FRE ON R407c
Pf = 7,6 21,7 kW Temperatura maxima apa 60 C
Pt = 9,1 24,8 kW
Mod. 031 081
CALOR SRL - Str. Progresului nr. 30-40, sector 5, Bucuresti - tel / fax : 021.411.44.44 / 021.411.36.14
www.calorserv.ro - ofertare@calor.ro - www.calor.ro
HOTTY este o pompa de caldura aer apa conceputa HOTTY is a reversible air to water heat pump designed for use in
pentru utilizarea in cladiri rezidentiale sau comerciale, noi sau
new or refurbished residential and commercial buildings.
renovate.
Utilizeaza tehnologia E.V.I. (cu injectie de vapori), care le It uses E.V.I. (Enhanced Vapour Injection) technology, which allows
permite extinderea semnificativa a limitelor de operare. significantly extend the operating limits of the appliance.
Dispozitivul de control electronic asigura incalzirea apei The electronic control device manages the domestic water
menajere cu prioritate si permite setarea unor niveluri heating under priority and it allows different temperature
diferite de temperatura pentru agentul termic si A.C.M . set point setting to the user plant water and d.h.w. side.
Produsul a fost creat utilizand cele mai noi tehnologii si a fost The product was developed using the most current design
testat in laboratoare pentru a garanta eficienta si fiabilitate technologies and tested in our laboratories to guarantee
in timp. efficiency and absolute reliability over time.
The Hotty product line is another tile in our mosaic of
hydronic products for air-conditioning that range from special
hot/cold production units to plant terminal units.
CARACTERISTICI TEHNICE
Capacitor - made of
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
copper tubes in an aluminum finned pack and frame
Anumite tevi, de la baza schimbatorului, sunt utilizate pentru supporting the galvanized steel exchanger. On request, a
agentul refrigerent pentru a ajuta la dezghetarea schimba- version an be supplied with prepainted copper or aluminum
torului de caldura pe timpul iernii, cand temperaturile fins for installation in especially aggressive environments.
scad sub 0C.
Some pipes, on the bottom of the exchanger, are used for
the coolant liquid to help defrost the heat exchanger during
the winter period when air temperatures drops below 0 C.
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
- controlul compresorului in functie de valoarea temperaturii de retur - Automatic and dynamic set points according to the
a apei sau, la cerere, in functie de valoarea temperaturii de tur. ambient air temperature.
In modul de racire, daca este necesara producerea de apa - Different temperature set points on user plant side and
calda menajera, sistemul manevreaza automat comutarea pentru DH.W. side.
a atinge temperatura apei calde menajere ceruta. - Three way valve control (accessory) to provide priority to
D.H.W.
- puncte de setare automate si dinamice in concordanta cu - Dynamic defrosting acording to externe air temperature.
temperatura ambientala - Fan speed control
- vana cu 3 cai pentru a acorda prioritate apei calde menajere Accessories available upon request
:
- dezghetare dinamica in functie de temperatura externa - MHL
high and low-pressure gauges
- controlul turatiei ventilatorului - RAE
evaporator frost-resistance;
- SAB
Accesorii disponibile la cerere: basic vibration-damping supports;
- KRC
- MHL remote control kit;
manometre presiune inalta si joasa; - SSC
- RAE Electronic Soft Starter
vaporizator rezistent la inghet; with the function of limiting the inrush current values <40 A
- SAB for single phase units.
suport anti-vibratii; - K3V
- KRC Kit supplied separately, consisting of motorized three-way
kit cu telecomanda valve ball type and NTC temperature sensor to be placed on
- RCA the d.h.w. vessel.
rezistenta compresor; - KRC
- SSC - pornire electronica Remote room control panel able to control the following
cu functia de limitare a valorilor curentului de intrare < 40 A functions:
pentru modelele monofazate On/off control, summer-winter switching, working time
- K3V - kit vana cu 3 cai setting by clock, temperatures reading.
