water or when
sump/pan. Additionally, this feature assures (-40 C to 66 C) water drops below sensor
that an alarm is sounded if the cable to the
Product Detection: As little as a 0.1"
sensor breaks or if the sensor malfunctions. Liquid Only Interstitial Sensor - designed
(0.25 cm) fuel on water
Part Number: 30-0231-L to detect the presence of fluid in interstitial
Operating Temp:
Application: Dispenser pans/transitions space of a double-wall tank. The sensor,
Fuel -4 F to 122 F (-20 C to 50 C)
Detects: Fuel, water high and low level utilizing a float technology, activates on the
Water 32 F to 122F (0 C to 50 C)
Differentiates: Fuel vs. water presence of water or fuel and provides
Product Detection: Min. height 1-1/2" (3.81 cm) an alarm condition. Its constructed of a
Operating Temp: -40 F to 150 F chemically resistive non-metallic material,
(-40 C to 65 C) and can be used in sumps, dispenser pans

325
Density Measurement Density Measurement Sensor Components
DENSITY MEASUREMENT SENSOR

Sensor
Whether for a new or existing
installation, the Density Measurement
Sensor easily installs on the OPW
Magnetostrictive Probe. Combining
Part of the
industry-leading accuracy for water,
product and density measurement,
the SiteSentinel family Density
Measurement Sensor uses a
family of products
single magnetostrictive in-tank
probe assembly. intelliSense Features
The sensor continuously
accurate Features
measures the density of the fuel in
Uses float displacement, taking
the tank, providing a measure of even u Trouble-free design
advantage of the precision and accuracy
the smallest changes in product u Easy to retrofit to existing in-tank level
of the magnetostrictive probes level
quality within the API density range. probes (SiteSentinel 924B Probe)
measurement, which is capable of detecting
Fuel density reports can be displayed
changes of 0.0005" (0.0127 mm). u Density and level measurement
real-time on the SiteSentinel family
combined on 1 IS module position
of controllers or exported to an external
installation connection without the need for a
display. The density readings can
Density and level measurement dedicated input channel or
be configured to either nominal or
combined on 1 IS channel. additional wiring
temperature-corrected density.
S
B
u Fits through the same 2" (5 cm) opening
integration
U

in the tank thats used by the probe


As with every OPW tank gauge
component, the density sensor works u Economical solution to ensure
seamlessly with the SiteSentinel family continuous product quality
of products. u 4 probes (with density sensor) per
IS Channel (iSite only)
Savings u Dedicated density probes can support
Easily retrofitted to new and
3 density sensors per probe to ensure
existing in-tank SiteSentinel 924B level
product quality not available with
probes, providing an economical solution
level measurement
to ensure continuous product quality.

B
S
U

NOTE: See OPW Fuel Management Systems


Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
326
applications Magnetostrictive

DENSITY MEASUREMENT SENSOR


u Provide real-time, accurate density
Probe Data
information u Measures product level changes to a
u Displays density in kg/m3, g/cc or API resolution of 0.0005" (0.0127 mm)

u Applicable in petroleum products u Measures product temperature changes


designed for both underground (UST) to a resolution of 0.001 F (0.0005 C)
and above ground (AST) rigid u Measures water level changes to a
probe applications resolution of 0.01" (0.254 mm)
u Single sensor per standard in-tank u Linearity over the entire probe length
probe or multi-sensor for dedicated is 0.04" (1 mm)
triple-sensor density probe

Probe Specifications
Specifications Type: Magnetostrictive/float
Material: Nitrophyl, Delrin and stainless Material: All stainless steel construction,
steel spring aluminum cap
Resolution: 0.00004 g/cc Location: Hazardous, Class 1, Division 1,
Group D
Accuracy: 0.0025 g/cc
Probe Inputs: Intrinsically Safe
Density Range: 0.6 - 1.0 g/cc Probe Power Supply: 12 VDC Nominal
Operating Temperature: -40 F to 140 F Level Precision: 0.0005" (0.0127 cm)
(-40 C to 60 C) Level Accuracy: 0.04" (1 mm)
Temperature: 0.9 F ( 0.5 C)
Dimensions: 2" (diameter) x 11" (5 cm
Temperature: 5 RTDs
(diameter) x 28 cm)
Temperature Range: -40 F to 140 F
Number of Sensors Per iSite System: (-40 C to 60 C)
1 per probe or multi-sensor dedicated Data Cable: 1,000' (300 m) Belden 88760
probe equipped with 3 sensors. or 500' (150 m) max. Belden 88761
equipped with 3 sensors.

Proven Magnetostrictive
technology
u Supports extended operating
temperature range:
-40 F to 140 F (-40 C to 60 C)
u Compatible with gasoline, diesel and
other approved fluids

327
Petro Vend Fuel Control Systems
PETRO VEND FUEL CONTROL SYSTEMS

From the smallest fleet to the largest the type of fuel and quantities they fueling business and stay profitable.
petroleum marketing operation, Petro Vend need for complete security, accountability Other industry-leading options like RFID
has been providing effective solutions to and control. access, wireless data communication
meet your fuel control needs since 1961. Systems like The K800 Hybrid, C/OPT and powerful fuel management software
24-hour unattended fleet fueling systems and FIT500 accept nationwide fueling continue to make Petro Vend Fuel Control
like the K800 and AFC only allow network cards as well as local proprietary Systems the leader in 24-hour unattended
authorized users to access fuel, tracking network cards, allowing petroleum fuel management.
every transaction and restricting vehicles to marketers to grow their 24-hour unattended

Petro Vend Fuel Control Systems - Features Overview


K800/System2
Fuel Control PetroLink FIT500 C/OPT K800 AFC Keegard
Hybrid
System Model (page 330) (page 332) (page 334) (page 338) (page 342) (page 344)
(page 336)
Magnetic Stripe
Card Access

ChipKey Access
Proximity Card Access
PetroLink RFID Access
DuraKey Access


Keypad Access
Hose Capacity
32 32 32 32 16 8 1
Per System
Fuel Island Terminal
N/A 8 8 8 4 N/A
Capacity Per System

