manaGement sYstems
SiteSentinel iSite
SiteSentinel iTouch
From the most innovative tank gauging systems in the world to the
you know exactly how much fuel you have and where it is going.
Phoenix Software
1-800-422-2525 | www.opwglobal.com
309
OPW Fuel
OPW FUEL MANAGEMENT SYSTEMS
Management
Systems
OPW Fuel Management Systems
delivers product excellence and a broad
line of fuel control and tank gauge
solutions to retail and commercial
fueling operations worldwide. OPW
Fuel Management Systems is part of
OPW Fueling Components, the global
leader in fueling solutions, offering
the most comprehensive line of fueling
equipment and global support in the
world for over 40 years.
NOTE: See OPW Fuel Management Systems Website at www.opwglobal.com for detailed
310 product literature, manuals and sales representative contact information for your area.
Electronic Fuel Management Systems
uF
uel Controls
PetroLink Fuel Control System ......... 330 - 331
FIT500......................................................................... 332 - 333
C/OPT.......................................................................... 334 - 335
K800 Hybrid ......................................................... 336 - 337
K800 ............................................................................. 338 - 339
Phoenix..................................................................... 340 - 341
AFC ................................................................................ 342 - 343
Keegard .................................................................................... 344
Pulsers ........................................................................................... 345
3 BeSt-in-ClaSS
line leak
DeteCtiOn
2 BeSt-in-ClaSS
BeSt-in-ClaSS SiteSentinel iSite VSMart 4 BeSt-in-ClaSS
1
Or itOuCh COnSOle MODule DenSity
MeaSureMent
7 BeSt-in-ClaSS
924B MagnetOStriCtiVe
PrOBe
6 BeSt-in-ClaSS
Mag SuMP
SenSOrS
5 BeSt-in-ClaSS 8 BeSt-in-ClaSS
intelliSenSe aSt FlexiBle
SMart SenSOrS PrOBe
8
10 FSC3000 Fuel Site COntrOller
inSiDe the Fuel iSlanD terMinal
1
15 Color LCD 10
9
Touchscreen
Display
One-Wire
connection
or optional Up to 4 LLD sensors can
wireless be daisy-chained together
communication per IS Barrier
3
6 6
Up to 16 IntelliSense
Smart Sensors can be
daisy-chained together
per IS Barrier
Up to 4 probes
5 7
can be daisy-
chained together
per IS Barrier
11 PhOenix SOFtWare
312
OPW Tank Gauges
Console
Part of the
315
the VSmart Module the VSmart Module Components
THE VSMART MODULE
B
S
U
listings and
Certifications
316
the VSmart Module Specifications
VSmart Module
VSmart Module Capabilities
2 4-channel IS Modules per VSmart Module
Maximum of 8 IS Channels per VSmart Module
Maximum of 8 VSmart Modules per console
Maximum of 8 AST Flex Probes per VSmart Module
Maximum of 32 model 924B Probes per VSmart Module
Maximum of 128 Active or Passive Sensors per VSmart Module
(Intellisense Sensors)
1 2 3 4
IS
Up to 4 Multi-Drop Probes
OR
1 AST Flex Probe
Any combination of up to
16 IntelliSense Smart Sensors
317
SiteSentinel itouch itouch Console Components
SITESENTINEL ITOUCH CONSOLE
System Features
applications
Compliance u Graphic touchscreen display uses
u Provides real-time, accurate inventory international user-friendly icons
The certified leak detection
information
meets or exceeds U.S. EPA regulatory u Monitors up to 16 probes and/or
u Displays gross- or net-corrected tank requirements, protecting the environment sensors that can be connected in
volume, product level, water level, in and around storage tanks. any combination
and temperature for individual tanks
u Touchscreen provides one-touch
u Available output module provides easy-to-use access to real-time inventory data,
multi-purpose relays, which can The graphic display gives delivery status, alarm conditions
be used for outputs such as one-touch access to real-time inventory and leak detection information
overfill or sensor alarms data, delivery status, alarm conditions
u SiteConnect software, a Windows-
and leak-detection information.