kit livrat separat , alcatuit din vana motorizata cu 3 cai si - KRI (1)
senzor de temperatura NTC pentru a fi montat pe vasul D.h.w. vessel integration electric heater.
de apa calda menajera. - KRI(2)
- KRC - panou control ambient Drain panel antifreeze Electric heater
Panou de control cu urmatoarele functii: Factory-installed accessory. It avoids water freezing
ON/OFF, vara-iarna, setare timp de functionare dupa ceas, contained in the tank with low ambient air temperatures.
vizualizare temperaturi. - KFR
- KRI (1) - incalzitor electric pentru apa calda menajera Mesh water strainer
- KRI (2) - incalzitor electric cu anti-inghet
Accesorii instalate din fabrica: Tava de colectare a condensului
incalzita electric pentru prevenirea inghetului.
BUFFER TANK (user plant side)
- Filtru Y Kit supplied separately. Water vessel assembled into a
steel supporting frame to be fitted under the unit (models
VAS DE ACUMULARE: 031-041-061) or separately on model 081
Kit livrat separat. Vas de acumulare asamblat intr-un cadru de
otel pentru a fi montat sub unitate
(modelele 031-041-061, cu un volum de 70 litri) sau separat
pentru modelul 081, cu un volum de 100 litri.
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
CONFIGURARE CONFIGURATION
TENSIUNE
TIP TIP UNIT SUPPLY REFRIGERANT
DIMENSIUNE DE SIZE
UNITATE REFRIGERENT TYPE VOLTAGE TYPE
ALIMENTARE
________________________________________________ ________________________________________________
C R407C C R407C
________________________________________________ ________________________________________________
Toate modelele pot fi echipate cu rezervor de acumulare All models can be equipped with inertial storage water tank
inertial situat la baza sau langa, in functie de model. located under or next to the equipment according. to the model
MODEL 081 C
Instalare laterala MODEL 081 C
Side installation
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
DATE TEHNICE TECHNICAL DATA
COMPRESOR
Putere consumata (1) kW 2,7 3,8 3,6 5,1 6,8
Curent consumat (1) A 13,7 20,5 6,5 10,6 13,2
Curent maxim A 20,8 30,0 10,0 14,0 1 8,3
Curent consumat la pornire A 97,0 160,0 64,0 92,0 99,0
SCHIMBATOR DE CALDURA
Schimbator de caldura nr 1 1 1 1 1
Debit de apa l/s 0,36 0,55 0,56 0,78 1,0 4
Pierderi de presiune kPa 6 7,1 7,3 14,2 14,5
VENTILATOR
Ventilatoare nr 2 2 2 2 2
Debit de aer m3/s
Numar de rotatii min -1 890 890 890 890 89 0
Putere absorbita (1 singur ventilator) kW 0,17 0,17 0,17 0,3 0,3
Curent absorbit (1 singur ventilator) A 0,8 0,8 0,8 1,4 1,4
POMPA DE CIRCULATIE
Presiune disponibila pompa kPa 60 52 51 72 64
Putere absorbita pompa kW 0,21 0,2 0,21 0,4 0,4
Curent absorbit pompa A 1,0 1,0 1,0 2,0 2,0
CONSUMURI TOTALE
Putere nominala (1) kW 3,3 4,4 4,2 6,1 7,8
Curent nominal (1) A 16,3 23,1 9,1 15,4 18,0