Maximum Transaction
2000 2000 2000 2000 1,800 999 N/A
Storage

Maximum Proprietary
(local network) Card/Key/ 64,000 64,000 64,000 64,000 10,000 10,000 30
User Capacity

Mileage Reasonability
Dual Card Accountability

Phoenix Fuel Management


Software Compatability

Commercial Fleet and


Trucking Card Acceptance

Bankcard
Acceptance

Wireless
Communication

Certifications ETL ETL US/C ETL US/C ETL US/C ETL US/C ETL UL

328
OPW Fuel Controls

OPW FUEL CONTROLS


Wireless Fuel Control System

PetroLink Fuel Control System...................... 330 - 331


FIT500 ..................................................................................................... 332 - 333
C/OPT ...................................................................................................... 334 - 335
K800 Hybrid.................................................................................. 336 - 337
K800 ........................................................................................................... 338 - 339
Phoenix ................................................................................................ 340 - 341
AFC .............................................................................................................. 342 - 343
Keegard ....................................................................................................................344
Pulsers ............................................................................................................................345

Setting the industry


standard in retail and
commercial fueling
solutions worldwide
since 1892.

Leading The Way in Fueling Innovation Worldwide 329


329
Petrolink Wireless
PETROLINK WIRELESS FUEL
CONTROL SYSTEM

Fuel Control System


PetroLink monitors and records WIRELESS COMMUNICATIONS
UNIT (WCU)
vehicle I.D., mileage and other
important fueling information solely FSC3000

through the use of RFID technology,


eliminating the need for wires or
PHOENIX
SOFTWARE

other equipment that can break or be


damaged, which often necessitates a
complete system replacement.
The PetroLink system is comprised
of four components, two of which are
installed on the vehicle with the other
two installed at the fueling location.

Provides the highest level of fuel


security, accountability and control Features & Benefits
No wires, special swivels or fuel u PetroLink will not allow fuel to be mounts around the vehicles fuel fill
authorization cards dispensed into any vehicle that is pipe. Adaptable to any vehicle, the
not equipped with a Wireless Tank transceiver cannot be removed
Accurately captures data without Transceiver Loop Antenna (TAG) without deactivation.
driver intervention
u Allows fleet owner or site operator to - Vehicle Tag Burner for burning
Pull up, fill up and go!
have accurate, real-time vehicle data (creating) code on tags
without needing to rely on the driver/ - GPTC Technicians Console
operators input for burning (creating) code on
u Vehicle operators no longer need to vehicle tags and for programming
carry cards and fobs, or remember vehicle meters
access codes, reducing the chance for u Vehicle Meter (VM) - installed on
lost equipment or human error the vehicle, and reads the vehicles
odometer and transmits the mileage
u Vehicle and driver information is easily and/or engine hours to the Wireless
reconcilable Communication Unit. Available meter
connections include:
u The PetroLink system needs only
seconds to begin operating once - Wired connections using
vehicle and driver are authorized a VSS signal, Universal Vehicle
Speed Sensor or Tachnograph
u PetroLink is a fool-proof way to
- OBD-II connection
prevent high-cost cases of fuel theft
u Wireless Communication Unit
The PetroLink system is comprised of (WCU) - records the data from the
four components, two of which are installed nozzle antenna and vehicle meter, and
on the vehicle with the other two installed at transmits it to the fueling locations
the fueling location. Those include: Fuel Site Controller (FSC3000). The
WCU is compatible with OPW FMS
u Wireless Tank Transceiver Loop Phoenix fuel-management software.
Antenna (TAG) - this unique design

NOTE: See OPW Fuel Management Systems


Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
330
u Nozzle Antenna (Reader) - a
Petrolink:

PETROLINK WIRELESS FUEL


CONTROL SYSTEM
battery-operated, wireless transceiver
that is mounted on the fueling nozzle. Illustration A easy installation
This antenna reads the vehicles RFID WIRELESS

tag and transmits the information to STEP 1: Install Wireless


COMMUNICATIONS UNIT

the WCU. Communications Unit (WCU)


FSC3000

- Nozzle-handle insulator
STEP 2: Install antenna(s) on OPW
PHOENIX

(colors available)
SOFTWARE

nozzle(s) (Reader)
- Fits standard OPW Nozzles

STEP 3: Install pre-programmed


how it Works: wireless PetroLink Tank Transceiver
Illustration A:
Illustration B Loop Antenna (TAG) on vehicle fill pipe
OPW-FMS PetroLink System is WIRELESS

connected to an OPW-FMS FSC3000


COMMUNICATIONS
UNIT
STEP 4: Install optional Vehicle
fuel site controller, which controls the FSC3000 Meter (VM) connect wires from
fuel dispensers onsite.
PHOENIX
SOFTWARE VM to vehicle
When the nozzle is removed from the
dispenser, the handle monitor unit STEP 5: Install Software (Phoenix)
(Reader) is activated and signals to the
wireless communications unit.

Next, the PetroLink wireless


communications unit (WCU) seeks to Illustration C
locate the tank transceiver antenna
installed on the vehicle fill pipe.
WIRELESS
COMMUNICATIONS
UNIT

Illustration B: FSC3000

When the nozzle antenna (Reader) PHOENIX


SOFTWARE

locates the tank transceiver antenna


(TAG), it transmits back to the wireless
communications unit (WCU), reporting
the vehicle I.D. and meter number.
To prevent fuel loss, if nozzle is removed
from vehicle fill pipe, the transaction is
Illustration D
automatically terminated.
Illustration C: WIRELESS
COMMUNICATIONS UNIT

If optional Vehicle Meter (VM) is installed,


the wireless communications unit (WCU)
queries the VM to get the odometer
FSC3000

and/or engine hours reading. PHOENIX


SOFTWARE

Illustration D:
The wireless PetroLink application
collects the vehicle I.D. and odometer
and/or engine hours reading and
transmits the data to the FSC3000
which then activates the dispenser.