u Third-Party certified automatic or U
S
B
based configuration utility, makes site
on-demand leak detection meets configuration easy
automated
and/or exceeds U.S. Environmental u Compatible with SmartTalk software
Programmable Automatic Leak
Protection Agency regulatory for enhanced business management
Detection (ALD) can be set to perform
requirements and compliance reporting
routine required leak tests. The system
can automatically e-mail alarms u Automatic Leak Detection (ALD)
and events. can be programmed to perform
daily, weekly, monthly and
Connectivity annually required leak tests. Once
Monitors up to 16 probes or programmed, the iTouch system will
sensors that can be connected in any automatically look for the appropriate
combination. Reports can be printed on quiet time over the course of the day
to conduct a static leak test without
the external printer or from SiteConnect
operator intervention.
on the PC printer.
u System provides over 400
U
S
B
programmable correction factors
guaranteeing the most accurate
tank chart
listings and
Certifications
318
itouch additional System Features Power requirements
319
924B Magnetostrictive
924B MAGNETOSTRICTIVE PROBE
Probe
Compliance
Supports programmable
ALD (Automatic Leak Detection) to
perform daily, weekly, monthly and
annually required leak tests as well as
Segmented Leak Detection (SLD) for
24-hour continuous monthly leak tests
B
U
S
(for SiteSentinel iSite only).
listings and
Certifications
1180
320
Compliance
MANHOLE HEIGHT
TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH TANK DIAMETER + MANHOLE HEIGHT* + 3 in. (8 cm) Minimum = PROBE LENGTH
* (Top of Tank to Top of Manhole Cover) * (Top of Tank to Top of Manhole Cover)
321
SiteSentinel iSite aSt Flex Probe Components
SITESENTINEL ISITE AST FLEX PROBE
B
S
U
B
S
U
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
322
Probe length availability Specifications
u 193" (16') to 216" (18') 490 cm (4.84 m) to 548 cm (5.45 m) Repeatability: +/- 0.001% of full scale,
+/- 0.00025" (.00635 mm), whichever
u 217" (18') to 240" (20') 551 cm (5.45 m) to 609 cm (6.06 m)
is greater
u 241" (20') to 264" (22') 612 cm (6.06 m) to 670 cm (6.66 m)
Temperature Accuracy: Absolute +/- 2 F
u 265" (22') to 288" (24') 673cm (6.66 m) to 731 cm (7.27 m) (1.11 C)
u 289" (24') to 312" (26') 734 cm (7.27 m) to 792 cm (7.87 m) Temperature Measurement Resolution:
u 313" (26') to 336" (28') 795 cm (7.87 m) to 853 cm (8.48 m) +/- 0.01 F (.02 C)
u 337" (28') to 360" (30') 855 cm (8.48 m) to 914 cm (9.09 m) Temperature Sensing Range: -40 F to
+150 F (-40 C to +65 C)
u 361" (30') to 384" (32') 916 cm (9.09 m) to 975 cm (9.69 m)
Operating Temperature Range: -40 F to
u 385" (32') to 396" (33') 977 cm (9.69 m) to 1005 cm (10 m)
+160 F (-40 C to +71 C)
u 397" (33') to 408" (34') 1008 cm (10 m) to 1036 cm (10.3 m) Distance to VSmart Module: Up to 1,000'
u 409" (34') to 420" (35) 1038 cm (10.3 m) to 1066 cm (10.6 m) using twisted-pair wire
u 421" (35') to 432" (36') 1069 cm (10.6 m) to 1097 cm (10.9 m) Environment: NEMA 4
u 433" (36') to 444" (37') 1099 cm (10.9 m) to 1127 cm (11.21 m) Listings: UL, Intrinsically Safe
u 445" (37') to 456" (38') 1130 cm (11.21 m) to 1158 cm (11.51 m) Maximum Tank Capacity: 99,999,999
gallons (approx. 378,541,176 liters)
u 457" (38') to 468" (39') 1160 cm (11.51 m) to 1188 cm (11.81 m)
Water Float Liftoff: 2-1/2" (6.35 cm)
u 469" (39') to 480" (40') 1191 cm (11.81 m) to 1219 cm (12.12m)