Curent maxim A 23,4 32,6 12,36,1 18,8 2
Curent de pornire A 100,0 163,0 67,0 5 97,0 10
VAS DE EXPANSIUNE
Volum l 6 6 6 6 10
Presiune maxima apa kPa 300 300 300 300 300
Presiune de preincarcare kPa 150 150 150 150 150
DIMENSIUNI - GREUTATE
lungime mm 1220 1420 1670
latime mm 427 531 620
inaltime mm 1115 1215 1400
greutate Kg 158 183 186 223 282
(1) temp. ambientala 35C - temp. apa iesire 7C (1) ambient temp. 35 C - water temp. out 7 C
(2) temp. ambientala 7C / UR 85% - temp. apa iesire 35C (2) ambient temp. 7 C / 85% RU - water t. Out 35 C
(3) Conform cu ISO 3744 (3) According ISO 3744
(4) Masurat in camp liber la 10 m distanta (4) measured in free field condition at 10 m distance
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PERFORMANTE DE INCALZIRE HEATING PERFORMANCE
Tu 35 40 45
10/8,3 9,80 2,28 2,60 9,78 2,47 2,79 9,78 2,68 3,00
15/13,5 11,08 2,34 2,66 11,04 2,55 2,87 11,02 2,77 3,09
20/18,3 12,58 2,42 2,74 12,52 2,64 2,96 12,48 2,88 3,20
Tu 50 55 60
Tu 35 40 45
10/8,3 14,28 3,03 3,35 14,39 3,35 3,67 14,50 3,70 4,02
15/13,5 16,03 3,08 3,40 16,11 3,40 3,72 16,18 3,77 4,09
20/18,3 18,09 3,17 3,49 18,11 3,49 3,81 18,13 3,86 4,18
Tu 50 55 60
Tu 35 40 45
10/8,3 14,25 2,88 3,20 14,37 3,20 3,52 14,47 3,56 3,88
15/13,5 16,01 2,92 3,24 16,10 3,25 3,57 16,17 3,61 3,93
20/18,3 18,07 2,98 3,30 18,13 3,32 3,64 18,17 3,70 4,02
Tu 50 55 60
Tu 35 40 45
10/8,3 20,08 4,11 4,69 20,14 4,54 5,12 20,28 5,02 5,60
15/13,5 22,42 4,18 4,76 22,46 4,61 5,19 22,58 5,10 5,68
20/18,3 25,15 4,29 4,87 25,16 4,72 5,30 25,25 5,22 5,80
Tu 50 55 60
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
Tu 35 40 45
10/8,3 26,64 5,52 6,10 26,81 6,08 6,66 27,01 6,71 7,29
15/13,5 29,93 5,65 6,23 30,10 6,26 6,84 30,29 6,93 7,51
20/18,3 33,84 5,80 6,38 34,02 6,47 7,05 34,19 7,21 7,79
Tu 50 55 60
Valorile PT de incalzire se refera la conditii de operare cu bateria curatata, fara prezenta de gheat a. Altfel, pentru a calcula
capacitatea de incalzire, este necesar sa se ia in calcul factorul de dezghetare prin aplicarea multiplicatorilor de mai jos:
The PT heat outputs refer to operating conditions with the finned coil clean without the presence of frost on the fin area. Otherwise
for the calculation of the heating capacity is necessary to consider the factor "defrost" by applying the multipliers below:
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PERFORMANTE DE RACIRE COOLING PERFORMANCE
Te bs 25 30 35
Te bs 40 45
Tu PF Pa PaT PF Pa PaT
4 7,03 2,74 3,06 6,89 3,01 3,33
5 7,12 2,83 3,15 6,90 3,11 3,43
6 7,21 2,91 3,23 6,98 3,19 3,51
7 7,43 2,98 3,30 7,17 3,28 3,60
8 7,54 3,03 3,35 7,35 3,34 3,66
9 7,81 3,07 3,39 7,59 3,38 3,70
10 7,88 3,09 3,41 7,65 3,40 3,72
11 8,15 3,13 3,45 7,94 3,46 3,78
15 9,07 3,21 3,53
18 10,50 3,33 3,65
Te bs 25 30 35
Tu PF Pa PaT PF Pa PaT PF Pa PaT