331
the Fit500 System the Fit500 System Components
THE FIT500 SYSTEM

The FIT500 system combines


leading-edge technology with a FIT500 Powerful Fuel Control System for the
futuristic look and solid stainless petroleummarketerorfleetowner
The latest electronic design with
steel durability, creating an unequalled
rock-solid durability to create a cutting
24-hour fuel management system
edge, 24-hour unattended fueling system
with the quality and reliability that
Petro Vend is renowned for.
With the ability to add customizable
screen images out at the fuel island, USB
the FIT500 is the ultimate fuel Electronic transaction
recording & card updates FSC3000
management system for advertising
special promotions inside the store Fit500 Fuel Control System Features
and for strengthening your brand identity.
Profitability u Remotely download software updates
Benefits Accepts the widest selection to the FSC3000
u Stainless steel enclosure for years of fueling network and u USB memory key for transaction date
of maintenance-free operation major bank cards. storage and card updates
u Dual-head card reader
Customize u Connects with OPW and many other
u High-speed, auto-loading, thermal tank gauges
Customizable color screen
receipt printer with graphics capability
images enhance your marketing u Pump and product totals automatically
u Impressive 10.4" (26.4 cm) programs and activities. or on demand
graphics color display
installation u System and/or dual card (driver and
u Add custom color graphics to
Integrated FSC3000 vehicle) operation
your screen images with a simple

USB memory key. for installations where no u Cardless operation for either driver,
B building is available. USB key for vehicle or both
u Separate alpha, numeric
S
and
U
transaction backup and card file updates.
function key pads are backlit u Drivers and vehicles can be
for easy viewing at night grouped into accounts for easier
Communication
u Supports a multitude of commercial Optional 900 MHz wireless control of group restrictions,
fueling cards, truck fleet cards and communication between island lockouts and reporting
major bank cards and building. Cell modem, Bluetooth and u Daily and monthly credit allocations
u System is field-upgradeable so 802.11 WiFi communication also available. per card or account
B
you can easily add network U
S

interfaces remotely u Easily create your own color graphic u PCI compliance via multi-tracking
images and transfer them to the application PA-DSS (Payment
u Ideal for marine and ethanol Application Data Security Standard)
fueling applications FIT500 via USB memory key
for the FSC3000 Fuel
u USB memory key for transaction u Change receipt paper without opening Site Controller
backup/transfer and updating card files the FIT500 enclosure
u Optional dial-up or cell modem allows u Windows-based ARTWare
communication to remote locations PC software makes programming
u Each FIT500 can also be outfitted simple and provides system backup
with 802.11 WiFi or Bluetooth u System management can be
communication devices to facilitate performed on-site or remotely via
updates and retrieval of dial-up or cell modem, LAN/WAN
transaction data or Bluetooth connection

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
332
networks Counts in gallons or liters from Pedestal Dimensions: 42" H x 17-3/4" W x

THE FIT500 SYSTEM


thousandths to full units 9" D (122 cm H x 36 cm W x 20 cm D)
u The FIT500 System interfaces with
many authorization and commercial Pump sentry provides protection from Operating Temperature Range: -40 F
fueling networks to accept the faulty pulsers to 122 F (-40 C to 50 C)
following cards: u Direct Pump Control communicates via
Power Requirements: 120/240 VAC
CFN Fuelman/Gascard serial link to the dispensers (optional) (auto detectable), 50/60 Hz;
Wright Express Bank cards Supports Wayne, Gilbarco and 250 watts max.
Comdata T-Chek Tokheim protocols
Voyager FleetOne Extremely simple installation
EFS TCH
Pump Control terminal
u Universal Pump Controller for operation
with a pump controller (optional) Specifications
u Dual network option reduces wait time
by accessing 2 networks simultaneously Interfaces with Wayne, Gilbarco and Relay Rating: 1 HP, 120/240 VAC
Tokheim
u Registered bank card feature enables Pulser Compatibility: Contact/12 VDC
secure use credit cards even where Allows pumps to be controlled via the electronic
unattended fuel may be restricted Fuel Island Terminal or retail pump
console Pulser Power Supply: 12 VDC;
u The FIT500 System is field-upgradeable 40 milliamps max./pulser
so you can easily add network interfaces
to meet any needs. Pulser Speed: 6,000 pulses/minute
(mechanical)
Memory Phoenix Software 100,000 pulses/minute (electronic)
u Standard memory has 2,000 proprietary u Phoenix Plus poll transactions, Pulser Rate: 1:1 to 9,999:1 (in one-pulse
cards, and 500 transactions perform card updates, run reports increments)
u Expandable to 64,000 proprietary cards, u Phoenix Premier all of the Phoenix Pulser Type: Single channel
and 2,000 transactions Plus features, plus tank gauge interface
for reconciliation Pulser Duty Cycle: 50%

Pump Control Methods Operating Temperature Range: -40 F to 122 F


Fit500 Fuel island terminal (-40 C to 50 C)
u Pump Control Modules for Commercial
Dispensers with mechanical registers Specifications Cabinet Dimensions of wall-mounted
remote PCM: 11.5" H x 12" W x 6.5" D
Mounted in Fuel Island Terminal for Reader: Magnetic-stripe card with (29 cm H x 30 cm W x 16 cm D)
low-cost, convenient wiring dual-read heads
Power Requirements of Remote PCM:
Mounted in remote cabinet Display: 10.4" (nominal size), Active Matrix 85-240 VAC, 50/60 Hz; 25 watts max.
Pump Handle Monitor VGA Color Display
Operating Temperature Range of
Manual bypass for each dispenser Receipt Printer: The high-resolution, Remote PCM: -40 F to 122 F
4 adjustable fueling timers thermal receipt printer has an integral (-40 C to 50 C)
cutter and large paper roll
Maximum fueling time
Maximum time to activate Keypads: The keypads are durable and
pump handle weather-resistant
Maximum time until first pulse Cabinet Dimensions: 20" H x 17-3/4" W x
11-3/8" D (38 cm H x 46 cm W x 28 cm D)
Maximum time between pulses

