RXF
ROTARY SCREW COMPRESSOR UNITS
Models 12 through 50
HD
CL SUCTION CL DISCHARGE 14" REQ'D
A FOR
STRAINER
REMOVAL
SEE NOTE 1
OPEN ALL REMOTE
WARNING DISCONNECTS
BEFORE SERVICING
15
32 31
23
2X7 42
1. Allow for coalescer element accessibility; 13 inches for Models 1215 and 22 inches for Models 2450.
2. 6 x 5 Oil Coolers, Flat Plate Oil Coolers and Liquid Injection Oil Cooling are within the RXF Screw Compressor unit envelope.
3. Piping shown is for use with Liquid Injection Kits.
4. Dimensions shown are inches with millimeters in parentheses.
NOTE: Graphic and dimensions below for reference only. Other unit sizes will vary. Use only certified drawings for erection.
CONNECTION DIMENSIONS
MODEL
SUCTION DISCHARGE A B C D E F
NO.
in. mm in. mm in. mm in. mm in. mm in. mm in. mm in. mm
RXF 12 2 64 2 64 36M\, 937 85C\zn 2164 56M\, 1445 57ZB\zn 1472 43M\zn 1104 25ZZ\zn 653
RXF 15 2 64 2 64 36M\, 937 85C\zn 2164 56M\, 1445 57ZB\zn 1472 43M\zn 1104 25ZZ\zn 653
RXF 19 3 76 2 64 36M\, 937 85C\zn 2164 56M\, 1445 57ZB\zn 1472 43M\zn 1104 25ZZ\zn 653
RXF 24 4 101.6 3 76 42B\zn 1075 86 2198 59 1499 60Z\zn 1526 49B\, 1261 29Z\zn 738
RXF 30 4 101.6 3 76 42B\zn 1075 86 2198 59 1499 60Z\zn 1526 49B\, 1261 29Z\zn 738
RXF 39 4 101.6 3 76 42B\zn 1075 86 2198 59 1499 60Z\zn 1526 49B\, 1261 29Z\zn 738
RXF 50 4 101.6 3 76 42B\zn 1075 86 2198 59 1499 60Z\zn 1526 49B\, 1261 29Z\zn 738
NOTE: The suction stop valve is shipped separately for field installation. Make allowances for piping.