4 11,12 2,79 3,11 11,03 3,09 3,41 10,91 3,43 3,75
5 11,43 2,88 3,20 11,31 3,19 3,51 11,10 3,56 3,88
6 11,57 2,96 3,28 11,43 3,28 3,60 11,20 3,66 3,98
7 11,82 3,03 3,35 11,67 3,36 3,68 11,54 3,75 4,07
8 12,05 3,08 3,40 11,93 3,42 3,74 11,70 3,81 4,13
9 12,35 3,10 3,42 12,25 3,44 3,76 12,06 3,84 4,16
10 12,61 3,12 3,44 12,43 3,46 3,78 12,23 3,86 4,18
11
HOTTY 041 M
Te bs 40 45
Tu PF Pa PaT PF Pa PaT
4 10,70 3,84 4,16 10,50 4,33 4,65
5 10,83 3,99 4,31 10,50 4,50 4,82
6 10,95 4,11 4,43 10,60 4,64 4,96
7 11,26 4,21 4,53 10,85 4,76 5,08
8 11,41 4,29 4,61 11,09 4,85 5,17
9 11,79 4,32 4,64 11,41 4,89 5,21
10 11,88 4,35 4,67 11,50 4,92 5,24
11 12,25 4,40 4,72 11,88 4,98 5,30
15 13,51 4,45 4,77
18 15,42 4,54 4,86
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PERFORMANTE DE RACIRE COOLING PERFORMANCE
Te bs 25 30 35
Te bs 40 45
Tu PF Pa PaT PF Pa PaT
4 10,79 3, 69 4,01 10,61 4, 14 4,46
5 10,93 3, 83 4,15 10,62 4, 30 4,62
6 11,06 3, 94 4,26 10,73 4, 43 4,75
7 11,38 4, 04 4,36 11,00 4, 53 4,85
8 11,54 4, 11 4,43 11,26 4, 62 4,94
9 11,93 4, 14 4,46 11,60 4, 65 4,97
10 12,03 4, 16 4,48 11,69 4, 68 5,00
11 12,41 4, 21 4,53 12,09 4, 73 5,05
15 13,72 4, 25 4,57
18 15,72 4, 33 4,65
Te bs 25 30 35
Te bs 40 45
Tu PF Pa PaT PF Pa PaT
4 15,12 5, 22 5,80 14,95 5, 87 6,45
5 15,33 5, 41 5,99 15,01 6, 10 6,68
6 15,52 5, 58 6,16 15,20 6, 29 6,87
7 15,98 5, 71 6,29 15,61 6, 45 7,03
8 16,22 5, 82 6,40 15,99 6, 58 7,16
9 16,75 5, 86 6,44 16,47 6, 63 7,21
10 16,89 5, 89 6,47 16,60 6, 66 7,24
11 17,42 5, 96 6,54
15 19,20 6, 02 6,60
18 21,89 6,13 6,71
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PERFORMANTE DE RACIRE COOLING PERFORMANCE
Te bs 25 30 35
Te bs 40 45
Tu PF Pa PaT PF Pa PaT
4 20,11 6,92 7,50 19,79 7,75 8,33
5 20,38 7,19 7,77 19,83 8,05 8,63
6 20,61 7,42 8,00 20,02 8,31 8,89
7 21,22 7,63 8,21 20,52 8,56 9,14
8 21,52 7,79 8,37 20,99 8,76 9,34
9 22,25 7,88 8,46 21,62 8,86 9,44
10 22,43 7,93 8,51 21,79 8,92 9,50
11 23,15 8,07 8,65 22,54 9,09 9,67
15 25,62 8,26 8,84
18 29,50 8,58 9,16
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
Mi n Standard Max
Temp. apa intrare
C 20 39 53
Inlet water temperature
65
60
55
Leaving water temperature C
50
Temp. apa iesire
45
40
35
30
25
20
20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 50 52
Out Min
Temp. apa intrare Out Max
Incoming water temperature C
Min Max
Temperatura ambientala
C -20 20
Ambient temperature
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
LIMITE DE FUNCTIONARE WORKING LIMITS
Mi n Standard Max
Temp. apa intrare
C 9 12 23
Inlet water temperature
20
Leaving water temperature C
15
Out Min
Temp. apa iesire
Out Max
10
0
9 11 13 15 17 19 21 23
Temp. apa intrare
Incoming water temperature C
Mi n Max
Temperatura ambientala
C + 10 40
Ambient temperature