FSC3000 Fuel Site Controller Specifications


Dimensions: 2" H x 10" W x 11" D (5 cm H x 25 cm W x 28 cm D)
Power Requirements: 85-240 VAC, 50/60 Hz; 25 watts max.
Operating Temperature Range (indoors): 32 F to 122 F (0 C to 50 C)
Serial Communication Ports: Petro-Net (RS-485), Printer (RS-232), Terminal
(RS-232), Modem (RS-232), Pass-through (RS-232), 2 Auxiliary Ports (RS-232),
Tank Gauge, Ethernet, USB
Maximum Petro-Net Distance: 5,000 feet (1,524 m)

333
C/OPt Fuel Control C/OPt Fuel Control System Components
C/OPT FUEL CONTROL SYSTEM

System
Up to 8 C/OPT Fuel Island Terminals (FIT)
Nowwiththeflexibilityofhaving
used by drivers at the island to activate the
the FSC 3000 within the Fuel Island
fuel dispensers
Terminal, as a stand-alone system,
making this the best solution for USB

your 24-hour fueling sites accepting Electronic transaction


recording & card updates

commercialfleetormajorbankcards.
With a wide variety of options
available, Petro Vends C/OPT
C/OPT FSC3000
Fuel Control System is one of the
most comprehensive solutions for
your fleet-fueling or petroleum C/OPt Fuel Control System Features
marketing application. u Selectable automatic lockout after three
Profitability
Accepts the widest selection incorrect PIN entries for added security
Benefits
of fueling network and u Dual card accountability allows
u Each FSC3000 can control up to major bank cards. tracking and reporting on drivers
8 FITs with a maximum of 32 hoses using multiple vehicles
per site easy-to-use u Communication ports allow for journal
Customizable prompts for driver printer, PC, serial pass-through port,
u Graphics display guides users clarity. ARTWare PC software modem and Petro-Net connection
through the fueling process with makes configuration a snap.
pictures and text u Wireless Petro-Net communication
reduces installation costs
u Accepts dual readers including installation
Integrated FSC3000 for u Odometer reasonability checking ensures
magnetic, optical, proximity and accurate odometer entries
installations where no building is
ChipKey for maximum Bflexibility u Nine-character name field makes card
S available. USB key for transaction backup
and reliability U
and card file updates. record reporting more complete
u Optional full alpha keypad allows u Cardless/keyless access allows drivers to
entry of vehicle tags and other Communication fuel using a quick keypad entry
alpha information Optional 900 MHz wireless u Office journal printer for transaction log
communication between island and report
u Smart weather shield automatically and building. Cell modem, Bluetooth and
closes to protect card readers and 802.11 WiFi communication also available.
receipt chute S
B networks
u PCI complianceU via multi-tracking
u Fiber-optically lit keypads and LED application PA-DSS (Payment u The C/OPT System interfaces with
Application Data Security Standard) for many authorization and commercial
backlit display for easy fueling at night fueling networks to accept the
the FSC3000 Fuel Site Controller
u Optional thermal receipt printer following cards:
u USB memory key for transaction data
u USB memory key for transaction storage and card updates CFN Fuelman/Gascard
backup/transfer and updating card files T-Chek Bank cards
u Individual drivers and vehicles can be Comdata Pacific Pride
u Optional dial-up or cell modem allows grouped into accounts for easier control Voyager FleetOne
communication to remote locations of group restrictions and lockouts EFS TCH
u Extensive reporting capabilities with Wright Express
u Each C/OPT can also be outfitted
Phoenix Software
with 802.11 WiFi or Bluetooth u Dual network option reduces wait
communication devices to facilitate u Daily and monthly credit allocations per time by accessing two networks
card/key/account lets you set fueling simultaneously
updates and retrieval of
restrictions
transaction data

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
334
u The registered bank card feature permits Memory Pump Control terminal

C/OPT FUEL CONTROL SYSTEM


24-hour fueling in areas where unattended u Standard memory has 2,000 proprietary Specifications
fueling is generally restricted cards and 500 transactions Relay Rating: 1 HP, 120/240 VAC
u The C/OPT System is field-upgradeable u Expandable to 64,000 proprietary cards,
so you can easily add network interfaces to Pulser Compatibility: Contact/12 VDC
and 2,000 transactions electronic
meet any needs.
Pulser Power Supply: 12 VDC;
Phoenix Software 40 milliamps max./pulser
Pump Control Methods
u Phoenix Plus poll transactions, Pulser Speed: 6,000 pulses/minute
u Pump Control Modules for commercial perform card updates, run reports
dispensers with mechanical registers (mechanical) 100,000 pulses/minute
u Phoenix Premier all of the Phoenix (electronic)
Mounted in Fuel Island Terminal for Plus features, plus tank gauge interface
low-cost, convenient wiring Pulser Rate: 1:1 to 9,999:1 (in one-pulse
for reconciliation increments)
Mounted in remote cabinet
Pulser Type: Single channel
Pump handle monitor C/OPt Fuel island terminal Pulser Duty Cycle: 50%
Manual bypass for each dispenser Specifications Operating Temperature Range: -40 F
Four adjustable fueling timers Readers: Magnetic-stripe card, optical to 122 F (-40 C to 50 C)
Maximum fueling time card, ChipKey, proximity reader Cabinet Dimensions of Wall-Mounted
Maximum time to activate pump Displays: (both have LED backlights) Remote PCM: 11.5" H x 12" W x 6.5" D
handle Standard graphics (3" x 4" 320 x 240 (29 cm H x 30 cm W x 16 cm D)
Maximum time until first pulse pixels), Optional LCD (2 lines x 20 characters) Power Requirements for Remote PCM:
Maximum time between pulses Receipt Printer (optional): The 85-240 VAC, 50/60 Hz; 25 watts max.
high-resolution, thermal receipt printer has Operating Temperature Range of Remote
Counts in gallons or liters from an integral cutter and large paper roll
thousandths to full units PCM: -40 F to 122 F (-40 C to 50 C)
Keypads (standard and optional alpha):
Pump sentry provides protection from keypads are constructed of a UV-stable
faulty pulsers weather-resistant material over stainless
u Direct Pump Control communicates via steel contacts
serial link to the dispensers (optional) Cabinet Dimensions: 15" H x 18.5" W x 11" D
Supports Wayne, Gilbarco and (38 cm H x 46 cm W x 28 cm D)
Tokheim protocols Pedestal Dimensions: 48" H x 14" W x 8" D
Extremely simple installation (122 cm H x 36 cm W x 20 cm D)
u Universal Pump Controller for Operating Temperature Range: - 40 F to
operation with a pump controller 122 F (- 40 C to 50 C)
(optional) The rugged, tamper-resistant ChipKey is a
Power Requirements: 120/240 VAC popularalternativetocards.Itfitseasilyontoa
Interfaces with Wayne, Gilbarco (auto-detectable), 50/60 Hz; 250 watts max. customers key ring, so its convenient and hard
and Tokheim to lose. Every ChipKey contains a microchip that
can be programmed and reprogrammed as many
Allows pumps to be controlled via times as you like.
the Fuel Island Terminal or retail
pump console

