Anda di halaman 1dari 2

Series

Miniature 6 Positions

A
1 Pole per Deck

3 Positions
Rotary 2 Poles per Deck

Designed to meet

Selector
or exceed the
Indexing requirements of
MIL-S-3786
Same as and

60
interchangeable
with 50-1926

Switch series

Switches feature totally enclosed, explosion-proof, unitized construction.


NOTES:
ELECTRICAL RATING: Continuous 10 amps at 28 vdc.
MAKE AND BREAK: 5 amps res. 115 vac 4 NO. OF POSITIONS: 2-6 1 Pole per deck
(10,000 CYCLES) 3 amps res. 28 vdc. 2-3 2 Poles per deck
2 amps ind. 28 vdc. 3 NON-SHORTING CONTACTS = Break before make
TORQUE: 1 thru 5 decks - 4 in. lbs. max. SHORTING CONTACTS = Make before break
6 thru 10 decks - 7 in. lbs. max. 2 1 pole per deck, 6 positions, may have stops
ALTITUDE: to 70,000 feet or be continuous rotation. All other switches
TEMPERATURE RANGE: -65C
-65 C to +125C
+125 will have stops.
LENGTH: 1.00 in. max. for 1 deck switch, add 1 Add letter "D" to P/N Code for deck identification.
.35 in. max. for each additional deck. Letter to be adjacent to common terminal.
WEIGHT: .13 lb. max. for 1 deck switch, add
.03 lb. for each additional deck.

P/N CODE: HOW TO ORDER


A 60-1-1 B 6 S C L O P D F
ADD FOR FLUX PROOFING
ADD FOR DECK IDENTIFICATION 1
FOR ONE POLE PER DECK ONLY
ADD FOR O-RING PANEL SEAL, MUST
INCLUDE O-RING SHAFT SEAL
ADD FOR O-RING SHAFT SEAL
ADD FOR LOW LEVEL
ADD FOR CONTINUOUS ROTATION 2
S = SHORTING CONTACTS
N = NON-SHORTING CONTACTS
OR ADD LETTER FROM CODE BLOCK
FOR SPECIAL DECK COMBINATIONS 3
NO. OF POSITIONS 4
TYPE OF TERMINAL
NO. OF DECKS: 10 MAX.
NO. OF POLES PER DECK
DEGREE OF INDEX
SWITCH SERIES

If unable to use standard code, contact factory for UNIQUE PART NO.
3111 Winona Avenue Burbank, California 91504 Phone: (818)846-1800 FAX: (818)842-3396
1.03 [26,2] Max. (1 Deck) .43
1.06 [26,9] Max. With Panel Seal [10,92]
.37
.575 Typ.
.090 [9,40]
[14,61]
[2,29] 1.036 Max.
.250
.37 .06
.37.06 [26,31] .432
"A" Type [6,35] C Locking Ring
[9,401.52]
[9,40 1.52] [10,97] L
6 or more .250.002 .120.003
.120 .003
.082
.082 decks [6,350,06] [3,05 0,08]
[3,050,08]
[2,08]

[9,53] 60
60
"B" Type .41 .888
.375-32UNEF-2A (3/8-32 Thd.)
[10,41] [22,56] .125
.125
2X MS25082-7 Nut Pos. 1
O-Ring panel seal [3,18]
3,18]
MS35333-76 Lockwasher .210 .005
.210.005 .406
.406
.073-72 (1-72 Thds.) 2018-29 Locking Ring [5,330,13]
[5,33 0,13] [10,31]
10,31] .432
TYPES OF TERMINALS See schematic Diagram
AVAILABLE Shaft is shown [10,97]
for terminal identification in pos. 1
PANEL MOUNTING LAYOUT
NOTE: DIMENSIONS ARE SHOWN IN INCHES AND [mm].

2
4 5
C2 3

1
3 6 C
1

3 C1
2 1
2

1 POLE PER DECK 2 POLES PER DECK


2-6 POSITIONS 2-3 POSITIONS

1 POLE 2 POLES

CODE EXAMPLE: CODE BLOCK FOR DECK COMBINATIONS 3


CONTACT
A60-1-8B5G CODE
LETTER
DECKS
NON-SHORTING
DECKS
SHORTING

1 POLE PER DECK, 1 DECK NO. 1 2 3 4 5 6 7 8 9 10 1 2 3 4 5 6 7 8 9 10


8 DECKS TOTAL A
"B" TYPE TERMINAL B
5 POSITIONS WITH STOP, C
D
DECKS 1-7 NON-SHORTING
E
DECK 8 IS SHORTING F
G
1 indicates deck numbers H
Deck 1 next to panel J

10 .25
DC IND.
DC IND. AC & DC RES.
8 DC RES. .20
AC RES.
CURRENT AMPS

CURRENT AMPS

6 .15

4 .10

2 .05

5 10 15 20 25 5 10 15 20 25 30 35
CYCLES X 1000 CYCLES X 1000
LIFE EXPECTANCY CURVE - STANDARD RATINGS LIFE EXPECTANCY CURVE - LOW LEVEL
CONTACT RESISTANCE: .005 ohms initially - .020 ohms after life Janco low level switches are designed to have an
INSULATION RESISTANCE: 100,000 megohms initially initial contact resistance less than .003 ohms,
10,000 megohms after life and less then .010 ohms during life. If a current rating
DIELECTRIC STRENGTH: 1250 vrms initially - 1000 vrms after life greater than .250 amp is required use standard rating.