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PIERDERI DE PRESIUNE SCHIMBATOR BRAZED PLATE HEAT EXCH. PRESSURE DROPS
HOTTY 031MC
Pierderi de presiune _ Pressure drops kPa
30,0
25,0
20,0
15,0
10,0
5,0
0,0
0,2 0,25 0,3 0,35 0,4 0,45 0,5 0,55 0,6 0,65 0,7 0,75
Debit de apa _ Water flow l/s
80,0
Pierderi de presiune - Pressure drops
70,0
60,0
50,0
kPa
40,0
30,0
20,0
10,0
0,0
0,5 0,6 0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7
Portata l/s
HOTTY 081TC
Pierderi de presiune _ Pressure drops
70,0
60,0
50,0
40,0
kPa
30,0
20,0
10,0
0,0
0,7 0,8 0,9 1 1,1 1,2 1,3 1,4 1,5 1,6 1,7 1,8 1,9 2 2,1
Portata
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
PERFORMANTE SECTIUNE HIDRONICA HYDRONIC SECTION PERFORMANCE
HOTTY 031
Presiune disponibila - externe pressure kPa
80
60
40
20
0
0,10
0,15
0,20
0,25
0,30
0,35
0,40
0,45
0,50
0,55
Debit - Water flow l/s
80
60
40
20
0
0,10
0,15
0,20
0,25
0,30
0,35
0,40
0,45
0,50
0,55
0,60
0,65
0,70
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
HOTTY 061TC
120
Presiune disponibila - Externe pressure kPa
100
80
60
40
20
0
0,3
0,4
0,5
0,6
0,7
0,8
0,9
1,0
1,1
1,2
Debit - Water Flow l/s
HOTTY 081TC
100
Presiune disponibila - Externe pressure kPa
90
80
70
60
50
40
30
20
10
0
0,6
0,7
0,8
0,9
1,0
1,1
1,2
1,3
1,4
1,5
1,6
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
156
108
MODEL: 031
IESIRE
1" 1/4 F
466
1114
INTRARE
1"1/4 F
540
14 427 1220
174
120
INTRARE
1"1/4 F
629
188
94
160
MODEL: 081
IESIRE
1"1/4 F
465
1417
INTRARE
1"1/4 F
698
622 1672
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
POZITII MONTARE AMORTIZOARE ANTI VIBRATING MOUNTS POSITION
MODEL: 031
13
.5
12
20
38 95
5 11
20
.5
12
13
.5
12
20
49 95
0 13
20
.5
12
MODEL: 081
13
20
3
82
20
57
9.5 3
82
20
.5
12
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
SPATII NECESARE PENTRU FUNCTIONARE OPERATING SPACES
min. 500
MODEL: 031
min. 350
min. 350
min. 600
min. 1500
min. 500
min. 350
min. 350
min. 600
min. 1500
min. 1800
MODEL: 081
min. 350
min. 800
min. 800
min. 800
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
156
108
MODEL: 031 IESIRE
1"1/4 F
1283
1667
INTRARE
1"1/4 F
277
277
1"1/4 F
174
IESIRE
1"1/4 F
1371
1767
INTRARE
1"1/4 F
278
276
1"1/4 F
MODEL: 081
94
160
487
IESIRE
1"1/4 F
1417
1323
440
1163
INTRARE
1"1/4 F
396
MODEL
031 M 041 M 041 T 061 T 081T
LITRI / LITRE 70 100
COD / CODE 137KA070A 137KA070B 137KA1A00
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
ACCESORII OPTIONALE OPTIONAL ACCESSORIES
86
5
13
MODEL
29 031 M 041 M 041 T 061 T 081 T
COD
137KRC050
Panou de control la distanta (cu montare la interior) - se Room control panel to be connected to the unit via serial
conecteaza la unitate prin placa de interfata deja cablata in interface card supplied already wired into the electrical panel
panoul electric al pompei Hotty. of the unit Hotty.