at 70 F (21 C)
u 481" (40') to 492" (41') 1221 cm (12.12 m) to 1249 cm (12.42 m)
u 493" (41') to 504" (42') 1252 cm (12.42 m) to 1280 cm (12.72 m)
u 505" (42') to 516" (43') 1282 cm (12.72 m) to 1310 cm (13.03 m)
u 517" (43') to 528" (44') 1313 cm (13.03 m) to 1341 cm (13.33 m)
323
intelliSense intelliSense System Components
INTELLISENSE TECHNOLOGY
technology
Delivers the ability to monitor all areas
of the fuel site tank interstice, piping
sumps, STP containment sumps,
dispenser sumps/pans and monitoring
Part of the
wells. IntelliSense technology allows
for interfacing all sensors through a
single 3-core cable connection. This
propriety technology is designed so
family of products
that the SiteSentinel iSite controller,
regardless of the type or place of
installation, will know immediately
intelliSense Features Sensors
what type of sensor is connected and innovative Discriminating Dispenser Pan Sensor -
the model number, name and location. IntelliSense makes innovative provides the ability to detect a low and high
sensor technology even smarter by liquid level and distinguish whether the
fluid is water or hydrocarbons. Detection
communicating the connection status and
low Cost of installation of fuel or water will result in an alarm
sensor type to the SiteSentinel iSite.
condition at the console. Detection of a fuel
The SiteSentinel iSites IntelliSense
or high-water condition is useful to disable
technology enables sensors to be Maintenance dispenser power to ensure protection of the
daisy-chained together during IntelliSense technology and the environment. This feature assures that an
installation, eliminating a wiring SiteSentinel iSite System keep track of alarm is sounded if the cable to the sensor
home-run for each sensor back replaced sensors by recording the sensors breaks or if the sensor malfunctions.
to the console in the building. serial number, alongBwith the date and time Part Number: 30-0232-DH-10
S
of its replacement.U Application: Dispenser pans
Detects: Fuel, water high and low level
Compliance Differentiates: Fuel vs. water
OPW provides a full line of Product Detection: 1.25" (3.17 cm) fuel
discriminating and non-discriminating only - 1.25" (3.17 cm) fuel on water
sensors to monitor the environment of Operating Temp: -40 F to 150 F
(-40 C to 65 C)
a fueling facility.
listings and
Certifications
1180
324
Sensors (continued)
INTELLISENSE TECHNOLOGY
Part Number: 30-0232-DH-20 Hydrocarbon Vapor Sensor - designed and other containment locations. This
Application: STP Sumps for the early detection of the presence of feature assures that an alarm is sounded
Detects: Fuel, water high and low level hydrocarbon vapors in dry monitoring wells if the cable to the sensor breaks or if the
Differentiates: Fuel vs. water and interstitial spaces of a double-wall tank. sensor malfunctions.
Product Detection: 1.25" (3.17 cm) fuel The sensor is recoverable from detection Part Number: 30-0230-S
only - 1.25" (3.17 cm) fuel on water and will return to its normal state after Application: Interstitial space of
Operating Temp: -40 F to 150 F the vapors have dissipated. This feature double-wall tank
(-40 C to 65 C) assures that an alarm is sounded if the Detects: Fuel, water high and low level
cable to the sensor breaks or if the sensor Differentiates: Fuel vs. water
Discriminating Interstitial Sensor - Product Detection: 0.2" (0.50 cm) fuel
malfunctions.