FSC3000 Fuel Site Controller Specifications


Dimensions: 2" H x 10" W x 11" D (5 cm H x 25 cm W x 28 cm D)
Power Requirements: 85-240 VAC, 50/60 Hz; 25 watts max.
Operating Temperature Range (indoors): 32 F to 122 F (0 C to 50 C)
Serial Communication Ports: Petro-Net (RS-485), Printer (RS-232), Terminal
(RS-232), Modem (RS-232), Pass-through (RS-232), 2 Auxiliary Ports (RS-232), With the proximity reader option installed in your
C/OPT Fuel Island Terminal, fueling access is
Tank Gauge, Ethernet, USB
either granted or denied a cardholder when their
Maximum Petro-Net Distance: 5,000 feet (1,524 m) proximity card is waved within a few inches of
the reader.

335
k800 hybrid k800 hybrid Fuel Control System Components
K800 HYBRID FUEL CONTROL SYSTEM

Fuel Control System


Easy to install, use and maintain, the K800 Hybrid
Nowwiththeflexibilityofhaving
Fuel Control System is ideal for small private fleets
the fuel site controller within the
Fuel Island Terminal as a standalone needing a low cost fuel management solution.
system for sites that require
USB
outdoor installations, or as a
Electronic transaction
separate unit indoors. recording & card updates

Whether operating a small fleet with a


single fuel site or a large fleet with multiple
K800 Hybrid
sites, the PetroVend K800 Hybrid Fuel FSC3000
Control System can help you improve the
management of your unattended fueling k800 hybrid Fuel Control System Features
operations by controlling one of your Savings u Compatible with optional PetroLink
biggest assets and expenses your fuel. Ideal for small private fleets RFID system, allowing vehicle I.D.,
mileage and other information to be
Benefits needing a low-cost fuel management
automatically captured through an
system.
installed fuel nozzle antenna at the
u Ideal for small private fleets needing a
vehicles fueling pipe
low-cost fuel management solution. easy-to-use
Customizable prompts for driver u Pump and product totals automatically
u Each Island Terminal controls up to or on demand
clarity. ARTWare PC software makes con-
4 mechanical dispensers
figuration a snap. u System can be set to track the
u Each FSC3000 can control up mechanical pump totalizers
to 8 FITs with a maximum of 32 hoses installation
per site S
B
Integrated FSC3000 for u Daily and monthly allocation amounts
U

installations where no building is available. u 16 quantity restriction levels


u Backlit LCD provides enhanced visibility
USB key for transaction backup and card
in bright sunlight and at night u 16 product restriction combinations
file updates.
u Programmable prompts to guide drivers u Odometer or hourmeter recording
through the fueling process Communication
u User can be prompted to enter
u Durable metal keypad, 16-gauge Optional 900 MHz wireless
miscellaneous data of up to 10 digits
steel enclosure and thermostatically communication between island and building. (job, vehicle, driver ID, etc.)
controlled heater for reliable operation Cell modem, Bluetooth and 802.11 WiFi
communication also
B
u Single or dual card/key/cardless entry
U available.
S
in the harshest environments operation (driver/vehicle number)
u Downloadable software for easy u PCI compliance via multi-tracking
u Cards can be assigned to accounts
system upgrades application PA-DSS (Payment
or departments
Application Data Security Standard) for
u USB memory key for transaction u Card/key/account lockout
the FSC3000 Fuel Site Controller
backup/transfer and updating card files
u Windows-based ARTWare u Programmable K800 Fuel Island
u Optional dial-up or cell modem allows Terminal displays messages and
PC software makes programming
communication to remote locations simple and provides system backup user prompts
u Each K800 Hybrid can also be u System management easily performed u A price may be assigned to each
outfitted with 802.11 WiFi or Bluetooth on-site or remotely via dial-up, cell product to be recorded for
communication devices to facilitate phone modem, LAN/WAN, or Bluetooth each transaction
updates and retrieval of transaction data

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
336
u Standard system utilizes dispensers with mechanical registers Phoenix Software