Permite urmatoarele functii: It allows the following functions:
- control ON / OFF al echipamentului - On / off control of equipment
- comutare Vara / Iarna - "Summer / Winter switching
- setari ore ale functionarii - Setting times of operation
- citire temperatura camerei - Reading of the room temperature
- citire ceas - Clock reading
KIT SCHIMBATOR DE CALDURA / POMPA A.C.M (KSP) D.H.W. PUMP / HEAT EXCHANGER KIT (KSP)
MODEL
031 M 041 M 041 T 061 T 081 T
COD
137KSP100 137KSP110
Kitul de transfer al caldurii apei calde menajere este echipat cu The domestic water heat transfer kit is equipped with an
un schimbator de caldura in placi si circulator de apa cu corp din brased stainless steel plate to plate exchanger and a water
bronz si tevi de cupru. circulator with bronze body and copper piping. All the kit
Toate componentele kit-ului sunt corespunzatoare utilizarii pt ACM. components are suitable for sanitary water use. The purpose
Scopul kit-ului este de a transfera temperatura furnizata de of the kit is to transfer the heating energy coming from the
pompa de caldura catre vasul de apa calda menajera, realizand o heat pump desuperheater to the domestic water vessel
eficienta maxima a schimbului de caldura cu o diferenta mica de allowing the max heat exchanging efficiency with a small
temperatura intre cele doua medii. temperature difference between the two mediums.
Mai mult, schimbatorul de caldura permite o separare totala intre Furthermore the heat exchanger allows a total separation
cele doua medii, evitand orice contact al apei calde menajere cu between the two medium, avoiding any contact of the
apa care circula in pompa de caldura. sanitary water with the water flowing into the heat pump.
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
MODEL
031 M 041 M 041 T 061 T 081 T
Kw / V 3Kw / 230V 1ph 6Kw 400V 3ph
COD
137KRI030 137K RI060
Rezistenta electrica cu imersie este fixata pe vas pentru Immersion type electrical heater to be fitted on the vessel
integrarea incalzirii apei calde menajere. for heating integration of the domestic hot water.
Este completata de un termostat de siguranta si terminal pentru Complete with high temperature safety thermostat and
conectarea cutiei de control a pompei de caldura Hotty. terminal for connecting to the Hotty control box.
MODEL
031 M 041 M 041 T 061 T 081 T
COD
137K3V000
Kit-ul contine vana motorizata cu 3 cai pentru controlul apei Motorized three-way valve kit to control the domestic
calde menajere cu prioritate. Kit-ul poate fi livrat separat sau hot water with logical priority over the plant. The kit can
deja fixat pe vasul de apa calda menajera (daca este furnizat). be supplied separately or already fitted on the DHW
Vana cu 3 cai este comandata direct de catre controler-ul
tank (If provided). The valve is directly drived by the
electronic al unitatii Hotty.
electronic controller of the unit Hotty.
MODEL
031 M 041 M 041 T 061 T 081 T
137SSC100 n.a. n.a. n.a.
COD
Dispozitiv electronic pentru a reduce nivelul curentului de pornire Electronic device to reduce the inrush current of the
al compresorului pe unitati cu alimentare monofazica. compressor on units with single phase supply. It limits the
Limiteaza curentul maxim pana la 40 A. maximum current up to 40 A.
Poate fi montat direct din fabrica sau poate fi livrat separat It can be supplied factory installed or loose for assembly on site.
pentru asamblare la locul montajului.