utilizes a solid-state optical technology to only - 0.1" (0.25 cm) fuel on water
Part Number: 30-0235-V
detect the presence of fluid in the annular Operating Temp: -4 F to 176 F
Application: Dry monitoring wells, double
space of a tank and distinguish whether the (-20 C to 80 C)
wall tank interstice
fluid is water or hydrocarbons. Detection Differentiates: Fuel
of fuel or water will result in an alarm Discriminating Fuel/Water Monitoring
Product Detection: Hydrocarbon vapor
condition at the console. Detection of a fuel Well Sensor provides the ability to detect
Operating Temperature: -20 F to 104 F
or water condition in the tank interstice the presence of hydrocarbons floating on the
(-4 C to 40 C)
is useful to disable power to a STP and/ surface of water in a groundwater monitoring
or dispenser to ensure protection of the Interstitial Hydrocarbon Liquid with well. Its also able to detect when the water
environment. This feature assures that an Water Indicator - designed for use in a in the monitoring well has dropped below the
alarm is sounded if the cable to the sensor double-wall fiberglass tank to detect the sensor, making the detection of hydrocarbons
breaks or if the sensor malfunctions. presence of fluid and distinguish between no longer possible. The system will alarm
Part Number: 30-0236-LW fuel and water. This feature assures that an indicating that the monitoring well is dry
Application: Tank Interstice alarm is sounded if the cable to the sensor and environmental protection has been
Detects: Fuel, water high and low level breaks or if the sensor malfunctions. compromised. This sensor is used for
Differentiates: Fuel vs. water Part Number: 30-0234-HW-OL monitoring wells that are 6 to 20 feet deep.
Product Detection: Fuel or water 5/8" Application: Interstitial space of Part Numbers: 30-0234-HW-06 (6') (1.83 m),
Operating Temp: -40 F to 176 F double-wall fiberglass tank 30-024-MW-15 (15') (4.57 m),
(-40 C to 80 C) Differentiates: Fuel vs. water 30-0234-HW-20 (20') (6.09 m)
Product Detection: Requires min. 0.1" Application: Dispenser pans
Sump Sensor, Float Switch - designed to (0.25 cm) fuel to activate Detects: Fuel on water surface
detect the presence of fluid in a containment Operating Temp: -40 F to 150 F Differentiates: Fuel on water or when
sump/pan. Additionally, this feature assures (-40 C to 66 C) water drops below sensor
that an alarm is sounded if the cable to the
Product Detection: As little as a 0.1"
sensor breaks or if the sensor malfunctions. Liquid Only Interstitial Sensor - designed
(0.25 cm) fuel on water
Part Number: 30-0231-L to detect the presence of fluid in interstitial
Operating Temp:
Application: Dispenser pans/transitions space of a double-wall tank. The sensor,
Fuel -4 F to 122 F (-20 C to 50 C)
Detects: Fuel, water high and low level utilizing a float technology, activates on the
Water 32 F to 122F (0 C to 50 C)
Differentiates: Fuel vs. water presence of water or fuel and provides
Product Detection: Min. height 1-1/2" (3.81 cm) an alarm condition. Its constructed of a
Operating Temp: -40 F to 150 F chemically resistive non-metallic material,
(-40 C to 65 C) and can be used in sumps, dispenser pans
325
Density Measurement Density Measurement Sensor Components
DENSITY MEASUREMENT SENSOR
Sensor
Whether for a new or existing
installation, the Density Measurement
Sensor easily installs on the OPW
Magnetostrictive Probe. Combining
Part of the
industry-leading accuracy for water,
product and density measurement,
the SiteSentinel family Density
Measurement Sensor uses a
family of products
single magnetostrictive in-tank
probe assembly. intelliSense Features
The sensor continuously
accurate Features
measures the density of the fuel in
Uses float displacement, taking
the tank, providing a measure of even u Trouble-free design
advantage of the precision and accuracy
the smallest changes in product u Easy to retrofit to existing in-tank level
of the magnetostrictive probes level
quality within the API density range. probes (SiteSentinel 924B Probe)
measurement, which is capable of detecting
Fuel density reports can be displayed
changes of 0.0005" (0.0127 mm). u Density and level measurement
real-time on the SiteSentinel family
combined on 1 IS module position
of controllers or exported to an external
installation connection without the need for a
display. The density readings can
Density and level measurement dedicated input channel or
be configured to either nominal or
combined on 1 IS channel. additional wiring
temperature-corrected density.