K800 HYBRID FUEL CONTROL SYSTEM


magnetic cards
Mounted in Fuel Island Terminal for Phoenix Plus poll transactions,
u ChipKey mileage and reasonability

low-cost, convenient wiring perform card updates, run reports
assures accurate mileage entry Phoenix Premier all of the Phoenix
Mounted in remote cabinet
u Optional proximity card reader Plus features, plus tank gauge interface
Pump handle monitor for reconciliation
u Programmable system
open/close times Manual bypass for each dispenser
4 adjustable fueling timers
k800 hybrid Fuel island
u Password protection for
ultimate security terminal Specifications
Maximum fueling time
u Self-test and diagnostic utilities Readers (any one of the following):
Maximum time to activate pump Magnetic-stripe card
for start-up and troubleshooting
handle
ChipKey
u Office journal printer for transaction
logging Maximum time until first pulse HID proximity card/key (optional)
Maximum time between pulses Display: 2-line x 16-character backlit LCD
u USB key for transaction information
backup and card updates Enclosure Dimensions: 12" H x 13" W x 10" D
Counts in gallons or liters from
thousandths to full units (30.5 cm H x 33 cm W x 25.5 cm D)
u Optional Bluetooth or cell modem
communication for remote sites Power Requirements: 120/230 VAC;
Pump sentry provides protection from
50-60 Hz; 100 watts max.
u Optional 900 MHz wireless faulty pulsers
communication between island Operating Temperature: -40 F to 122 F
u Direct Pump Control communicates via
and building (-40 C to 50 C)
serial link to the dispensers (optional)
u The K800 Hybrid System
Supports Wayne, Gilbarco and
interfaces with many commercial Pump Control terminal
Tokheim protocols
fueling networks Specifications
Extremely simple installation
Memory Relay Rating: 1 HP, 120/240 VAC
u Universal Pump Controller for
u Standard memory has 2,000 Pulser Compatibility: Contact/12 VDC
operation with a pump controller
proprietary cards, and 500 electronic
(optional)
transactions
Pulser Power Supply: 12 VDC;
u Expandable to 64,000 proprietary Interfaces with Wayne, Gilbarco and
40 milliamps max./pulser
cards, and 2,000 transactions Tokheim
Pulser Speed: 6,000 pulses/minute
Allows pumps to be controlled via
Pump Control Methods (mechanical)
the Fuel Island Terminal or retail
u Pump Control Modules for commercial 100,000 pulses/minute (electronic)
pump console
Pulser Rate: 1:1 to 9,999:1 (in 1-pulse
increments)
FSC3000 Fuel Site Controller Specifications Pulser Type: Single channel
Dimensions: 2" H x 10" W x 11" D (5 cm H x 25 cm W x 28 cm D) Pulser Duty Cycle: 50%
Power Requirements: 85-240 VAC, 50/60 Hz; 25 watts max. Operating Temperature Range: -40 F to
Operating Temperature Range (indoors): 32 F to 122 F (0 C to 50 C) 122 F (-40 C to 50 C)
Serial Communication Ports: Petro-Net (RS-485), Printer (RS-232), Terminal
(RS-232), Modem (RS-232), Pass-through (RS-232), 2 Auxiliary Ports (RS-232),
Tank Gauge, Ethernet, USB
Maximum Petro-Net Distance: 5,000 feet (1,524 m)

337
k800 Fuel Control k800 System Components
K800 FUEL CONTROL SYSTEM

System Each system consists of the following K800 FIT


2 components:
Be in control of your unattended fueling
operation with Petrovends K800 Fuel 1 Fuel Site Controller (FSC) the hub
of the system - stores transactions and
Control System. The K800 provides
connects peripherals
you with the tools you need to manage
your fuel expenses. Fuel access is Up to 4 K800 Fuel Island Terminals
restricted to authorized users, and set to (FIT) used by drivers at the island to
activate the fuel dispensers
the fuel type and quantity you specify.
Every transaction is tracked, giving you K800 FSC
the security and accountability your
unattended fueling operation needs. k800 Fit Features k800 FSC Features
u Backlit LCD for visibility in bright u Controls up to 4 Fuel Island Terminals
sunlight or at night and 16 hoses simultaneously to meet
your needs today and tomorrow
u Programmable prompts to guide drivers
through the fueling process u Up to 10,000 cards and 1,800
transactions can be stored in memory
u Durable alloy keypad, 16-gauge
steel enclosure and thermostatically- u Menu-driven programming with
onscreen help for ease of use
controlled heater for reliable operation
in the harshest environments u Serial communication ports for printer,
PC and modem
u High-impact plastic door overlay and
powder-coated enclosure and matching u Desktop controller can also be
conveniently wall-mounted
pedestal maintain their appearance for
years to come u Easily interfaces to existing
personal computers
u Built-in diagnostics for simplified
troubleshooting u Dual card accountability allows tracking
and reporting on drivers using
u Built-in pulser power supply, pump multiple vehicles
control and pre-punched conduit access
u Cardless/keyless access allows drivers
for easy installation
to fuel using a quick keypad entry
u Can be activated either by card (optical
u ChipKey mileage reasonability option
or magnetic-stripe), ChipKey or code
ensures accuracy of odometer entries
activated
u Lock out any key or card
u Manual bypass switch for each hose
u Provides basic inventory tracking
u 4 adjustable fueling timers per
u Wireless Petro-Net communication
hose position
reduces installation costs
u Provides 4 levels of authorized
time access

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
338
additional Features

K800 FUEL CONTROL SYSTEM


u Restricts product and quantity for any u Standard report package groups cards
key, card or account together by account and provides
u Restricts number of transactions per itemized reports including MPG, CPM
day for any key or card and price extensions

u Adjustable pump time-outs u Personal Identification Number (PIN)


entry with auto-lockout
u Pump handle monitor and pulser sentry
u Inventory, pump and product
u Diagnostic test programs for system
total reports The rugged, tamper-resistant ChipKey is a
start-up and troubleshooting popularalternativetocards.Itfitseasilyontoa
customers key ring, so its convenient and hard
u 4 memory levels available (up to 2 to lose. Every ChipKey contains a microchip that
can be programmed and reprogrammed as many
megabytes total) times as you like.

k800 Fuel island terminal Specifications


Readers: Magnetic-stripe card, optical card, ChipKey
Display: Backlit LCD (2 lines x 16 characters)
Keypad: Durable alloy keypad
Cabinet Dimensions: 12" H x 13" W x 10" D (30.5 cm H x 33 cm W x 25.5 cm D)
Pedestal Dimensions: 48" H x 14" W x 8" D (122 cm H x 36 cm W x 20 cm D)
Operating Temperature Range: - 40 F to 122 F (- 40 C to 50 C) Phoenix Plus, and Phoenix Premier are
powerful fuel management software packages
Power Requirements: 120/230 VAC, 50/60 Hz; 100 watts max. for your Windows-compatible PC (see page 340
for detailed information).