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
KIT ELECTRIC ANTIINGHET PENTRU TAVA DE COLECTARE CONDENS DRAIN PANEL ANTIFREEZE EL. HEATING KIT
MODEL
031 M 041 M 041 T 061 T 081 T
137KRI120 137KR I130
COD
Previne formarea ghetii pe tava de colectare condens si posibilele It prevents the ice forming on the condensation drain panel
blocaje ale conductei de scurgere in situatii de temperatura and possible obstruction of the drain connection pipe with
ambientala scazuta. low ambient temperature. The kit can be supplied factory
Kitul poate fi livrat asamblat numai din fabrica. assembly only.
MODEL
031 M 041M 041T 061T 081 T
137SAB000 137SAB010 137SAB040
COD
MODEL
031 M 041 M 041 T 061 T 081 T
137MHL000
COD
Permit citirea presiunii / temperaturii refrigerentului They allow the reading the the refrigerant pressure /
pe partile cu presiune ridicata si joasa. temperature on high and low pressure side.
MODEL
031 M 041 M 041 T 061 T 081 T
137KFR000
COD
Vor fi montate pe conducta de intrare, prevenind posibilele To be fitted on the user plant inlet pipe to the unit, it
obstructii ale schimbatorului de caldura prevents the possibility of obstruction of the heat exchanger.
Kit-ul este furnizat separat pentru montare pe loc. The kit is supplied separately for assembly on site.
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
MODEL
031 M 041M 041T 061T 081 T
137KAT010 137KAT020 n.a.
COD
Conexiuni preasamblate pentru conducte intre baza si accesorii Preassembled pipe hydraulic connection between the base
137KA... (rezervor). unit and the accessory 137KA .... (Buffer tank).
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
VERSIUNI CU VAS APA CALDA MENAJERA TIP A.I.C.S. VERSION WITH D.H.W. VESSEL MODEL A.I.C.S.
Apa menajera
Domestic water
+
Dp
-
B5
R.E.
HOTTY 031C - 061C Vas apa 137KA070. optiona Vas A.C.M. tip AICS Apa rece
HOTTY 031C - 061C Water buffer tank 137KA070. optional Domestic water vessel _ AICS Cold water
VERSIUNI CU VAS APA CALDA MENAJERA TIP BAVF VERSION WITH D.H.W. VESSEL MODEL BAVF
apa menajera
+ Domestic water
Dp
-
B6
B5
HOTTY 031C - 061C Vas de apa 137KA070 - optional Rezervor A.C.M. tip BAVF Apa rece
HOTTY 031C - 061C Water buffer tank 137KA070. optional D.H.W. vessel BAVF model Cold water
__________________________________ __________________________________
___________________________________ HOTTY _____________________________________
SCHEMA DE PRINCIPIU A CONECTARII HIDRAULICE WATER PIPING DIAGRAM _PRINCIPLE_
Model HOTTY 081TC Models HOTTY 081TC
VERSIUNI CU VAS APA CALDA MENAJERA TIP A.I.C.S VERSION WITH D.H.W. VESSEL MODEL A.I.C.S.
apa meajera
Domestic water
Dp
+
B5
-
R.E.
HOTTY 081C Vas de apa 137KA100A - optional Rezervor A.C.M. tip A.I.C.S Apa rece
HOTTY 081 C Water buffer tank 137KA100A optional D.H.W. vessel _ AICS Cold water
VERSIUNI CU VAS APA CALDA MENAJERA TIP BAVF VERSION WITH D.H.W. VESSEL MODEL BAVF
apa menajera
Domestic water
+ B6
Dp
-
B5
HOTTY 081C Vas de apa 137KA100A optional Vas A.C.M. tip BAVF apa rece
HOTTY 081 C Water buffer tank 137KA100A optional D.H.W. vessel BAVF model Cold water
__________________________________ __________________________________
CARTE TEHNICA POMPE DE CALDURA HOTTY