S
B
u Fits through the same 2" (5 cm) opening
integration
U
B
S
U
Probe Specifications
Specifications Type: Magnetostrictive/float
Material: Nitrophyl, Delrin and stainless Material: All stainless steel construction,
steel spring aluminum cap
Resolution: 0.00004 g/cc Location: Hazardous, Class 1, Division 1,
Group D
Accuracy: 0.0025 g/cc
Probe Inputs: Intrinsically Safe
Density Range: 0.6 - 1.0 g/cc Probe Power Supply: 12 VDC Nominal
Operating Temperature: -40 F to 140 F Level Precision: 0.0005" (0.0127 cm)
(-40 C to 60 C) Level Accuracy: 0.04" (1 mm)
Temperature: 0.9 F ( 0.5 C)
Dimensions: 2" (diameter) x 11" (5 cm
Temperature: 5 RTDs
(diameter) x 28 cm)
Temperature Range: -40 F to 140 F
Number of Sensors Per iSite System: (-40 C to 60 C)
1 per probe or multi-sensor dedicated Data Cable: 1,000' (300 m) Belden 88760
probe equipped with 3 sensors. or 500' (150 m) max. Belden 88761
equipped with 3 sensors.
Proven Magnetostrictive
technology
u Supports extended operating
temperature range:
-40 F to 140 F (-40 C to 60 C)
u Compatible with gasoline, diesel and
other approved fluids
327
Petro Vend Fuel Control Systems
PETRO VEND FUEL CONTROL SYSTEMS
From the smallest fleet to the largest the type of fuel and quantities they fueling business and stay profitable.
petroleum marketing operation, Petro Vend need for complete security, accountability Other industry-leading options like RFID
has been providing effective solutions to and control. access, wireless data communication
meet your fuel control needs since 1961. Systems like The K800 Hybrid, C/OPT and powerful fuel management software
24-hour unattended fleet fueling systems and FIT500 accept nationwide fueling continue to make Petro Vend Fuel Control
like the K800 and AFC only allow network cards as well as local proprietary Systems the leader in 24-hour unattended
authorized users to access fuel, tracking network cards, allowing petroleum fuel management.
every transaction and restricting vehicles to marketers to grow their 24-hour unattended
Maximum Transaction
2000 2000 2000 2000 1,800 999 N/A
Storage
Maximum Proprietary
(local network) Card/Key/ 64,000 64,000 64,000 64,000 10,000 10,000 30
User Capacity
Mileage Reasonability
Dual Card Accountability
Bankcard
Acceptance
Wireless
Communication
Certifications ETL ETL US/C ETL US/C ETL US/C ETL US/C ETL UL
328
OPW Fuel Controls
- Nozzle-handle insulator
STEP 2: Install antenna(s) on OPW
PHOENIX
(colors available)
SOFTWARE
nozzle(s) (Reader)
- Fits standard OPW Nozzles
Illustration B: FSC3000
Illustration D:
The wireless PetroLink application
collects the vehicle I.D. and odometer
and/or engine hours reading and
transmits the data to the FSC3000
which then activates the dispenser.
331
the Fit500 System the Fit500 System Components
THE FIT500 SYSTEM
USB memory key. for installations where no u Cardless operation for either driver,
B building is available. USB key for vehicle or both
u Separate alpha, numeric
S
and
U
transaction backup and card file updates.
function key pads are backlit u Drivers and vehicles can be
for easy viewing at night grouped into accounts for easier
Communication
u Supports a multitude of commercial Optional 900 MHz wireless control of group restrictions,
fueling cards, truck fleet cards and communication between island lockouts and reporting
major bank cards and building. Cell modem, Bluetooth and u Daily and monthly credit allocations
u System is field-upgradeable so 802.11 WiFi communication also available. per card or account
B
you can easily add network U
S
interfaces remotely u Easily create your own color graphic u PCI compliance via multi-tracking
images and transfer them to the application PA-DSS (Payment
u Ideal for marine and ethanol Application Data Security Standard)
fueling applications FIT500 via USB memory key
for the FSC3000 Fuel
u USB memory key for transaction u Change receipt paper without opening Site Controller
backup/transfer and updating card files the FIT500 enclosure
u Optional dial-up or cell modem allows u Windows-based ARTWare
communication to remote locations PC software makes programming
u Each FIT500 can also be outfitted simple and provides system backup
with 802.11 WiFi or Bluetooth u System management can be
communication devices to facilitate performed on-site or remotely via
updates and retrieval of dial-up or cell modem, LAN/WAN
transaction data or Bluetooth connection
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
332
networks Counts in gallons or liters from Pedestal Dimensions: 42" H x 17-3/4" W x
333
C/OPt Fuel Control C/OPt Fuel Control System Components
C/OPT FUEL CONTROL SYSTEM
System
Up to 8 C/OPT Fuel Island Terminals (FIT)
Nowwiththeflexibilityofhaving
used by drivers at the island to activate the
the FSC 3000 within the Fuel Island
fuel dispensers
Terminal, as a stand-alone system,
making this the best solution for USB
commercialfleetormajorbankcards.