k800 Fuel Site Controller Specifications


Cabinet Dimensions: 2" H x 9" W x 11" D (5 cm H x 23 cm W 28 cm D)
Operating Temperature Range: 32 F to 122 F (0 C to 50 C)
Power Requirements: 120/230 VAC, 50-60 Hz; 50 watts max.
Maximum Petro-Net Distance: 5,000 feet (1,524 m)

339
PhOenix Software Phoenix Components
PHOENIX
FUEL MANAGEMENT SOFTWARE

For advanced A K800, K800 Hybrid, C/OPT,


Management FIT500 or PetroLink Fuel
Control System
Phoenix Plus, and Phoenix Premier
are powerful fuel management software A Windows PC with 500 MHz or
packages for your C/OPT, K800, higher processor speed running
K800 Hybrid, FIT500 and PetroLink Windows XP or Windows Vista,
Fuel Management Systems and your 128 MB RAM,CD-ROM drive,
Windows-compatible PC. The intuitive 250 MB hard disk space and
user interface lets you easily navigate a 800 x 600 display
between site, account, card and
transaction screens. Phoenix Plus Features
Phoenix Plus is a powerful data u Centralized control over your fueling u Phoenix allows you to choose from over
management and communications operations, featuring back-up and 60 different reports
software package that gives you restore, terminal emulation and u Enhanced Odometer Checking reveals
total, centralized control over your on-demand or automatic obvious, incorrect mileage entries
fueling operations, featuring back-up transaction polling such as single, sequential or
and restore, terminal emulation and u Reporting feature lets you report on repeated numbers
on-demand or automatic transaction multiple sites at one time and schedule u Compatible with Windows XP
polling, plus reporting capability. the printing of reports and export data. and Vista
Phoenix Premier offers complete site Reporting capability also includes any
reconciliation by incorporating additional network transactions that are found in
site data from your OPW tank gauge Fuel Site Controller software versions
or other brand of tank gauge. like VisaNet and Multi-Trucking.

Most data can be exported to a


third-party database, spreadsheet
and fleet maintenance programs
for further processing.

NOTE: See OPW Fuel Management Systems


Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
340
Phoenix Premier Features

PHOENIX
FUEL MANAGEMENT SOFTWARE
u Polls Petro Vend FSC3000/System2 u Provides communication through
for site, account, card, and transaction modem, Ethernet, or direct connection
data, and OPW tank gauges (or other u Eliminates the need for 2 separate lines
brands of automatic tank gauges) for and modems when polling via
real-time fuel inventory information for phone lines
reconciling a sites fueling activities
u Automatic and on-demand transaction
u Ideal for owners of multiple fuel polling enhances ease of reporting
sites who want to integrate the reconciliation information
management of their facilities into
u Centralized card database for
one centralized computer
multiple sites (FSC3000, System2
u Based on Phoenix Plus software version only)
package, and includes full-featured
u Facilitates daily inventory management
back-up and restore, automatic and
on-demand transaction polling, card u Reduces training costs Windows-
management, and over 60 reports based program is easy to learn,
easy to use
u Runs on a Windows PC compatible
with Windows XP or Windows Vista u Stores records in your back-office
PC environment for easy retrieval
Phoenix PC requirements and management
u A Windows PC with 500 MHz or higher
processor speed
u 128 MB RAM
u Runs on a Windows PC compatible
with Windows XP or Windows Vista
u CD-ROM drive
u 250 MB hard disk space
u 800 x 600 display
u Available communications port

341
aFC Fuel Control aFC System Components
AFC FUEL CONTROL SYSTEM

System

With the AFC Fuel Control System One Stand-Alone AFC Terminal
managing your fleet, youll never have can control from 2 to 8 hoses.
to wonder when vehicle maintenance is
due, who gets which fuel type, where
your fuel goes, or how to keep track of
your vehicles.

This turn-key fuel control system for small


to mid-size fleets is easy to use and set
up. The AFCs durable, weather-resistant
aFC Features
stainless-steel construction ensures years
of uninterrupted service. And because u Durable stainless-steel enclosure u Weather shields guard card/DuraKey
its modular, maintenance can be and pedestal reader ensuring uninterrupted operation
accomplished quickly, reducing down u System configuration via remote PC in the most inclement weather
time and operating costs. u Standard display heater ensures normal
u Track declining tank inventory, with
low-level alert and programmable pump operation in cold temperatures
deactivation levels u Selectable maximum fuel by
u Access the AFC with the traditional fueling position
magnetic card, system keypad or the u Selectable automatic shift change
durable DuraKey u Deactivation on pulser failure
u Capacity: u Department discounts
255 departments
u Fuel management features include:
16 fuel types
Fuel type and assignment report
Up to 8 fueling positions
Fuel type pricing
999 stored transactions
Security against product theft
2-, 4-, 6- or 8-hose capacity
Totals by fuel type and fuel position
10,000 card/DuraKey capacity
Totals by shift
u Fleet management features include: Grand totals
Odometer reasonability Running totals
Vehicle classification
u Automatically keeps track of all
Maintenance alerts and lockout
transactions by vehicle, driver and
Fueling restriction by fuel type/quantity
department, eliminating manual
Taxable and nontaxable fuel totals
record keeping
Programmable user prompts
u Accumulates information on card/
u Lithium battery protects stored
DuraKey numbers, date and
transaction data during power losses
time of access, hose number, and
amount fueled

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
342
additional Features

AFC FUEL CONTROL SYSTEM


u Provides comprehensive reports for u Field wiring terminals are clearly
critical fuel management decisions marked and easily accessible in the
u Administrator PC software is used to spacious enclosure
program vehicles, drivers, personal u Modular design makes servicing
identification numbers, limits, etc. the AFC easy
u ASCII utility exports data to third-party u Fewer cable connections minimize
software packages maintenance and decrease
u Historical totalizer readings provide service time
data for inventory reconciliation u Manual override switches allow you to
u Pre-punched conduit termination panel bypass the card system if the unit is
simplifies installation not operational

aFC Specifications
Readers: Magnetic-stripe card, DuraKey
Display: 4-line, 20-character backlit display
Cabinet Dimensions: 10" H x 12" W x 20" D (25.4 cm x 30.4 cm x 50.8 cm)
Operating Temperature Range: -40 F to 158 F (-40 C to 70 C)
Input Power: 120/240 VAC, 50/60 Hz, 100 watts
Output Relay Rating:
Motor Duty: 1 HP @ 120 VAC; 3 HP @ 240 VAC
Pulser Supply: 12 VDC, 2.5 W max.

343
keegarD keegard System Components
KEEGARD FUEL CONTROL SYSTEM

Fuel Control System


One stand-alone, Keegard Master Unit
can hold up to 30 keys and counters
A Keegard system is a performance
engineered, solid-state, automated fuel Unlimited Additional Optional Slave
control system, providing maximum Units add up to 60 additional counters
per slave unit
security and accountability of your fuel.
It is the highest quality and most reliable
electronic design of any key system
existing today. The Keegard activates
a fuel dispenser with a high-security,
registered, individual key. The solid-state
construction and plug-in modular design Features Options
makes maintenance effortless. The
Keegard master unit can hold up to u Adaptable to most existing standard u Automatic Inventory Status Counter,
30 keys and counters. If there is a need or commercial fuel dispensers using a resettable totalizer, allows the owner
for a greater capacity, the modular design pulser kits available from OPW Fuel to control fuel inventory by daily or
allows you to expand a system to suit Management Systems weekly usage
your needs. u Instantly lock out or reinstate any key u Buzzer system alerts keyholder that he
that may be lost or stolen has left his key in the unit after he has
easy Operation
u 2 key lock out permits only 1 key finished fueling
Insert a key into its proper lock and turn
to activate the fuel dispenser and control to operate at a time if a second key is u Optional heater prevents condensation
system. As the fuel is dispensed, the inserted and turned, the pump will and ensures operation in cold climates
counters record every tenth of a gallon shut down u Visible Counters allow users to verify
or liter taken. To deactivate the pump, u Keegard will delay the starting of the

their gallonage
simply hang up the fuel nozzle or turn the pump after the key is turned on to u Weather Shield protects the unit
key back to the off position and remove. eliminate milking of product during inclement weather
extremely accurate u The Missing Pulse Detector feature
The Keegard tracks usage with is designed to shut the pump off if no
non-resettable counters. Each precision- pulse is detected
made counter is tamper-proof and
accurately records up to 100 gallons or Specifications
liters per minute, to the nearest tenth
Cabinet Dimensions: 15" H x 12" W x 7" D (38 cm H x 30 cm W x 17 cm D)
(1,000 pulses per minute). The counters
record up to 99,999.9 gallons or liters, Power Requirements: 115 or 220 volts; single phase
and then automatically reset. Weight: 30-key system weighs approximately 40 lbs. (18 kgs)
Box: Exceeds specifications for NEMA type (4) box
Counters: Non-reset type 99,999.9; capacity to record 100 GPM or LPM at 1,000 pulses/min.

listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
344
Model 400-B Model 500 PulSerS

PULSERS
Features Features Petro Vend Fuel Control Systems offer a
u Direct replacement u Main shaft and complete family of pulsers to meet your
for the VR-1871 shaft extensions are fuel management needs.
u No conduit machined from solid
required between aluminum
Model 788
barrier and pulser u Intrinsically safe
head
Features
u No conduit required
u Almost unlimited speed between barrier and pulser head u Minimizes
u Will pulse any voltage 5 to 170 volts u Will pulse any voltage 5 to 170 volts wear and tear
AC or DC AC or DC of new style
registers
u Compatible with most self-service u Compatible with most self-service readout
read out equipment, card and equipment, card and key systems u Easy to align
key systems u Jumpers used to set pulser for type of u Passive contact closure type pulsers
u Available in 12 VDC, 24 VDC, 120 VAC pump computer being used u No gears or mechanical parts
and 220 VAC u Available in 12 VDC, 120 VAC and u Economical alternative to the VR-1871
220 VAC u Optional whole gallon pulsing
u Compatible with most card and
key systems

Model 800 Model 50 Model 7000


Features Features interface
u No conduit u Will pulse any Barrier
required between voltage 5 to 170 Features
barrier and volts AC or DC u Available in 12
optical head u Compatible with VDC, 24 VDC
u Will pulse any most self-service and 120 VAC
voltage 5 to 170 volts AC or DC readout equipment, u Will pulse any voltage 5 to 170 volts
u Compatible with most self-service readout card and key systems AC or DC
equipment, card and key systems u Available in 120 VAC u Compatible with most self-service
u Available in 12 VDC, 120 VAC and readout equipment, card and key systems
220 VAC u Intrinsically safe
u Interfaces with the VR 7874 series
pulser/totalizer

MODEL 400-B* 500 800-F 50 788 7000 BARRIER GB PULSER INTERFACE

PART NUMBER 4000400 4000500 4000800-F 400050 4000788 70001-B 4500300

PULSE RATIO /
$.01 1/10 /
$.01 1/10, 1/100 1/10 1/10 1, 1/10 /
$.01 1/10 1/100

COMPUTING DEVICE
n n n
101 n n n
n n
2001/2002 n n n

2002E * n n
* n n
n
VR10/4 n
n
VR10 n

NON-COMPUTER * n n

FILL-RITE 800/900 n

TOKHEIM/GASBOY 793/50 n

VEEDER-ROOT 7886/7887
n
NEW STYLE
GILBARCO HIGHLINE
n
111B/MPD
* Model 400-B will not work on computers with plastic drive gear on penny or tenth wheel.
New or remanufactured computers may have this plastic gear. Computers with this gear require the Model 500 Pulser.
345
THE WORLD IS MADE UP OF PRISTINE ENVIRONMENTS

346
346

Anda mungkin juga menyukai