With a wide variety of options
available, Petro Vends C/OPT
C/OPT FSC3000
Fuel Control System is one of the
most comprehensive solutions for
your fleet-fueling or petroleum C/OPt Fuel Control System Features
marketing application. u Selectable automatic lockout after three
Profitability
Accepts the widest selection incorrect PIN entries for added security
Benefits
of fueling network and u Dual card accountability allows
u Each FSC3000 can control up to major bank cards. tracking and reporting on drivers
8 FITs with a maximum of 32 hoses using multiple vehicles
per site easy-to-use u Communication ports allow for journal
Customizable prompts for driver printer, PC, serial pass-through port,
u Graphics display guides users clarity. ARTWare PC software modem and Petro-Net connection
through the fueling process with makes configuration a snap.
pictures and text u Wireless Petro-Net communication
reduces installation costs
u Accepts dual readers including installation
Integrated FSC3000 for u Odometer reasonability checking ensures
magnetic, optical, proximity and accurate odometer entries
installations where no building is
ChipKey for maximum Bflexibility u Nine-character name field makes card
S available. USB key for transaction backup
and reliability U
and card file updates. record reporting more complete
u Optional full alpha keypad allows u Cardless/keyless access allows drivers to
entry of vehicle tags and other Communication fuel using a quick keypad entry
alpha information Optional 900 MHz wireless u Office journal printer for transaction log
communication between island and report
u Smart weather shield automatically and building. Cell modem, Bluetooth and
closes to protect card readers and 802.11 WiFi communication also available.
receipt chute S
B networks
u PCI complianceU via multi-tracking
u Fiber-optically lit keypads and LED application PA-DSS (Payment u The C/OPT System interfaces with
Application Data Security Standard) for many authorization and commercial
backlit display for easy fueling at night fueling networks to accept the
the FSC3000 Fuel Site Controller
u Optional thermal receipt printer following cards:
u USB memory key for transaction data
u USB memory key for transaction storage and card updates CFN Fuelman/Gascard
backup/transfer and updating card files T-Chek Bank cards
u Individual drivers and vehicles can be Comdata Pacific Pride
u Optional dial-up or cell modem allows grouped into accounts for easier control Voyager FleetOne
communication to remote locations of group restrictions and lockouts EFS TCH
u Extensive reporting capabilities with Wright Express
u Each C/OPT can also be outfitted
Phoenix Software
with 802.11 WiFi or Bluetooth u Dual network option reduces wait
communication devices to facilitate u Daily and monthly credit allocations per time by accessing two networks
card/key/account lets you set fueling simultaneously
updates and retrieval of
restrictions
transaction data
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
334
u The registered bank card feature permits Memory Pump Control terminal
335
k800 hybrid k800 hybrid Fuel Control System Components
K800 HYBRID FUEL CONTROL SYSTEM
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
336
u Standard system utilizes dispensers with mechanical registers Phoenix Software
337
k800 Fuel Control k800 System Components
K800 FUEL CONTROL SYSTEM
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
338
additional Features
339
PhOenix Software Phoenix Components
PHOENIX
FUEL MANAGEMENT SOFTWARE
PHOENIX
FUEL MANAGEMENT SOFTWARE
u Polls Petro Vend FSC3000/System2 u Provides communication through
for site, account, card, and transaction modem, Ethernet, or direct connection
data, and OPW tank gauges (or other u Eliminates the need for 2 separate lines
brands of automatic tank gauges) for and modems when polling via
real-time fuel inventory information for phone lines
reconciling a sites fueling activities
u Automatic and on-demand transaction
u Ideal for owners of multiple fuel polling enhances ease of reporting
sites who want to integrate the reconciliation information
management of their facilities into
u Centralized card database for
one centralized computer
multiple sites (FSC3000, System2
u Based on Phoenix Plus software version only)
package, and includes full-featured
u Facilitates daily inventory management
back-up and restore, automatic and
on-demand transaction polling, card u Reduces training costs Windows-
management, and over 60 reports based program is easy to learn,
easy to use
u Runs on a Windows PC compatible
with Windows XP or Windows Vista u Stores records in your back-office
PC environment for easy retrieval
Phoenix PC requirements and management
u A Windows PC with 500 MHz or higher
processor speed
u 128 MB RAM
u Runs on a Windows PC compatible
with Windows XP or Windows Vista
u CD-ROM drive
u 250 MB hard disk space
u 800 x 600 display
u Available communications port
341
aFC Fuel Control aFC System Components
AFC FUEL CONTROL SYSTEM
System
With the AFC Fuel Control System One Stand-Alone AFC Terminal
managing your fleet, youll never have can control from 2 to 8 hoses.
to wonder when vehicle maintenance is
due, who gets which fuel type, where
your fuel goes, or how to keep track of
your vehicles.
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
342
additional Features
aFC Specifications
Readers: Magnetic-stripe card, DuraKey
Display: 4-line, 20-character backlit display
Cabinet Dimensions: 10" H x 12" W x 20" D (25.4 cm x 30.4 cm x 50.8 cm)
Operating Temperature Range: -40 F to 158 F (-40 C to 70 C)
Input Power: 120/240 VAC, 50/60 Hz, 100 watts
Output Relay Rating:
Motor Duty: 1 HP @ 120 VAC; 3 HP @ 240 VAC
Pulser Supply: 12 VDC, 2.5 W max.
343
keegarD keegard System Components
KEEGARD FUEL CONTROL SYSTEM
listings and
NOTE: See OPW Fuel Management Systems
Certifications Website at www.opwglobal.com for detailed
product literature, manuals and sales representative
contact information for your area.
344
Model 400-B Model 500 PulSerS
PULSERS
Features Features Petro Vend Fuel Control Systems offer a
u Direct replacement u Main shaft and complete family of pulsers to meet your
for the VR-1871 shaft extensions are fuel management needs.
u No conduit machined from solid
required between aluminum
Model 788
barrier and pulser u Intrinsically safe
head
Features
u No conduit required
u Almost unlimited speed between barrier and pulser head u Minimizes
u Will pulse any voltage 5 to 170 volts u Will pulse any voltage 5 to 170 volts wear and tear
AC or DC AC or DC of new style
registers
u Compatible with most self-service u Compatible with most self-service readout
read out equipment, card and equipment, card and key systems u Easy to align
key systems u Jumpers used to set pulser for type of u Passive contact closure type pulsers
u Available in 12 VDC, 24 VDC, 120 VAC pump computer being used u No gears or mechanical parts
and 220 VAC u Available in 12 VDC, 120 VAC and u Economical alternative to the VR-1871
220 VAC u Optional whole gallon pulsing
u Compatible with most card and
key systems
PULSE RATIO /
$.01 1/10 /
$.01 1/10, 1/100 1/10 1/10 1, 1/10 /
$.01 1/10 1/100
COMPUTING DEVICE
n n n
101 n n n
n n
2001/2002 n n n
2002E * n n
* n n
n
VR10/4 n
n
VR10 n
NON-COMPUTER * n n
FILL-RITE 800/900 n
TOKHEIM/GASBOY 793/50 n
VEEDER-ROOT 7886/7887
n
NEW STYLE
GILBARCO HIGHLINE
n
111B/MPD
* Model 400-B will not work on computers with plastic drive gear on penny or tenth wheel.
New or remanufactured computers may have this plastic gear. Computers with this gear require the Model 500 Pulser.
345
THE WORLD IS MADE UP OF PRISTINE ENVIRONMENTS
346
346